RETAIL TENANT S DESIGN MANUAL

Size: px
Start display at page:

Download "RETAIL TENANT S DESIGN MANUAL"

Transcription

1 RETAIL TENANT S DESIGN MANUAL The Pointe, Neworld One Bay Street, #2 Fort Nassau, 1 Bay Street, P.O. Box SP Nassau N.P. The Bahamas This Manual is subject to change from time to time It is critical to refer to the most current version 1st April 2016 REV 00

2 Table of Contents 1. GENERAL INFORMATION 1.1 Introduction 1.2 Building and Consultant Directory 1.3 Key Plan and Criteria Zones 2. DESIGN GUIDELINES 2.1 Glossary of Terms 2.2 Shop Front Criteria 2.3 Food & Beverage Criteria 2.4 Store Interior Design Criteria 2.5 Landlord Control Zone 2.6 Illuminated Signage Criteria 2.7 Interior Finishes Criteria 2.8 Fixtures and Furniture 2.9 Interior Lighting Requirements 2.10 Storefront Security Systems 2.11 Merchandising 2.12 Floor Loads 2.13 Designing for the Disabled 3. BUILDING DESIGN PARAMETERS 3.1 Landlord s Work 3.2 Tenant s Work 3.3 Key Responsibilities Summary 4. TENANT SUBMISSION REQUIREMENTS 4.1 Tenant Information 4.2 Tenant Design Approval Process 4.3 Preliminary Submission Requirements (Step 1) 4.4 Final Submission Requirements (Step 2) 4.5 Final Review and Approval Process (Step 3) 4.6 Development Application Submissions 5. CONSTRUCTION DOCUMENTATION 5.1 Commencement of Tenant Construction 5.2 Procedures During Construction 5.3 Completion of Tenant Construction 5.4 Tenant and Contractor s Acknowledgement Form APPENDIX A BASE BUILDING SERVICES THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 1

3 1. General Information 1.1 INTRODUCTION Purpose of this document This Retail Tenant Design Manual has been created to ensure that all new store designs or renovations / alterations to existing stores, are aligned with The Pointe s established operational or design specifications. All tenant leasehold improvements however small or limited in scope must be fully reviewed and approved by the Landlord prior to commencement of construction. To ensure the design integrity of The Pointe the Tenant is required to adhere to the procedural guidelines specified in the individual lease documents. Nevertheless, it must be clearly understood that in the event of ambiguity the approval to proceed or not to proceed with the Tenant work will remain with the Landlord. It is the Tenant s responsibility to ensure that a copy of this manual is provided to their consultants and contractors and sub-contractors (hereinafter called the contractor(s) and any other person employed by them. Both the Tenant, its consultants, contractor(s) and any other person must fully adhere to the directions provided herein. Failure by the Tenant or its designer(s), contractor(s), or any other person employed by it, to comply with any of the general or specific guidelines because of a lack of understanding or awareness of the Retail Design Manual will not be accepted by the Landlord. It is essential that the Tenant visit the site to inspect and verify all site conditions prior to commencement of design work. The Tenant is responsible for the production of accurate and complete working drawings for the proposed construction within the premises. Although the Landlord will supply the Tenant with lease outline drawings if available, the Tenant must verify the as-built conditions prior to commencement of the Tenant s design. The Landlord reserves the right to add or amend the information and procedures contained herein, which will be in effect upon issuance. Site Details The Pointe is located on the western tip of Nassau s bustling downtown neighborhood just steps from the cruise port. The Pointe is an unrivaled lifestyle and residential development in the Bahamas. Framed by a quarter mile of sun-kissed ocean frontage, this dynamic seven-acre district comprises luxury lifestyle and entertainment, hotels, residences, restaurants and world-class shops interspersed with oceanfront promenades. Retail at The Pointe is a valued and prestigious part of Nassau s developing downtown district and must therefore reflect the sophistication and convenience of a successful development aimed at offering a unique and reliable facility. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 2

4 1.2 BUILDING AND CONSULTANT DIRECTORY BUILDING CONTACTS Landlord The Pointe, Neworld One Bay Street, #2 Fort Nassau, 1 Bay Street, P.O. Box SP Nassau N.P. The Bahamas Building Management The Pointe, Neworld One Bay Street, #2 Fort Nassau, 1 Bay Street, P.O. Box SP Nassau N.P. The Bahamas Tel (242) Fax (242) BASE BUILDING CONTACTS Architect A.D.D. Inc., now with Stantec, One Biscayne Tower, 2 South Biscayne Blvd, Suite 1670, Miami, FL Tel (305) Fax (305) Structural Engineer McNamara Salvia, One Biscayne Tower, 2 South Biscayne Blvd, Suite 3795, Miami, FL Tel (305) Fax M.E.P. Engineer Steven Feller P.E., P.L. 500 N.E. Third Avenue Fort Lauderdale, FL Tel (954) Fax (954) ** If required, design review and consultancy fees for fit-out designs will be paid by the Tenant. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 3

5 1.3 KEY PLAN AND CRITERIA ZONES The following plans are diagrammatic and intended only for the purposes of indicating the applicable criteria for the locations generally as described below THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 4

6 RETAIL SCHEDULE SHOP NUMBER PARK AVENUE NET LETTABLE AREA (NLA) SF APPROX OUTDOOR LICENSED AREA (OLA) SF APPROX R115 (a) 1,802 N/A R115 (b) 1,559 N/A R115 (c) 1,559 N/A R115 (d) 1,559 N/A R115 (e) 1,550 N/A R113 (a) 1,407 N/A R113 (b) 1,178 N/A POINTE PLACE EAST NOTES Area not including egress corridor at rear Area not including egress corridor at rear Area not including egress corridor at rear R101 1, Coffee shop R108 1,101 N/A Convenience store R R R104 1, R R106 & 106 (b) 6,260 2,118 Japanese Restaurant POINTE PLACE WEST R N/A R N/A R N/A R N/A R N/A R N/A R N/A THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 5

7 SHOP NUMBER NET LETTABLE AREA (NLA) SF APPROX POINTE PLACE WEST CTND. OUTDOOR LICENSED AREA (OLA) SF APPROX R108 1,030 N/A R N/A R N/A R N/A R N/A R N/A POINTE PLAZA R N/A R N/A R N/A THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 6 NOTES R117 4,162 1,960 Mediterranean Restaurant R R R R R122 5,655 2,896 American Restaurant BEACH RETAIL R R R R R R Beach Club MARINA & YACHT CLUB Sunset Grille Yacht Club TBD TBD TBD

8 PARK AVENUE KEY PLAN THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 7

9 POINT PLACE EAST KEY PLAN THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 8

10 POINTE PLACE WEST, POINTE PLAZA & BEACH RETAIL KEY PLAN THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 9

11 2. Design Guidelines 2.1 GLOSSARY OF TERMS The following are definitions for terms referred to in this manual; Tenant Lease Line: The line between the Tenant s leased premises and the common area. Tenant work must be limited to the Tenant side of the lease line. The nominal lease line to the built shopfront will be shown on the detailed tenancy plan, together with the approximate leased area. Once the fit out has been completed and accepted by the landlord the actual area of the tenancy will be measured in accordance with the provisions of the Lease Agreement and these guidelines. Closure Line: Is defined by the location of the Tenant s closure system, on or behind the Tenant s lease line. Base building design elements such as columns, walls and floor finishes must be continued by the Tenant from the Tenant Lease Line to the Closure Line. Tenant s finishes cannot extend outside the Closure Line into the common area. Landlord Control Zone: In order for the Landlord to control the quality and diversity of storefront installations within The Pointe, it is imperative for certain standards to be maintained. The Landlord s Control Zone is an area across the entire width of the Tenant s storefront, extending from the Tenant s Lease Line into the space as indicated for each storefront type. The Landlord reserves the right to approve, reject or request modifications to the Tenant s design, quality of detailing, finishes and materials, lighting, signage, security system and closure system within this area. Signage Zone: An area on the storefront in which the Tenant s signage must be installed. Retail Zone: Is defined by the entire retail area that is visibly open to the public from the common space. The Retail Zone extends from the Tenant Lease Line to the Tenant s back wall, including the complete merchandising area. The Landlord reserves the right to approve, reject or request modifications to the Tenant s design, quality of detailing, finishes, material and lighting within this entire area. 2.2 SHOPFRONT CRITERIA The following criteria are to be considered and incorporated into the store designs: It should be noted that all specialty lighting to external street fronts may be the subject of separate application and approval by the relevant regulatory authority. One of a kind storefront designs will be required. Tenants shall not attach to the Landlord s façade by means of mechanical fasteners. Externally, the retail perimeter is defined by full height shopfront type glazing with aluminum frames and doors, running up to a clad soffit (composite material or cement board) and selected stone or concrete block paving. Internally, the concrete floor slabs, blockwork, drywalls and exposed structure frame will form the definition of the shell. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 10

12 Tenants are to use materials of a unique composition giving a backdrop of clarity to the product on display. Variety and individuality are encouraged but it is important to ensure each shop is complimentary to neighboring tenancies and overall to The Pointe development. Shopfronts should be personalized and at the leading edge of innovation in retailing. The finished appearance of the shopfront is a key factor in attracting customers to each shop. Figure 1 illustrates the typical tenancy bulkhead/shopfront arrangement. It outlines the requirements with regard to single or double height space to be constructed by the Tenant. The shopfront bulkhead shown on Figure 1 is indicative to show the design intent and is subject to further design development and/or detailing. Shopfronts are encouraged to be visually as open as possible and encourage circulation between tenancies. However it is essential to design elements to unify the bulkhead and floor of each tenancy. This may be achieved by suitably located vertical elements or by bulkhead projections or wall reveals being reflected in floor treatments. Where the side of a tenancy adjoins public space, the shopfront is typically open or glazed. Movable extensions beyond the Tenant Lease Line may only be approved by the Landlord if it adjoins an outdoor Licensed Area and is subject to review and approval by the Landlord. Any structural column exposed within a shopfront zone including inter tenancy walls must be finished as part of the shopfront works (on the tenant s respective side). Figure 1: typical tenancy bulkhead/shopfront arrangement. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 11

