W H Y C O N D U C T A F A C I L I T Y C O N D I T I O N A S S E S S M E N T

Similar documents
PROPERTY CONDITION ASSESSMENT

[BUILDING STATISTICS PART I]

GUIDANCE DOCUMENT PROPERTY CONDITION ASSESSMENT (PCA) BASE DOCUMENT*

Procedures on Maintenance Services and. Required Inspections for the ADR Tenants. Seattle Tacoma International Airport.

Facility Assessment. Municipal Facilities 1245 and 1885 North Hacienda Road La Habra Heights, California 90631

TENANT DESIGN MANUAL UPDATED JUNE 2015

MARCH GUIDE TO BUILDING CONDITION ASSESSMENTS and RESERVE FUND STUDIES

Autumn Ridge 3888 Autumn Ridge Court Memphis, Tennessee 38115

Preventive Maintenance Program

AIRPORT DINING & RETAIL PREVENTIVE MAINTENANCE PROGRAM MANUAL

TENANT DESIGN MANUAL UPDATED JULY 2016

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT

Financial Statement Instructions 324

FANNIE MAE MULTIFAMILY INSTRUCTIONS FOR PERFORMING A MULTIFAMILY PROPERTY CONDITION ASSESSMENT. May, 2017 TABLE OF CONTENTS

Revised Reroof Checklist

ACCESSORY DWELLING UNITS

CUMBERLAND SCHOOLS WORK PROPOSED 2018

COUNCIL OF CO-OWNERS OF THE WESTERLIES CONDOMINIUM POLICY RESOLUTION NO (Policy Concerning Maintenance Responsibilities)

TENANT DESIGN MANUAL UPDATED JANUARY 2016

FANNIE MAE MULTIFAMILY INSTRUCTIONS FOR THE PNA PROPERTY EVALUATOR TABLE OF CONTENTS

Chapter 24 Saskatchewan Housing Corporation Housing Maintenance 1.0 MAIN POINTS

Emil G Hirsch Metropolitan High School 7740 S Ingleside Ave Chicago, IL 60619

2015 Portable Condition Visual & Documented Inspection Report

TENANT DESIGN MANUAL UPDATED JUNE 2015

TENANT DESIGN MANUAL UPDATED MAY 2016

CAPITAL NEEDS ASSESSMENT DRAFT. Tyrone Township Hall Center Road Fenton, Michigan Natura Project No

ACCESSORY DWELLING UNITS

4-Point Inspection Personal Lines (Edition 9/2012 revised)

Building Specifications

HSC Regeneration Forum The Last Chapter First: Lessons Learned

1. Project No.: 812 Muslim Commercial Bank, Karachi Mechanical & Electrical System

518 3 rd Avenue South St. Petersburg, Florida

PROPERTY CONDITION ASSESSMENT REAL ESTATE ADVISORY, LLC PROJECT

DESCRIPTION OF LANDLORD'S WORK & TENANT'S WORK

TENANT DESIGN MANUAL UPDATED JUNE 2015

Shoreview Corporate Center

MADISON AVENUE FEATURES LEASING INFORMATION. 18-foot ceiling heights (slab-to-slab) New building construction

WISCONSIN REAL ESTATE CONDITION REPORT 1

MECHANICAL ENGINEERS INC, College-University. University of Colorado at Boulder Boulder, CO. Darley South Bathroom Renovation

RIDGEDALE A VENUE E AST H ANOVER, NEW J ERSEY

Astm E Need to access completely for Ebook PDF astm e

TENANT DESIGN MANUAL UPDATED AUGUST 2015

Slabs and Flooring. Slab On Grade Flooring. Capillary Rise. ! Problems due to. Flooring

Inspection Proposal 3/7/2013. Client: Phone:

TENANT DESIGN MANUAL UPDATED JULY 2015

PROPERTY CONDITION REPORT- PCR. Address: 123 Business Street City: Arlington State: TX Zip: 76011

