PLANNED UNIT DEVELOPMENT STAFF REPORT Date: August 20, 2015

Similar documents
PLANNED UNIT DEVELOPMENT STAFF REPORT Date: October 19, 2017

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT August 18, 2016

McGowin Park, LLC. B-3, Community Business District

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: July 20, 2017

ZONING AMENDMENT, PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: August 8, 2013

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: November 17, 2016

PLANNED UNIT DEVELOPMENT, SIDEWALK WAIVER, & SUBDIVISION STAFF REPORT Date: November 6, 2008

PLANNED UNIT DEVELOPMENT (East), PLANNED UNIT DEVELOPMENT (West) STAFF REPORT Date: September 18, 2014

ZONING AMENDMENT & SUBDIVISION STAFF REPORT Date: November 3, 2016

ZONING AMENDMENT & SUBDIVISION STAFF REPORT Date: July 9, 2015

APPLICANT NAME SUBDIVISION NAME DEVELOPMENT NAME LOCATION. CITY COUNCIL DISTRICT Council District 4 PRESENT ZONING PROPOSED ZONING

PLANNED UNIT DEVELOPMENT & ZONING AMENDMENT STAFF REPORT Date: December 21, 2017

SUBDIVISION, PLANNED UNIT DEVELOPMENT, PLANNING APPROVAL, ZONING AMENDMENT, & SIDEWALK WAIVER REQUEST STAFF REPORT Date: February 17, 2010

JOHNNY S RV PARK SUBDIVISION

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: March 15, 2007

ZONING AMENDMENT, PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: March 5, 2009

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: April 18, 2019

ZONING AMENDMENT & SUBDIVISION STAFF REPORT Date: March 7, 2013

ZONING AMENDMENT & SUBDIVISION STAFF REPORT Date: June 18, 2015

SUBDIVISION, PLANNED UNIT DEVELOPMENT, ZONING AMENDMENT, & SIDEWALK WAIVER STAFF REPORT Date: July 19, 2018

ZONING AMENDMENT & PLANNED UNIT DEVELOPMENT STAFF REPORT Date: July 5, 2012

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: September 15, 2016

SUBDIVISION, PLANNED UNIT DEVELOPMENT, & PLANNING APPROVAL STAFF REPORT Date: February 1, 2007

ZONING AMENDMENT, PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: September 15, 2011

