PROPERTY INSPECTION REPORT

Similar documents
PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT

Pre-Pour Foundation Inspection Report. Point to Point Inspections, PLLC Peter J. Day TREC Lic. # 21160

Duke's Home Inspections

PROPERTY INSPECTION REPORT

Horsley Home Inspection

Inspection Report Client's Name Withheld Property Address:

5 point Seller inspection. May 2016 Elite Inspection Group P.O. Box 2205 Frisco, TX

INSPECTION GROUP. Providing Peace of Mind One home at a time Since 1989

OBTAINING A CERTIFICATE OF OCCUPANCY FOR UNAPPROVED DWELLING UNITS

NEBRASKA REAL ESTATE COMMISSION SELLER PROPERTY CONDITION DISCLOSURE STATEMENT Residential Real Property

HOUSING CODE CHECKLIST FOR RENTAL INSPECTIONS

HOME INVESTMENTS PARTNERSHIP PROGRAM Local Housing Standards Checklist

Real Estate Transfer Disclosure Statement

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

Schedule 2.2 NOTICE OF INTENT TO SELL

SELLER S PROPERTY DISCLOSURE STATEMENT

OREGON SELLER S PROPERTY DISCLOSURE STATEMENT

Sonatta Camara for Property known as.

What else are FHA appraisers looking for?

PROPERTY CONDITION DISCLOSURE STATEMENT (PCDS)

SELLER'S PROPERTY CONDITION DISCLOSURE

PETITION B Reductions in Maintenance and Services, Habitability Problems, and/or Failure to Provide Maintenance and Services Required by Law

Inspection Proposal 3/7/2013. Client: Phone:

AN ACT. relating to seller's disclosures in connection with residential BE IT ENACTED BY THE LEGISLATURE OF THE STATE OF TEXAS:

SELLER'S DISCLOSURE OF REAL PROPERTY CONDITION REPORT

STATE OF SOUTH CAROLINA RESIDENTIAL PROPERTY CONDITION DISCLOSURE STATEMENT

Summary of Oregon Home Inspector Certification Law (ORS 701) and Standards of Practice for Home Inspections

Housing Authority of the County of San Bernardino

TEXAS ASSOCIATION OF REALTORS

STATE OF SOUTH CAROLINA RESIDENTIAL PROPERTY CONDITION DISCLOSURE STATEMENT

RENTER'S INSPECTION WORKSHEET Free form provided at

ACCESSORY DWELLING UNITS

MUNICIPAL HOUSING REHABILITATION PROGRAM HANDBOOK

SELLER'S DISCLOSURE STATEMENT

What is a home inspection?

FY 2018 FEE SCHEDULE (Effective )

WASHINGTON SELLER S RESIDENTIAL PROPERTY DISCLOSURE STATEMENT

SELLER DISCLOSURE STATEMENT IMPROVED PROPERTY

Joe Sample. Property Address: 1234 Sample St. Atlanta GA Inspector: Jason David. Residential Inspector of America, Inc.

House Bill 2140 Sponsored by Representative BOONE (Presession filed.)

Example for a Single Family Home Annual Application fee: $50.00 Inspection fee $ (required once every four years) Total fee: $185.

I. Project Administration

Section 23.0 HOUSING QUALITY STANDARDS (HQS) INSPECTION POLICIES

SELLER'S PROPERTY CONDITION DISCLOSURE SELLER'S AGENT - COMPLETE THIS SECTION ONLY! NOTICE FROM COMPANY INSTRUCTIONS TO SELLER

DESCRIPTION OF LANDLORD'S WORK & TENANT'S WORK

ORDINANCE NO

DOCTOR HOME INSPECTIONS WEST 19 TH ST, NORTH VANCOUVER, BC, V7M 1X HOME INSPECTION CONTRACT

Seller s Property Disclosure Residential

SELLER S PROPERTY CONDITION DISCLOSURE This is a legally binding document. If not understood, consult an attorney.