Appendix E: C-PACE FINANCING FOR SOLAR PV SYSTEMS AND FUEL CELLS

TENANT DESIGN MANUAL UPDATED OCTOBER 2016

RETROFIT OF BUILDINGS BY DUBLIN CITY COUNCIL. Matt Carroll, City Architects Division DUBLIN CITY COUNCIL

GENERAL INFORMATION. Landlord s Tenant Coordinator

Knowledge based Condition Assessments

SELLER S PROPERTY DISCLOSURE STATEMENT

REV General Proposed Additions and Alterations Compliance with Codes 1-1

Worldwide ERC Statement of Use: Relocation Property Assessment

STATE UNIVERSITY of NEW YORK PROJECT CAPITALIZATION FORM (PCF) INSTRUCTIONS

TENANT DESIGN MANUAL UPDATED DECEMBER 2018

Residential Energy Credits

John F Kennedy High School 6325 W 56th St Chicago, IL Co-locating on this campus are KENNEDY HS and KINZIE

MMRP FRUIT & VEGETABLE TRADING STORES TENANCY FIT-OUT DO S & DON TS Rev 4 27/03/15

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JUNE 2015

LITTLE MOUNTAIN ADJACENT AREA REZONING POLICY

AGENDA REPORT. Meeting Date: January 9, 2018 Item Number: D 10 To: From:

CITY OF CLIVE, IOWA Sidewalk Inspection and Repair Policy

SCOPE All fees associated with and referenced in the 2016 Building Code of the City and County of Denver ( Code ) are as set forth in this policy.

MECHANICAL HVAC PERMIT CHECKLIST

REQUEST FOR PROPOSAL (RFP)

PACE Financing Application Los Angeles County Commercial Property Assessed Clean Energy (PACE) Program

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015

Charles Kozminski Elementary Community Academy

Town of Clinton, Connecticut Action Plan for the Historic Unilever Property and Area. Steering Committee Meeting #5 Implementation Strategies

Bedford County Board of Education

CAPITAL IMPROVEMENT PLAN

The Final Tangible Property Repair Regulations and Fixed Asset Review: Opportunities for 2016 and Beyond

THE NEW RULES EXPENSE OR CAPITALIZE?

TENANT DESIGN MANUAL UPDATED OCTOBER 2016

TENANT DESIGN MANUAL UPDATED JUNE 2015

RESIDENTIAL PROPERTY DISCLOSURE FORM

Rental Assistance Demonstration (RAD): Physical Condition Assessment Statement of Work and Contractor Qualifications

Phoenix Military Academy High School 145 S Campbell Ave Chicago, IL Co-locating on this campus are MARINE MILITARY HS and PHOENIX MILITARY HS

The relationships between the extent of mould problems and physical building characteristics in high-rise apartment buildings

CHARLESTON PLACE TENANT CALCULATION CHECK/DATA TABULATION SHEET(S) Forms must be completed by the Tenant's Mechanical or Electrical Engineer.

OREGON SELLER S PROPERTY DISCLOSURE STATEMENT

SUNSET BAY VILLAS. CONDO ASSOCIATION NEWSLETTER: December 2017

TENANT DESIGN MANUAL UPDATED FEBRUARY 2017

TITLE 318 DEPARTMENT OF ENVIRONMENTAL MANAGEMENT

TENANT DESIGN MANUAL UPDATED JULY 2015

This fee structure applies to applications submitted on or after January 1, 2018.

Salmon P Chase Elementary School 2021 N Point St Chicago, IL 60647

Building Condition Survey #R14-BCS0514

350 MADISON AVENUE IS A PREMIER CLASS-A OFFICE BUILDING LOCATED ONE BLOCK FROM GRAND CENTRAL TERMINAL IN THE HEART OF MIDTOWN. RFR HAS CREATED AN

TENANT DESIGN MANUAL UPDATED JULY 2015

THE CITY OF WINNIPEG BY-LAW NO. 96/2012

Alex Haley Elementary Academy S Eggleston Ave Chicago, IL 60628

Reynoldsburg Code of Ordinances. CHAPTER 1305 Permits and Fees

CHAPTER 1321 Permit and Inspection Fees

CONSTRUCTION CRITERIA

Bangor Mall Bangor, ME

Transcription:

