400-450 Palm Ave Hialeah Building Data Address 400-450 Palm Avenue City, State Hialeah, Florida County Miami Dade parcel # 04-3118-001-1950 and 1960 Zoning Retail Commercial - BU2 Land Size 13500 Type Construction / Parking CBS - 6 parking Spaces Building Size 9067 Year Built Built 1951 renovated 2006 Tenant/Lease Data Rent Square feet term Tenant 1-400 Palm Av Cuba Pack Envio $ 31,710 2265 14 Tenant 3-410 Palm Ave Liberty Tax $ 15,000 1000 15 Tenant 4-420 Palm Ave Argenty Bakery $ 19,200 1584 $ 12 2.28.2018 Tenant 5-436 Palm Ave Pichardo $ 11,616 1056 $ 11 mo-mo Tenant 6-444 Palm Ave Jose Martinez Clothing $ 32,400 2644 $ 12 6.30.2017 Tenant 7-456 Palm Ave Jose Martinez Clothing in above 6.30.2017 $ 109,926 8549 EXPENSES: Cash Flow $ 109,926 Taxes paid by tenant $ 12,700 Insurance paid by tenant $ 8,970 maint & reserves paid by tenant $ 6,111 Net Cash Flow $ 91,320 6 cap $1,522,000 price / sf $191.88 rent / sf $ 12.12 $ Aug 31 2017 $ Apr 30 2018
2012 Google
450 palm ave - Google Maps 4/17/12 1:57 PM To see all the details that are visible on the screen, use the "Print" link next to the map. http://maps.google.com/maps?client=safari&rls=en&oe=utf-8&q=450 qtocw&sa=x&oi=geocode_result&ct=title&resnum=1&ved=0ccmq8gewaa Page 1 of 1
LEGEND = Arc = Asphalt = Bench Mark = Bearing = Catch basin = Catch basin = Concrete Block Structure = Chord A ASPH BM BRG CATV CB CBS CH Chatta.= Chattahoochee C L = Center Line CLF = Chain Link Fence CL. = Clear CONC.= Concrete D = Delta = Diameter DH = Drill Hole DME = Drainage & Maintenance Easement E.B. = Electric Box Enc. = Encroachment F.F. = Finish Floor F.H. = Fire Hydrant F.I.R. = Found Iron Rebar FPL = Florida Power & Light F.I.P. = Found Iron Pipe FD. = Found L.P. = Light Pole M = Measured M.F. = Metal Fence M.H. = Manhole M L = Monument Line MON. = Monument N/A = Not Applicable N/D = Nail & Disc NOTE: a) All clearances and/or encroachments shown hereon are of the apparent physical use, fence legal ownership not determined. b) The issue of this survey is only for the exclusive and specific use of those persons, parties or institutions in the certification. c) Code restrictions and title search not reflected in this survey d) Underground utilities, improvements, footings and encroachments, if any not located. e) The flood information shown hereon does not imply that the subject property will or will not be free from flooding or damage and does not create liability on the part of the firm or employee thereof, for any damage that occurs from reliance on said information. f) Lands depicted hereon were surveyed per legal description provided by client and no claims as to ownership or matters of title are made or implied. g) All roads shown hereon are public unless otherwise noted. h) No identification cap found on property corners unless otherwise noted. i) Distance along boundary are record and measured unless otherwise noted. j) The graphic portions of this document are intended to be displayed at the graphic/name scales as depicted. Said scale may be altered in reproductions and as such, should be considered when obtaining scaled data. k) Accuracy: The expected use of land as classified in the minimum technical standards (5J17-FAC), is "Suburban". The Minimum relative distance accuracy for the type of boundary survey is 1 foot in 7,500 feet. The accuracy obtained by measurement and calculation of a closed geometric figure was found to exceed this requirement. l) Contact the appropriate authorities prior to any design work or excavation on the herein described parcel for building, zoning information and utilities location. ADJACENT BUILDING 100.00' NTS = Not to Scale O/S = Offset O.U.L. = Overhead Utility Lines OH = Overhang P = Plat PB = Plat Book PC = Point of Curvature P.C.C. = Point of Compound Curvature PCP = Permanent Control Point PG = Page P.I. = Point of Intersection PL = Property Line PL = Planter P.O.B. = Point of Beginning P.O.C. = Point of Commencement P.P. = Power Pole P.R.M. = Permanent Reference Monument P.R.C. = Point of Reverse Curvature PT = Point of Tangency R = Radius R/R = Railroad PSM = Professional Surveyor Mapper E. 5th STREET 100.00' ONE STORY COMMERCIAL BUILDING # 400-450 This property described as: Lot 13 and 14, Block 15, TOWN OF HIALEAH, according to the Plat thereof as recorded in Plat Book 5, Page 77, of the Public Records of Miami-Dade County, Florida. Certified to: Lease Florida Hialeah LLC = Right-of-Way = Sidewalk R/W SWK = Section = Typical Sec. (TYP) = Tangent T Address: 400 Palm Avenue, Hialeah, FL 33010 = Utility Easement = Wood Fence = Water Meter = Water Valve U.E. W.F. W.M. W.V. X.XX Elevations shown refer to N.G.V.D. 1929. BM # M-74 (Miami-Dade County) Elevation = 9.41 ft (N.G.V.D.) PALM AVENUE = Denotes Spot Elevations Taken N/A (reference) N/A Bearing, if any, shown based on Alvarez, Aiguesvives and Associates, Inc. TOPOGRAPHIC SURVEY. I HEREBY CERTIFY: that this survey meets the standards of practice as set forth by the FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS in chapter 5J-17 Florida Administrative Code, pursuant to Section 472.027 Florida Statutes. REVISIONS: Surveyors, Mappers and Land Planners 5701 S.W. 107th Avenue #204, Miami, FL 33173 Phone 305.220.2424 Fax 305.552.8181 L.B. No. 6867 / E-mail: aaasurvey@aol.com Not valid unless it bears the signature and the original raised seal of Florida licensed Surveyor and Mapper. FLOOD ZONE COMM. No. PANEL No. SUFFIX: 0283 L AH 120643 Field Date Scale: Drawn by: Drwg. No. 03/15/16 1"= 20' R.S. 16-18238 RENE AIGUESVIVES 03/22/16 PROFESSIONAL SURVEYOR AND MAPPER No. 4327. State of Florida. BASE ELEV. F.I.R.M.INDEX F.I.R.M.DATE "THIS SURVEY DECLARATION IS MADE ON THE FIELD DATE INDICATED, TO THE OWNER(S) LISTED. IT IS NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS." + 8 FT N.G.V.D. 09 / 11 / 09 09 / 11 / 09 W 4th STREET