Worldwide ERC Statement of Use: Relocation Property Assessment

SELLER S DISCLOSURE OF REAL PROPERTY CONDITION REPORT State of Delaware Approved by the Delaware Real Estate Commission 5/11/17 (effective 10/1/17)

-PLUMBING- BUILDING PERMIT APPLICATION PACKET

1. The Property has the items checked below: Write Yes (Y), No (N), or Unknown (U). Range Oven Microwave Dishwasher.

CHAPTER 10 MINIMUM STANDARDS FOR RESIDENTIAL PROPERTY AND HOUSING

VIEW POINTE MAINTENANCE CORPORATION

Ordinance 991 CHAPTER 91 RENTAL HOUSING CODE

City of Wausau Building, Housing and Zoning Fee Schedule 2019

Paul Smith DBA Curry Home Inspection, LLC OCHI # 1757 CCB # ODA # AG-L CPA INSPECTION AGREEMENT

SELLER S PROPERTY CONDITION DISCLOSURE STATEMENT

TEXAS ASSOCIATION OF REALTORS

APPENDIX A BUILDING PERMIT AND RELATED FEES

Attic Floor Bedrooms 1 & 2 Family Dwellings

COMPTON HOUSING AUTHORITY 600 North Alameda Street Compton, CA (310) ~ Fax (310) HOUSING CHOICE VOUCHER PROGRAM

SELLER S DISCLOSURE STATEMENT (RESIDENTIAL IMPROVED PROPERTY)

CHAPTER 10 ARTICLE II DIVISION 2: MINIMUM STANDARDS

Fee Type How Determined Rate Permit Processing Charge Flat Permit or Plan Review Submittal $32.00

Form 17 SELLER DISCLOSURE STATEMENT IMPROVED PROPERTY

ACCESSORY DWELLING UNITS

TOWN OF HERNDON, VIRGINIA ORDINANCE MAY 26, 2015

City of Oregon City. Community Development Building Division Fee Schedule Effective April 1, 2016 BUILDING DIVISION

Grinder Pump & Greywater Systems Policy May 2016

C. Entry Move-In Comments Landlord's Move-Out Comments Ceiling & Walls Paint & Wallpaper Doors & Door Stops

STATE OF NEW YORK OFFICE OF THE STATE COMPTROLLER 110 STATE STREET ALBANY, NEW YORK 12236

Housing Quality Standards 24 CFR

WISCONSIN REAL ESTATE CONDITION REPORT 1

SELLER'S DISCLOSURE STATEMENT. (Property Address) located in the municipality of (if incorporated), County of, Missouri.

14.46 BUILDING SEWER INSPECTIONS

Property Details 916 Youngs Road

Features of 5400 Little Parkway, Sherrills Ford, NC 28673

Plan A. 1,573(A2) -1,587(A1) Square Feet Three-Story 2 bedrooms 2.5 bathrooms Bedroom Downstairs Great Room Kitchen with Breakfast Island 2-Car Garage

PROPERTY CONDITION Checklist

~ Farms & Estates Realty ~ Premier Properties. The Cuckoo s Nest

Disclosure of Information on Lead-Based Paint and/or Lead-Based Paint Hazards

attached not attached Garage Garage Door Openers number of units: number of remotes: Satellite Dish & Controls

TEXAS ASSOCIATION OF REALTORS SELLER'S DISCLOSURE NOTICE

FREQUENTLY ASKED QUESTIONS about on-site wastewater (septic) systems. I want to build a new home served by a septic system. What do I need to do?

