Page POWER SUPPLIES DIN RAIL MOUNT VERSION Single, two and three phase Output voltage: 24 or 48VDC Output power: W.

Similar documents
HIPOWER LOAD CENTER DESCRIPTION

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Classification Contact form Model #250 tab terminals/pcb coil terminals SPST-NO G4A-1A-E PCB terminals/pcb coil terminals

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Ordering Information. Slim, Miniature Relay with 1-pole 5-A Switching Capability G6DS - - VDC

SPDT Open frame G8P-1CTP. Flange mount Quick SPST-NO Vented G8P-1A2T-F SPDT Vented G8P-1C2T-F

CLAMP ON AC CURRENT PROBE

SAI distributor with plug in connection hood: SAI-M

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A. SPST-NO (Class F) Flux protection G5LA-1A-CF

Type Terminal Coil Contact form Model

INDUSTRIAL CONNECTOR GUIDE

Surface mounting, flush mounting, and DIN track mounting

Ordering Information. Specifications. Miniature Automotive PCB Relay G8QN/G8QW. Typical Applications. Contact Data. Coil Ratings (at 20 C)

Ordering Information. PCB Relay G5LB. Model Number Legend. Subminiature, Single-pole 10A Power Relay. 634 PCB Relay G5LB

About Melemco.

RoHS. Specifications. Part Number Configurator

Ordering Information. Snap Action Switch V. Thermoset Material. General Purpose Snap Action Switch. Snap Action Switch V 1

M8 / M12 CONNECTOR SYSTEM

Lutron Stairwell Fixture Solutions

Anemomaster

Installation and Operating Instructions

Classification Contact form Enclosure ratings Model Standard SPST-NO Flux protection G5PA-1

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

D2SW-3L1HS D2SW-01L1HS

Apeiron LTE+ / E12 Power Box LED Downlight System For Elevators. Installation Guide

PRICE LIST 2015 PR PULSION SYSTEMS

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

GTSYSTEM Video Multi-Tenant System


LC Engineering Services Pte Ltd

DOMESTIC ELECTRICAL INSTALLATION PERIODIC INSPECTION REPORT (FOR A SINGLE DWELLING)

LC Engineering Services Pte Ltd

International Gas Union Research Conference 2014 Development of New Model Residential PEMFC micro-chp Systems

Ordering Information. Tactile Switch B3W. Tactile Switch with Sealed Construction for Automatic Soldering. Tactile Switch B3W 1

Tables and worktop extensions

Operation angle Return angle Output rating Operating voltage Model 40 to to VDC 2.4 to 3.6 VDC D6BN-1P = 3)

MGN1A SPST-NO-DM MGN1X SPST-NO. MGN1AM (See note) SPST-NC DPST-NO

Operation angle Return angle Output rating Operating voltage Model 45 to to VDC 2.7 to 3.3 VDC D6B-2 (P) = 3)

REQUEST FOR PROPOSALS FOR SUBSTATION ENGINEERING SERVICES REBUILD OF TYGH VALLEY AND NEW CONSTRUCTION OF EASTSIDE SUBSTATIONS

V-Line Gen5 LTE S2195. Installation Guide

Electrical Safety Statutes and Regulations May 2018 Labor Standards and Safety Division Mechanical Inspection

18 V CORDLESS HYDRAULIC CRIMPING TOOL B500E KV

Screw-Cover, Type 1. Standard Product Screw-Cover Type 1 Pull Boxes with Knockouts

Mission Profile Based Analysis Tool for Reliability Studies

Installation of photovoltaic technology SMART WIRE power of 80,25kWp, located on the roofs INTEMO S.A..

Modular 6-Way Valve Series Characterized Valve for Hydronic Applications Technical Document

POWER SUPPLY CONNECTION / CS3 APPLICATION PROCEDURES & GUIDELINES FOR NON-CONTESTABLE CONSUMER INSTALLATION

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

ELECTRICAL SERVICE PANEL REPORT LONG SEASIDE FARMS. April 24, 2012

18.0 V CORDLESS HYDRAULIC CRIMPING TOOL B1300L CE

(B3U-1000 Series) Operating force (OF) 153 ± 50 gf 162 ± 50 gf MΩ min. (at 100 VDC)

Exposure assessment of magnetic field in dwellings with built-in transformers in Bulgaria

Type of rotor Top-actuated, flat Top-actuated, extended shaft Tube Embossed taping Tube Embossed taping. Quantity per tube