13 Shopfront support structure. The main structure of the building has minimal allowance at the Tenant Lease Line for lateral support of roller grilles and/or shopfronts. The Tenant should ensure that suitable structural support is provided to doors and any openings (or additional openings). No penetrations or modifications to the structure are permitted without the prior written approval of the Landlord. All additional supports or frameworks are to be certified by a qualified Structural Engineer. Due allowance should be made for structural movement and/or tolerances. Any additional structural supports that are required will be at the Tenant s cost. Structural columns in the shopfront zone must be finished by the Tenant and an innovative approach to cladding adopted. Materials All materials must be of a high quality, durable and appropriate for the desired location and presentation of the shop. Preferred materials for use in Tenant s fit out and shop window displays include: Stained, etched, sandblasted, colored or themed multi-pane glass. Stained and/or polished timber. Stainless steel or polished aluminum. Stone. Ceramics. High quality powder coated sections. The following materials are not permitted for use as a material forming part of the façade/ shopfront unless innovation can be demonstrated and special approval granted by the Landlord: Mill or anodized finish aluminum. Exposed un-rendered block or brick. Brush or roller painted shopfronts. Unfinished plaster and plasterboard, cork, sheet vinyl, wall paper, fabric, carpet, laminated plastic, pegboard. Items fixed with screw snap covers or pop-rivets. Surface mounted light fixtures. Surfaces or projections which may prove hazardous for persons visiting and using The Pointe facilities are not permitted. Allowance should be made for concourse cleaning machines impacting the shopfront area. All exposed blockwork, drywall or bare concrete within the base build retail shell must be clad with an approved material. Designers are encouraged to treat materials in an innovative manner. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 12

14 Shopfront Soffit Certain retail shopfronts have been designed with a common external soffit outside of the tenancy to provide a unified backdrop to each shopfront. Tenancies bulkheads and interior ceiling heights may vary in different retail areas and in certain cases the Tenant will need to construct a soffit inside the shopfront glazing as part of the fit out. If required, the detailed tenancy plan will illustrate the soffit and bulkhead requirements specific to each tenancy. External Floor Finish (Hardscape) On shopfronts facing external areas a hardscape finish of patterned concrete, stones or pavers will be laid up the shopfront Tenant Lease Line. The Tenant shall be responsible for building up or ramping the floor at a gradual slope to meet flush with the external floor finishes. Interior Floor Finish Each tenancy shall design and install flooring that will suit its needs and which will be finished in accordance with the recommended materials. In most instances the flooring will have to be laid on secondary topping slab. The base build provides for a either a rat slab or a strip slab around the perimeter of the tenancy so the Tenant s designer can coordinate floor boxes etc. without the need to cut or track existing concrete works. Any topping slabs or finished floor slabs will be constructed at the Tenant s cost. The demarcation on the Tenant s Lease Line between hardscape and the tenancy floor shall be constructed as a control joint. In all cases, the tenancy floor finish must finish flush with the external flooring (hardscape) at the shop s entry point. Reducing strips or ramps are not acceptable outside of the Tenant s Lease Line. Mezzanine Floors If space permits and the Tenant decides to build a mezzanine level in the tenancy, the proposed design shall be accompanied with full structural documentation. Design and construction of a mezzanine level is subject to separate application and approval by the relevant regulatory body in terms of occupancies for fire egress etc. In addition the proposed design shall be accompanied by full structural documentation. If the mezzanine is public facing, the floor finishes must be compatible with the Landlord s requirements for the rest of the tenancy. Movement Control Joints. Where applicable, joints in tenancy floor or wall finishes are to match existing structural and control joints, as indicated on the detailed tenancy plans. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 13

15 2.3 FOOD AND BEVERAGE CRITERIA Tenancies which could be described as offering one or more of the following are bound by the same rules as those governing general retail tenancies with extra requirements as described in this section; (1) Full service or buffet restaurant (2) Bar (3) Fast food (4) Coffee shop (5) Market (grocery) (6) Concession (7) Deli (8) Caterer (9) Fish market (10) Meat market (11) Specialty food store (12) Convenience store (13) Food manufacturer with retail sales The Tenant shall provide design plans to show the location and identification of all equipment and areas including; (1) Bar service area(s) (2) Hand sink(s) (3) Chemical dispensing unit(s) (4) Chemical storage area(s) (5) Ice bin(s) or Ice machine(s) (6) Indoor/outdoor seating (7) Dipper well(s) (8) Goods in/return location(s) (9) Walk-in freezers/fridges/cold storage/reach in coolers/blast chiller/retail display(s) (10) Steam table(s)/hot boxes/cook & hold units (11) Dry storage area(s) (12) Laundry facility/clothes washer(s) and dryer(s) (13) Dish machine(s) (14) Dishwashing sinks(s) (15) Dump sink(s)/knock boxes (16) Utility mop sink(s) (17) Food preparation sink(s) (18) Grease interceptor trap(s) (19) Water heater location(s) (20) Floor sinks/floor drains (21) Wait station(s)/bus station(s) (22) Outdoor cooking/bar/patio areas (23) Dry storage area(s) (24) Restroom facilities, showers, hand wash sinks, toilets and hand washing sinks (25) Hose bibs and hose reels THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 14

16 Objectionable odours shall be exhausted in such a manner so as to prevent their release into the general mall circulation areas or adjacent tenancies, or short circuiting into any fresh air vents. The exhaust system supplied and installed by the Tenant must be designed in accordance with the Landlord s base building requirements and connect in the locations shown on the detailed tenancy plans. Rear stock storage or food preparation areas, which are unsightly and/or not specifically designed to be open concept or are unsightly, are not to be normally visible to the public. Menu boards must be illuminated and coordinate with the design of the general tenancy shopfront signage. Boards and displays must be specifically designed for this project and shall not be of expanded plastic construction. Food & Beverage tenancies requiring exhaust canopies which exceed the Landlord s base building make-up air system will be required to provide a separate system / exhaust fans at the Tenant s cost and subject to review by the Landlord. Exhaust canopies provided by the Tenant must be manufactured by Garland Vent Master, Gaylord or Quest. Exhaust canopies should meet the following criteria; constant cold water spray, hot water wash-down cycle, fusible link activated exhaust dampers, welded ductwork and volume control dampers (for multiple hoods). All exhaust canopies shall be complete with micro-switches for interconnection to the base building s fire alarm system by the Landlord s contractor at the Tenant s expense. Exhaust hoods and fans, shall be installed at the Tenants expense, in accordance with all relevant NFPA regulations and to the review of the Landlord s insurance company and all regulating authorities having jurisdiction. Hoods shall be complete with automatic fire extinguishing systems. All approvals by the regulating authorities shall be the Tenant s responsibility. The Landlord s contractor at the Tenant s expense will perform all openings, installation of supports and curbs and all other construction work affecting the roof. Air handling equipment may not under any circumstances draw air from the general mall circulation area or exhaust into it. The Tenant must install garbage compaction or refrigeration equipment in the tenancy if the Tenant s design requires it for compliance with applicable governing laws, codes and regulations. Check type water meters with remote readout, if required by the Landlord, shall be installed and maintained by the Tenant at the Tenant s expense. Tenants whose business involves the disposal of greasy substances shall provide suitable floor mounted grease traps within their premises, to prevent such substances from entering the sanitary drain lines. Certain tenancies have connections to a central grease trap system; refer to the detailed tenancy plans for points of connection. The Landlord at the Tenant s expense shall perform the maintenance of the Tenant s exhaust and grease traps. The extension of all gas piping to any Tenants equipment, including makeup air units and cooking appliances, shall be by the Tenant. The Tenant shall also provide an electric solenoid gas shut-off valve with manual reset for interconnection with the base building fire alarm system by the Landlord s contractor at the Tenant s expense. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 15

17 Gas meter, to monitor gas consumption, shall be supplied and installed by the utility company at the Tenant s expense. Approved backflow protection must be supplied by the Tenant on all fixtures and equipment with submerged inlets. Vacuum breakers must be installed on water inlet lines for dishwashing machines, garbage disposals and hose bibs. Continuous pressure backflow devices must be installed on water lines where a valve or shut off is located between the backflow preventer and the inlet to the fixture/equipment, such as hose reels, iced tea machines, smoothie machines et. (at the Tenant s expense). All light fixtures in kitchen areas, dry storage areas, dishwashing areas, inside equipment and above areas where open foods are displayed or held must be equipped with shatter proof bulbs or shields that will protect open food, utensils and single use items from broken glass if a bulb is broken. Staff lockers and restroom/showering/changing facilities, if required by Building Control or Health department, must be provided by the Tenant within the leased premises. 2.4 STORE INTERIOR DESIGN CRITERIA All Tenants are required to provide high quality, finely detailed and unique interior designs which are compatible with the shopfront in design and theme. The finishes should be of a high standard suitable for the products and services offered. Clever and efficient design will maximize the use of space in a three-dimensional sense through careful consideration of the volume of the space that the Tenant is leasing. 2.5 LANDLORD CONTROL ZONE The Landlord Control Zone is an area across the entire width of the Tenant s storefront, extending from the Tenant s Lease Line. The entire public facing space at the Tenant s shopfront, including any food service counters are in the Landlord s Control Zone. To maintain a high level of design and finish the Landlord reserves the right to approve, reject or request modifications to the Tenant s design, quality of detailing, finishes, material and lighting within this entire area. 2.6 ILLUMINATED SIGNAGE CRITERIA Shopfront signage is one of the most critical elements of retail at The Pointe. A graphic designer should be employed by the Tenant to prepare a creative proposal for submission and review by the Landlord. General illumination and special display lighting needs to be considered in conjunction with the signage design. It should be noted that all signage and specialty lighting to external street fronts may be the subject of separate application and approval by the relevant regulatory authority. Signage shall be located within the defined limits in front the Tenant Lease Line and should be designed as an integral part of the shopfront design. As a guide, signage should not exceed 6 sq ft per lineal foot of shopfront. The horizontal dimension shall not exceed two thirds of the width of the shopfront. Signs wider than one third of the shopfront must be perforated, segmented or individual letters. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 16

