Similar documents
FINAL SUBDIVISION AND LAND DEVELOPMENT PLAN CHECKLIST. Plan Name. Applicant's Name:

Date: 3/7/18 RFB No: Commodity: Wastewater System Improvements FY 16/17 Phase 12 Herring Sedwick Sewer Phase II.

City of Lawrence Design Criteria Section 5500 Sanitary Sewer (8 to 18 Mains)

DIVISION 2 - CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS

Phase 2A Lots and Parcel Identification Numbers: All located in Plat of Pleasant Hill Estates

DETAILED GRADING PLAN CHECKLIST (TEARDOWN/REDEVELOPMENT)

DETAILED GRADING PLAN CHECKLIST (TEARDOWN/REDEVELOPMENT) Updated: 12/12/2017

STAFF REPORT Administrative Subdivision Hearing West 150 South Street, Parcel # , and

Walmart Excess Land For Sale

PLAT OF SURVEY VICINITY MAP (NOT TO SCALE) N N W E SITE BENCHMARK # 2 W E N&D ON BACK OF CURB NAVD 88 S S 0' 10' 20' 40' 60' 1" = 20' TOP=106.7

PLANNING COMMISSION REPORT Regular Agenda Non-Public Hearing Item PRELIMINARY PLAT FOR JOHNSTON ADDITION; 706 E 23 RD ST (MKM)

HAMILTON COUNTY SECONDARY ROAD DEPARTMENT DRIVEWAY AND ENTRANCE POLICY EFFECTIVE NOVEMBER 28, 2017

ARTICLE 7 UTILITIES AND EASEMENTS

APPLICATION FOR ENDORSEMENT OF A PLAN BELIEVED NOT TO REQUIRE APPROVAL DETERMINATION THAT SUBDIVISION APPROVAL IS NEEDED

Airport Rd. Lot 6 Lot 2 Lot 1. 1 Mile: Population: 1,100 Median HH Income: $51, Mile: Population: 16,300 Median HH Income: $53,500

JEFFERSON COUNTY, ALABAMA

Appendix 4 Agency Approval Letters

DRIVEWAY/ACCESS PERMIT APPLICATION INSTRUCTIONS Douglas County Trunk Highways

Upper Bern Township PO Box North 5 th Street Shartlesville, PA Phone: Fax:

MAPLETON CITY CORPORATION. Step 7: Upon final approval and prior to plat recording the applicant shall provide the following:

ARTICLE 900 PLAT AND PLAN REQUIREMENTS

ENGINEERS & SURVEYORS INSTITUTE Peer Review Checklist FAIRFAX COUNTY. SITE/SUBDIVISION PLAN First Submission

Location Map Project: Olshansky Subdivision Applicant: David Olshansky Address: 16965, Cottage Grove Ave Project No a.

CITY OF MADISON HEIGHTS OAKLAND COUNTY, MICHIGAN. RESOLUTION regarding FEE SCHEDULE FOR COMMUNITY DEVELOPMENT DEPARTMENT SERVICES

City of Whittier Penn Street, Whittier, California (562) Fax (562)

REGULATIONS OF WALLER COUNTY, TEXAS

FENCES BUILDING PERMIT APPLICATION

1 Mile: Popula on: 9,400 Median HH Income: $65, Mile: Popula on: 113,000 Median HH Income: $59,600

CONSTRUCTION PLANS for HALCYON A RESIDENTIAL SUBDIVISION 6100 MIDNIGHT PASS ROAD, SARASOTA, FL 34242

MINNEHAHA COUNTY HIGHWAY DEPARTMENT HIGHWAY ACCESS APPLICATION & PERMIT

SECTION 4: PRELIMINARY PLAT

CITY OF CITRUS HEIGHTS Planning Department 6237 Fountain Square Drive Citrus Heights, CA (916)

AERIAL PHOTOGRAPH 2015:

February 18, Conformity of the PUD to Standards Prescribed in the Zoning Ordinance

The City Engineering Division has reviewed the subject development and has the following comments.

