PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: March 15, 2007

Similar documents
PLANNED UNIT DEVELOPMENT, SIDEWALK WAIVER, & SUBDIVISION STAFF REPORT Date: November 6, 2008

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: November 17, 2016

SUBDIVISION, PLANNED UNIT DEVELOPMENT, & PLANNING APPROVAL STAFF REPORT Date: February 1, 2007

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT August 18, 2016

MOBILE TOWERS SUBDIVISION

HERON LANDING SUBDIVISION

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: July 20, 2017

ZONING AMENDMENT, PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: August 8, 2013

SUBDIVISION, PLANNED UNIT DEVELOPMENT, PLANNING APPROVAL, ZONING AMENDMENT, & SIDEWALK WAIVER REQUEST STAFF REPORT Date: February 17, 2010

ZONING AMENDMENT, PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: March 5, 2009

APPLICANT NAME SUBDIVISION NAME DEVELOPMENT NAME LOCATION. CITY COUNCIL DISTRICT Council District 4 PRESENT ZONING PROPOSED ZONING

BETTA STOR-IT SUBDIVISION

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: September 15, 2016

ZONING AMENDMENT, PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: September 15, 2011

ZONING AMENDMENT, & SUBDIVISION STAFF REPORT Date: May 17, 2007

SUBDIVISION & PLANNING APPROVAL STAFF REPORT Date: December 1, 2016

SUBDIVISION, PLANNED UNIT DEVELOPMENT, ZONING AMENDMENT, & SIDEWALK WAIVER STAFF REPORT Date: July 19, 2018

ZONING AMENDMENT & SUBDIVISION STAFF REPORT Date: July 9, 2015

ZONING AMENDMENT & SUBDIVISION STAFF REPORT Date: July 3, 2014

KLUGE PLACE SUBDIVISION

McGowin Park, LLC. B-3, Community Business District

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: May 6, 2004

ZONING AMENDMENT & PLANNED UNIT DEVELOPMENT STAFF REPORT Date: June 7, 2012

ZONING AMENDMENT & PLANNED UNIT DEVELOPMENT STAFF REPORT Date: July 5, 2012

MCGOWIN PARK EAST OF SATCHEL PAIGE SUBDIVISION, RESUBDIVISION OF

PLANNED UNIT DEVELOPMENT & ZONING AMENDMENT STAFF REPORT Date: December 21, 2017

DEER RIVER COMMERCIAL PARK SUBDIVISION

ALBA BEACH SUBDIVISION, RESUBDIVISION OF LOT 17

PLANNED UNIT DEVELOPMENT (East), PLANNED UNIT DEVELOPMENT (West) STAFF REPORT Date: September 18, 2014