18 A horizontal signboard has not been included as a basic architectural feature because the intent is to encourage more creative signs that are designed to be part of the overall shopfront design. Where applicable the bulkhead above the shopfront glazing will be designed to accommodate lightweight signage (to the width parameters as described in this section). Two illuminated shopfront signs per shopfront elevation will be allowed (depending on the width of the shopfront and subject to review and approval by the Landlord). Signage should identify the shop name or trading name only and not spell out the type of merchandise it is selling or the service it offers. No commercial brands or trademarks are to be displayed other than the approved trading name. The use of a crest, logo or other established corporate insignia or graphics may be permitted with the Landlord s approval. Signage and any strong horizontal back paneling cannot be placed be placed closer than five feet from the margin at either side of an individual storefront. Three dimensional signs are encouraged. Blade signs can be used on external storefronts but should be designed in such a way as to not obstruct adjacent tenancy signs or base building signs. Sign Illumination The minimum acceptable standard for a sign generally is a three dimensional individually illuminated letter type. Illuminated box signs or non-illuminated letters will not be accepted, nor shall any strobe or activating light. Moving or rotating signs are not acceptable, nor are cardboard or foam letters. Certain externally illuminated or non-illuminated signs may be considered, providing their design specifications relate wholly to the theme of the shop. Such techniques as sand-blasted glass, etched stone or polished stainless steel letters, for instance, may be appropriate for merchandising presentation. Signage Design Signage must be imaginative and of high quality. All signage proposals must be designed as an integral part of the shopfront and must be approved by the Landlord. No sign, advertisement, notice or other poster or lettering shall be exhibited, inscribed, painted or affixed to any part of the any shopfront unless specifically approved. Signs, notices or graphic display, particularly self-illuminated signs located in the interior of the tenancy and easily legible from the concourse, shall only be allowed if specifically approved by the Landlord. All attached devices, wirings, clips, transformers, isolating switches, lamps, tubes, labels or plates on signs are to be concealed from public view. No signage contractor labels are to be visible. Any structure required to support signage or any alterations or subsequent rectification of shopfronts or soffits/bulkheads caused by installation of signage shall be the responsibility of the Tenant. In all cases, any additional structure required for the support of signs must be checked by a structural engineer and certification required. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 17

19 2.7 INTERIOR FINISHES CRITERIA Storefront Materials and Finishes The Tenants storefront materials are critical in creating a quality and dynamic retail experience. To maintain a high standard of design and retail animation. Tenants are encouraged to use durable materials of superior quality. All materials are to be designed over a durable substrate and must be long lasting with minimal maintenance requirements. All storefronts shall comply with all governing and building and fire code requirements. The Landlord reserves the right to reject or request substitutions or adjustments to the proposed shopfront finishes. All materials must be approved by the Landlord prior to installation. Floor Finish The finished floor is to reflect the desired theme of the shop interior and must finish flush with the external paving at the entry. The Tenant will be responsible for designing and constructing any secondary topping slab. The base build provides for a either a rat slab or a strip slab around the perimeter of the tenancy so the Tenant s designer can coordinate floor boxes etc. without the need to cut or track existing concrete works. Any topping slabs or finished floor slabs will be constructed at the Tenant s cost. Where shopfront entrances are behind the Tenant Lease Line, the base building external finish is to be adopted to a line that should be agreed with the Landlord prior to installation of interior floor finishes. The following are permissible floor finishes: Stone Timber or parquetry High grade commercial quality carpet High grade commercial quality ceramic tiles, polished concrete, vinyl sheet or tile, rubber flooring or laminated timber flooring will not be permitted as a floor finish unless innovation in their use can be demonstrated and the Landlord provides specific approval in writing. Carpets are to be a minimum of heavy commercial grade and special attention should be paid to the durability and color of any soft floor finish at the shop entry. Tenants are responsible to ensure that store floor coverings are graded to match the floor finish at the shop entrance. There are to be no trip hazards and all slip coefficients of floor finishes must be suitable for commercial grade applications. At entries, lips of more than 1/8 and ramps of more than 1:20 are not permitted. Where applicable, joints in tenancy floor or wall finishes are to match existing structural and control joints, as indicated on the detailed tenancy plans. Chases and/or saw cuts into the structural slab may be allowed subject to the approval of the Landlord and his Structural Engineer. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 18

20 Walls and Columns The full height inter-tenancy walls erected as part of the base building works will be steel stud framed walls lined with sealed but unpainted sheetrock. Walls bounding services corridors and fire exits may be fire rated blockwork or fire rated drywalls. All inter-tenancy walls extend to the inner face of the shopfront mullions The issued detailed tenancy plans verify the type of construction and build-up of all walls surrounding the leased space. All proposed internal partition walls must be full height to ceiling except for change/fitting cubicles. In the case of steel framed inter-tenancy stud walls no direct unsupported loading is to be applied by way of fixtures and fittings. All wall/column surfaces exposed to public view shall be lined/finished smooth and painted. No exposed painted masonry or pre-cats concrete will be accepted unless required as part of a specialist design feature within the shop display area itself. Base board should be affixed to wall surfaces to minimize marking. Skirting trunking may be used to conceal electrical services. No exposed conduits will be accepted. Structural columns that occur within the tenancy zone must be included in the overall tenancy design proposals. While maintaining their structural and fire integrity, appropriate cladding and finishes are to be provided at the Tenant s cost and must be approved by the Landlord. Ceilings Ceilings within the tenancy are to be installed by the Tenant. The ceiling will, as a minimum, be smooth plastered flush sheetrock in public facing areas. Suspended/drop ceilings may be employed in non-public facing areas. Variations to ceiling finishes and/or heights are encouraged. Subject to the Tenant s design, fire rating for ceilings, acoustics and security infrastructure requirements shall entirely be addressed the Tenant Emergency exit signs installed within the tenancy are to be edge lit blade type and are required to be monitored by the base build emergency monitoring system. Ceiling mounted emergency light fixtures need to be provided by the Tenant in accordance with the Landlord s base build requirements as these will also be monitored by the base build emergency system. The Landlord will commission the monitoring system to recognize the Tenant s emergency light fixtures. All fixtures within the Tenant space must be independently supported as free standing fittings not to re-use the Landlord s base build system that is directly fixed to the inter-tenancy walls. It is the Tenant s responsibility to provide sound insulation where required (to contain noise transfer to residential units above for example). Acoustic treatments may be required as part of the Tenant s fit-out to achieve the building s recommended internal noise levels. The Tenant should confirm the requirement with the Landlord prior to commencing the shop fit-out design. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 19

21 2.8 FIXTURES AND FURNITURE Quality, durable materials are to be specified for the construction and finishes of the interior fittings, joinery and furniture. Such materials may include: Glass Ceramics Stone Polished timber Leather Brass Selected plastic laminates Painted surfaces must be hard wearing via the use of baked enamels, powder-coats or lacquers. All materials and finishes are subject to the review and approval of the Landlord. Fixture details will be required to be submitted to the Landlord for approval and drawings should indicate quantities, locations, detailing, finishes and quality. Displays are not permitted beyond the Tenant Lease Line unless in the Licensed outdoor area and with prior approval by the Landlord. Closets for fire hydrants and/or hose reels, required as part of the tenancy, are not to be located in the shopfront zone. The closet should be incorporated into the overall design or added to the back of house zone. The installation of such closets will be at the Tenant s cost, in accordance with the local authorities requirements and the approval of the Landlord. The Tenant will be required to include sprinkler protection to any display show-case, bulkhead, canopy or to suit new walls/full height partitions etc, in compliance with the statutory requirements. The Tenant should consult the detailed tenancy drawings for base build sprinkler provisions. The Tenant s sprinkler work will need to be coordinated and signed off by the Landlord s MEP consultant. Any costs incurred by the inspection and/or approval process shall be borne by the Tenant. 2.9 INTERIOR LIGHTING REQUIREMENTS Tenants must have dramatic and well illuminated storefronts, emphasizing their visual presentation, display windows and architectural features. Tenants are encouraged to seek the advice or services of a lighting consultant when designing the lighting layout to achieve high quality light and individuality. In addition to provision of light fixtures for illumination, lighting design should maintain good visual variety and balance. Lighting color should also be carefully considered to provide enhancement of merchandise. All light fixtures shall be of high quality commercial grade. No lamps or bulbs will be permitted that are directed or aimed into the common area. Exposed or unshielded neon tube lighting will not be permitted in public facing areas. All light fixtures and installations must conform to all applicable Building and Construction Codes and regulations. Tenants are encouraged to use low energy consumption luminaires. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 20

