Accessible Housing Standards 2015

Similar documents
q/., S Lt _ _.._--.

Access to and use of buildings

Meeting Part M and designing Lifetime Homes

Understanding Accessibility Features to Meet Housing Needs

Understanding Accessibility Features to Meet Housing Needs

ADAPTATIONS POLICY 2012

National Trust Cottages Access Statement

Abbey House, 56 Rother Street, Stratford-upon-Avon, CV37 6LT

National Trust Cottages Access Statement/Guide

National Trust Cottages Access Statement Cottage Ref The Farmhouse Middlebere Farm Arne Isle of Purbeck

Facilities providing accommodation for the public (e.g. Hotels, hostels, guesthouses, self catering apartments).

National Trust Cottages Access Statement

Residential Accessible, Type A, and Type B Dwelling Unit Requirements 2012 International Building Code and 2009 ICC/ANSI A117.1

National Trust Cottages Access Statement

Equality and Access Plan The Abbey School, Reading

Arlington County. Smart Choice Homes. Arlington County. Homes for all of us. Homes for a lifetime. Home

DESIGN, ACCESS & PLANNING STATEMENT

National Trust Cottages Access Statement

National Trust Cottages Access Statement Template

Give the name and distance of the nearest railway station. Describe the type of surface from the car park to the main entrance.

National Trust Cottages Access Statement

Proposed development at 131 Lyham Road, Lambeth London SW2 5PY

National Trust Cottages Access Statement

Spacious 4 Bedroom Detached Family Home

YHA Oxford Access Statement

DUNFIELD HOUSE & STABLES ACCESS STATEMENT

Wheelchair homes design guidelines. Guidelines to achieve the necessary standards for wheelchair users dwellings

Give the name and distance of the nearest railway station. Describe the floor surface e.g. tile/wood/rugs/carpet (thick/short pile).

BARTON FLEMING INDEPENDENT ESTATE AGENTS. 4 Springfield Road, Caversfield, Bicester, Oxfordshire. OX27 8TT

National Trust Cottages Access Statement

Access Statement for New England - Tregrill Farm Cottages

ACCESS STATEMENT FOR THE HEMMEL

Ffordd Draenen Ddu, West Cross, Swansea

Ivy Rose Cottage, Cruckmore Lane, Prees Green, Whitchurch, Shropshire, SY13 2BS

National Trust Cottages Access Statement

2018 CSBC / 2018 CSFSC Part III. Chapter #10. Means of Egress. Table of Contents. Based on the 2015 IBC and the 2015 IFC.

AVIS ESTATES Property Sales, Land, Developments & Country Homes. Woodlands Avenue. E m e r s o n P a r k, H o r n c h u r c h

ACCESS STATEMENT FOR the Byre AT BIRLING NORTH COTTAGE. Pre-Arrival. Parking. the East Coast Main Line is approximately 4km to the north.

Access Statement for FLAMBOROUGH ROCK COTTAGES

2014 OSSC CHAPTER 10 - MEANS OF EGRESS TABLE OF CONTENTS

National Trust Cottages Access Statement

Affordable Rental Housing Design Guidelines

Herne Bay. West Hill Road, Herne Bay, Kent, CT6 8HG 389,995

THE PALMS. Main Road, Whiteley Bank, Isle of Wight

National Trust Cottages Access Statement

Accessibility Guide for Buttermere Cottage

THIS CHECKLIST HAS BEEN AMENDED TO INCLUDE ONLY LEVEL ONE CRITERIA AS REQUESTED BY TIR REAL PROPERTY. As such it does not form a complete Checklist.

DEPARTMENT OF DEVELOPMENT SERVICES ACCESSIBILITY CHECK LIST FOR MULTI-FAMILY RESIDENTIAL BUILDINGS

Holly Bush Farm & Cottages Pikehall Matlock Derbyshire

Arriving and Getting In

TO LET UNFURNISHED MODERN DETACHED HOUSE

Access Statement Seaton 22 St Aidan s Seahouses NE68 7SS

College Hill Sutton Coldfield

Property. Introduction

3 Bedroom Semi-Detached for Sale - 169,950

BRYHER, 32 THE GLUYAS, FALMOUTH, TR11 4SE

London Accessible Housing Register A good practice guide for social housing landlords