City of Richmond Municipal Code

INSPECTION REPORT DISCLAIMER This report was provided by the seller of the property. Neither ServiceLink Auction, LLC nor Hudson and Marshall, LLC

Preventive Maintenance Program

The Business of Infrared Home Inspections

INVENTORY AND CONDITION FORM CONCERNING THE PROPERTY AT

COUNCIL OF CO-OWNERS OF THE WESTERLIES CONDOMINIUM POLICY RESOLUTION NO (Policy Concerning Maintenance Responsibilities)

ORDINANCE NO ORDINANCE TO AMEND AN ORDINANCE CODIFIED IN THE CODE OF THE TOWNSHIP OF NUTLEY, CHAPTER 272, ENTITLED CONSTRUCTION CODES, UNIFORM

Quality Control Biennual Inspections B. INITIAL HQS INSPECTION [24 CFR (a) (b) (2)] Timely Initial HQS Inspection The PHA will inspect

Tiny House on Wheels A Tiny House

PROCEDURE FOR OBTAINING A DECK/PORCH PERMIT

TENANT DESIGN MANUAL UPDATED JUNE 2015

PHASE 1 (PRE-POUR) PROPERTY INSPECTION REPORT

RESIDENTIAL PROPERTY DISCLOSURE FORM

Transcription:

FW Property nspectors Rowlett, Texas 972-325-6070 WWW.FW-Propertynspectors.com PROPERTY NSPECTON REPORT Prepared For: Address: SomewhereTexas By: Jack Shouse TREC # 21100 11/5/2014 PURPOSE, LMTATONS AN NSPECTOR / CLENT RESPONSBLTES This property inspection report may include an inspection agreement (contract), addenda, and other information related to property conditions. f any item or comment is unclear, you should ask the inspector to clarify the findings. t is important that you carefully read ALL of this information. This inspection is subject to the rules ( Rules ) of the Texas Real Estate Commission ( TREC ), which can be found at www.trec.texas.gov. The TREC Standards of Practice (Sections 535.227-535.233 of the Rules) are the minimum standards for inspections by TREC licensed inspectors. An inspection addresses only those components and conditions that are present, visible, and accessible at the time of the inspection. While there may be other parts, components or systems present, only those items specifically Promulgated by the Texas Real Estate Commission (TREC) P.O. Box 12188, Austin, TX 78711-2188 (512) 936-3000 (http://www.trec.texas.gov). RE 7-3 (Revised 05/2013)

FW Property nspectors Rowlett, Texas 972-325-6070 WWW.FW-Propertynspectors.com noted as being inspected were inspected. The inspector is NOT required to turn on decommissioned equipment, systems, and utility services or apply an open flame or light a pilot to operate any appliance. The inspector is NOT required to climb over obstacles, move furnishings or stored items. The inspection report may address issues that are code-based or may refer to a particular code; however, this is NOT a code compliance inspection and does NOT verify compliance with manufacturer s installation instructions. The inspection does NOT imply insurability or warrantability of the structure or its components. Although some safety issues may be addressed in this report, this inspection is NOT a safety/code inspection, and the inspector is NOT required to identify all potential hazards. n this report, the inspector shall indicate, by checking the appropriate boxes on the form, whether each item was inspected, not inspected, not present or deficient and explain the findings in the corresponding section in the body of the report form. The inspector must check the eficient () box if a condition exists that adversely and materially affects the performance of a system or component or constitutes a hazard to life, limb or property as specified by the TREC Standards of Practice. General deficiencies include inoperability, material distress, water penetration, damage, deterioration, missing components, and unsuitable installation. Comments may be provided by the inspector whether or not an item is deemed deficient. The inspector is not required to prioritize or emphasize the importance of one deficiency over another. Some items reported may be considered life-safety upgrades to the property. For more information, refer to Texas Real Estate Consumer Notice Concerning Recognized Hazards or eficiencies THS PROPERTY NSPECTON S NOT A TECHNCALLY EXHAUSTVE NSPECTON OF THE STRUCTURE, SYSTEMS OR COMPONENTS. The inspection may not reveal all deficiencies. A real estate inspection helps to reduce some of the risk involved in purchasing a home, but it cannot eliminate these risks, nor can the inspection anticipate future events or changes in performance due to changes in use or occupancy. t is recommended that you obtain as much information as is available about this property, including any seller s disclosures, previous inspection reports, engineering reports, building/remodeling permits, and reports performed for or by relocation companies, municipal inspection departments, lenders, insurers, and appraisers. You should also attempt to determine whether repairs, renovation, remodeling, additions, or other such activities have taken place at this property. t is not the inspector s responsibility to confirm that information obtained from these sources is complete or accurate or that this inspection is consistent with the opinions expressed in previous or future reports. TEMS ENTFE N THE REPORT O NOT OBLGATE ANY PARTY TO MAKE REPARS OR TAKE OTHER ACTONS, NOR S THE PURCHASER REQURE TO REQUEST THAT THE SELLER TAKE ANY ACTON. When a deficiency is reported, it is the client s responsibility to obtain further evaluations and/or cost estimates from qualified service professionals. Any such follow-up should take place prior to the expiration of any time limitations such as option periods. Promulgated by the Texas Real Estate Commission (TREC) P.O. Box 12188, Austin, TX 78711-2188 (512) 936-3000 (http://www.trec.texas.gov). RE 7-3 (Revised 05/2013)