ZONING AMENDMENT & PLANNED UNIT DEVELOPMENT STAFF REPORT Date: June 7, 2012

ZONING AMENDMENT & SUBDIVISION STAFF REPORT Date: July 3, 2014

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: May 6, 2004

BOARD OF ZONING ADJUSTMENT STAFF REPORT Date: November 7, 2016

ZONING AMENDMENT STAFF REPORT Date: September 15, 2016

DAUPHIN CREEK ESTATES SUBDIVISION

THE CITY OF MOBILE, ALABAMA MOBILE Crry PLANNING COMMISSION

MOBILE TOWERS SUBDIVISION

ALBA BEACH SUBDIVISION, RESUBDIVISION OF LOT 17

WESTMINSTER PARK SUBDIVISION

SUBDIVISION, PLANNING APPROVAL, & REZONING STAFF REPORT Date: June 4, 2015

SUBDIVISION, PLANNED UNIT DEVELOPMENT, & REZONING STAFF REPORT Date: September 17, 2015

SOUTHERN INDUSTRIAL PARK SUBDIVISION, LOT A, RESUBDIVISION OF LOTS 7 & 8

SUBDIVISION & PLANNING APPROVAL STAFF REPORT Date: December 1, 2016

WESTMINSTER PARK PLACE SUBDIVISION

ZONING AMENDMENT & SUBDIVISION STAFF REPORT Date: March 1, 2018

BOARD OF ZONING ADJUSTMENT STAFF REPORT Date: July 6, 2015

KLUGE PLACE SUBDIVISION

HERON LANDING SUBDIVISION

ELIZA JORDAN CORNER SUBDIVISION

SUBDIVISION, PLANNED UNIT DEVELOPMENT, & REZONING STAFF REPORT Date: March 23, 2017

TULSA PARK ESTATES SUBDIVISION, RESUBDIVISION OF LOT 6

AUTUMNDALE SUBDIVISION, RESUBDIVISION OF LOTS

THE CITY OF MOBILE, ALABAMA

MCGOWIN PARK EAST OF SATCHEL PAIGE SUBDIVISION, RESUBDIVISION OF

ZONING AMENDMENT, & SUBDIVISION STAFF REPORT Date: July 24, 2008

ZONING AMENDMENT, PLANNED UNIT DEVELOPMENT & PLANNING APPROVAL STAFF REPORT Date: June 7, 2007

THE CITY OF MOBILE, ALABAMA

THE CITY OF MOBILE, ALABAMA

DAWES SWITCHING STATION SUBDIVISION

BETTA STOR-IT SUBDIVISION

MAGNOLIA SPRINGS SUBDIVISION, PHASE ONE

HAWTHORNE PLACE SUBDIVISON, RESUBDIVISION OF LOT 15 REVISED

COCHRAN FAMILY RIVERSIDE ESTATE SUBDIVISION

DEER RIVER COMMERCIAL PARK SUBDIVISION

MOBILE CITY PLANNING COMMISSION LETTER OF DECISION. June 3, 2011

AMENDMENT TO REGULATING PLAN & SUBDIVISION STAFF REPORT Date: December 15, 2016

THE WHEELER BUILDING SUBDIVISION

PALMER WOODS SUBDIVISION, PHASE III

Letter of Intent for Application requested by 30AIP Chamblee, LLC (the Applicant )

DINKINS ESTATE FAMILY SUBDIVISION

STONE HEDGE SUBDIVISION, UNIT 1, RESUBDIVISION OF LOT 40 & WEST COMMON AREA

30AIP CHAMBLEE, LLC CR Hwy. 30A West Bldg. M-1 Unit 228 Santa Rosa Beach, FL (850)

PLANNED UNIT DEVELOPMENTS (Ordinance No.: 3036, 12/3/07; Repealed & Replaced by Ordinance No.: 4166, 10/15/12)

BAY FOREST PARK SUBDIVISION, RESUBDIVISION OF LOTS 6 & 7 AND BAY FOREST PARK SUBDIVISION LOT 10, OF THE RESUBDIVISON OF LOTS 9 & 10

Cover Letter with Narrative Statement

THE BLUFFS AT CYPRESS CREEK SUBDIVISION, PHASE ONE

AMELIA LAKE SUBDIVISON, PHASES 1-2

BROADWAY THREE NOTCH ROAD SUBDIVISION

THE CI FY OF MOBILE, ALABAMA

TURTLE CREEK SUBDIVISION, PHASE THREE

THE CITY OF MOBILE, ALABAMA

BOARD OF ZONING ADJUSTMENT STAFF REPORT Date: January 9, 2017

ZONING AMENDMENT, & SUBDIVISION STAFF REPORT Date: May 17, 2007

Staff Recommendation Approval. Staff Planner Robert Davis

# 1 HOLDOVER Revised SUB CANAL SUBDIVISION

TERRY POIROUX FAMILY DIVISION SUBDIVISION

Administrative Plat Application Form

EXHIBIT D. Planned Unit Development Written Description April 13, 2016 Rouen Cove Phase II PUD

Medical Marijuana Special Exception Use Information

PLANNED DEVELOPMENT DISTRICT STANDARDS. Cadence Site

SUBJECT PARCEL(S) Property Owner(s) TMS Number Approximate Acreage Carolina Park Development, LLC

MOBILE CITY PLANNING COMMISSION LETTER OF DECISION. August 19, 2011

Sterling Meadow Subdivision

Special Land Use. SLU Application & Review Standards

Request Subdivision Variance (Sections 4.4 (b) & (d) of the Subdivision Regulations) Staff Planner Jimmy McNamara

PENNY LAKES SUBDIVISION

CONCEPTUAL MASTER PLAN CHECKLIST Major Land Development Project

AN ORDINANCE TO AMEND SECTION OF THE RAPID CITY MUNICIPAL CODE TO ALLOW FOR ADMINISTRATIVE DISSOLUTION OF PLANNED DEVELOPMENTS

Airport Rd. Lot 6 Lot 2 Lot 1. 1 Mile: Population: 1,100 Median HH Income: $51, Mile: Population: 16,300 Median HH Income: $53,500

AN ORDINANCE TO CREATE THE ALDEN RIDGE PUD As Recommended to the Lowell Township Board by the Lowell Township Planning Commission January 11, 2016

Request Conditional Use Permits (Craft Brewery, Assembly Use & Open-Air Market) Staff Recommendation Approval. Staff Planner Robert Davis

Town of Cary, North Carolina Site Plan Staff Report Centregreen Park at Weston (13-SP-067) Town Council Quasi-Judicial Hearing April 3, 2014

ARTICLE 5 GENERAL REQUIREMENTS

STAFF REPORT. Guttman Development Group, LLC. PUD-R (Residential Planned Unit Development Plan)

WRIGHT TOWNSHIP Ottawa County 1565 Jackson Street, P.O. Box 255, Marne, Michigan 49435

