Large Building Air Leakage Testing

Similar documents
A STUDY ON AN ESTIMATION METHOD OF THE EFFECTIVE OPENING AREA OF ENTRANCE DOORS AND WINTER AIRFLOW RATE INTO ATRIUM BUILDINGS

NFPA (2012). In a high-rise building, stairwell pressurization systems typically utilize multiple fans distributed over the height of the stair, a duc

On Smoke Control by Pressurization in Stairwells and Elevator Shafts

High-Rise Fire Sample Scenario with Stairwell Pressurization by Steve Kerber Fire Engineering Simulation

On Smoke Control by Pressurization in Stairwells and Elevator Shafts

Protecting the Stair Enclosure in Tall Buildings Impacted by Stack Effect

Presentation By. Chris Poujol. Jeffery Rodriguez. James Rigley

Stairwell Pressurization in a Cold Climate

ERRATA AND REVISIONS MEASURES FOR FIRE SAFETY IN HIGH BUILDINGS

Etobicoke York Community Council Item [#], as adopted by City of Toronto Council on [date] Draft Zoning By-law Amendment (March 20, 2019)

HOW TO MAKE POSITIVE CHANGE AROUND YOUR APARTMENT BUILDING

Available online at ScienceDirect. Energy Procedia 78 (2015 )

HOW TO CREATE AN APPRAISAL

ROOM NUMBERING STANDARDS

Lutron Stairwell Fixture Solutions

HOUSING TYPES AND CHARACTERISTICS

ASHRAE STANDARD 62.1 VENTILATION ANALYSIS UNIVERSITY RIDGE AT EAST STROUDSBURG UNIVERSITY EAST STROUDSBURG, PA PREPARED FOR: JAE-WEON JEONG, PH.D.

measures of apartment buildings

Promenade. Eco-Living at the District. hers. pool & exercise facility. recycled materials. in utilities. hot tub

Where rivers connect

EVALUATION OF FIRE SERVICE POSITIVE PRESSURE VENTILATION TACTICS ON HIGH-RISE BUILDINGS

The effect of the wind speed velocity on the stack pressure in medium-rise buildings in cold region of China

Understanding Accessibility Features to Meet Housing Needs

Orange County Housing Report: Like a Model Home. November 4, Good morning!

Understanding Accessibility Features to Meet Housing Needs

ADAPTABLE DESIGN GUIDELINES

Passive Cooling Measures for Multi-Unit Residential Buildings

KIMBELL ART MUSEUM - LOUIS KAHN Forth Worth, Texas THE UNPROGRAMMED Gijs Loomans

SMALLTIMORE. A Heart and Home. Broad View of Living Small broadhurst architects

LeaseCalcs: Expand Without Reducing Profits? Yes!

215 Ingraham Street (A2 & A3) 211 Ingraham Street (A4 & A5) Brooklyn NY Johnson Avenue Brooklyn NY THE1896.

SARASOTA WEST OF TRAIL WITH CLASSIC SOUTHERN STYLE

MULTIFAMILY PERFORMANCE PROGRAM Technical Topic New Buildings Savings Opportunity - Stairwell Lighting

HOUSES COMPANY PROFILE

COMPARISON OF SAMPLING METHODS FOR AIR TIGHTNESS

Selling by auction online: A guide for Sellers

Park View is a state-of-the-art development with a collection of 2 and 3-bedroom homes close to Manchester City Centre.

The City of Los Altos Building Square Footage Calculations Used for Determining Parking Requirements November 4, 2015 ATTACHMENT F

Ontario Municipal Board Decision issued June 19, 2014 and Order issued January 30, 2015 in Board File No. PL CITY OF TORONTO

CITY OF TORONTO BY-LAW NO. ~-20~

PROPERTY management. Case Studies

ANHALT RENOVATION + ADDITION Historic Preservation + Multifamily Residential Seattle, WA

HOUSING CODE CHECKLIST FOR RENTAL INSPECTIONS

COUNTY OF FREDERICK INSPECTIONS DEPARTMENT FEE SCHEDULE Approved July 14, COMMERCIAL FEES Minimum Fee $ unless stated otherwise

Commercial Real Estate Economic Impacts on Marin County, CA The Case of BioMarin s Expansion