22 Electrical supply distribution is to be via the ceiling, fixed shop fitting units and/or partitioning. Exposed conduit or wiring is not permitted except in feature pendant fixtures for example. Undiffused fluorescent fittings will not be accepted and all general lighting is to be amplified with accent lighting. No fluorescent battens will be allowed to be attached to the underside of the ceiling unless except to areas out of public view, such as storage areas. Pelmet lighting must be diffused or by other means concealed from public view. Imaginative lighting solutions are encouraged. The Tenant shall provide a high level of illumination to the shopfront display which will highlight the merchandise and provide for a daytime (business) and night time (after hours) setting. A zone of minimum 1,200 Lux lighting level at 3ft above the floor is to be installed by the Tenant generally within 6ft of the shopfront. Display lighting should be a minimum of 1,000 Lux and be on a separate circuit to that of the general shop lighting. Shopfront lighting must be controlled to provide glare free illumination at the shop glass line. The Tenant s lighting design should coordinate with any base build light fixtures on the underside of the entry soffit refer to the detailed tenant drawings for locations and specifications. Emergency and exit lighting must be provided by the Tenant and be coordinated with the overall shop lighting design and the Landlord s base build emergency monitoring system. It should be noted that all specialty lighting to external street fronts may be subject to separate application to and approval by the relevant regulatory body (for traffic safety) STOREFRONT SECURITY SYSTEMS The Tenant is to provide any special security systems inclusive of wiring, alarms, locks etc. at the Tenant s cost. Loud audible alarms are not acceptable. Storefront electronic security systems and any other shoplifting detection devices must be integrated into the Tenant s storefront design. Any such devices must be concealed from view from the common areas. Any theft detection/security device system must be submitted with the overall design submission. No system will be installed unless approved by the Landlord. Failure to comply with this approval process may result in the removal of such systems by the Landlord at the Tenant s expense. All wiring to security systems must be concealed from view. Power poles and wiring channels exposed to view are not permitted. After hours security systems should be monitored off-site by Tenant. No audible alarms are permitted after hours CLOSURE SYSTEMS The storefront glazing is provided as parts of the Landlord s base build with doors as shown on the detailed tenancy plans. If the Tenant wishes to construct new door openings on the storefront, then the framing etc. must exactly match those provided by the Landlord. Any additional doors or openings will be subject to the Landlord s approval. In all circumstances, open doors shall not extend beyond the Tenant s Lease Line. Generally, roller doors or grilles will not be permitted. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 21

23 2.12 MERCHANDISING Window merchandising sets mood and character attracts attention and identifies the brand. Displays within the storefront and interior should be bold, strong, imaginative and themed to reflect the products on offer. Merchandise on display should have interest and appeal to entice patrons to explore the tenancy. Window displays should be assembled with consideration towards the following: Avoid locating products at knee or eye level. Avoid cluttering with unnecessary merchandise. Create a story with balance of color, shapes and repetition to draw the eye around the display. Group products together to assist in achieving companion sales (when two different products are put together to form a unique product). Displays should be interesting from all sides. Food Merchandising In addition to the standard tenancy guidelines, special requirements apply to food tenancies. To achieve a high level of presentation the set up and maintenance of food displays is essential. The product should be presented in a fresh, hygienic and organized way to best display the product. Consideration of the following is required when merchandising food: Display cabinets are to be incorporated into the overall design. Labelling and pricing tags should be professionally designed and presented. Food displays should be appropriately illuminated. Food and beverage tenancies should avoid the use of standard stainless steel trays for food presentation. Alternatives including containers of varying shapes, sizes colors and materials should be used. For example glass or ceramic bowls, vases, wicker baskets etc. Various additional items such as sculptures, antiques, kitchen accessories, unusual bottles or containers can be used to increase impact and presentation. Excellence of food presentation and housekeeping are essential. Counter Front and Sneeze Guards Food and beverage counter fronts are subject to approval by the Landlord and should comply with all relevant statutory regulations with regards to Environmental Health etc. Materials should include tiles, stone or polished timber and be compatible with the overall concept. Sneeze guards must be glass, either curved or straight and internally illuminated. Tickets, Prices Tags and Packaging Tickets, price tags and packaging are another opportunity for creativity and innovation. Thought should be afforded to the size of promotional tags, pricing systems, ticketing, shape, color and texture to ensure that these elements do not dominate the product on display. Carry bags and/or boxes should carry the store name and/or logo type. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 22

24 2.13 FLOOR LOADS Base build sub-floor loading provisions are described on the Landlord s detailed tenancy plans. In the case of new walls, posts, stairs or any other major design elements being added to the tenancy, the Tenant is required to engage a Structural Engineer to determine that the design does not exceed the floor load criteria provided. All Structural design fees and costs relating to the floor loading checks and calculations are to be paid by the Tenant. The floor loading is subject to approval by the relevant Local authorities and the Landlord DESIGNING FOR THE DISABLED In designing the tenancy fit-out, access for all customers and staff with disabilities is to be provided in accordance with the relevant local regulations and guidelines. The provision for access is a legislative requirement and it is the responsibility of the Tenant to ensure that all requirements are met. Any finishes to columns should possess 30% luminance contrast with surrounding surfaces. All floor finishes should be designed for people with disabilities to have flush thresholds etc. Any changes in level or steps (or at edges of shop displays etc.) should be clearly distinguishable by persons with visual impairment. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 23

25 3. Building Design Parameters 3.1 LANDLORD S WORK The Landlord will provide the following on a once only basis and in accordance with his detailed tenancy plans and specifications: 1. Basic Space A basic space, as shown on the plan attached to the lease. 2. Walls and Columns Inter-tenancy walls consist of sheetrock and will be sealed and unpainted. Any cutting and patching of the wall for the installation of wiring, plumbing and other fixtures shall be the tenant s responsibility. Columns within the Tenant Leased Space will be unpainted off-form concrete or primed and fire sprayed steel. The unfinished columns and concrete walls will be finished by the Tenant as part of their design. Where steel columns have been 3. Floors The base build provides for a either a rat slab or a strip slab around the perimeter of the tenancy so the Tenant s designer can coordinate floor boxes etc. without the need to cut or track existing concrete works. Any topping slabs or finished floor slabs will be constructed at the Tenant s cost. Refer to the structural slab levels on the detailed tenancy plans and on site. 4. Ceilings Underside of concrete slab (or composite deck) with exposed and fire coated beams visible. Ceiling loads shall not exceed 10 pounds per square foot. Acoustic treatments will be required as part of the Tenant s fit-out if a ceiling is not installed. The Landlord will confirm and approve requirements. 5. Electrical Services (a) Power supply Tenancies will receive a supply cable for three phase supply capacity ranging from amps, depending on the Tenant s functional requirements. (b) Communications supply a 10 pair telecommunications backbone cable will be provided to a point indicated on the detailed tenancy plan. (c) T.V. - Co-axial cabling will be provided to a point indicated on the detailed tenancy plan. (d) Emergency Provision of emergency lighting and exits signs shall be the Tenant s responsibility (linked to the Landlord s monitoring system). THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 24

26 6. Plumbing and Drainage The Landlord will provide access only to the following services for Tenant s connection on an asneeded basis. Access locations for these services vary and shall be verified by the Tenant. The Tenant is not permitted to core through the concrete walls and slabs without express permission from the Landlord. Tenant is required to provide fire stopping to re-establish fire separations and to ensure compliance with all local Building Codes and regulations. (a) Main water supply capped off with a control valve and a ¾ feed provided for tenancy connection. (b) 6 sanitary drainage point provided for tenancy connection. (c) 6 grease waste point provided (for food & beverage tenancies) connected to a grease interceptor trap. 7. Mechanical Services The Tenant should employ a Heating Ventilation and Air conditioning (HVAC) consultant to design and coordinate the specific mechanical provisions for each tenancy prior to finalizing the shop design. (a) Condenser water (CCW) points provided for tenancy connection. (b) Chilled water (CChW) and Heating Hot water (HHW) (in food & beverage tenancies only) points are provided for tenancy connection. Hot water services are provided for normal business hours only. (c) Access to outside air via built in grilles and ducts to shopfront perimeter of tenancies. (d) Kitchen exhaust (KEF) ductwork tapping points provided for restaurants and food & beverage tenancies. Hoods, fans, PCU s and fit-out are required to be installed by the Tenant and are subject to approval by the Landlord (including limits on hours of operation). (e) Propane gas supply will be made available by the Landlord for food & beverage tenancies. The supply will be capped off with a control valve and 7kPa pressure. (f) Sanitary amenities exhaust (TEF) ductwork tapping point provided. (g) Refer to the detailed tenancy drawings for specific provisions and allowances and locations of tapping points and outlets etc. The Tenant should carry out a site inspection to verify the locations of the Mechanical Services equipment prior to commencing with the store design. 8. Fire Services (a) A sprinkler system is provided by the Landlord in accordance with Bahamas Building Code and local regulations based on an open floor plan unfinished space and substantially conforming to the Landlord s base building mechanical drawings. Tenants are recommended to employ the Landlord s sprinkler contractor (and/or have their HVAC consultant liaise and coordinate with the Landlord s consultant) for any modifications to the sprinkler system. Modifications (including fees for permit submittals) shall be at the Tenant s expense. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 25