Modular 6-Way Valve Series Characterized Valve for Hydronic Applications Technical Document

THE MTA IS ACCEPTING INFORMAL BIDS FOR THE SALE OF SURPLUS TRANSFORMERS, ELECTRIC SWITCHES AND BREAKERS (SEE ATTACHED PHOTOS)

7.3 x 6.5 mm General-purpose: 160 g B3W-1050 B3W-1050S B3W-1150 B3W-1150S. 4.3 x 6.5 mm General-purpose: 200 g B3W-4000 B3W-4000S B3W-4100 B3W-4100S

TENANT DESIGN MANUAL UPDATED DECEMBER 2018

System furniture. Essentiel BENCH

LED Lamps. editionfive....life is brighter

adjustable height mechanisms

Research challenges for offshore HVDC grids and its components

GT Series. Multi-Tenant Entry Security

Guideline: Distribution Pole to Pillar

Underfloor. Heating Kits

TENANT DESIGN MANUAL UPDATED JULY 2015

ADAMS-COLUMBIA ELECTRIC COOPERATIVE SERVICE RULES AND REGULATIONS. Board Approved 11/30/16 Effective 1/2/17

OTERO COUNTY ELECTRIC COOPERATIVE, INC FOURTH REVISED RULE NO. 15 CANCELING THIRD REVISED RULE NO. 15 EXTENSION POLICY.

GUJARAT STATE ELECTRICITY CORPORATION LIMITED

Service Rules Canoochee EMC

Exhibit C - Shops 1 & 2

TENANT DESIGN MANUAL UPDATED AUGUST 2016

Creating Procurement Contracts

T-MAC CYLINDERS, INC.

TENANT DESIGN MANUAL UPDATED JULY 2015

Interconnection Checklist For Customer-owned Renewable Generation Systems (RGS)

ACTIVAN SPARE PARTS PARTS DIAGRAMS

WinTar-Tenant Accts Receivable User' s Guide

STCP 26-1 Issue 001 Active Network Management

Emil Møllers Gade 41 Horsens, Denmark

UL 870 Listed; File No. E27524 NEMA/EEMAC Type 12 JIC standards EGP and EMP CSA, File No , Type 1 IEC 60529, IP54

SCOPE OF WORK. 2. The company reserves the right to reject any one of the offers without assigning any reason.

Low Voltage Products

INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE JADAVPUR, KOLKATA Price Bid as per NIT No. IACS/WS/ELECT/ /72, Dated: 03/12/2018

TENANT DESIGN MANUAL UPDATED JANUARY 2016

USER MANUAL EN IN Abdominal Trainer insportline AB Lifter Easy

TENANT DESIGN MANUAL UPDATED FEBRUARY 2017

Mobile and Tablet. Ready

Actuator Actuator mounting position Contact type Model Pin plunger SPST-NC D3M-01

DEMCO Distributed Generation Procedures and Guidelines Manual for Members

Kvadrat Soft Cells Installation guide

Electronic Control Systems Vansco Standard Products. Catalog HY /US North American Product Offering

VILLE DE / TOWN OF BEAUMONT

TENANT DESIGN MANUAL UPDATED JUNE 2015

Installation and Operating Instructions

BUI L DIN G A ND E L E V A T O R F E ES

Facilities providing accommodation for the public (e.g. Hotels, hostels, guesthouses, self catering apartments).

Underground Electric Distribution Systems for Developments DATE CREATED: 10/01/85 REVISED: 10/14/14

B. G E N E R A L L A N D L O R D / T E N A N T REQUIREMENTS

GUJARAT STATE ELECTRICITY CORPORATION LIMITED

Transcription:

Page -2 POWER SUPPIES MODUAR AD DI RAI MOUT VERSIOS Single phase Output voltage: 12 or 24VDC Output power: 10...100W. Page -3 POWER SUPPIES DI RAI MOUT VERSIO Single, two and three phase Output voltage: 24 or 48VDC Output power: 5...0W. REDUDACY MODUES Modular and 35mm DI rail mount Output voltage: 12 or 24VDC Output current: 10 or 20A. Page -3