SECTION SITE SURVEYS

7. EASEMENTS Label Established Lines Affecting Tract and/or Mentioned in its Legal Description:

GENERAL CONDITIONS APPLYING TO SUBDIVISIONS APPROVED BY THE PLANNING BOARD OF THE TOWN OF BETHLEHEM ALBANY COUNTY - NEW YORK

Planning and Zoning Division Department of Community Development. Applicant: Ivory Towns LLC

Two Notch Road. 3 Mile: Popula on: 53,000 Median HH Income: $68, Mile: Popula on: 98,200 Median HH Income: $63,300

Towne Center Boulevard William Penn Highway. Lot 2. 1 Mile Population: 3,600 Median HH Income: $36,800

Condominium Unit Requirements.

April 10, 2017 WATER

February 11, The following Councilmembers were present: Brown, Dagg, Kajewski, Hahn and Sollom. Dagg chaired the meeting.

PLANNING BOARD APPLICATION FORM TOWNSHIP OF BETHLEHEM 405 MINE ROAD ASBURY, NEW JERSEY Date of Application: Township Application Number:

-

SUBDIVISION AND LAND DEVELOPMENT. 185 Attachment 20

PUBLIC HEARING* N/A. C I T Y O F T A C O M A Planning & Development Services Department 747 Market St, Rm 345 Tacoma, WA 98402

2018 APPLICATION AND PROCESS FOR OBTAINING WATER AND SEWER SERVICES

SUBDIVISION / RESUBDIVISION APPLICATION

Section 3.0: RESIDENTIAL AND NON-RESIDENTIAL SUBDIVISION APPLICATION AND APPROVAL PROCESS

PRELMINARY PLAT CHECKLIST

CERTIFIED SURVEY MAP

Approval of a conditional use to allow construction of a rehabilitation hospital at 5115 N. Biltmore Lane in the American Center.

Walmart Outparcel For Sale

ENGINEERING CODE FOR SUBDIVISION DEVELOPMENT OF MEDINA COUNTY, OHIO BOARD OF MEDINA COUNTY COMMISSIONERS

COMMUNITY DEVELOPMENT AND RESOURCES COMMISSION OF THE CITY OF ATWATER

RFQ INDEFINITE DELIVERIES CONTRACT - LAND SURVEYING SERVICES MAY

ORDINANCE NO

Preliminary Subdivision Application (Minor) (Three (3) lots or less)

Soojian Dr. Hwy 9 Lot 1. Main Street. 1 Mile Popula on: 1,000 Median HH Income: $75, Mile: Popula on: 11,900 Median HH Income: $61,500

Title: ENCROACHMENT POLICY Number: 0132 Reference: Administrative Committee January 21, Adopted by City Council: February 2, 2009

PLANNED UNIT DEVELOPMENT CITY OF CHAMBLEE, GA

ARTICLE 900 PLAT AND PLAN REQUIREMENTS

Preliminary Subdivision Application (Major) (Four (4) lots or more)

LYON COUNTY COMMUNITY DEVELOPMENT DEPARTMENT

RIVERDALE CITY PLANNING COMMISSION APPLICATION FOR RESIDENTIAL SUBDIVISION SITE PLAN APPROVAL

PLANNED UNIT DEVELOPMENT

Township of Collier 2418 Hilltop Road Presto, PA 15142

SPECIFICATIONS FOR NEW UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS

E L M E R B O R O U G H L A N D U S E B O A R D APPLICATION COVER SHEET (to be completed for all applications and appeals)

TRENCHING UNDERGROUND DISTRIBUTION ALL UNDERGROUND DISTRIBUTION DESIGNS ARE TO BE A CUSTOMER PROVIDED TOTAL CONDUIT SYSTEM INSTALLATION.