FW Property nspectors Rowlett, Texas 972-325-6070 WWW.FW-Propertynspectors.com Evaluations by qualified tradesmen may lead to the discovery of additional deficiencies which may involve additional repair costs. Failure to address deficiencies or comments noted in this report may lead to further damage of the structure or systems and add to the original repair costs. The inspector is not required to provide follow-up services to verify that proper repairs have been made. Property conditions change with time and use. For example, mechanical devices can fail at any time, plumbing gaskets and seals may crack if the appliance or plumbing fixture is not used often, roof leaks can occur at any time regardless of the apparent condition of the roof, and the performance of the structure and the systems may change due to changes in use or occupancy, effects of weather, etc. These changes or repairs made to the structure after the inspection may render information contained herein obsolete or invalid. This report is provided for the specific benefit of the client named above and is based on observations at the time of the inspection. f you did not hire the inspector yourself, reliance on this report may provide incomplete or outdated information. Repairs, professional opinions or additional inspection reports may affect the meaning of the information in this report. t is recommended that you hire a licensed inspector to perform an inspection to meet your specific needs and to provide you with current information concerning this property. TEXAS REAL ESTATE CONSUMER NOTCE CONCERNNG HAZARS OR EFCENCES Each year, Texans sustain property damage and are injured by accidents in the home. While some accidents may not be avoidable, many other accidents, injuries, and deaths may be avoided through the identification and repair of certain hazardous conditions. Examples of such hazards include: malfunctioning, improperly installed, or missing ground fault circuit protection (GFC) devices for electrical receptacles in garages, bathrooms, kitchens, and exterior areas; Malfunctioning arc fault protection (AFC) devices; Ordinary glass in locations where modern construction techniques call for safety glass; malfunctioning or lack of fire safety features such as smoke alarms, fire-rated doors in certain locations, and functional emergency escape and rescue openings in bedrooms; Malfunctioning carbon monoxide alarms; Excessive spacing between balusters on stairways and porches; mproperly installed appliances; mproperly installed or defective safety devices; and Lack of electrical bonding and grounding. To ensure that consumers are informed of hazards such as these, the Texas Real Estate Commission (TREC) has adopted Standards of Practice requiring licensed inspectors to report these conditions as eficient when performing an inspection for a buyer or seller, if they can be reasonably determined. These conditions may not have violated building codes or common practices at the time of the construction of the home, or they may have been grandfathered because they were present prior Promulgated by the Texas Real Estate Commission (TREC) P.O. Box 12188, Austin, TX 78711-2188 (512) 936-3000 (http://www.trec.texas.gov). RE 7-3 (Revised 05/2013)