Building Science Fundamentals Ventilation May 25-26, Joseph Lstiburek, Ph.D, P.Eng, ASHRAE Fellow. Adventures In Building Science

The Lakes Estate Serpentine Court Regeneration Group. 5 December 2017

Details of the Revised Business Improvement District Regulations

ATLANTA ZONING ORDINANCE UPDATE

169 CANAL STREET. 169 Canal Street VISION PROPERTIES 401 E. ELM STREET SUITE 150 CONSHOHOCKEN, PA Providence RI /20/2017

HC FINAL COST CERTIFICATION FORM AND INSTRUCTIONS

21 Longsdale Terrace Oban PA34 5JS Offers Over 128,000

3510 Plan Two Story Approx. 2,382 Sq. Ft. 3 Bedrooms 2.5 Baths Kitchen with Island Great Room Loft Covered Loggia 2 Bay Garage

*Figuring Square Footage

The Escrow Leaders MARKET UPDATE

The Impact of Balconies on Wind Induced Ventilation of Singlesided Naturally Ventilated Multi-storey Apartment

F, G, H, J, K, L, M Towers

REPORT ON BOYS SHELTER RENOVATION

RA2.01. Building Area: 89,222 SF. Cost per Square Foot: $162.22

Transferring Farm Machinery through a Lease Agreement Michael Langemeier, Associate Director, Center for Commercial Agriculture

ADDITION/REMODEL APPLICATION CHECKLIST 2017 FBC. Please make sure you have ALL required copies before submitting permit application

Pier47. An innovative, multiple user office building at the tip of Langelinie

Maratonvägen 36. Project summary. Energy concept: To achieve a substantial reduction of the energy losses.

CROSSWINDS AT HAWK S LANDING CONDO ASSOCIATION ANNUAL MEETING. October 24, :30 P.M. At the State Bank of Cross Plains in Verona, WI

Pier47. An innovative, multiple user office building at the tip of Langelinie

Target Market Variability. Parking & Outside

Toronto and East York Community Council Item TE6.1, as adopted by City of Toronto Council on June 10, 11 and 12, 2015 CITY OF TORONTO

Impacts of Maximum Allowable Building Footprint on Natural Ventilation in Apartment Building

TENANT DESIGN MANUAL UPDATED JULY 2015

Damascus

17 N Centre Ave Leesport, PA 19533

Home Selling Made Simple

BUILDING CODE COMMISSION

4 Camilla Court Earlsheaton, Dewsbury, WF12 8LR

Primer on MAUCRSA Co-Location Rules

KATE HIGHTSHOE. National Manager of the Year Contest. Photo Essay

4 Argyll Mansions 3 Argyll Street, Oban PA34 5SG Guide Price 150,000

The result of your calculations is the Net Operating Income, or monthly cash flow BEFORE any mortgage payments.

Section 9.5. Design of Areas, Spaces and Doorways

Juniper Avenue EH14 5EE

Gibson Street, Greenwich, London, SE10. winkworth.co.uk. See things differently. 465,000 Share of Freehold

The Forecaster Building Notice of Project Change

FRAMEWOOD ROAD FULMER SL2

THE INSIDE STORY EXTERIOR VARIETY PERSONALIZING OPPORTUNITIES KITCHENS TO SAVOR LUXURIOUS BATHS WATER AND ENERGY SAVERS

WATERFIX STRATA PROVIDES SAVINGS FOR CUSTOMERS IN HI-RISE TOWERS

Renovation Progress. May 5 11, Week 31

THE INSIDE STORY EXTERIOR VARIETY KITCHENS TO SAVOR PERSONALIZING OPPORTUNITIES LUXURIOUS BATHS WATER AND ENERGY SAVERS

SIMCOE STREET, RETAIL FOR LEASE SITE FEATURES AREA AMENITIES PROPERTY IMAGES SITE PLAN FLOOR PLANS DEMOGRAPHICS

Thames Penthouse Receives New Look

31 CALLUM CRESCENT KINGSWELLS AB15 8XQ

Gledhow Wood Road, Roundhay, Leeds, LS8 1PF

Demonstration Properties for the TAUREAN Residential Valuation System

Proudly Presenting. 933 Skeena Court

MADISON AVENUE FEATURES LEASING INFORMATION. 18-foot ceiling heights (slab-to-slab) New building construction

User Manual. Section 2: Implementation and Industry Translations. Created: October Copyright PropertyBoss Solutions, LLC. All Rights Reserved.