MTC ALABAMA SUBDIVISION

Chapter 4 Utility Locations and City Utility Easements

TILDEN TOWNSHIP PLANNING COMMISSION

RFP # Request for Proposals Canyon Pointe Parking Lot Replacement

A GUIDE TO PROCEDURES FOR: SUBDIVISIONS & CONDOMINIUM CONVERSION

PRELIMINARY SUBDIVISION AND LAND DEVELOPMENT PLAN CHECKLIST. Applicant's Name:

1 Mile: Population: 14,200 Median HH Income: $62, Mile: Population: 71,100 Median HH Income: $68,600

Subdivision of existing two lots into three lots.

Committed to Service. License Agreement Application Form

Proposed Encroachment over SA Water Easements

Walmart Outparcel For Sale

ARTICLE 13 CONDOMINIUM REGULATIONS

SUPPLEMENTAL INFORMATION MAP SHEET NOTES

Attached is a Clinton Township Zoning Permit Application and requirements for issuance of a permit.

CITY OF APPLETON, WI POLICY FOR SPECIAL ASSESSMENTS

CITY OF EAU CLAIRE, WISCONSIN. SPECIAL ASSESSMENT POLICY (Dated: November 8, 2016)

# 1 HOLDOVER Revised SUB CANAL SUBDIVISION

UPPER ALLEN TOWNSHIP PLANNING COMMISSION REGULAR MEETING August 27, :00 P.M.

CHAPTER 26 PLANNING AND ZONING ARTICLE VII. MOBILE HOMES AND RECREATIONAL VEHICLE (RV) PARKS. Recreational Vehicle (RV) Park Development Standards

Appendix A Orleans County Local Law Assessment

TWELVE OAKS GENERAL INFORMATION (BUILDINGS A, B, C, and D ONLY)

SUBDIVISION APPLICATION Department of Planning & Development P.O. Box 2128 Dothan, Alabama Office Facsimile

STANDARD REQUIREMENTS FOR ESTABLISHING A PRIVATE DRAIN AS A COUNTY DRAIN IN OAKLAND COUNTY COMMUNITIES

Industrial Road Cross Dock Subdivision Minor Subdivision Preliminary Plat PLNSUB South Industrial Road Hearing date: May 9, 2013

Department of Planning & Development Services

SOUTHERN INDUSTRIAL PARK SUBDIVISION, LOT A, RESUBDIVISION OF LOTS 7 & 8

ALTA/NSPS LAND TITLE SURVEY

Drainage Study. Report Description. Prepared for: City of Minnetonka Beach. Prepared by: Phillip Elkin, P.E. Darren Amundsen, P.E.

Transcription:

ORIGINATOR: CITY OF MADISON, STREETS DIVISION REV. DATE: PLOT NAME: PLOT SCALE: SHEET NO. U-3 PLAN AND PROFILE CITY OF MADISON 890 890 885 885 880 880 875 875 870 870 865 865 860 855 860 855 850 850 20+00 21+00 22+00 23+00 24+00 25+00 FILE NAME: M:\DESIGN\STREETS\DGN\53B2209\UTILITIES\RCP03002.DGN DATE: 10/1/2013 20' SANITARY SEWER EASEMENT *410'-8"PVC@0.40% 22+0023+00 21+00 183 24+00 MATCH LINE SAS #9 McALLEN'S WAY SAS #8 225 *178'-8"PVC@0.40% 20+00 20+00 25+00 STA 20+00 MATCH LINE STA 25+00 NOTE: PRIOR TO INSTALLATION OF ANY DEWATERING WELLS CONTRACTOR MUST NOTIFY DNR DISTRICT SOLID WASTE COORDINATOR DUE TO PROXIMITY OF LANDFILL. 25+00 MCALLEN 120 BUSINESS PARK PROJECT NO. 53B2209 MCALLEN'S WAY LOT 3 LOT 4 MCALLEN 120 BUSINESS PARK SAS #9 STA 20'MC"+36 RT 2' RIM=873.30 EI(E)=860.41 EI(N)=860.51 SAS #8 STA 22'MC"+15 RT 0' RIM=874.24 EI(E)=859.60 EI(W)=859.70 *PIPE SHALL CONFORM TO ASTM D3034 SDR 26 OR EQUIVALENT *PIPE SHALL CONFORM TO ASTM D3034 SDR 26 OR EQUIVALENT *115'-8" PVC@0.40% *178'-8"PVC@0.40% *410'-8"PVC@0.40% *115'-8" PVC@0.40%