FW Property nspectors Rowlett, Texas 972-325-6070 WWW.FW-Propertynspectors.com to the adoption of codes prohibiting such conditions. While the TREC Standards of Practice do not require inspectors to perform a code compliance inspection, TREC considers the potential for injury or property loss from the hazards addressed in the Standards of Practice to be significant enough to warrant this notice. Contract forms developed by TREC for use by its real estate licensees also inform the buyer of the right to have the home inspected and can provide an option clause permitting the buyer to terminate the contract within a specified time. Neither the Standards of Practice nor the TREC contract forms require a seller to remedy conditions revealed by an inspection. The decision to correct a hazard or any deficiency identified in an inspection report is left to the parties to the contract for the sale or purchase of the home. ATONAL NFORMATON PROVE BY NSPECTOR THE NFORMATON PROVE N THE SECTON "ATONAL NFORMATON PROVE BY THE NSPECTOR" S NOT REQURE BY THE COMMSSON AN MAY CONTAN CONTRACTUAL TERMS BETWEEN THE NSPECTOR AN YOU, AS THE CLENT. THE COMMSSON OES NOT GOVERN CONTRACTUAL TERMS BETWEEN THE PARTES. F YOU O NOT UNERSTAN THE EFFECT OF ANY CONTRACTUAL TERM CONTANE N THS SECTON OR ANY ATTACHMENTS, CONSULT AN ATTORNEY BEFORE SGNNG. f you have any complaint about our inspection, YOU MUST notify us in writing within seven days after you discover any problem, and let us reinspect before changing the condition, except in emergencies. YOU AGREE that, to the extent allowed by law, any damages for breach of this contract or report are LMTE to the amount of the inspection fee. THS REPORT CANNOT AN OES NOT REPRESENT THE OPERATON OR CONTON OF ANY TEMS AFTER THE ATE AN TME OF THS NSPECTON. THS REPORT S OUR NVOCE. NSPECTON FEE: $xxx Paid Check # xxx Promulgated by the Texas Real Estate Commission (TREC) P.O. Box 12188, Austin, TX 78711-2188 (512) 936-3000 (http://www.trec.texas.gov). RE 7-3 (Revised 05/2013)

FW Property nspectors Rowlett, Texas 972-325-6070 WWW.FW-Propertynspectors.com FOUNATON NFORMATON Most major foundation movement can be prevented if the moisture level in the soil supporting your foundation is uniformly maintained. Foundation problems associated with expansive clay are usually caused by a lack of moisture in the soil. As the soil dries, it shrinks and can cause foundation settlement. n some instances, too much moisture in the soil can also cause foundation movement. As the soil absorbs moisture, it expands and can cause foundation upheaval. Think of the soil as a sponge. Place the sponge under a faucet, and then squeeze the water out. Although a majority of the water is gone, the sponge is still moist to the touch. The ideal condition of the soil around your home is like that sponge - not drippy wet, not bone dry, moist to the touch. The best way to maintain a consistent moisture level is with a properly regulated automatic sprinkler system. f you are more disciplined than most of us, the same result can be accomplished by placing soaker hoses eighteen inches from the foundation and regulating the water flow to onefourth inch in height until water is observed standing on the ground. This process should be repeated as often as necessary to maintain the uniform moisture level described above. uring hot and dry seasons, the South and West sides may require more watering than the North and East sides, which are shaded and not exposed to as much direct sun. On gabled end or sides of the house, there is no run-off; so more watering will probably be required. Promulgated by the Texas Real Estate Commission (TREC) P.O. Box 12188, Austin, TX 78711-2188 (512) 936-3000 (http://www.trec.texas.gov). RE 7-3 (Revised 05/2013)