SWITCHIG POWER SUPPIES Versions: modular and 35mm DI rail mount Output voltage adjustment by front potentiometer Short-circuit protection Built-in input voltage surge suppressor Used as power supply for DC electromechanical and electronic equipment Redundancy modules Modular switching power supplies SEC. - PAGE Single phase... - 2 DI rail mount switching power supplies Single phase... - 3 Two phase... - 3 Three phase... - 3 Redundancy modules... - 3 Dimensions... - 4 Wiring diagrams... - 5 Technical characteristics... - 6 AUTOMATIO AD COTRO

DI rail mount Modular version PS1M 010... PS1M 033 12 PS1M 036 24 Order code Rated Rated Output Qty Wt output output power per voltage current pkg [V] [A] [W] n [kg] Single phase. PS1M 010 12 12VDC 0.83 10 1 0.114 PS1M 024 12 2 24 1 0.177 PS1M 033 12 2.75 33 1 0.248 PS1M 054 12 4.5 54 1 0.311 PS1M 072 12 6 72 1 0.3 PS1M 010 24 24VDC 0.42 10 1 0.114 PS1M 024 24 1 24 1 0.177 PS1M 036 24 1.5 36 1 0.248 PS1M 060 24 2.5 60 1 0.311 PS1M 100 24 4.2 100 1 0.3 General characteristics Switching power supplies transform an AC input voltage into a DC output one. This type of equipment is used in industrial and domestic automation fields. The power supplies are equipped with switching technology offering very high efficiency in an extremely compact size. Dimensions are compatible with modular consumer panels and its plastic housing is suitable for building automation installations as well as industrial automation applications. The wide range of power supply voltages and the choice of DC current outputs provide for the best adaptability to supply voltage needs of the most common electronic and electromechanical devices. Protections: Short circuit Overload Input voltage peaks. Indications: ED indicator for low voltage conditions ED indicator for power on. Operational characteristics Rated supply voltage: Rated output voltage: 12VDC for PS1M...12 types; 24VDC for PS1M...24 types Mains frequency: 50/60Hz Output voltage adjustment by front potentiometer High efficiency up to 89% 35mm DI rail (IEC/E 60715) mounting Screw connection terminals Modular DI 43880 housing; number of modules: 1 for PS1M 010... 2 for PS1M 024... 3 for PS1M 033 12 and PS1M 036 24 4 for PS1M 054 12 and PS1M 060 24 5 for PS1M 072 12 and PS1M 100 24 IEC degree of protection: IP20 on terminals. Certifications and compliance Certifications obtained: EAC; U isted for USA and Canada (cuus-file E318016) as Power Supplies in power circuit and motor-mounted apparatus category. Compliant with standards: IEC/E 60950-1, IEC/E 61000-6-2, IEC/E 61000-6-3, U508, CSA C22.2 n 107-1. -2 Dimensions page -4 Wiring diagrams page -5 Technical characteristics page -6