COCHRAN FAMILY RIVERSIDE ESTATE SUBDIVISION

SOUTHERN INDUSTRIAL PARK SUBDIVISION, LOT A, RESUBDIVISION OF LOTS 7 & 8

ZONING AMENDMENT & SUBDIVISION STAFF REPORT Date: November 3, 2016

DAUPHIN CREEK ESTATES SUBDIVISION

ZONING AMENDMENT & SUBDIVISION STAFF REPORT Date: June 18, 2015

AUTUMNDALE SUBDIVISION, RESUBDIVISION OF LOTS

SUBDIVISION, PLANNING APPROVAL, & REZONING STAFF REPORT Date: June 4, 2015

ZONING AMENDMENT & SUBDIVISION STAFF REPORT Date: March 1, 2018

ZONING AMENDMENT, SUBDIVISION & SIDEWALK WAIVER REQUEST STAFF REPORT Date: November 16, 2006

NOBLE DRIVE EAST SUBDIVISION

ZONING AMENDMENT & SUBDIVISION STAFF REPORT Date: March 7, 2013

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: April 18, 2019

PLANNED UNIT DEVELOPMENT STAFF REPORT Date: October 19, 2017

KRONER S MOBILE WEST COMMERCIAL BUSINESS PARK SUBDIVISION

SUBDIVISION, PLANNED UNIT DEVELOPMENT, & REZONING STAFF REPORT Date: March 23, 2017

ZONING AMENDMENT, & SUBDIVISION STAFF REPORT Date: July 24, 2008

PLANNED UNIT DEVELOPMENT STAFF REPORT Date: August 20, 2015

DAWES SWITCHING STATION SUBDIVISION

THE CITY OF MOBILE, ALABAMA MOBILE Crry PLANNING COMMISSION

JOHNNY S RV PARK SUBDIVISION

MOBILE CITY PLANNING COMMISSION LETTER OF DECISION. June 3, 2011

AMELIA LAKE SUBDIVISON, PHASES 1-2

TERRY POIROUX FAMILY DIVISION SUBDIVISION

TULSA PARK ESTATES SUBDIVISION, RESUBDIVISION OF LOT 6

THE CI FY OF MOBILE, ALABAMA

MAGNOLIA SPRINGS SUBDIVISION, PHASE ONE

MTC ALABAMA SUBDIVISION

THE WHEELER BUILDING SUBDIVISION

DINKINS ESTATE FAMILY SUBDIVISION

PORT CITY COMMERCE PARK SUBDIVISION

BAY FOREST PARK SUBDIVISION, RESUBDIVISION OF LOTS 6 & 7 AND BAY FOREST PARK SUBDIVISION LOT 10, OF THE RESUBDIVISON OF LOTS 9 & 10

WESTMINSTER PARK SUBDIVISION

HAWTHORNE PLACE SUBDIVISON, RESUBDIVISION OF LOT 15 REVISED

ZONING AMENDMENT, PLANNED UNIT DEVELOPMENT & PLANNING APPROVAL STAFF REPORT Date: June 7, 2007

BROADWAY THREE NOTCH ROAD SUBDIVISION

# 1 HOLDOVER Revised SUB CANAL SUBDIVISION

THE CITY OF MOBILE, ALABAMA

THE BLUFFS AT CYPRESS CREEK SUBDIVISION, PHASE ONE

SUBDIVISION, PLANNED UNIT DEVELOPMENT, & REZONING STAFF REPORT Date: September 17, 2015

# 14 SUB CANAL SUBDIVISION

PENNY LAKES SUBDIVISION

THE CITY OF MOBILE, ALABAMA

WESTMINSTER PARK PLACE SUBDIVISION

STONE HEDGE SUBDIVISION, UNIT 1, RESUBDIVISION OF LOT 40 & WEST COMMON AREA

THE CITY OF MOBILE, ALABAMA

ZONING AMENDMENT STAFF REPORT Date: September 15, 2016

AMENDMENT TO REGULATING PLAN & SUBDIVISION STAFF REPORT Date: December 15, 2016

PALMER WOODS SUBDIVISION, PHASE III

# 6 Case #SUB LEGACY SUBDIVISION. Engineering Comments: Must comply with the Mobile County Flood Damage Prevention Ordinance.

TURTLE CREEK SUBDIVISION, PHASE THREE

THE CITY OF MOBILE, ALABAMA

Chapter 21 MOBILE HOME PARK REGULATIONS.

ARTICLE Encourage well planned, efficient development.