FW Property nspectors Rowlett, Texas 972-325-6070 WWW.FW-Propertynspectors.com No amount of structural work on a foundation will overcome poor drainage. Surface water, whether from rain or watering, should not be allowed to accumulate around or under your foundation. Proper drainage may require recontouring the existing grade, placing soil around the perimeter of the foundation, extending downspouts and placing splash blocks to prevent soil erosion or other specifics peculiar to the site. Care should be taken to insure that soil is at least one to two inches below the top of the perimeter grade beams. The soil should be sloped approximately one inch per foot to drain at least eighteen inches from the perimeter of the foundation. Guttering is not necessary where proper drainage is provided. mproper drainage will make it virtually impossible to maintain a consistent moisture level around the entire perimeter of your foundation. Most flowers and small shrubs do not cause foundation problems. However, trees and large shrubs with shallow root systems can cause foundation problems. These root systems can grow under the foundation, and as they grow in diameter, produce an upheaval. These large trees and plants also remove tremendous amounts of water from the soil. n certain instances, root severing at the foundation may be recommended. deally, trees should be planted far enough away from your home to keep the roots of mature trees away from your foundation. Promulgated by the Texas Real Estate Commission (TREC) P.O. Box 12188, Austin, TX 78711-2188 (512) 936-3000 (http://www.trec.texas.gov). RE 7-3 (Revised 05/2013)

=nspected N=Not nspected NP=Not Present =eficient N NP. STRUCTURAL SYSTEMS A. Foundations Type of Foundation(s): Pier and Beam Comments: The foundation appears to be functioning as intended. The crawl space ventilation is supplied by a timed fan in the West end of the foundation. t runs for 2 hours daily. By today s standards there should be a vent within 3 feet of each corner in a crawl space. B. Grading & rainage Comments: The gutter extensions are not connected on the West end of the house. The pool pump area should be made to drain away from the house. Air condenser behind garage should be leveled to prevent damage to the pump. The gutter should be extended to move the rain water away from the building. Jack Shouse TREC # 21100 Phone 972-325-6070 Page 7 of 17

=nspected N=Not nspected NP=Not Present =eficient N NP C. Roof Covering Materials Type(s) of Roof Covering: Metal roof with standing seams Viewed From: Ground and balcony with binoculars. Comments: The skylights do not appear to be leaking at this time but do recommend to get them re-caulked by a roofing contractor. Roof Structure & Attic Viewed From: Walking attic in garage office and upstairs of main house. Approximate Average epth of nsulation: Office 8 inches and house 6 inches Comments: Office attic Upstairs attic Jack Shouse TREC # 21100 Phone 972-325-6070 Page 8 of 17

=nspected N=Not nspected NP=Not Present =eficient N NP E. Walls (nterior & Exterior) Comments: The gutter on the front porch is not draining properly and is causing damage to the fascia board. Paint is very thin and chipping on the fascia board on garage office which will lead to moisture damage if not repaired. F. Ceilings & Floors Comments: G. oors (nterior & Exterior) Comments: H. Windows Comments: All screens were not installed. Screens are in garage attic.. Stairways (nterior & Exterior) Comments: For child safety reasons the maximum distance between stair rail bannisters should be no more than 4 inches. J. Fireplace/Chimney - Comments: Propane gas lighter. Jack Shouse TREC # 21100 Phone 972-325-6070 Page 9 of 17

=nspected N=Not nspected NP=Not Present =eficient N NP K. Porches, Balconies, ecks, and Carports Comments: L. Other Comments:. ELECTRCAL SYSTEMS A. Service Entrance and Panels Comments: 200 AMP Main house. B. Sub-Panel in garage and main 100 amp panel in office. Master bedroom closet main panel Garage sub-panel Garage Office 100 amps service panel Jack Shouse TREC # 21100 Phone 972-325-6070 Page 10 of 17

=nspected N=Not nspected NP=Not Present =eficient N NP B. Branch Circuits, Connected evices, and Fixtures Type of Wiring: Copper Comments: The kitchen countertop, the outdoor porches, and the garage receptacles are not GFC protected. Recommend having a licensed and insured electrical contractor install GFC protection for these areas.. HEATNG, VENTLATON AN AR CONTONNG SYSTEMS N A. Heating Equipment Type of System: Heat pump Energy Source: Electric Comments: Not inspected due to the outside temperature of 90 degrees. B. Cooling Equipment Type of System: Heat Pump Split system Comments: The main downstairs air conditioning cooling differential between the return and the outlet register was only 8 degrees which normally should be between 14 to 21 degrees. recommend to have it serviced by a licensed and insured HVAC contractor. Note; The downstairs air handler is in the pantry in the kitchen. C. ucts: The air ducts under the main living area had a lot of insulation falling off. Probably contributing to the deficient cooling in this area. Jack Shouse TREC # 21100 Phone 972-325-6070 Page 11 of 17