ORIGINATOR: CITY OF MADISON, STREETS DIVISION PCC Sta = 83+67.77 REV. DATE: PLOT NAME: PLOT SCALE: 28+00 FILE NAME: M:\DESIGN\STREETS\DGN\53B2209\UTILITIES\RCP04002.DGN DATE: 10/1/2013 CONNECT TO EX STUB MATCH LINE STA 25+00 25+00 MCALLEN 120 BUSINESS PARK SHEET NO. PROJECT NO. 53B2209 U-4 PLAN AND PROFILE MCALLEN'S WAY & MEIER RD. CITY OF MADISON 880 880 875 875 870 EX SAS #7460-002 STA 83'MC"+98 RT 0' RIM=869.05 EI(S)=857.41 EI(N)=857.51 EI(W)=858.00 870 865 865 860 860 855 CONNECT TO EX STUB SANITARY SEWER INSTALLED UNDER PROJECT #53B2209 IN 2009 855 850 850 25+00 26+00 27+00 28+00 29+00 30+00 *410'-8"PVC @0.40% EX SAS #7460-003 STA 28'MC"+50 RT 0' RIM=875.82 EI(S)=858.39 EI(N)=858.49 EX 12" SAN EX 12" SAN *PIPE SHALL CONFORM TO ASTM D3034 SDR 26 OR EQUIVALENT EX SAS #7460-002 SAN 78 84+00 WETLAND BOUNDARY EX 12" SAN *410'-8" PVC@0.40% 112,790 SF O.L. 4 CONTRACTOR MUST NOTIFY DNR DISTRICT SOLID WASTE COORDINATOR DUE TO PROXIMITY OF LANDFILL. OHE NOTE: PRIOR TO INSTALLATION OF ANY DEWATERING WELLS EX 12" SAN 85+00 MEIER ROAD O.L. 4 EX SAS #7460-003 PT Sta = 25+60.19 26+0027+00 PC Sta = 26+63.42 12" WATER PT Sta = 29+26.42 PT Sta = 85+11.48 SAN 29+00 EX 12" SAN McALLEN'S WAY EOP Sta = 85+78.61 25+00 LOT 2 LOT 3

ORIGINATOR: CITY OF MADISON, STREETS DIVISION REV. DATE: PLOT NAME: PLOT SCALE: 225 FILE NAME: M:\DESIGN\STREETS\DGN\53B2209\UTILITIES\RCP01004.DGN DATE: 10/1/2013 N87 28'00"E N87 28'00"E 868 864.25 MATCH LINE STA 45+00 864.25 868 866 866 868 864 863 864 864.25 MCALLEN BUSINESS PARK PROJECT NO. 53B2209 PLAN AND PROFILE SHEET NO. U-5 SANITARY EASEMENT CITY OF MADISON 885 885 880 880 875 875 870 870 865 865 860 855 SAS #10 STA 19'MC"+19 RT 0' RIM=873.25 EI(S)=860.97 EI(N)=861.07 EI(W)=861.07 SAS #13 STA 43'E"+96 LT 10' RIM=869.00 EI(S)=862.67 EI(W)=862.77 860 855 850 850 845 845 40+00 41+00 42+00 43+00 44+00 45+00 *400'-8" PVC@0.40% 247'-8" PVC@0.40% *PIPE SHALL CONFORM TO ASTM D3034 SDR 26 OR EQUIVALENT PROPOSED LOT LINE GRADE PROPOSED LOT LINE GRADE 18+00 McALLEN'S WAY 186 LOT 3- MCALLEN 120 BUSINESS PARK *93'-8"PVC@0.40% SANITARY EASEMENT STA 40+50 TO STA 44+00 SEWER ACCESS ROAD SHALL BE BUILT IN ACCORDANCE WITH CITY OF MADISON STANDARD DETAIL DRAWING 5.1.4. 623.60' EASEMENT 1 POB N = 473730.73 E = 851894.46 41+00 42+00 43+00 44+00 45+00 85 19+00 SAS #13 *400'-8"PVC@0.40% 247'-8"PVC@0.40% 143 BOP Sta = 40+00.00 EASEMENT 1 SAS #10 20' SANITARY SEWER EASEMENT S-2 P-25 S-25 P-26 *115'-8"PVC@0.40% S-1 P-1 P-2 S-0 SAN EASEMENT ALIGNMENT DATA 20+00 O.L. 2 X EX. WETLAND EDGE 863.95