The Everbach Group - Realty Executives Associates - - Copyright 2018 All Rights Reserved

2.2 Future Demand Projection Methodology

Glen Lake Homeowners Association Clubhouse Reservation Form. Glen Lake Homeowner s Name: Glen Lake Homeowner s Address:

VIRGINIA CENTRAL REGION ITS ARCHITECTURE MAINTENANCE PLAN

OPERABLE ALL-GLASS BALCONY GLAZING SYSTEMS. NanaGlass SL25

Transcription:

Large Building Air Leakage Testing Page 1 of 7

Large Building Air Leakage Testing Although the test is relatively quick to perform, testing large building differs from testing residential houses in that but the building setup can easily take ten times longer. Additionally, the tester must understand the mechanical systems in order to ensure that they have been properly set up for the test. Learning how to use Retrotec's specialized door fan equipment is the easy part and takes a very small amount of time compared to understanding the dynamics of the buildings involved. Companies that normally do mechanical engineering jobs on large buildings are best suited for this type of test. Examples of testing costs for various sized buildings Enclosure area facing outdoors (ft 2 ) 32,000 64,000 128,000 192,000 Number of Buildings tested together 3 3 3 3 Number of floors 1 2 4 6 Number of door fans (Model 3000) 1 2 4 6 Staff used 2 2 2 2 Days of testing 2 3 4 4 Preparation prior to test $2100 $2400 $2475 $2550 Travel cost from out of town by air $7,600 $8,100 $8,600 $8,600 On site testing for leakage and infrared $4,650 $6,750 $8,400 $9,675 Reporting for leakage and infrared $5,175 $6,975 $6,975 $8,775 Door fan and IR equipment rental and shipping $1,500 $2,300 $3,910 $5,920 Total cost of test all inclusive $21,025 $26,525 $30,360 $35,520 Maximum envelope area that can be tested for various door fans Size of buildings to be tested is based on 0.25 CFM at 75 Pa/ft 2 (per square foot) of envelope area. Energy efficient buildings would be 0.1 CFM at 75 Pa/ft 2, good buildings would be 0.25, average buildings would be 0.5 and poor buildings would be 1.0. The figures in the table below can be scaled up or down for the expected leakage rate. Eg. If 0.5 CFM at 75 Pa/ft 2 is expected, divide all the areas by 2. Systems (See models:us3101 or US3121) 1 2 3 4 6 Open warehouse style buildings Enclosure area facing outdoors (ft 2 ) 32,000 64,000 96,000 128,000 192,000 Building footprint (ft 2 ) of one floor, 12 ft high 13,000 24,000 48,000 60,000 89,000 1 to 4 story buildings Enclosure area facing outdoors (ft 2 ) 32,000 64,000 96,000 128,000 192,000 Building footprint (ft 2 ) of one floor 13,200 28,000 43,000 58,200 89,000 Total floor area (ft 2 ) of all floors 52,800 112,000 172,000 232,800 356,000 High-Rise buildings - any height Enclosure area facing outdoors (ft 2 ) No No limit No limit No limit No limit Building footprint (ft 2 ) of one floor No 23,000 28,000 46,000 69,000 Total floor area (ft 2 ) of all floors No No limit No limit No limit No limit Page 2 of 7

Open warehouse style buildings This is the only style building where any number of fans can be put into one or more doorways. In other buildings with interior doorways there is a limit of 200 CFM per square foot of doorway opening which limits the maximum number of fans that can be used to access floors above. 1 to 4 story buildings open to outdoors The practical limit for this style of test is usually reached with two fans of 8000 CFM each. Assuming 1/3 of the leakage is out the ground floor then 6000 CFM per fan will reach the upper floors through the available doorways. Two 3' x 7' doorways to the stairs, provides 42 ft² of area, through which 12,000 CFM must flow. This will cause a pressure drop of about 2.7 Pa. still acceptably under the 5 Pa limit. Only if 4 doorways were available could 4 fans be used to test this building. High-Rise buildings High rise buildings with any number of floors can be tested as long as the building footprint area does not go above the limit specified in the table above. This test method has the added advantage in that leakage from each floor to the outdoors is measured as well as the leakage between floors. Leakage to the outdoors will affect the energy efficiency of the building as well as the indoor air quality and the amount of stack effect and wind effect in the building. The leakage between floors will affect the amount of pressure due to stack effect. If each floor in the high-rise is open to the outdoors, another testing option is to have one fan running on each floor. Page 3 of 7