W H Y C O N D U C T A F A C I L I T Y C O N D I T I O N A S S E S S M E N T January 22, 2015

What is a Facility Condition Assessment

ASTM Standard 2018 FCA Facility Condition Assessment PCA Property Condition Asssessment PNA Physical Needs Assessment BER Building Evaluation Report. Purpose The purpose of this guide is to define good commercial and customary practice in the United States of America for conducting a baseline property condition assessment (PCA) of the improvements located on a parcel of commercial real estate by performing a walk-through survey and conducting research as outlined within this guide. 3

ASTM Standard 2018 Standard Guide for Property Condition Assessments: Baseline Property Condition Assessment Process. Purpose The purpose of this guide is to define good commercial and customary practice in the United States of America for conducting a baseline property condition assessment (PCA) of the improvements located on a parcel of commercial real estate by performing a walk-through survey and conducting research as outlined within this guide. 4

Other Applicable Standards ASHRAE 90.1 Energy 62.1 Building Indoor Air (ventilation stds) NFPA - ADA - BOMA - 5

Why Conduct an FCA Avg Building Age in US is 41 years USDOE Avg School Age over 40 (NCES)

Why Conduct an FCA Planning Code Compliance Forecasting Preventive Maintenance vs Reactive

Who Benefits Facility Managers Maintenance Personnel Administrative Staff Contractors Executing Projects 8

Desired Outcomes Insight into Immediate needs Vis into systems life cycle replacement Consolidated Capital Plan Maintenance Capital Projects Life Cycle Replacement A developed sustainable Funding Model 9

Capital Forecast vs Maint Management Maintenance Edge Component Level Work Order Tracking and Generation Preventive maintenance routine Complete Systems inventory Capital Forecast Complete systems inventory Condition and priority ratings Life Cycle Replacement cost and timing 10

Building Systems Non-Building Campus Infrastructure Wall Evaluation Roofing (Non-Invasive Visual) Plumbing HVAC Electrical Elevators + Vertical Transportation Life Safety/Fire Protection Interior Elements Accessibility Compliance Code Compliance Mold 11

Typical Detail on Roofing Common roof compositions: Shingled: Small units of material which are laid in a series of overlapping rows as a roof covering on pitched roofs. Built-up: constructed on the roof using layers of component materials such as felts and asphalt. Membrane: flexible sheets of compounded synthetic materials, manufactured offsite and secured to a roof deck over insulation. 12

Typical Detail on Roofing Assessment identifies: Material roof systems (exposed membrane and flashings) Slope and drainage Oriented Strand Board (OSB) damage ponding or leaks Seam/lap failure Ridging, blistering Deterioration, alligatoring 13

Typical Detail on HVAC Confirm information given by maintenance contractor Determine what areas are served by what equipment, identify Owner vs. tenant responsibility Determine estimated and remaining useful life (EUL, RUL) Split systems, Rooftop units, Heat Pumps Boilers Cooling Tower, Chiller, Condenser Units Fan Coil and Air Handling Units Packaged Terminal Air Conditioners (PTAC) 14

Building Envelop Inspect for Cracking Bulging/Vertical displacement Evidence of moisture infiltration Sealant joints around openings and penetrations (e.g. window caulking) 15

Lifecycle 16

Lifecycle 17

Condition & Priority 18

Cost Estimating 19

Outcomes 20

Building Equipment/ System Detail 21

Immediate Repairs Report 22

Condition, Life-Cycle, Replacement Cost 23

Prioritized Capital Plan 27

Facility Condition Index FCI $ (cost of Immediate Repairs + Deferred Maintenance) $ (current replacement value) 30

Preparing an RFP APPA CEFPI ASTM 32

Optional Items Inventory Barcoding CAD drawings Specialty studies Elevator Fire and Life-safety 33

Thank You Matthew Munter, P.E. Sr. Vice President msmunter@emgcorp.com 800.733.0660, ext. 2709 34

A B O V E A N D B E Y O N D. E V E R Y C L I E N T. E V E R Y P R O J E C T. E V E R Y T I M E.