=nspected N=Not nspected NP=Not Present =eficient N NP V. PLUMBNG SYSTEM A. Water Supply System and Fixtures Location of water meter: Across the lake to the far north side of the property. Location of main water supply valve: West end of garage in box. Static water pressure reading: 75 psi Comments: C. rains, Wastes, and Vents Comments: Support straps broken lose on the toilet line under the hall bath and is currently supported by scrap pipe. Scrap pipe Broken hanger strap C. Water Heating Equipment Energy Source: Electric Capacity: 50 gallon upstairs and downstairs Comments: NP. Hydro-Massage Therapy Equipment Comments: NP E. Other Comments: Jack Shouse TREC # 21100 Phone 972-325-6070 Page 12 of 17

=nspected N=Not nspected NP=Not Present =eficient N NP V. APPLANCES A ishwasher Comments: Ran through a normal cycle. The screws to secure the dishwasher to the bottom of the countertop are lose. B. Food Waste isposer Comments: NP C. Range Hood and Exhaust Systems Comments:. Ranges, Cooktops, and Ovens Comments: Electric double ovens and cooktop E. Built-in Microwave Oven Comments: Heated cup of water F. Mechanical Exhaust Vents and Bathroom Heaters Comments: G. Garage oor Operators Comments: Both garage door openers need the down force adjusted. They will reverse but too much resistance required. H. ryer Exhaust Systems Comments:. Other Comments: Trash compactor V. OPTONAL SYSTEMS NP A. Landscape rrigation (Sprinkler) Systems B Swimming Pools, Spas, Hot Tubs, and Equipment: The remote control in the deck floor near the spa is disconnected due to varmints. The gate to a pool area should be self-closing and self-locking for child safety. All doors exiting to the pool area should have a distinct alarm for child safety. Unable to verify the blower works as the delay to come on was 30 minutes. Jack Shouse TREC # 21100 Phone 972-325-6070 Page 13 of 17

=nspected N=Not nspected NP=Not Present =eficient N NP Cartridge filter Polaris cleaner Polaris pump Laars heater Aqualink Control Panel Blower electrical connector lose Jack Shouse TREC # 21100 Phone 972-325-6070 Page 14 of 17

=nspected N=Not nspected NP=Not Present =eficient N NP Pool pump Pool equipment breaker. Outbuildings: 3 car garage, shop and 266 square foot office. NP E. Private Water Wells Jack Shouse TREC # 21100 Phone 972-325-6070 Page 15 of 17

=nspected N=Not nspected NP=Not Present =eficient N NP E. Private Sewage isposal (Septic) Systems: The anaerobic (Old System) has not been pumped in 2 to 4 years and recommend it be cleaned. The homeowner advised that the Gray Water which is everything but the toilets is running down the hill to a low area. All home drains should be treated in the septic system and recommend that the 2 inch Gray Water drain be connected to the main septic system and the main system be enlarged if necessary by a licensed plumber or a licensed waste water system installer. 2 inch line Main 3 inch cleanout Septic Tank Location SW corner of yard 2 inch gray water line NW corner of yard Lateral line 6th fence post 33 feet 5 th fence post Tanks approx.. 8 inches deep 41 feet Clean out plugs in tank tops 54 feet Clean out House 54 feet Jack Shouse TREC # 21100 Phone 972-325-6070 Page 16 of 17

=nspected N=Not nspected NP=Not Present =eficient N NP NP F. Other Jack Shouse TREC # 21100 Phone 972-325-6070 Page 17 of 17