Floor-at-a-time Testing Procedure with 2 door fans The fan on the 10th floor is measuring 1000 CFM which is the leakage from the 10th floor to outdoors plus the leakage to the floor below. When the 9th floor is pressurized to the same pressure as the 10th floor, leakage between the floors is neutralized. The 10th floor flow drops to 800 CFM, which is a measure of the leakage from the 10th floor to outdoors. The 200 CFM decrease in the 10th floor fan indicates that the leakage between the 10th and 9th floors is 200 CFM. The 10th floor fan is now moved to the 8th floor to neutralize the flow between the 8th and 9th floors. The fan on the 9th floor is now measuring leakage from the 9th floor to outdoors and to the floor above. Since it is known that the leakage to the floor above is 200 CFM, by subtraction the leakage from the 9th floor to outdoors must be 500-200 = 300 CFM. Now when the 8th floor fan is turned off, the flow on the 9th floor fan increases to 600 CFM. The increase of 100 CFM from the previous step indicates that the leakage between the eighth of the ninth floors is 100 CFM. By continuing this process down the building, the leakage of each floor to outdoors, and the leakage between each floor, can be quickly and easily measured. Page 4 of 7

Apartment testing on all sides with 2 door fans Leakage from all sides can be tested, with one system, by pressurizing a single apartment. Assume this apartment is on the 3rd floor of a four story apartment building. A second door fan is set up, sucking air out of the stairwell which is open to outdoors and into the hallway. Both fans are set to pressurize to the same set pressure of +50 Pa, and in automatic mode will balance themselves to achieve the same pressure. By pressuring the hallway to the same pressure as the apartment, the leakage across the hallway wall to the apartment is neutralized. The drop in flow rate, on the fan pressurizing the apartment, indicates how much the hallway wall is leaking. Next, the door is opened to the adjacent apartment. The hallway fan now neutralizes the flow across both the hallway wall, and the adjacent apartment wall. The change in flow, on the apartment fan, indicates the leakage across the adjacent apartment wall. Next, the door to the other apartment is opened, and the hallway fan now neutralizes the flow across the both apartment wall. The incremental drop in flow, from the previous test, measures the air leakage across the second apartment wall. The leakage of the three interior sides of the apartment has now been measured, plus the total leakage. Page 5 of 7

Apartment floor leakage measurement Leakage from the apartment on the previous page to the floor above is measured by establishing the same pressure on the floor above using another door fan. The drop in fan flow from the tested apartment is an indication of the leakage from the apartment to the floor above. The same test, with a door fan moved to the floor below, indicates the leakage through the floor below. Now the leakage of the apartment from five sides has been measured and the remaining leakage is the leakage from the apartment to outdoors. Page 6 of 7

Floor-at-a-time Testing Procedure with 3 door fans The fans on the top three floors are run simultaneously to establish the same pressure on each floor. The 10 th and 9 th floor door fans measure the leakage of their respective floors to outdoors directly, because the leakage of the 10 th and 9 th floor slabs is neutralized. The 8 th floor fan is now turned off and the measured flow on the 9 th floor fan goes up from 300 to 400 CFM. The increase of 100 CFM is the leakage between the 8 th and 9 th floors. The 9 th floor fan is now turned off and the measured flow on the 10 th floor fan goes up from 800 to 1000 CFM. The increase of 200 CFM is the leakage between the 9 th and 10 th floors. Fans from the 10 th and 9 th floors are moved to the 7 th and 6 th floors and the process is repeated all the way down the building. Using 3 fans to test a large building is significantly faster than using 2 fans. Page 7 of 7