ELIZA JORDAN CORNER SUBDIVISION

PROVISION POINTE SUBDIVISION

Chapter Plat Design (LMC)

PLANNING AND ZONING COMMISSION AGENDA MEMORANDUM

THE BLUFFS AT CYPRESS CREEK SUBDIVISION

ARTICLE 14 PLANNED UNIT DEVELOPMENT (PUD) DISTRICT

5.0 Specific Use Regulations

SITE PLAN REVIEW PROCEDURES SECTION DEVELOPMENTS REQUIRING SITE PLAN APPROVAL

CHAPTER XVIII SITE PLAN REVIEW

ARTICLE 3 DEFINITIONS

SILVER PINES SUBDIVISION

Cover Letter with Narrative Statement

OAK HILL SUBDIVISION

Appendix J - Planned Unit Development (PUD)

DEVELOPMENT DEPARTMENT STAFF REPORT THE PARK AT 5 TH

ORDINANCE NO. Be it ordained by the City Council of the City of Abilene, Texas:

THE REDEVELOPMENT PLAN

Box Elder County Land Use Management & Development Code Article 3: Zoning Districts

Transcription:

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: March 15, 2007 DEVELOPMENT NAME SUBDIVISION NAME LOCATION Motormax Subdivision Motormax Subdivision 2917 and 2929 Government Boulevard (South side of Government Boulevard, 300 + East of Macmae Drive) CITY COUNCIL DISTRICT District 4 PRESENT ZONING AREA OF PROPERTY B-3, Community Business District 2 Lots / 2.1 + acres CONTEMPLATED USE Planned Unit Development approval to allow multiple buildings on a single commercial building site, and Subdivision approval to create two (2) lots. TIME SCHEDULE FOR DEVELOPMENT No timeframe provided. ENGINEERING COMMENTS Show limits of the flood zone. Show minimum finished floor elevation for any buildings or structures and/or slabs, on which, mechanical and electrical equipment will be installed. Must comply with all storm water and flood control ordinances. Any work performed in the right of way will require a right of way permit. TRAFFIC ENGINEERING COMMENTS Driveway number, size, location, and design to be approved by Traffic Engineering and ALDOT and conform to AASHTO standards. Standard driveway width for two-way traffic is twenty-four feet and thirty-six feet for three lanes. Changes should be made to accommodate the standard. URBAN FORESTRY COMMENTS Property to be developed in compliance with state and local laws that pertain to tree preservation and protection on both city and private properties (State Act 61-929 and City Code Chapters 57 and 64). FIRE DEPARTMENT COMMENTS No comments. - 1 -

REMARKS The applicant is requesting Planned Unit Development approval to allow multiple buildings on a single commercial building site, and Subdivision approval to create two (2) lots. The site consists of two parcels that the applicant proposes to convert into legal lots. The proposed Lot 2 contains an auto dealership, while proposed Lot 1 is the former Putt-Putt Golf facility, which is now vacant. The applicant proposes to renovate the existing structure on Lot 1, remove the golf course, and create another auto dealership with a new out building and canopy for auto detailing. Planned Unit Development review examines the site with regard to its location to ensure that it is generally compatible with neighboring uses; that adequate access is provided without generating excess traffic along minor residential streets in residential districts outside the PUD; and that natural features of the site are taken into consideration. PUD review also examines the design of the development to provide for adequate circulation within the development; to ensure adequate access for emergency vehicles; and to consider and provide for protection from adverse effects of adjacent properties as well as provide protection of adjacent properties from adverse effects from the PUD. PUD approval is site plan specific, thus any changes to the site plan must be approved by the Planning Commission. Subdivision review examines the site with regard to promoting orderly development, protecting general health, safety and welfare, and ensuring that development is correlated with adjacent developments and public utilities and services, and to ensure that the subdivision meets the minimum standards set forth in the Subdivision Regulations for lot size, road frontage, lot configuration, etc. The site fronts onto the service road for Government Boulevard, a US highway facility under the purview of the Alabama Department of Transportation. Because of the status of the facility, access management is a concern. Each lot should be limited to one curb-cut each onto the service road, with the size, design and location to be approved by ALDOT and Traffic Engineering, and conform to AASHTO standards. The Subdivision plat should be revised to include the size of each lot in square feet as either a note on each lot, or as a table. Regarding the PUD, it appears that the proposed improvements to the site will generally meet the minimum standards of the Zoning Ordinance. There are, however, a few items of concern. First, it appears that the directional arrows for on-site circulation will cause problems due to conflicting directional information: the site plan should be reviewed and revised to ensure that the arrow directions are correct for optimal circulation. Secondly, it appears that the eight (8) isolated parking spaces between the existing building and the proposed detail building may put autos parked at the each end of the row at risk for side-swiping. It is recommended that the designer consider removing the end parking spaces and replacing them with parking islands or painted islands to provide more maneuvering area. Regarding the proposed detailing building and shed, the run-off from the detailing operation must be directed to the sanitary sewer, and an oil separator must be provided. - 2 -