DI rail mount. Redundancy modules Din Rail mount version PS1 005 24 PS1 010 24 PS1 018 24 PS1 100... PS1 120... PS1 480 24 PS1 480 48 PS3 0... PS1 030... PS1 060... PS1 240... PS1 300... Order code Rated Rated Output Qty Wt output output power per voltage current pkg [V] [A] [W] n [kg] Single phase. PS1 005 24 24VDC 0. 5 1 0.190 PS1 010 24 0.42 10 1 0.1 PS1 018 24 0.75 18 1 0.226 PS1 030 24 1.25 30 1 0.336 PS1 060 24 2.5 60 1 0.400 PS1 100 24 4.2 100 1 0.508 PS1 120 24 5 120 1 1.018 PS1 240 24 10 240 1 1.486 PS1 300 24 12.5 300 1 1.4 PS1 480 24 20 480 1 2.348 PS1 030 48 48VDC 0.625 30 1 0.336 PS1 060 48 1.25 60 1 0.400 PS1 100 48 2.1 100 1 0.508 PS1 120 48 2.5 120 1 1.018 PS1 240 48 5 240 1 1.486 PS1 300 48 6.25 300 1 1.4 PS1 480 48 10 480 1 2.348 Two phase. PS2 100 24 24VDC 4.2 100 1 0.570 PS2 100 48 48VDC 2.1 100 1 0.570 Three phase❶. PS3 120 24 24VDC 5 120 1 0.0 PS3 240 24 10 240❶ 1 1.190 PS3 480 24 20 480❶ 1 1.995 PS3 0 24 40 0❶ 1 3.672 PS3 240 48 48VDC 5 240❶ 1 1.190 PS3 480 48 10 480❶ 1 1.995 PS3 0 48 20 0❶ 1 3.672 ❶ Two-phase connection is admissible with a 25% output power derating. General characteristics This type of equipment is used to power supply electromechanical and electronic devices with DC control, such as contactors, time relays, sensors, PCs, DC motors, displays, SSRs and other equipment normally found in automation systems and networks. Protections: Short circuit Overload Input voltage peaks. Indications: ED indicator for low voltage conditions ED indicator for power on. Operational characteristics Rated supply voltage: (PS1 005...PS1 100) 115...230VAC self-configurable (PS1 120...PS1 480) 400...500VAC (PS2... and PS3...❶) Rated output voltage: 24VDC (PS...24) / 48VDC (PS...48) Mains frequency: 50/60Hz Output voltage adjustment by front potentiometer PFC function for types: PS1 120 24...PS3 0 24 PS1 120 48...PS3 0 48 Parallel connection for types: PS1 120 24, PS1 240 24, PS1 300 24, PS1 480 24, PS2 100 24, PS3 240 24, PS3 480 24, PS3 0 24, PS1 120 48, PS1 240 48, PS1 300 48, PS1 480 48, PS2 100 48, PS3 240 48, PS3 480 48, PS3 0 48 High efficiency up to 92% 35mm DI rail (IEC/E 60715) mounting Screw connection terminals Plastic or metal housing depending on type IEC degree of protection: IP20 on terminals. Certifications and compliance Certifications obtained: EAC; U isted for USA and Canada (cuus-file E318016) as Power Supplies in power circuit and motor-mounted apparatus category. Compliant with standards: IEC/E 60950-1, IEC/E 61000-6-2, IEC/E 61000-6-3, U508, CSA C22.2 n 107.1. Redundancy modules Order code Rated Rated Qty Wt output output per voltage current pkg [V] [A] n [kg] PSRM 10 24 12...24VDC 10 1 0.075 PSR 20 24 24VDC 20 1 0.0 General characteristics They are used for the redundancy connection of two or more power supplies to enhance the reliability of the DC supply. The redundancy modules ensure a perfect insulation between the power supplies connected. Indications (only for PSR 20 24): ED indicator for DC voltage within limit Alarm relay. PSR M1024 PSR 2024 Indications (PSR 20 24) Input Input ED ED Relay Relay voltage A voltage B A B A B Within limits Within limits O O Energ. Energ. Within limits <MI or >MAX O OFF Energ. De-energ. <MI or >MAX Within limits OFF O De-energ. Energ. <MI or >MAX <MI or >MAX OFF OFF De-energ. De-energ. Operational characteristics Rated input voltage: 12...24VDC (PSRM 10 24) 24VDC (PSR 20 24) Rated input current: 10A (PSRM 10 24) 20A (PSR 20 24) Maximum input current (for channel): 8A per 300s(PSRM 10 24) 16A per 300s (PSR 20 24) Rated output current : 10A (PSRM 10 24) 20A (PSR 20 24) Maximum output current: 16A per 300s (PSRM 10 24) 30A per 300s (PSR 20 24) Modular housing DI 43880 2 modules (PSRM 10 24) 35mm DI rail (IEC/E 60715) mounting (PSR 20 24) Screw connection terminals Plastic or metal housing depending on type IEC degree of protection: IP20 on terminals. Certifications and compliance Certifications obtained: cuus (only for PSR 20 24), EAC. Compliant with standards: IEC/E 60950-1, IEC/E 61000-4-2, IEC/E 61000-4-3, IEC/E 61000-4-4, IEC/E 61000-4-6, IEC/E 61000-4-8, U 508 (only for PSR 20 24). Dimensions page -4 Wiring diagrams page -5 Technical characteristics page -7-3