Transcription:

# 3 HOLDOVER Revised ZON2015-01733 PLANNED UNIT DEVELOPMENT STAFF REPORT Date: August 20, 2015 DEVELOPMENT NAME LOCATION Joseph N. Asarisi, P.E. North side of Airport Boulevard 212 ± West of Mckeena Court. CITY COUNCIL DISTRICT District 7 PRESENT ZONING AREA OF PROPERTY B-3, Community Business District 1.1± acres CONTEMPLATED USE Planned Unit Development Approval to amend a previously approved Planned Unit Development to allow shared access and parking between multiple building sites. TIME SCHEDULE FOR DEVELOPMENT Not specified. ENGINEERING COMMENTS ADD THE FOLLOWING NOTES TO THE PUD SITE PLAN: 1. The approval of all applicable federal, state, and local agencies (including all storm water runoff, wetland and floodplain requirements) will be required prior to the issuance of a Land Disturbance permit. The Owner/Developer is responsible for acquiring all of the necessary permits and approvals. TRAFFIC ENGINEERING COMMENTS The proposed drive-thru on west side of building is not desirable as currently shown, as traffic in the middle has vehicles opposing it on both sides. An option is to make the circulation counterclockwise around the building, with 20 aisle and angled parking. Another alternative could be a striped separation, since the drive-thru lane can be as narrow as 9. This option is/ could be feasible, depending upon the order station location, and anticipated queue length. If the queue space extends beyond the side of the building to the rear, the drive aisle is not wide enough to accommodate two circulation lanes and a drive-thru lane. Revised for the September 3 rd meeting: The driving aisles around the site have been designated for one-way traffic, and sufficient width has been provided for the driving aisle and drive-thru queue lane. With ninety-degree parking

# 3 HOLDOVER Revised ZON2015-01733 and one-way designation, the arrows proposed in the travel aisle will need to be thermoplastic material (not paint), to extend the life of the markings. URBAN FORESTRY COMMENTS Property to be developed in compliance with state and local laws that pertain to tree preservation and protection on both city and private properties (State Act 61-929 and City Code Chapters 57 and 64). FIRE DEPARTMENT COMMENTS All projects within the City Limits of Mobile shall comply with the requirements of the City of Mobile Fire Code Ordinance (2012 International Fire Code). Projects outside the City Limits of Mobile, yet within the Planning Commission Jurisdiction fall under the State or County Fire Code (2012 IFC). REMARKS The applicant is requesting Planned Unit Development Approval to amend a previously approved Planned Unit Development to allow shared access and parking between multiple building sites. Planned Unit Development (PUD) review examines the site with regard to its location to ensure that it is generally compatible with neighboring uses; that adequate access is provided without generating excess traffic along minor residential streets in residential districts outside the PUD; and that natural features of the site are taken into consideration. PUD review also examines the design of the development to provide for adequate circulation within the development; to ensure adequate access for emergency vehicles; and to consider and provide for protection from adverse effects of adjacent properties as well as provide protection of adjacent properties from adverse effects from the PUD. PUD approval is site plan specific, thus if any new construction is anticipated that will change an approved site plan, an application to amend an existing, approved PUD must be made prior to any construction activities. This site most recently appeared before the Planning Commission at its May 21, 2015 and April 16, 2015 meeting where the Commission approved amended PUD applications to allow a proposed carwash development on Lot 5 and a proposed restaurant on Lot 3. This site originally appeared before the Commission at its January 19, 2012 meeting where the Commission approved a 5-lot subdivision and PUD request to allow shared access and parking between five building sites. As PUD approval is site plan specific, a condition of approval required the applicant to submit new PUD applications to amend the existing PUD for any future development, hence the current application at hand. The proposed development of Lot 4 will consist of a 6,745± sf building, to be comprised of 1 suite planned for a retail use and 3 suites proposed as restaurant uses, with a total 2,087± sf of sidewalk / outdoor dining area abutting the southern and eastern sides of the building. As proposed, the anticipated mix of uses will require 81 parking spaces. 83 new parking spaces are proposed, which exceeds the minimum requirements of the Zoning Ordinance for required onsite parking spaces; however, the site plan should be revised to reflect accurate parking calculations. - 2 -

