erie street hotel 12-22 WEST ERIE STREET CHICAGO, IL PROJECT DATA SITE AREA BUILDING AREA (FAR) LEVELS HEIGHT GUESTROOM COUNT PROJECT F.A.R. BASE F.A.R. PROPOSED F.A.R. 13,819 SF 111,933 SF 14 LEVELS+ PENTHOUSE 163 178 5.0 8.1 SITE AREA TOTAL BUILDING AREA MAX. PERMITTED BUILDING AREA LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 LEVEL 6 LEVEL 7 LEVEL 8 LEVEL 9 LEVEL 10 LEVEL 11 LEVEL 12 LEVEL 13 LEVEL 14 TOTAL AREA 13,819 SF 111,933 SF 111,933 SF 9,337 SF 6,228 SF 8,468 SF 8,468 SF 8,468 SF 8,468 SF 8,468 SF 8,468 SF 8,468 SF 8,468 SF 8,468 SF 8,468 SF 5,822 SF 5,856 SF 111,933 SF
STACKING DIAGRAM DX-5 MASSING 11 FLOORS / 149 TALL ROOFTOP MECHANICAL HOTEL AMENITY LEVEL 11 GUESTROOMS LEVELS 2-10 KEYS: 90 HOTEL ENTRY RESTAURANT LEVEL 1
SITE PLAN - EXISTING 33 W. HURON ST. BILLBOARD PUBLIC ALLEY PUBLIC ALLEY PROPERTY LINE - TYPICAL EXISTING FENCE RECEIVING OUTLINE OF PROPOSED ERIE STREET HOTEL ELECTRICAL TRANSFORMERS / COMED EASEMENT 26 W. ERIE EXISTING 3-STORY BRICK WITH BASEMENT 102' - 0 5/8" EXISTING 4-STORY BRICK WITH BASEMENT EXISTING 3-STORY BRICK WITH BASEMENT EXISTING SURFACE PARKING DANA HOTEL AND SPA N. STATE STREET EXISTING TERRACE 22 W. ERIE 16 W. ERIE 14 W. ERIE EXISTING PARKWAY PLANTING ONE WAY TRAFFIC EXISTING CONCRETE DRIVE AND CURBCUT W. ERIE STREET 0 32 64
erie street hotel 12-22 WEST ERIE STREET CHICAGO, IL AERIAL VIEW LOOKING NORTHEAST
DEVELOPMENT HISTORY MARCH 2014-255 TALL / 26 FLOORS / 222 KEYS MARCH 2017-163 TALL / 14 FLOORS / 178 KEYS
FLOOR PLAN UP CR T UP T T T W W W LEVEL 1 DN UP LOADING DOCK HOTEL SERVICE AREA DN UP ELEC. WATER/ PUMP CARB BAG-IN-BOX SODA RACK CO2 CO2 W W T T T T T T UP RESTAURANT & HOTEL BAR HOTEL LOBBY CONNECTION CORRIDOR ON TWO FLOORS LUGGAGE CHEF ELEV. MACHINE. RESTAURANT ENTRANCE 6' - 3" 6' - 4" 5' - 10" ERIE STREET HOTEL ENTRANCE 25' - 0" 23' - 0" 25' - 0" 21' - 11 7/8" 52' - 5" 25' - 0" 1' - 0" 5' - 10" 12' - 7" 0 8 16
FLOOR PLAN TYPICAL GUESTROOM FLOOR ROOM MIX KING: DOUBLE QUEEN: KING SUITE: TOTAL: 127 40 11 178 UP DN 0 8 16
FLOOR PLAN LEVEL 13- AMENITY FLOOR HOTEL AMENITY POOL HOTEL AMENITY POOL DECK 0 8 16
FLOOR PLAN LEVEL 14- CONFERENCE FLOOR EVENT SPACE DN UP DN DN DN EVENT SPACE POOL BELOW POOL DECK BELOW 0 8 16
erie street hotel SOUTH FACADE
STACKING DIAGRAM DX-8.1 MASSING 14 FLOORS / 163 TALL ROOFTOP MECHANICAL HOTEL AMENITY / EVENT SPACE LEVELS 13-14 GUESTROOMS LEVELS 2-12 KEYS: 178 HOTEL ENTRY RESTAURANT LEVEL 1
BUILDING ELEVATIONS TEXTURED CAST-IN- PLACE CONCRETE ARTICULATED CAST-IN- PLACE CONCRETE ANGLED CORRUGATED ALUM. WALL PANELS W CONC. BASE ARTICULATED CAST- IN-PLACE CONCRETE COLOR COATED ALUM. WINDOW WALL WITH LOW-E GLAZING PAINTED MASONRY ALUM. CLAD CANOPY 12' - 8" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 14' - 0" 14' - 0" 18' - 0" 12' - 0" PENTHOUSE ROOF 160' - 8" LEVEL 15 148' - 8" COLOR COATED ALUM. SLAB EDGE COVER, TYP. LEVEL 14 130' - 8" LEVEL 