Dimensions [mm (in)] MODUAR SWITCHIG POWER SUPPIES PS1M 010... PS1M 024... PS1M 033 12 - PS1M 036 24 18 (0.71 ) 35 (1.38 ) 53 (2.09 ) PS1M 054 12 - PS1M 060 24 72 (2.83 ) PS1M 72 12 - PS1M 100 24 PSRM 10 24 90 (3.54 ) 35 (1.38 ) SWITCHIG POWER SUPPIES PS1 005 24 - PS1 100 24 PS2 100 24 A B C TYPE A B C PS1 005 24 22.5 (0.88 ) 90 (3.54 ) 115 (4.53 ) PS1 010 24 22.5 (0.88 ) 90 (3.54 ) 115 (4.53 ) PS1 018 24 22.5 (0.88 ) 90 (3.54 ) 115 (4.53 ) PS1 030... 40.5 (1.59 ) 90 (3.54 ) 115 (4.53 ) PS1 060... 40.5 (1.59 ) 90 (3.54 ) 115 (4.53 ) PS1 100... 54 (2.12 ) 90 (3.54 ) 115 (4.53 ) PS2 100... 54 (2.12 ) 90 (3.54 ) 115 (4.53 ) PSR 20 24 54 (2.12 ) 90 (3.54 ) 115 (4.53 ) PS1 120 24 - PS1 480 24 PS3... A B C TYPE A B C PS1 120... 64 (2.52 ) 124.5 (4.90 ) 123.6 (4.87 ) PS1 240... 83.5 (3.29 ) 124.5 (4.90 ) 123.6 (4.87 ) PS1 300... 83.5 (3.29 ) 124.5 (4.90 ) 123.6 (4.87 ) PS1 480... 175.5 (6. ) 124.5 (4.90 ) 123.6 (4.87 ) PS3 120 24 74.3 (2.92 ) 124 (4.88 ) 118.8 (4.68 ) PS3 240... 89 (3.50 ) 124 (4.88 ) 118.8 (4.68 ) PS3 480... 150 (5.90 ) 124 (4.88 ) 118.8 (4.68 ) PS3 0... 275.8 (10.86 ) 125.9 (4. ) 120.3 (4.74 ) -4

Wiring diagrams MODUAR SWITCHIG POWER SUPPIES PS1M 010 12 PS1M 010 24 PS1M 024 12 - PS1M 033 12 PS1M 054 12 - PS1M 072 12 PS1M 024 24 - PS1M 036 24 PS1M 060 24 - PS1M 100 24 + + 12VDC 24VDC 12VDC 24VDC SWITCHIG POWER SUPPIES PS1 005 24 PS1 010 24 PS1 018 24 PS1 030... PS1 060... PS1 100... - PS1 120... PS1 240... - PS1 300... PS1 480... 115/230VAC GD GD GD + RDY Open collector RDY RDY PS2 100... 400...500VAC PS3 120 24 - PS3 240...❶ PS3 480...❶ - PS3 900...❶ 400...500VAC GD 1 2 3 GD ❶ Two-phase connection is admissible with a 25% output power derating. RDY RDY RDY RDY REDUDACY MODUES PSRM 10 24 PSR 20 24 Vin A+ Vin B+ Vin Vout + Vout 12-24VDC A+ A+ B+ B+ + 12-24VDC Vin A+ Vin B+ Vin / Vout Vout + REAY A REAY B OK RDY A FAI OK RDY B FAI FAI OK FAI OK RDYA RDYB IPUT 24VDC RDY RDY -5

Technical characteristics MODUAR SWITCHIG POWER SUPPIES PS1M... TYPES TYPE Single phase PS1M 010 12 - PS1M 024 12 - PS1M 033 12 - PS1M 054 12 - PS1M 072 12 - PS1M 010 24 PS1M 024 24 PS1M 036 24 PS1M 060 24 PS1M 100 24 Two phase Three phase IPUT CHARACTERITICS Rated supply voltage Multivoltage Operating range 90...264VAC / 120...375VDC Consumption Frequency range 47...63Hz PFC Insulation voltage Input/output 3000VAC (4242VDC) Internal fuse (250VAC) ❶ T1A T2A T3A CHARACTERISTICS Voltage 12VDC (PS1M...12); 24VDC (PS1M...24) Voltage trimming (potentiometer) 12...14VDC (PS1M...12) 24...28VDC (PS1M...24) Current 0.83A (PS1M...12) 2A (PS1M...12) 2.75A (PS1M...12) 4.5A (PS1M...12) 6A (PS1M...12) 0.42A (PS1M...24) 1A (PS1M...24) 1.5A (PS1M...24) 2.5A (PS1M...24) 4.2A (PS1M...24) Temperature coefficient ±0.03%/ C ine adjustment ±1% oad adjustment ±1% Efficiency 78% (PS1M...12) 84% (PS1M...12) 83% (PS1M...12) 84% (PS1M...12) 86% (PS1M...12) 80% (PS1M...24) 85%(PS1M...24) 84% (PS1M...24) 86% (PS1M...24) 89% (PS1M...24) Overload protection 125...185% 120...160% 110...150% 110...150% 110...150% Short-circuit protection Hiccup Hiccup Fold forward Ripple noise 50mV Parallel connection (n of units)❸ IDICATIOS ED indicator for power on Yes ED indicator for low voltage Yes Power Rdy (Ready) (minimum limit) AMBIET CODITIOS Operating temperature ❹ Storage temperature Derating (>60 C) HOUSIG Material -40...+71 C -40...+85 C 2.5%/ C Plastic REDUDACY MODUES PSR... TYPE PSRM 10 24 PSR 20 24 IPUTS CHARACTERISTICS Rated input voltage 12-24VDC 24VDC Operating range 9 35VDC 28VDC umber of input 2 2 Rated input current 10A 20A Maximum input current (for channel) 8A for 300s 15A for 300s S CHARACTERISTICS Output voltage drop 0.5V 0.5V Rated output current 10A 20A Maximum reverse voltage 35V 30V Maximum output current 16A for 300s 30A for 300s IDICATIOS DC O indicator for input A - Yes DC O indicator for input B - Yes Power Rdy (Ready) - Ok if input >20V (±5%) or <30V(±5%) (minimum limit) Fail if input <20V (±5%) or >30V(±5%) 1A at 30VDC AMBIET CODITIOS Operating temperature -40 +71 C Storage temperature -40 +85 C HOUSIG Material Plastic Plastic -6