ORIGINATOR: CITY OF MADISON, STREETS DIVISION REV. DATE: PLOT NAME: PLOT SCALE: FILE NAME: M:\DESIGN\STREETS\DGN\53B2209\UTILITIES\RCP02004.DGN DATE: 10/1/2013 870 866 S-50 P-51 S-54 S-51 P-54 20' 862 860 858 856 SHEET NO. PROJECT NO. 53B2209 PLAN AND PROFILE CITY OF MADISON 885 885 880 880 875 875 870 870 865 865 860 860 855 855 850 850 845 845 45+00 46+00 47+00 48+00 49+00 50+00 247'-8" PVC@0.40% 71+00 MATCH LINESTA 45+00 45+00 46+00 SAS #14 8" STUB 14'-8"PVC@0.40% N 00 29'31" E 962.26 FT EOP Sta = 46+87.52 POB N = 473647.32 E = 851241.97 247'-8"PVC@0.40% 20' SANITARY SEWER EASEMENT BOP Sta = 70+00.00 BOP Sta = 70+00.00 MCALLEN 120 BUSINESS PARK U-6 SANITARY EASEMENT S-51 PROPOSED LOT LINE GRADE P-54 8" STUB 14'-8"PVC@0.40% PLACE MARKER BALL SAS #14 STA 46'E"+44 LT 9' RIM=871.00 EI(S)=863.76 EI(W)=863.86 STORM SEWER ALIGNMENT DATA POND

ORIGINATOR: CITY OF MADISON, STREETS DIVISION REV. DATE: PLOT NAME: PLOT SCALE: FILE NAME: M:\DESIGN\STREETS\DGN\53B2209\UTILITIES\RCP03001.DGN DATE: 10/1/2013 GRAVEL MCALLEN 120 BUSINESS PARK FEMRITE DR PROJECT NO. 53B2209 PLAN AND PROFILE SHEET NO. U-7 CITY OF MADISON 895 895 890 890 885 885 880 880 875 875 870 870 865 865 860 860 855 855 52+00 53+00 54+00 55+00 56+00 57+00 45'-15" RCP@1.78% LOT 2 S-35 P-36 S-36 52+00 53+00 54+00 55+00 56+00 57+00 FEMRITE DRIVE 34+00 35+00 36+00 FEMRITE DRIVE LOT 2 MCALLEN 120 BUSINESS PARK