# 3 HOLDOVER Revised ZON2015-01733 It should be pointed out that on-site traffic circulation is a concern due to a proposed drive-thru adjacent to Suite A, along the western side of the building. As no information was provided regarding the location of the order menu or service window, Staff is not able to determine if a sufficient number of queuing spaces will be provided. As such, the site layout should be revised to coincide with Traffic Engineering comments and illustrate full compliance with Section 64-4.F. of the Zoning Ordinance, regarding design standards for drive-thru businesses. Parking lot lighting will be required as a result of the new development. Any new lighting on the site must comply with the requirements of Sections 64-4.A.2., 64-6.A.3.c., and 64-6.A.8. of the Zoning Ordinance and photometric plans will be required at the time of permitting for land disturbance. These notes appear on the site plan and should be retained on any revised site plan. In regards to trees and landscaping, compliant landscaping data is depicted on the site plan; however, the provision of frontage trees on the site plan is required along Airport Boulevard. As such, a compliant number of frontage trees should be illustrated on the revised site plan. Dumpsters and notes are illustrated on the site in compliance with Section 64-4.D.9. of the Zoning Ordinance, to include a connection to sanitary sewer, and should be retained on any revised site plan. It should be noted that no information was provided regarding signage. Although PUD review can allow flexibility with the Sign Regulations of the Zoning Ordinance, each proposed business on Lot 4 will be permitted 1 wall sign by-right and 1 tenant panel on a freestanding sign. Any desired increase in the signage allowance will require an approved Sign Variance by the Board of Zoning Adjustment or a new PUD application. RECOMMENDATION It is recommended that this application be heldover to the meeting of September 17 th with revisions due by August 31 st to allow the applicant to address the following: 1) Revision of the site layout to depict full compliance with Section 64-4.F. of the Zoning Ordinance regarding design standards for drive-thru businesses; 2) Revision of the site layout to depict compliance with Traffic Engineering comments (The proposed drive-thru on west side of building is not desirable as currently shown, as traffic in the middle has vehicles opposing it on both sides. An option is to make the circulation counterclockwise around the building, with 20 aisle and angled parking. Another alternative could be a striped separation, since the drive-thru lane can be as narrow as 9. This option is/ could be feasible, depending upon the order station location, and anticipated queue length. If the queue space extends beyond the side of the building to the rear, the drive aisle is not wide enough to accommodate two circulation lanes and a drive-thru lane.); 3) Provision of compliant parking calculations on the revised site plan; and 4) Illustration of a compliant number of frontage trees along Airport Boulevard. - 3 -

# 3 HOLDOVER Revised ZON2015-01733 Revised for the September 3 rd meeting: The application was heldover from the August 20 th meeting to allow staff to review the revised submittal and meet with the applicant s representative. The revised site layout depicts full compliance with Section 64-4.F. of the Zoning Ordinance regarding design standards for drivethru businesses. The applicant has also updated the tenant mix for the proposed suites and now desires only 2 suites to be occupied by restaurant uses and the other 2 set aside for retail. The applicant has also revised the proposed outdoor seating areas. As currently proposed, a total of 63 parking spaces are required 54 for the restaurant and outdoor seating areas and 9 spaces for retail. The applicant is proposing 76 on-site parking spaces, which exceeds the minimum requirements. It should be pointed out that landscape data is illustrated on the site plan; however, the depiction of frontage trees along Airport Boulevard should be illustrated on the revised site plan. RECOMMENDATION the following conditions: The application is recommended for approval, subject to 1) Depiction of frontage trees along Airport Boulevard on the revised site plan; 2) Retention of landscaping illustrations and notes on the revised site plan; 3) Retention of lighting notes on the revised site plan; 4) Retention of all dumpsters and associated notes on the revised site plan; 5) Compliance with Engineering comments (ADD THE FOLLOWING NOTES TO THE PUD SITE PLAN: 1. The approval of all applicable federal, state, and local agencies (including all storm water runoff, wetland and floodplain requirements) will be required prior to the issuance of a Land Disturbance permit. The Owner/Developer is responsible for acquiring all of the necessary permits and approvals.); 6) Compliance with Traffic Engineering comments (The driving aisles around the site have been designated for one-way traffic, and sufficient width has been provided for the driving aisle and drive-thru queue lane. With ninety-degree parking and one-way designation, the arrows proposed in the travel aisle will need to be thermoplastic material (not paint), to extend the life of the markings.); 7) Compliance with Urban Forestry comments (Property to be developed in compliance with state and local laws that pertain to tree preservation and protection on both city and private properties (State Act 61-929 and City Code Chapters 57 and 64).); 8) Compliance with Fire Department comments (All projects within the City Limits of Mobile shall comply with the requirements of the City of Mobile Fire Code Ordinance (2012 International Fire Code). Projects outside the City Limits of Mobile, yet within the Planning Commission Jurisdiction fall under the State or County Fire Code (2012 IFC).); and 9) Any desired increase in the signage allowance will require an approved Sign Variance by the Board of Zoning Adjustment or a new PUD application. - 4 -