Technical characteristics SWITCHIG POWER SUPPIES PS... TYPES PS1 005 24 PS1 010 24 PS1 018 24 PS1 030 24 PS1 060 24 PS1 100 24 PS1 120 24 PS1 240 24 PS1 300 24 PS1 480 24 PS1 030 48 PS1 060 48 PS1 100 48 PS1 120 48 PS1 240 48 PS1 300 48 PS1 480 48 PS2 100 24 PS2 100 48 PS3 120 24 PS3 240 24 PS3 480 24 PS3 0 24 PS3 240 48 PS3 480 48 PS3 0 48 Multivoltage Self-configurable 115...230VAC Multivoltage 400...500VAC ❷ 90...264VAC / 85...264VAC / 90...264VAC 90...132VAC / 180...264VAC 90...264VAC 340...575VAC 120...375VDC 90...375VDC 120...375VDC 0...375VDC 120...375VDC 480...820VDC 200mA 300mA 500mA 800mA 1.5A 2.4A 2.8A 5.4A/2.2A 6A 6A/3A 750mA 500mA 850mA 1.4A 2.4A 47...63Hz 0.7 0.97 0.55 0.65 0.8 3000VAC (4242VDC) T2A T3.15A T6.3A T8A T10A T2A T3.15A/500VAC T5A/500VAC 24VDC (PS...24); 48VDC (PS...48).6...28.8VDC 24...28VDC 22.5...28.5VDC 22.5...28.5 22.5...28.5VDC 48...55VDC 47...56VDC VDC 47...56VDC 0.A 0.42A 0.75A 1.25A 2.5A 4.2A 5A 10A 12.5A 20A 4.2A 5A 10A 20A 40A 0.625A 1.25A 2.1A 2.5A 5A 6.25A 10A 5A 10A 20A 0.03%/ C 0.03%/ C ±1% 0.5% ±1% ±0.5% ±1% ±2% 0.5% ±1% 72% 76% 77% 86% 89% 88% 86% 89% 89% 87% 89% 90% 90% 92% 110...135% 110...1% 110...140% 110...150% 110...150% 110...140% 110...1% 120...1% 110...140% 115...135% 120...140% 110...135% 125...1% Hiccup Fold forward Hiccup Fold forward Hiccup 50mV 50mV 100mV 50mV 100mV 80mV 3 2 2 2 2 Yes Yes Yes Yes (transistor output) Yes (relay output) Yes (trans. Yes (relay output) (18.8VDC) (17.6VDC) output) (17.6VDC) (60VDC) -20...+71 C -40...+71 C -35...+71 C -40...+71 C -30...+71 C -40...+71 C -30...+71 C -40...+71 C -25...+85 C -40...+85 C 2.5%/ C 3.5%/ C Plastic Metal Plastic Metal ❶ o replacement by user. ❷ Two-phase connection is possible with 25% power derating, except types PS2 100 24 and PS3 120 24. ❸ Minimum load of 150mA. ❹ Maximum surrounding temperature of 50 C for use according to U508. -7