SANITARY SEWER SCHEDULE ALIGNMENT CODES: "M"=MCALLEN'S WAY "E"=SANITARY SEWER EASEMENT MCALLEN BUSINESS PARK PROJECT NO. 53B2209 SHEET NO. U-8 PROPOSED SANITARY STRUCTURES PROPOSED SANITARY PIPES SANITARY SEWER SCHEDULE SAS STATION LOCATION TOP OF E.I. DEPTH NOTES FROM SAS TO SAS LGTH E.I. E.I. SLOPE SIZE TYPE NOTES NO. (OFFSET) CASTING (DNSTM) (UPSTM) (FT) DOWNSTREAM UPSTREAM (%) (DIA) CITY OF MADISON REV. DATE: _ PLOT NAME: _ PLOT SCALE: _ SAS #8 22'M'+15.00 RT-0' 874.24 859.60 14.64 7460-002 SAS #8 410 858.00 859.60 0.40% 8'' PVC SDR 26 SAS #9 20'M'+36.00 RT-2.00 873.30 860.41 12.89 SAS #8 SAS #9 178 859.70 860.41 0.40% 8'' PVC SDR 26 SAS #10 19'M'+19.00 RT-0' 873.25 860.97 12.28 SAS #9 SAS #10 115 860.51 860.97 0.40% 8'' PVC SDR 26 SAS #11 18'M'+25.00 RT-0' 873.72 861.44 12.28 SAS #10 SAS #11 93 861.07 861.44 0.40% 8'' PVC SDR 26 SAS #12 14'M'+75.00 RT-0' 875.47 862.94 12.53 SAS #11 SAS #12 350 861.54 862.94 0.40% 8'' PVC SDR 26 SAS #13 43'E'+96.00 LT-10.00 869.00 862.67 6.33 SAS #10 SAS #13 400 861.07 862.67 0.40% 8'' PVC SDR 26 SAS #14 46'E'+44.00 LT-9.00 871.00 863.76 7.24 SAS #13 SAS #14 247 862.77 863.76 0.40% 8'' PVC SDR 35 SAS #14 STUB 14 863.86 863.92 0.40% 8'' PVC SDR 35. ORIGINATOR: CITY OF MADISON STREETS DIVISION FILE NAME: M:\DESIGN\STREETS\DGN\53B2209\UTILITIES\SAN SCHEDULE MCALLEN.XLS DATE: 09/30/2013 SCALE: NTS