The site is adjacent to residential uses. A 6-foot high privacy fence is depicted, and it appears that all proposed improvements on the site are kept a minimum of 10 feet from the rear property line. In order to further minimize the impact of the site on adjacent residential uses, any onpremise lighting must comply with Sections 64-4.A.2. and 64-6.A.3.c. of the Zoning Ordinance; specifically lighting must not shine directly into adjacent residential properties or into traffic, and parking areas must be illuminated during their operation at night, if applicable. Finally, the site partially contains a drainage facility that is part of Bolton s Branch of Dog River. It appears that a portion of the site may be within the floodplain for the drainage facility. The potential presence of floodplains indicates that the site may be environmentally sensitive, therefore, the approval of all applicable federal, state and local agencies will be required prior to the issuance of any permits or land disturbance activities. RECOMMENDATION Planned Unit Development: Based upon the preceding, this application is recommended for Approval subject to the following conditions: 1) revision of the site plan to correct any directional arrow conflicts; 2) direction of any car washing or auto detailing run-off to an oil separator prior to discharge into the sanitary sewer system; 3) provision of the depicted 6-foot privacy fence along the property line abutting residential uses, and maintenance of a 10-foot protection buffer strip from the rear property line for all structures and parking areas, as depicted on the site plan; 4) compliance with the lighting requirements of Sections 64-4.A.2. and 64-6.A.3.c. of the Zoning Ordinance; 5) full compliance with Engineering comments (Show limits of the flood zone. Show minimum finished floor elevation for any buildings or structures and/or slabs, on which, mechanical and electrical equipment will be installed. Must comply with all storm water and flood control ordinances. Any work performed in the right of way will require a right of way permit.); 6) full compliance with Traffic Engineering comments (Driveway number, size, location, and design to be approved by Traffic Engineering and ALDOT and conform to AASHTO standards. Standard driveway width for two-way traffic is twenty-four feet and thirtysix feet for three lanes. Changes should be made to accommodate the standard.); 7) revision of the site plan to depict frontage trees; to be coordinated with Urban Forestry; 8) provision of a revised PUD site plan prior to the signing of the final plat; 9) completion of the Subdivision process; and 10) full compliance with all other municipal codes and ordinances. Subdivision: The plat meets the minimum requirements of the Subdivision Regulations and is recommended for Tentative Approval subject to the following condition: 1) placement of a note on the final plat stating that each lot is limited to one curb-cut each onto the service road of Government Boulevard, with the size, design and location to be approved by ALDOT and Traffic Engineering, and to comply with AASHTO standards; 2) labeling of each lot with its size in square feet, or provision of a table on the plat with the same information; 3) full compliance with Engineering comments (Show limits of the flood zone. Show minimum finished floor elevation for any buildings or structures and/or slabs, on which, mechanical and electrical equipment will be installed. Must comply with all storm water and flood control ordinances. Any work performed in the right of way will require a right of way permit.); 4) depiction of a 10- foot wide protection buffer strip along the rear of the lots, where they abut residential uses; 5) approval of all applicable federal, state and local agencies prior to the issuance of any permits or land disturbance activities; 6) provision of a revised PUD site plan prior to the signing of the final plat; and 7) full compliance with all other municipal codes and ordinances. - 3 -

- 4 -

- 5 -

- 6 -