27 (b) The fire alarm system and sprinkler system is installed in accordance with applicable legislation. Tenants are required to consult with the Landlord regarding any proposed modifications to the fire alarm system and sprinkler system, at Tenant s expense. It is the Tenant s responsibility to seal all penetrations and maintain the required thermal insulation and fire rating of the building structure. Smoke detection and emergency warning intercommunications system (EWIS) connection points are provided. (c) Smoke evacuation equipment in common public areas is provided in accordance with applicable legislation. (d) Fire hoses are provided in accordance with applicable legislation. 9. Tenant s Work recommended to be performed by Landlord s approved Contractors It is recommended the Tenant s work set out below shall be performed by the Contractors designated by the Landlord at the expense of the Tenant. (a) All approved modifications or connections to the base building systems, including all work outside the Tenant s premises i.e. the base building hot water, cooling, ventilation, exhaust, controls, electrical distribution and life safety systems as installed by the Landlord. (b) The provision of additional capacity such as electrical, telephone, air handling, air conditioning etc. (c) Installation of approved modifications to the fire detection and emergency communication system. All work to modify the sprinkler layout of the premises to suit the Tenant s design can be undertaken by the Tenant; however the interface and modifications to the fire indicator panel must be undertaken by the landlord s fire contractor. (d) Design and installation of the ceiling sprinklers, EWIS, smoke detection devices and fire extinguishers based on the retail tenancy fit-out additional hydrants and/or hose reels may be required. Tenants should use the Landlord s designer and the Landlord s Contractor for the installation in order to minimize any problems with coordination of mechanical services with other trades (at Tenant s cost). (e) The Tenant is responsible for any false alarms and consequent charges from the Local Authorities caused by work on their behalf. Detectors must be isolated by a licensed service provider, protected and cleaned as required when work is being carried out. Detectors must also be cleaned on the completion of work or replaced if found faulty. All work is at the Tenant s cost. (f) Patching of base building fireproofing. (g) Any Tenant work which could affect the structural components of the building. (h) Any drilling, cutting, coring and patching for conduit, pipe sleeves, chases, duct equipment or openings or adjustments to the floors, walls, columns or roofs of the building as reviewed by the Structural consultant and approved by the Landlord. It should be noted that the Tenant must provide the Landlord with a fully dimensioned penetration layout. Dimensions are to relate to the building grid system. All Structural Engineering costs are the Tenant s responsibility. (i) Installation of any mechanical attachments or other fasteners to the exterior façade. (j) Supply and installation of meters. A sub-water meter will be provided by the Landlord at the Tenant s cost. (k) Modifications to tenancy plans based on a revised tenancy layout. THE POINTE RETAIL TENANT DESIGN MANUAL PAGE 26

RETAIL TENANT DESIGN CRITERIA MANUAL

RETAIL TENANT DESIGN CRITERIA MANUAL RETAIL TENANT DESIGN CRITERIA MANUAL Southern Cross East and Southern Cross West, Melbourne This Manual is subject to change from time to time It is critical to refer to the most current version 22 January

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW Sawgrass Mills is located on the Sawgrass Expressway (SR 869) just west of Ft. Lauderdale, FL. The center is less than 30 minutes from both Boca

More information

TENANT DESIGN MANUAL UPDATED JUNE 2015

TENANT DESIGN MANUAL UPDATED JUNE 2015 TENANT DESIGN MANUAL UPDATED JUNE 2015 PROJECT OVERVIEW Hamilton Town Center is located at the intersection of 146th Street (SR 238) and I-69 in Noblesville, IN. It s location in Hamilton County enables

More information

DESCRIPTION OF LANDLORD'S WORK & TENANT'S WORK

DESCRIPTION OF LANDLORD'S WORK & TENANT'S WORK DESCRIPTION OF LANDLORD'S WORK & TENANT'S WORK I. LANDLORD'S WORK Landlord's Work shall be done in accordance with the specifications set forth below, shall be limited to the work set forth in this Section

More information

TENANT DESIGN MANUAL UPDATED JUNE 2015

TENANT DESIGN MANUAL UPDATED JUNE 2015 TENANT DESIGN MANUAL UPDATED JUNE 2015 PROJECT OVERVIEW Northshore Mall is located at the intersection of Routes 114 and 128, just minutes from major thoroughfares US 1 and I-95. 2 PROJECT OVERVIEW As

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW Gurnee Mills is located at the intersection of I-94 and Grand Avenue (SR 132) in Lake County, Illinois. It is halfway between Chicago and Milwaukee.

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW Santa Rosa Plaza is located on US 101, between College Avenue and State Road 12, in Santa Rosa, just 55 miles north of San Francisco, in the heart

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW Colorado Mills is 10 miles west of downtown Denver at the intersection of I-70, Colfax Avenue and Indiana Avenue in popular Lakewood, CO. The center

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW Opened in 1997 and located just 10 miles southeast of downtown Phoenix, Arizona Mills is located at the intersection of US-60 and I-10, at the Arizona

More information

COLD DARK SHELL LEASE EXHIBIT

COLD DARK SHELL LEASE EXHIBIT COLD DARK SHELL LEASE EXHIBIT COLD DARK SHELL Lease Exhibit 1 EXHIBIT C Leasehold Improvements Work Letter I. ALL WORK TO BE PERFORMED HEREUNDER SHALL CONFORM TO CODE. CODE SHALL BE DEFINED FOR PURPOSES

More information

FOR LEASE. Capitol Hill Corner Cafe/Restaurant Space th Avenue, Seattle, WA Please call brokers for more information:

FOR LEASE. Capitol Hill Corner Cafe/Restaurant Space th Avenue, Seattle, WA Please call brokers for more information: FOR LEASE Capitol Hill Corner Cafe/Restaurant Space Cal Anderson Park Seattle Central College / Capitol Hill 1634 11th Avenue, Seattle, WA 98122 Light Rail 1.5 blocks 1634 11th Ave. New 6 story mixed-use

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW Arundel Mills is located at the intersection of SR 100 and the Baltimore/ Washington Parkway (Route 295) in Hanover, MD, just 10 miles south of Baltimore

More information

TENANT DESIGN MANUAL UPDATED OCTOBER 2016

TENANT DESIGN MANUAL UPDATED OCTOBER 2016 TENANT DESIGN MANUAL UPDATED OCTOBER 2016 PROJECT OVERVIEW Conveniently located just off US 65 (Glenstone Avenue) and just five miles south of I-44, Battlefield Mall is perfectly positioned to serve the

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW Katy Mills is located at the intersection of I-10 and Pin Oak Road, approximately 25 miles west of downtown Houston, in Katy, TX. 2 PROJECT OVERVIEW

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW Great Mall is located at the intersection of Montague Expressway and Great Mall Parkway in Milpitas, CA. It is approximately 50 miles from San Francisco

More information

EXHIBIT C. Leasehold Improvements Work Letter

EXHIBIT C. Leasehold Improvements Work Letter EXHIBIT C Leasehold Improvements Work Letter I. ALL WORK TO BE PERFORMED HEREUNDER SHALL CONFORM TO CODE. CODE SHALL BE DEFINED FOR PURPOSES HEREOF AS ALL FEDERAL, STATE, REGIONAL, COUNTY, MUNICIPAL AND

More information

TENANT DESIGN MANUAL UPDATED JUNE 2015

TENANT DESIGN MANUAL UPDATED JUNE 2015 TENANT DESIGN MANUAL UPDATED JUNE 2015 PROJECT OVERVIEW Solomon Pond Mall is a two-level super-regional mall located on Donald J. Lynch Boulevard, just off I-290 and I- 495, in Marlborough. The mall opened

More information

TENANT DESIGN MANUAL UPDATED JANUARY 2016

TENANT DESIGN MANUAL UPDATED JANUARY 2016 TENANT DESIGN MANUAL UPDATED JANUARY 2016 PROJECT OVERVIEW College Mall is located in Bloomington, Indiana and is the only regional mall in the market. It is home to Indiana University s flagship campus

More information

3435 MAIN 3435 Main Street Kansas City, MO RESTAURANT SPACE Available for Lease 1. BUILDING LOCATION

3435 MAIN 3435 Main Street Kansas City, MO RESTAURANT SPACE Available for Lease 1. BUILDING LOCATION 1. BUILDING LOCATION E. 34TH TERRACE MAIN STREET ARMOUR BLVD, at the corner of Main and 34th Terrace Restaurant Space - 2,238 SF, with 38 LF of Main Street frontage - On-site parking - Accomodation for

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW At the heart of the Orange Crush Interchange, The Outlets at Orange is located at the junction of The City Drive South and the Garden Grove Freeway

More information

Exhibit C - Shops 1 & 2

Exhibit C - Shops 1 & 2 Exhibit C - Shops 1 & 2 EXHIBIT "C" LANDLORD S WORK MOUNTAIN GROVE SHOPS (Revised 02/12/2013) Landlord agrees, at its sole cost and expense, to furnish and install the following "Landlord's Work", limited

More information

TENANT DESIGN MANUAL UPDATED FEBRUARY 2017

TENANT DESIGN MANUAL UPDATED FEBRUARY 2017 TENANT DESIGN MANUAL UPDATED FEBRUARY 2017 PROJECT OVERVIEW Montgomery Mall is located at the intersection of US 202 and SR 309 in the heart of Philadelphia s affluent northern suburbs. 2 PROJECT OVERVIEW

More information

TENANT DESIGN MANUAL UPDATED DECEMBER 2018

TENANT DESIGN MANUAL UPDATED DECEMBER 2018 TENANT DESIGN MANUAL UPDATED DECEMBER 2018 PROJECT OVERVIEW South Hills Village is located at US 19 (Washington Road) and Ft. Couch Road, in the Bethel Park suburb of Pittsburgh. 2 PROJECT OVERVIEW Anchored

More information

TENANT DESIGN MANUAL UPDATE JUNE 2015

TENANT DESIGN MANUAL UPDATE JUNE 2015 TENANT DESIGN MANUAL UPDATE JUNE 2015 PROJECT OVERVIEW IN THE HEART OF LONG ISLAND, NY, WALT WHITMAN SHOPS IS FOUND AT THE INTERSECTION OF THE JERICHO TURNPIKE (RT 25) AND WALT WHITMAN ROAD (RT 110). 2