ALIGNMENT CODES: * REVISED 10-14-13 CCS MCALLEN 120 BUSINESS PARK SHEET NO. STORM SEWER SCHEDULE "MC"=MCALLEN WAY "ME"=MEIER RD ** REVISED 6-17-15 CCS PROJECT NO. 532209 U-9 "F"=FEMRITE DR "E"= SANITARY EASEMENT STORM SEWER SCHEDULE CITY OF MADISON STRUCTURES "ES"= STORM EASEMENT PIPES STRUC. STATION LOCATION TYPE TOP OF E.I. DEPTH NOTES PIPE FROM TO LGTH DISCH. INLET SLOPE PIPE TYPE NOTES NO. (OFFSET) CASTING NO. (DNSTM) (UPSTM) (FT) E.I. E.I. (%) SIZE PLOT SCALE: _ PLOT NAME: _ S-0 19'MC'+28.00 RT-87.00 48" APRON END --- 864.25 --- W/GATE P-1 S-0 S-1 88 864.25 864.69 0.50% 48'' RCP S-1 19'MC'+68.00 RT-17.50 5X5 SAS 873.06 864.69 8.37 LP; W/3067-7004 P-2 S-1 S-2 35 864.69 864.87 0.51% 48'' RCP S-2 19'MC'+68.00 LT-17.50 5X5 SAS 873.06 864.87 8.19 LP; W/3067-7004; (5) P-25 S-2 S-25 80 867.26 868.00 0.93% 30'' RCP NCM ** S-25 18'MC'+75.00 LT-17.50 4X4 SAS 873.53 868.00 5.53 W/DW CASTING P-26 S-33 S-26 241 868.54 869.74 0.50% 30'' RCP S-26 15'MC'+25.00 LT-17.50 4X4 SAS 875.28 869.74 5.54 LP; FP; W/3067-7004; (1) P-27 S-26 S-27 200 870.24 873.00 1.38% 24'' RCP * S-27 13'MC'+25.00 LT-17.50 3X3 SAS 877.90 873.00 4.90 W/3067-7004-V; (4) P-29 S-26 S-29 35 870.74 871.00 0.74% 18'' RCP NCM * S-29 15'MC'+25.00 RT-17.50 H INLET 875.28 871.00 4.28 LP; W/3067-7004 P-30 S-27 S-30 35 873.00 873.50 1.43% 18'' RCP S-30 13'MC'+25.00 RT-17.50 H INLET 877.90 873.50 4.40 W/3067-7004-V P-31 S-27 S-31 252 873.25 880.50 2.88% 21'' RCP S-31 10'MC'+70.00 LT-17.50 3X3 SAS 884.66 880.50 4.16 W/3067-7004-V P-32 S-31 S-32 69 880.50 884.40 5.65% 18'' RCP * S-32 10'MC'+36.00 RT-43.00 18" AE --- 884.40 --- P-33 S-25 S-33 107 868.00 868.54 0.50% 30'' RCP ** S-33 17'MC'+65.00 LT-17.50 4X4 SAS 873.56 868.54 5.02 W/3067-7004-V P-34 S-33 S-34 35 870.14 870.40 0.74% 12'' RCP NCM ** S-34 17'MC'+65.00 RT-17.50 H INLET 873.56 870.40 3.16 W/3067-7004-V S-35 52'MC'+21.00 RT-35.00 15" RCP AE --- 881.03 --- END OF APRON STATIONED P-36 S-36 S-35 45 880.23 881.03 1.78% 15'' RCP S-36 52'MC'+67.00 RT-35.00 15" RCP AE --- 880.23 --- END OF APRON STATIONED P-51 S-50 S-51 29 863.25 865.26 6.93% 24'' STORM PIPE S-50 70'ES'+31.00 RT-29.00 24" RCP AE --- 863.25 --- W/GATE; (3) S-51 70'ES'+37.00 RT-0 4X4 SAS 871.75 865.26 6.49 W/R-1550-0054 P-54 S-51 S-54 16 865.26 865.32 0.40% 24'' STORM PIPE S-54 46'E'+52.50 LT-1.00 PIPE PLUG --- 865.32 --- PLACE MARKER BALL REV. DATE: _ ORIGINATOR: CITY OF MADISON STREETS DIVISION STANDARD NOTES: - ABBREVIATIONS: AE = APRON ENDWALL; RCP = REINFORCED CONCRETE PIPE; HERCP = HORIZONTAL ELLIPTICAL REINFORCED CONCRETE PIPE; DNA = DOES NOT APPLY; SAS = SEWER ACCESS STRUCTURE; LP = LOW POINT INLET STRUCTURE; FP = FIELD POURED STRUCTURE; TR = TOP OF CONCRETE ROOF; NCM = NO CROWN MATCH FOR PIPES - APPROXIMATE DISCHARGE E.I. GIVEN, ADJUST E.I. AND PIPE SLOPE IN THE FIELD. - TOP OF CASTING GRADE GIVEN IS THE TOP OF CURB FOR INLET STRUCTURES AND THE FLOWLINE OF THE CLOSED CASTING FOR SAS's. SPECIFIC NOTES - TOP OF CONCRETE ROOF (TR) IS 1.25' BELOW TOP OF CASTING UNLESS OTHERWISE NOTED. (1) PROVIDE 15" PVT STM EI=870.99 - ALL REINFORCED CONCRETE PIPES TO BE CLASS III UNLESS OTHERWISE NOTED. (2) PROVIDE BOX OUT FOR 18" RCP @ EI=868.50 - SURVEYOR TO CONFIRM THAT ALL INLET STATION / OFFSETS LINE UP WITH PROPOSED CURB AND GUTTER. (3) CONCRETE COLLAR REQUIRED FOR CONNECTION OF PLASTIC PIPE TO RCP AE - ALL STRUCTURES CALLED OUT AS FIELD POURED SHALL BE FIELD POURED. ALL OTHER STRUCTURES (NOT INDICATED AS FIELD (4) PROVIDE 15" PVT STM EI=873.00 POURED) SHALL BE SUBMITTED TO CITY ENGINEERING FOR APPROVAL IF PRECAST STRUCTURES ARE PREFERRED. CONTACT (5) PROVIDE BOX OUT FOR FUTURE 36" RCP TO EAST COREY STELLLJES OF CITY ENGINEERING AT (608) 266-9721 FOR PRECAST APPROVALS, OR FAX SHOP DRAWINGS TO (608)264-9275. FILE NAME: M:\DESIGN\STREETS\DGN\53B2209\UTILITIES 2013\STORM SCHEDULE MCALLEN.X DATE: 06/17/2015

SL1311_McAllen_V8.dgn 9/30/2013 11:47:25 AM