(AHA) ADA / UFAS SITE COMPLIANCE STUDY VERANDA ROAD NE 87111 PROJECT LOCATION ZONE LOCATION MAP G-20-Z O W N E R 1840 UNIVERSITY BLVD. SE ALBUQUERQUE, NM 87106 TEL: 505.764.3925 E N G I N E E R PROJECT DESCRIPTION EVALUATION STUDY TO DETERMINE THE OVERALL COMPLIANCE FOR THE SITE AND GENERAL HOUSING PERTAINING TO COMPLIANCE WITH ADA AND UFAS REQUIREMENTS. INDEX OF DRAWINGS G-001 COVER SHEET G-002 GENERAL NOTES C-101 IMPROVEMENT PLAN C-102 C-501 DETAILS CANDELARIA RD VERANDA RD MOON ST PARSIFAL ST COMANCHE RD EUBANK BLVD LOCATION MAP AND SHEET INDEX G-001
NOTE: CODE INFORMATION IS D FOR INFORMATIONAL AND GUIDELINE PURPOSES ONLY. DWELLING UNIT REMODELING AND SITE CIVIL WORK THAT REQUIRES PERMITTING AND CONSTRUCTION DOCUMENTS SHALL BE STAMPED BY A REGISTERED PROFESSIONAL ARCHITECT AND A REGISTERED PROFESSIONAL ENGINEER RESPECTIVELY. C O D E R E V I E W REFERENCE CODES - INTERNATIONAL BUILDING CODE - 2009 ICC / ANSI A117.1-2009 - UNIFORM FEDERAL STANDARDS - ADA 2010 INTERNATIONAL BUILDING CODE 2009 CHAPTER 11 SECTION 1101 SECTION 1104.1 SECTION 1104.2 SECTION 1104.3 SECTION 1105 SECTION 1106 SECTION 1107 SECTION 1107.6.2.1 S W/IN THE SITE SHALL BE D FROM PUBLIC TRANSPORTATION, PARKING, PUBLIC STREETS AND SIDEWALKS TO THE BLDG ENTRANCE. AT LEAST ONE SHALL CONNECT BLDGS, FACILITIES, AND ELEMENTS AN SHALL BE D TO EACH PORTION OF THE BLDG. ENTRANCES, WALKWAYS AND PUBLIC WAY. PUBLIC ENTRANCES. AT LEAST 60%%% OF ALL PUBLIC ENTRANCES SHALL BE. PARKING 4 MIN. REQ'D SPACES 76-100 DWELLING UNITS ADA STANDARDS FOR DESIGN 2010 SECTION 233 SECTION 233.3.4.2 SECTION 233.3.1.1 SECTION 233.3.1.2 GROUP R-2 TYPE A AND B UNITS SHALL BE D IN APARTMENTS RESIDENTIAL DWELLING UNITS IN INDIVIDUAL RESIDENTIAL DWELLING UNITS, WHERE A BATHROOM OR A KITCHEN IS SUBSTANTIALLY ALTERED, AND AT LEAST ONE OTHER ROOM IS ALTERED, THE REQUIREMENTS OF 233.3.1 SHALL APPLY TO THE ALTERED RESIDENTIAL DWELLING UNITS UNTIL THE TOTAL NUMBER OF RESIDENTIAL DWELLING UNITS COMPLIES WITH THE MINIMUM NUMBER REQUIRED BY 233.3.1.1 AND 233.3.1.2. RESIDENTIAL DWELLING UNITS REQUIRED TO COMPLY WITH 233.3.1.1 SHALL BE ON AN AS REQUIRED BY 206. RESIDENTIAL DWELLING UNITS WITH MOBILITY FEATURES. IN FACILITIES WITH RESIDENTIAL DWELLING UNITS, AT LEAST 5 PERCENT, BUT NO FEWER THAN ONE UNIT, OF THE TOTAL NUMBER OF RESIDENTIAL DWELLING UNITS SHALL MOBILITY FEATURES COMPLYING WITH 809.2 THROUGH 809.4 AND SHALL BE ON AN AS REQUIRED BY 206 IN FACILITIES WITH RESIDENTIAL DWELLING UNITS, AT LEAST 2 PERCENT, BUT NO FEWER THAN ONE UNIT, OF THE TOTAL NUMBER OF RESIDENTIAL DWELLING UNITS SHALL COMMUNICATION FEATURES COMPLYING WITH 809.5. GENERAL NOTES G-002
EX. WALK 47" UNIT 33 UNIT 35 31 35 2% MAX. INSTALL CROSS WALK STRIPES RAMP & CROSS WALK REPLACE WALK AS NEEDED TO CONSISTENT 2% MAX. CROSS SLOPE AND 5% MAX. LONGITUDINAL SLOPE FOR ACCESS TO MOON STREET NE ACCESS TO IMPROVEMENT PLAN 1 IMPROVEMENT PLAN C-101 REPLACE WALK AS NEEDED TO CONSISTENT SLOPE & 2% MAX. CROSS SLOPE - FILL DIRT, BOTH SIDES OF WALK TO PREVENT SHARP DROP-OFF AT EDGES FILL DIRT BETWEEN WALK & BACK OF CURB OR ADJACENT GROUND MAILBOXES & ACCESS REPLACE WALK AS NEEDED TO CONSISTENT SLOPE & 2% MAX. CROSS SLOPE CONSTRUCT RAMP BOTH SIDES OF VERANDA RD. PER DETAIL 1/C-501 REPLACE SECTIONS OF SIDEWALK AS NEEDED TO MAINTAIN CONSISTENT 2% CROSS SLOPE VERANDA ROAD NE INSTALL CROSS WALK STRIPES ACCESS TO MAILBOX CONSTRUCT RAMP BOTH SIDES OF VERANDA RD. PER DETAIL 1/C-501 5' MIN. 33 CONSISTENT 2% MAX. CROSS SLOPE AND 5% MAX. LONGITUDINAL SLOPE FOR ACCESS TO REV. NO. REV. DATE UNIT 31 EXTEND CONCRETE INTO PLANTING AREA AS NEEDED TO ACCESS TO NEW RAMP EX. 42.5" DESCRIPTION EX. 43" EX. 46" tele: 505.255.7802 www.abqeng.com
1 Scale: 1" 20' 31 33 35 MOON STREET NE C-102
1 6'-0" 3'-0" MIN. SIDEWALK RAMP 6'-0" Scale: NTS 8' (8" CURB HT.) 2 ENTRANCE LANDING REQUIREMENTS 42 min** 60 min 1525 48 min 1220 18 min 445 12 min* 305 (a) Front Approach, Pull Side 36 min 915 60 min 1525 42 min (c) Hinge Approach, Pull Side (d) Hinge Approach, Pull Side 22 min 560 24 min 610 (f) Latch Approach, Pull Side 24 min 610 42 min* 48 min* 1220 54 min 1370 Chapter 4. Accessibility Routes ICC/ANSI A117.1-2003 *If both closer and latch are provided (b) Front Approach, *If both closer and latch are provided **48" min (1220) if both closer and latch provided 12 min* 305 *54" min (1370) if closer is provided (e) Hinge Approach, (g) Latch Approach, *48" min (1220) if closer is provided Fig.404.2.3.1 Maneuvering Clearance at Manual Swinging Doors N.T.S. DETAILS C-501