13 116' - 8" CLEAR GLASS BALCONY RAILING, TYP. LEVEL 12 102' - 8" LEVEL 11 93' - 8" LEVEL 10 84' - 8" LEVEL 9 75' - 8" LEVEL 8 66' - 8" LEVEL 7 57' - 8" LEVEL 6 48' - 8" LEVEL 5 39' - 8" LEVEL 4 30' - 8" LEVEL 3 21' - 8" LEVEL 2 12' - 8" LEVEL 1 0" ARTICULATED CAST -IN-PLACE CONCRETE GREEN WALL SYSTEM CLEAR GLASS BALCONY RAILING COLOR COATED ALUMINUM WINDOW WALL WITH LOW-E GLAZING COLOR COATED ALUMINUM MULLION EXTENSION ALUMINUM CLAD STEEL TRELLIS EXISTING BUILDING COLOR COATED ALUM. SLAB EDGE COVER, TYP. ALUM. CLAD CANOPY WOOD CLAD PLANTERS ILLUMINATED EXTERIOR CEILING PANELS COLOR COATED ALUM. WINDOW WALL WITH LOW-E GLAZING ALUMINUM GUARDRAIL 8' HIGH COLOR COATED ALUMINUM GUARDRAIL WITH LOW-E GLAZING POINT SUPPORTED GLASS CANOPY ON STEEL STRUCTURE PENTHOUSE ROOF 160' - 8" LEVEL 15 148' - 8" LEVEL 14 130' - 8" LEVEL 13 116' - 8" LEVEL 12 102' - 8" LEVEL 11 93' - 8" LEVEL 10 84' - 8" LEVEL 9 75' - 8" LEVEL 8 66' - 8" LEVEL 7 57' - 8" LEVEL 6 48' - 8" LEVEL 5 39' - 8" LEVEL 4 30' - 8" LEVEL 3 21' - 8" LEVEL 2 12' - 8" LEVEL 1 0" 12' - 8" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 14' - 0" 14' - 0" 18' - 0" 12' - 0" 163' - 8" ARTICULATED CAST-IN- PLACE CONCRETE CLEAR GLASS BALCONY RAILING 8' HIGH COLOR COATED ALUMINUM GUARDRAIL WITH LOW-E GLAZING ALUMINUM GUARDRAIL COLOR COATED ALUMINUM WINDOW WALL WITH LOW-E GLAZING COLOR COATED ALUM. SLAB EDGE COVERS, TYP. OUTLINE OF ADJACENT EXISTING BUILDING DANA HOTEL CANOPY BEYOND POINT SUPPORTED GLASS CANOPY ON STEEL STRUCTURE OUTLINE OF BASEMENT NORTH ELEVATION OUTLINE OF BASEMENT SOUTH ELEVATION WEST ELEVATION
erie street hotel VIEW FROM STATE AND ERIE
erie street hotel SIDEWALK CAFE
erie street hotel HOTEL ENTRANCE AND CANOPY
erie street hotel 12-22 WEST ERIE STREET CHICAGO, IL AERIAL VIEW LOOKING NORTHEAST
erie street hotel 12-22 WEST ERIE STREET CHICAGO, IL AERIAL VIEW LOOKING SOUTHEAST
erie street hotel Dedicated to serving our community since 2008. WWW.THEFIFTY50GROUP.COM
SITE PLAN - PROPOSED EXISTING FENCE BILLBOARD LOT AREA: 13,819 SF PUBLIC ALLEY PROPERTY LINE - TYPICAL CANOPY ABOVE 26 W. ERIE TRASH ENCLOSURE SHARED LOADING AREA ELECTRICAL TRANSFORMERS / COMED EASEMENT CANOPY ABOVE LOADING BERTH (10'X50) DASHED LINE DEPICTS OUTLINE OF TOWER ABOVE 102' - 0 5/8" ERIE STREET HOTEL DANA HOTEL AND SPA EXISTING VALET PUBLIC ALLEY RESTAURANT ENTRY RESTAURANT SEATING PUBLIC WAY SEATING (APPROXIMATELY 375 SF) 10' - 0" ERIE STREET HOTEL ENTRY NEW IN-GROUND PLANTING BED AND SHRUBS EXISTING TREES AND PLANTERS TO REMAIN STATE STREET CANOPY ABOVE P P P P P P NEW IN-SIDEWALK PLANTER WITH NEW TREES AND SHRUBS PLANTINGS PER CITY LANDSCAPE ORDINANCE STREET PARKING ERIE STREET VALET / DROP-OFF ONE WAY TRAFFIC EXISTING VALET P P P P P P P 0 32 64 EXISTING CURB CUT / SERVICE ACCESS FIRE HYDRANT
VALET CIRCULATION
erie street hotel 12-22 WEST ERIE STREET CHICAGO, IL AERIAL VIEW LOOKING NORTHEAST