More information

TENANT DESIGN MANUAL UPDATED JUNE 2015

TENANT DESIGN MANUAL UPDATED JUNE 2015 TENANT DESIGN MANUAL UPDATED JUNE 2015 PROJECT OVERVIEW Cape Cod Mall is located on Route 132 in Hyannis, the largest of seven towns in Cape Cod, MA. Hyannis is known as the Capitol of the Cape. 2 PROJECT

More information

a) Tenant shall require its Contractor to provide and maintain the following insurance coverage:

a) Tenant shall require its Contractor to provide and maintain the following insurance coverage: TENANTS WORK Tenant shall perform its work, at its sole cost and expense, in accordance with Landlord s criteria and all applicable code requirements. All Tenant Work shall be subject to Landlord s prior

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW Concord Mills is located 10 miles north of downtown Charlotte, at the intersection of Concord Mills Boulevard and I-85, in Concord, NC. It is just

More information

MASTER SIGN PROGRAM SERRA CENTER COLMA, CALIFORNIA. Approved by the Town of Colma City Council on March 22, 2017

MASTER SIGN PROGRAM SERRA CENTER COLMA, CALIFORNIA. Approved by the Town of Colma City Council on March 22, 2017 MASTER SIGN PROGRAM SERRA CENTER COLMA, CALIFORNIA Approved by the Town of Colma City Council on March 22, 2017 A. INTRODUCTION 1. The intent of this sign program is to provide the guidelines necessary

More information

TENANT DESIGN MANUAL UPDATED MAY 2016

TENANT DESIGN MANUAL UPDATED MAY 2016 TENANT DESIGN MANUAL UPDATED MAY 2016 PROJECT OVERVIEW Burlington Mall is located along I-95 at the Middlesex Turnpike Intersection in Burlington, Massachusetts. It is 12 miles northwest of downtown Boston

More information

TENANT DESIGN MANUAL UPDATED JUNE 2015

TENANT DESIGN MANUAL UPDATED JUNE 2015 TENANT DESIGN MANUAL UPDATED JUNE 2015 PROJECT OVERVIEW Castleton Square is located on East 82 nd Street and is adjacent to both I-465 and I-69 on the northeast side of Indianapolis. It also serves the

More information

TENANT DESIGN MANUAL UPDATED JULY 2016

TENANT DESIGN MANUAL UPDATED JULY 2016 TENANT DESIGN MANUAL UPDATED JULY 2016 PROJECT OVERVIEW South Shore Plaza is located at the intersection of Route 3 and I-93 in Braintree, MA. It is approximately 10 miles from historic downtown Boston

More information

RESIDENCES EFFORTLESS LUXURY IN ONE OF CANBERRA S MOST PRESTIGIOUS SUBURBS BY VILLAGE BUILDING CO. 15 CURLEWIS CRESCENT GARRAN

RESIDENCES EFFORTLESS LUXURY IN ONE OF CANBERRA S MOST PRESTIGIOUS SUBURBS BY VILLAGE BUILDING CO. 15 CURLEWIS CRESCENT GARRAN RESIDENCES BY VILLAGE BUILDING CO. EFFORTLESS LUXURY IN ONE OF CANBERRA S MOST PRESTIGIOUS SUBURBS 15 CURLEWIS CRESCENT GARRAN SITEPL AN NORTH CURLEWIS CRESCENT 15A 15B Conveniently located in the established,

More information

Construction Document Criteria

Construction Document Criteria Construction Document Criteria Introduction Information contained in this section has been assembled to assist the architect and the architect's consultants in preparation of Construction Documents and

More information

TENANT DESIGN CRITERIA Section s Signage Updated: March 2018

TENANT DESIGN CRITERIA Section s Signage Updated: March 2018 SIGNGE CRITERI s1 s2 TENNT DESIGN CRITERI STOREFRONT SIGNGE CRITERI General The following outlines the work to be provided by the tenant. Tenant signage shall be designed, fabricated and installed by the

More information

TENANT STOREFRONT SIGNAGE CRITERIA

TENANT STOREFRONT SIGNAGE CRITERIA TENANT STOREFRONT SIGNAGE CRITERIA DEERFOOT MEADOWS CALGARY ALBERTA 33 Heritage Meadows Way SE Calgary, AB T2H 3B3 1 General Requirements The purpose of this is to provide all of the tenants of the Deerfoot

More information

General Information RETAIL AND RESTAURANT

General Information RETAIL AND RESTAURANT General Information RETAIL AND RESTAURANT Landlord s Tenant Coordinator The role of the Tenant Coordinator is to serve as liaison between Landlord and the Tenant, Tenant's architect and Tenant's contractor.

More information

TENANT DESIGN MANUAL UPDATED JUNE 2016

TENANT DESIGN MANUAL UPDATED JUNE 2016 TENANT DESIGN MANUAL UPDATED JUNE 2016 PROJECT OVERVIEW The Shops at Chestnut Hills is located is located along State Route 9 (Boylston Street) and Hammond Pond Parkway in the heart of Chestnut Hills.

More information

TENANT DESIGN MANUAL UPDATED FEBRUARY 2017

TENANT DESIGN MANUAL UPDATED FEBRUARY 2017 TENANT DESIGN MANUAL UPDATED FEBRUARY 2017 PROJECT OVERVIEW Pier Park is an approximately 1.1 million square feet combination town/ community/lifestyle center located in the heart of Panama City Beach

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW St. Charles Towne Center is a two-level super-regional mall located at the intersection of Smallwood Drive and US 301, in Waldorf, Maryland, just

More information

Residencial El Prado - "Viviendas desde *. Plaza y Trastero Incluido" Ensanche de Vallecas (caseta nº 1)

Residencial El Prado - Viviendas desde *. Plaza y Trastero Incluido Ensanche de Vallecas (caseta nº 1) A NEW CITY IN MADRID El Prado residential complex is located in Madrid, in a new area that will soon be considered as one of the most important residential areas in the autonomous community, the place

More information

TENANT DESIGN MANUAL UPDATED AUGUST 2015

TENANT DESIGN MANUAL UPDATED AUGUST 2015 TENANT DESIGN MANUAL UPDATED AUGUST 2015 PROJECT OVERVIEW JCPenny Nordstrom Macy s Lord & Taylor Sears WOODFIELD MALL 2 PROJECT OVERVIEW The largest shopping center in the state of Illinois and one of

More information

PLAZA WEST COVINA TENANT DESIGN & CONSTRUCTION CRITERIA PROPERTY SPECIFIC REQUIREMENTS

PLAZA WEST COVINA TENANT DESIGN & CONSTRUCTION CRITERIA PROPERTY SPECIFIC REQUIREMENTS PLAZA WEST COVINA TENANT DESIGN & CONSTRUCTION CRITERIA PROPERTY SPECIFIC REQUIREMENTS 1 TABLE OF CONTENTS 1.0 PROPERTY INTRODUCTION...3 1.1 Base Building Information 1.2 Contact Information 1.3 Vicinity

More information

Common Areas and Building Finishes

Common Areas and Building Finishes UNIT TYPES 2A, 2B, 2C, 2D, 2E & 2F Common Areas and Building Finishes EXTERNAL WALLS S LANDSCAPING Reinforced concrete (off-form and painted finish) / glazing / aluminium/ aluminium composite panel / block

More information

TENANT DESIGN MANUAL UPDATED JUNE 2015

TENANT DESIGN MANUAL UPDATED JUNE 2015 TENANT DESIGN MANUAL UPDATED JUNE 2015 PROJECT OVERVIEW Found in the heart of the prestigious Mission Valley area of San Diego, CA, Fashion Valley is located at Friars Road and Highway 163. It is adjacent

More information

1. PRESENTATION OF THE PROJECT

1. PRESENTATION OF THE PROJECT 1. PRESENTATION OF THE PROJECT Luxury chalets - Alpe d Huez LOCATION The project is located at the highest point of the Alpe d Huez resort, beside the ski slopes and opposite the Grandes Rousses mountain

More information

TENANT DESIGN MANUAL UPDATED JUNE 2015

TENANT DESIGN MANUAL UPDATED JUNE 2015 TENANT DESIGN MANUAL UPDATED JUNE 2015 PROJECT OVERVIEW Mall of Georgia is located on SR 20 (Buford Drive) in the Mill Creek District of Gwinnett County, Georgia. It is 30 miles northeast of Atlanta. 2

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW The Domain is located on MOPAC Expressway (Loop 1), near the intersection of Highway 183 and Capitol of Texas Highway (Loop 360). The center originally

More information

ACCESSORY DWELLING UNITS

ACCESSORY DWELLING UNITS ACCESSORY DWELLING UNITS Category: Residential Construction Revised: [Paul L. Scarlett], Director Responsible Bureau Sections: Development Services Center 1900 SW Fourth Avenue Portland, OR 97201 503-823-7310

More information

SIGNS MASTER SIGN PROGRAM

SIGNS MASTER SIGN PROGRAM SIGNS MASTER SIGN PROGRAM How to apply for a Master Sign Program What is the purpose of a Master Sign Program? A Master Sign Program (MSP) is used to create standard sign design guidelines for projects

More information

Apartment Lifts There are individual lifts dedicated to the Building. Security lifts to all levels including car park.

Apartment Lifts There are individual lifts dedicated to the Building. Security lifts to all levels including car park. Atrium Building components The major components of the building consist of the following: Entry lobby The entry lobby will consist of paint finish walls and ceilings, tiled externally and internally, glass

More information

TENANT DESIGN MANUAL UPDATED OCTOBER 2016

TENANT DESIGN MANUAL UPDATED OCTOBER 2016 TENANT DESIGN MANUAL UPDATED OCTOBER 2016 PROJECT OVERVIEW Bangor Mall is conveniently located off exits 186 and 187 on I-95, the only major highway that runs north and south in the state, providing easy

More information

SDA APARTMENTS AT ARATI INTRODUCTION

SDA APARTMENTS AT ARATI INTRODUCTION APARTMENTS AT ARATI INTRODUCTION A TOTAL OF 12 APARTMENTS, ARATI S LATEST AND LAST PART OF DEVELOPMENT WILL HAVE SINGLE, COUPLE AND FAMILY HOMES WITH SPACIOUS FLOOR PLANS RANGING BETWEEN 52 AND 116 SQM

More information

Lone Tree Landing Hillcrest Ave & Lone Tree Way Antioch, CA

Lone Tree Landing Hillcrest Ave & Lone Tree Way Antioch, CA Lone Tree Landing Hillcrest Ave & Lone Tree Way Antioch, CA Sign Criteria Multi Tenant and Freestanding Commercial Prepared By: Charity Bowman June 3, 2008 United Sign Systems 5201 Pentecost Drive Modesto,

More information

OVERALL SIGN PLAN May 12, 2014

OVERALL SIGN PLAN May 12, 2014 HOLLISTER VILLAGE PLAZA APARTMENT COMMUNITY 100 BALDWIN DRIVE GOLETA, CALIFORNIA May 12, 2014 GOLETA HOLLISTER LLC c/o WESTAR MANAGEMENT INC. 2925 SOUTH BRISTOL ST. COSTA MESA, CA 92626 714-241-0400 HOLLISTER

More information

The Promenade at Casa Grande 1005 N Promenade Pkwy Casa Grande, AZ 85294

The Promenade at Casa Grande 1005 N Promenade Pkwy Casa Grande, AZ 85294 ADDENDUM LOG August, 2011 Manual generated September, 2011 Waterproof membrane requirement updated March, 2014 Distribution of utilities through exit corridors is prohibited with exception (t11) October,

More information

ADAPTABLE DESIGN GUIDELINES

ADAPTABLE DESIGN GUIDELINES ADAPTABLE DESIGN GUIDELINES Adaptable design creates liveable residences for a wider range of persons than current building codes require. By considering design features that can be easily and inexpensively

More information

Janet Campbell Howard Hanna Real Estate Services. 85 South Union Street Main Line: (585) Spencerport NY Office Fax: (585)

Janet Campbell Howard Hanna Real Estate Services. 85 South Union Street Main Line: (585) Spencerport NY Office Fax: (585) Quality Built Homes By: Iuppa Homes Inc. Rich Iuppa Builder & Howard Hanna Real Estate Services Spencerport Office Janet Campbell Broker Associate Office: (585)-352-8524 Cell: (585)-739-8065 Subdivision

More information

Common Areas and Building Finishes

Common Areas and Building Finishes 2 BEDROOM APARTMENTS Common Areas and Building Finishes EXTERNAL WALLS S LANDSCAPING Reinforced concrete (off-form and painted finish) / glazing / aluminium/ aluminium composite panel / block and render

More information

Contemporary villas Panoramic view 3 minutes from Bonita Beach

Contemporary villas Panoramic view 3 minutes from Bonita Beach Contemporary villas Panoramic view 3 minutes from Bonita Beach 4 individual villas with private pool - 3 bedrooms + optional studio Situated on a 4000 square meter terrain VILLAS AUM 3 or 4 bedroom villas,

More information

SCHEDULE B. Comprehensive Mixed Use Sign and Awning Package Replacing Section VI.P.3 of the Redevelopment Plan As amended January 22, 2013

SCHEDULE B. Comprehensive Mixed Use Sign and Awning Package Replacing Section VI.P.3 of the Redevelopment Plan As amended January 22, 2013 SCHEDULE B Comprehensive Mixed Use Sign and Awning Package Replacing Section VI.P.3 of the Redevelopment Plan As amended January 22, 2013 3. Mixed Use District a. All dwellings shall clearly display the

More information

SOPHISTICATED, RELAXED LIVING.

SOPHISTICATED, RELAXED LIVING. SOPHISTICATED, RELAXED LIVING. 36 SPAFFORD CRESCENT FARRER As the latest edition to our exclusive townhouse collection, 36 Spafford Crescent, Farrer, features two stunning architecturally designed homes

More information

Common Areas and Building Finishes

Common Areas and Building Finishes Common Areas and Building Finishes EXTERNAL WALLS Reinforced concrete / glazing / precast / block and render to Architect s detailed S LANDSCAPING Reinforced concrete suspended slab To Landscape CORRIDORS

More information

TECHNICAL CRITERIA ARROWHEAD TOWNE CENTER THE PLACE TO SHOP

TECHNICAL CRITERIA ARROWHEAD TOWNE CENTER THE PLACE TO SHOP TECHNICAL CRITERIA THE PLACE TO SHOP ADDENDUM LOG May, 2009 TCM Generated/Layout Updated June, 2009 Updated with TC comments September, 2011 Waterproof membrane requirement updated February, 2012 Updated

More information

SMITH DOUGLAS H OMES P RE SENT S HIGHLANDS AT MADISON PARK BASE PRICE SHEET. The Benson 3 Beds / 2.5 Baths Approx 1,801 Sq. Ft.

SMITH DOUGLAS H OMES P RE SENT S HIGHLANDS AT MADISON PARK BASE PRICE SHEET. The Benson 3 Beds / 2.5 Baths Approx 1,801 Sq. Ft. BASE PRICE SHEET The Benson 3 Beds / 2.5 Baths Approx 1,801 Sq. Ft. See Pricing Below The Benson A $221,900 The Benson E $221,900 The Benson B $219,900 The Benson F $217,900 The Benson D $218,900 The Campbell

More information

VINEYARD & VENTURA SHOPPING CENTER

VINEYARD & VENTURA SHOPPING CENTER Exhibit "_" VINEYARD & VENTURA SHOPPING CENTER 2600 E. Vineyard Blvd. OXNARD, CA MASTER SIGN PROGRAM July 24, 2013 LESSOR OXNARD VINEYARDS, LLC LESSEE \\TWLA-SERVER\Projects\Vineyard & Ventura\Project

More information

OBTAINING A CERTIFICATE OF OCCUPANCY FOR UNAPPROVED DWELLING UNITS

OBTAINING A CERTIFICATE OF OCCUPANCY FOR UNAPPROVED DWELLING UNITS OBTAINING A CERTIFICATE OF OCCUPANCY FOR UNAPPROVED DWELLING UNITS A 2008 City Code amendment requires the owners of all rental dwelling units in the city to have a certificate of occupancy (CO) before

More information

Procedures on Maintenance Services and. Required Inspections for the ADR Tenants. Seattle Tacoma International Airport.

Procedures on Maintenance Services and. Required Inspections for the ADR Tenants. Seattle Tacoma International Airport. AIRPORT DINING & RETAIL PREVENTIVE MAINTENANCE PROGRAM MANUAL 2018 Procedures on Maintenance Services and Required Inspections for the ADR Tenants Seattle Tacoma International Airport 2018 edition TABLE

More information

TENANT DESIGN MANUAL UPDATED AUGUST 2016

TENANT DESIGN MANUAL UPDATED AUGUST 2016 TENANT DESIGN MANUAL UPDATED AUGUST 2016 PROJECT OVERVIEW Ingram Park Mall is located in the northwest suburbs of San Antonio, Texas, the seventh largest city in the United States. The center is strategically

More information

Common Areas and Building Finishes

Common Areas and Building Finishes Common Areas and Building Finishes EXTERNAL WALLS Reinforced concrete / glazing / precast / block and render to Architect s detailed design S LANDSCAPING Reinforced concrete suspended slab To Landscape

More information

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS Prepared by: Community Development Standards Branch Town of Innisfil www.innisfil.ca June 2016 Contents 1. Introduction... 1 2. Ontario Building

More information

Submission Procedures

Submission Procedures Submission Procedures - The term Tenant may also be used to imply Tenant s Consultants, Contractors, or other Tenant representatives. - Store Design Drawings may also be referred to as Design Drawings

More information

Design and Construction Document Criteria

Design and Construction Document Criteria CHARLESTON PLACE Design and Construction Document Criteria I. ARCHITECTURAL AND FINISHES: ALL WORK BY TENANT UNLESS OTHERWISE NOTED A. Floors 1. All slabs on grade shall be minimum 4" thick with minimum

More information

ACCESSORY DWELLING UNITS

ACCESSORY DWELLING UNITS ACCESSORY DWELLING UNITS Category: Residential Construction Revised: [Paul L. Scarlett], Director Responsible Bureau Sections: Development Services Center 1900 SW Fourth Avenue Portland, OR 97201 503-823-7310

More information

San Tan Village 2218 E. Williams Field Rd. #235, Gilbert, AZ 85295

San Tan Village 2218 E. Williams Field Rd. #235, Gilbert, AZ 85295 ADDENDUM LOG December, 2009 Updated to current layout January, 2010 Revised per TC AVP Comments September, 2011 Waterproof membrane requirement updated March, 2014 Distribution of utilities through exit

More information

GENERAL INFORMATION. Landlord s Tenant Coordinator

GENERAL INFORMATION. Landlord s Tenant Coordinator GENERAL INFORMATION Landlord s Tenant Coordinator The role of the Tenant Coordinator is to serve as liaison between Landlord and the Tenant, Tenant's architect and Tenant's contractor. All plans and correspondence

More information

SOUTHLAKE MALL. Southlake Mall Tenant Design & Construction Criteria TENANT DESIGN & CONSTRUCTION CRITERIA PROPERTY SPECIFIC REQUIREMENTS

SOUTHLAKE MALL. Southlake Mall Tenant Design & Construction Criteria TENANT DESIGN & CONSTRUCTION CRITERIA PROPERTY SPECIFIC REQUIREMENTS SOUTHLAKE MALL TENANT DESIGN & CONSTRUCTION CRITERIA PROPERTY SPECIFIC REQUIREMENTS 1 TABLE OF CONTENTS 1.0 PROPERTY INTRODUCTION...3 1.1 Base Building Information 1.2 Contact Information 1.3 Vicinity

More information

CHAPTER 4 LIGHT, VENTILATION & OCCUPANCY LIMITATIONS

CHAPTER 4 LIGHT, VENTILATION & OCCUPANCY LIMITATIONS CHAPTER 4 LIGHT, VENTILATION & OCCUPANCY LIMITATIONS Chapter 4 establishes the minimum criteria for light and ventilation and identifies occupancy limitations. * Indicates code is still under review for

More information

14400 Bear Valley Road, Victorville, CA 92392

14400 Bear Valley Road, Victorville, CA 92392 ADDENDUM LOG January, 2008 Entire Criteria Manual January, 2009 Full update March, 2009 Contact revisions/additions July, 2009 Revised full update June, 2011 Plumbing content updated to include Seismic

More information

TENANT DESIGN CRITERIA V. Technical Criteria 34

TENANT DESIGN CRITERIA V. Technical Criteria 34 TECHNICAL CRITERIA Electrical Landlord shall furnish a main electrical service disconnect fusible switch and a telephone backboard at a central distribution point located within Landlord s main electrical

More information

AIRPORT DINING & RETAIL PREVENTIVE MAINTENANCE PROGRAM MANUAL

AIRPORT DINING & RETAIL PREVENTIVE MAINTENANCE PROGRAM MANUAL AIRPORT DINING & RETAIL PREVENTIVE MAINTENANCE PROGRAM MANUAL Procedures on Maintenance Services and Required Inspections for the ADR Tenants Seattle Tacoma International Airport 2017 edition TABLE OF

More information

TRIALLIANCE COMMERCIAL REAL ESTATE SERVICES COLUMBIA STATION Route 108, Old Annapolis Road Columbia, MD 21045

TRIALLIANCE COMMERCIAL REAL ESTATE SERVICES COLUMBIA STATION Route 108, Old Annapolis Road Columbia, MD 21045 TRIALLIANCE COMMERCIAL REAL ESTATE SERVICES COLUMBIA STATION 9123 Route 108, Old Annapolis Road Columbia, MD 21045 RETAIL/OFFICE/MEDICAL/EXECUTIVE SUITES OFFERED FOR LEASE PROPERTY IDENTIFICATION: ADDRESS:

More information

Renovations Information

Renovations Information Renovations Information Renovations to a Lot When proposing to undertake renovations to a lot, the lot owners should review this factsheet and we suggest you complete an application form and checklist.

More information

THE PLACE TO SHOP TOWNE MALL

THE PLACE TO SHOP TOWNE MALL G E N E R A L I N F O R M AT I O N C R I T E R I A THE PLACE TO SHOP ADDENDUM LOG November, 2009 Updated to current layout December, 2009 Revised per TC AVP comments January, 2011 TC contact info updated

More information

Internal Finishes. Floor Finishes. Mouldings. Wall Finishes. Paint Finish

Internal Finishes. Floor Finishes. Mouldings. Wall Finishes. Paint Finish Specifications Structure / External Floors Ground Floor Apartment Floors Concrete slab Suspended Concrete Slab Walls External Walls Internal Walls Party Walls Combination of Plasterboard or Selected Concrete

More information

Apartment , Ver A

Apartment , Ver A Apartment 18 495,000 25.11.18 Ver A 26-11-18 Apartments 8 to 20, New Build KITCHEN Omega kitchen from the Mackintosh range with feature under pelmet lighting. Laminate worktop with 100mm upstand. 1½

More information

LEGEND. A Apartments. T Townhouses

LEGEND. A Apartments. T Townhouses flagship house N LATITUDE HOUSE MARITIME BUILDING A T T RIVERSIDE WALK A A T RIVER THAMES A T LEGEND A Apartments T Townhouses BARRIER HOUSE FLAGSHIP HOUSE ADMIRALTY BUILDING ANCHOR BUILDING Sovereign

More information

Tenant Design Criteria Section t Technical Criteria Updated: August Wilton Mall at Saratoga 3065 Route 50, Saratoga Springs, NY 12866

Tenant Design Criteria Section t Technical Criteria Updated: August Wilton Mall at Saratoga 3065 Route 50, Saratoga Springs, NY 12866 Wilton Mall at Saratoga TABLE OF CONTENTS TECHNICAL CRITERIA Electric / Water Sub-meter Requirements t3 Wilton Mall at Saratoga ADDEMDUM August, 2016 Added information regarding all sanitary lines must

More information

THE PLACE TO SHOP CHANDLER FASHION CENTER

THE PLACE TO SHOP CHANDLER FASHION CENTER G E N E R A L I N F O R M AT I O N C R I T E R I A THE PLACE TO SHOP ADDENDUM LOG June, 2009 TCM Generated July, 2011 Required Contractor info updated August, 2011 TC information updated December, 2011

More information

WASHINGTON SQUARE SIGNAGE PROGRAM - EXHIBIT 1

WASHINGTON SQUARE SIGNAGE PROGRAM - EXHIBIT 1 VACANT WASHINGTON SQUARE SIGNAGE PROGRAM - EXHIBIT 1 Number of Businesses 39 Number of Businesses x 100 sf 3900 A Pylon sign area sf 152 B Number of Businesses x 20 780 C Aggregate Sign Area 2968 D=A-B-C

More information

2018 CSBC / 2018 CSFSC Part III. Chapter #10. Means of Egress. Table of Contents. Based on the 2015 IBC and the 2015 IFC.

2018 CSBC / 2018 CSFSC Part III. Chapter #10. Means of Egress. Table of Contents. Based on the 2015 IBC and the 2015 IFC. 2018 CSBC / 2018 CSFSC Part III. Chapter #10. Means of Egress. Table of Contents. Based on the 2015 IBC and the 2015 IFC. October 23, 2018 Section 1001. Administration. See Section 107.2.3 for Egress Drawing

More information

TECHINICAL CRITERIA DEPTFORD MALL THE PLACE TO SHOP

TECHINICAL CRITERIA DEPTFORD MALL THE PLACE TO SHOP TECHINICAL CRITERIA THE PLACE TO SHOP TABLE OF CONTENTS PLEASE VISIT WWW.MACERICH.COM TO VIEW PLAN SUBMITTAL & APPROVAL PROCEDURES and CONTRACTOR RULES & REGULATIONS TECHNICAL CRITERIA Electric / Water

More information

LOUIS JOLIET MALL TENANT DESIGN & CONSTRUCTION CRITERIA PROPERTY SPECIFIC REQUIREMENTS

LOUIS JOLIET MALL TENANT DESIGN & CONSTRUCTION CRITERIA PROPERTY SPECIFIC REQUIREMENTS LOUIS JOLIET MALL TENANT DESIGN & CONSTRUCTION CRITERIA PROPERTY SPECIFIC REQUIREMENTS TABLE OF CONTENTS 1.0 PROPERTY INTRODUCTION...3 1.1 Base Building Information 1.2 Contact Information 1.3 Project

More information

129 Washington Street, Woburn, MA

129 Washington Street, Woburn, MA 9 Washington Street, Woburn, MA New Construction Approx.,800 sf Cape Home New Construction 3bdrm &/ bath Split-Gambrel w/walk out basement. Enjoy the convenience, energy efficiency & low maintenance of

More information

Residencial Illes Medes Avda. del Garraf s/n,

Residencial Illes Medes Avda. del Garraf s/n, Come to live on your island Who has not dreamed about living on a desert island, a small private paradise where there is peace and equilibrium, where we can be ourselves with nobody to bother us? But on

More information

Residencial Bola de Oro - Edificio San Remo C/ Cerro de los Machos,

Residencial Bola de Oro - Edificio San Remo C/ Cerro de los Machos, A balcony overlooking Granada Get ready to enjoy one of the best views of Granada. Get ready for the San Remo Building in the exclusive area of Bola de Oro, where you will be surrounded by peace and quiet

More information

FICO Realty Group Presents 485 Washington Street Woburn MA 01801

FICO Realty Group Presents 485 Washington Street Woburn MA 01801 FICO Realty Group Presents 485 Washington Street Woburn MA 01801 TO BE BUILT! 485 Washington St. Woburn MA 01801 is a beautiful 8 Room, 4 Bedroom, 2 1/2 Bath, Colonial. Very close to the Reading line.

More information

QHOChomes.com. our Standard Features

QHOChomes.com. our Standard Features our Standard Features Excellent Exteriors Low maintenance vinyl siding Exterior cornice wrapped in aluminum with decorative bend Decorative raised panel vinyl shutters on front windows (per plan/elevation)

More information

Alley Load Garage Plans

Alley Load Garage Plans Alley Load Garage Plans Jim Fox, Ph.D. Realtor Cell: (208) 704-1723 Fax: (208) 762-4488 Email: jimfoxhomes@windermere.com Bret Minzghor Realtor Cell: (208) 704-2310 Fax: (208) 762-4488 Email: bminz@innocent.com

More information

Residencial Galera Playa - Edificios Fragata y Balandro Camino de La Galera,

Residencial Galera Playa - Edificios Fragata y Balandro Camino de La Galera, An up-to-date beachfront city Perfectly finished apartments with quality materials are some of the advantages of living in Galera Playa. An exclusive facility that will look after every minimal aspect

More information

LAKESIDE URBAN HOUSES

LAKESIDE URBAN HOUSES READING, BERKSHIRE THE SANFORD AND THE HANOVER LAKESIDE URBAN HOUSES LAKESIDE URBAN HOUSES A NEW CONCEPT Carefully considered design for modern 21st century living. Flexible, elegant spaces delivered to

More information