BARTON FLEMING INDEPENDENT ESTATE AGENTS. 22 Sherwood Close, Launton, Bicester, Oxfordshire. OX26 5DR

Glyn Avenue Acton 425,000

Accessible Facilities Report Template

Austerlands, Manchester Road, Marsden, Huddersfield

National Trust Cottages Access Statement Template

Accessible Housing by Design. CMHC Research & Information Transfer. Jamie Shipley C.E.T. Canada Mortgage and Housing Corporation

National Trust Cottages Access

National Trust Cottages Access Statement Template

107 BURNHAM ROAD, HIGHBRIDGE, SOMERSET TA9 3EF

ASHENDEN, 5 LAMBOURNE WAY, THRUXTON, ANDOVER SP11 8NE OFFERS INVITED AROUND 425,000 FOR THE FREEHOLD

Property. Introduction

5 Standroyd Road, Colne, Lancashire, BB8 7BE

Max Gate Access Statement

Apartment , Ver A

Accessibility Guide. We look forward to welcoming you.

Parking. Access Statement Summerhouse Cottage Beadnell. Pre Arrival. Chathill-3.5 miles/ Alnmouth-15 miles/ Berwick upon Tweed-25 miles

Access Statement Henderson House 19 Henderson Street Amble NE65 0AE

Ribchester Road, Clayton Le Dale

20 Regent Court, Oswestry, SY11 2BU

4 Coldwell Lane Sandygate Sheffield S10 5TL.

Access Statement The Hollies Ingram Road Bamburgh NE69 7BT

THE OLD FOLDYARD 35 WESTGATE, OLD MALTON

Access Statement for Lorne House Bed & Breakfast

Sanders&Sanders ESTATE AGENTS

51 Taylor Street, Forfar, DD8 3LP

National Trust Cottages Access Statement

11 Farthing Combe, Axbridge, Somerset BS26 2DR 365,000

Chantry, Braintree Road, Felsted

General Information. Location Information. Location Use. Colorado VSPC/Drop-off/Drop-box Accessibility Survey Form. For SOS office use only

Swindon Road, Highworth, SN6 7DE 575,000. (Subject to Contract)

AVIS ESTATES G i d e a A v e n u e G i d e a P a r k

45 Woodfield Road OADBY, LEICESTER. Sales Lettings Surveys Mortgages

National Trust Cottages Access Statement

The hamlet at Tetley. Lakeside. North Lincolnshire. The Hamlet At Tetley 1

Give the name and distance of the nearest railway station. Describe the streets in the area surrounding the property

MaRsh & MaRsh properties

Access Statement Cinnamere Cottage, Eastgate, Pickering

10 Hardacre Lane, Shaw Hill, Whittle-le-Woods, Chorley Price guide 625,000

865,000. Westbrook. Through the wrought iron gates you are greeted by a large sweeping in and out driveway providing extensive off road parking.

Apartment 8, Wellingtonia House Hellyer Close, Woodgates lane, North Ferriby, East Yorkshire, HU14 3JD 180,000

Culrose Court, Stevenage, Hertfordshire SG2 8RS

ADAPTABLE DESIGN GUIDELINES

37 Riverside Court, Bideford, North Devon. EX39 2RZ River Retreat,

Transcription:

Briefing Accessible Housing Standards 2015 Purpose This briefing compares the technical specification provided in the 2015 Building Regulations M4(2), incorporating 2016 amendments, accessible, adaptable dwellings with the sixteen design criteria set out in its predecessor, the Lifetime Homes Standard (2011). For whom Technical officers, architects, developers, building control officers, access consultants, planning teams, housing decision makers and householders. Date Edition 2, June 2016

Introduction As the innovators and long standing champions of the Lifetime Homes Standard, Habinteg has published this new briefing to help inform the transition to the new accessible housing standards. Key to symbols Increased access, The concept of Lifetime Homes was developed in the early 1990s by a group of housing experts, including Habinteg and the Joseph Rowntree Foundation. The group was formed because of concerns about how inaccessible and inconvenient many homes were for large sections of the population. The Lifetime Homes Standard, 16 design criteria that can be universally applied to new homes at minimal cost, was developed to ensure that homes are inclusive, accessible, adaptable, sustainable and good value. The legacy of the Lifetime Homes Standard will now be taken forward through Building Regulations in the form of a national standard for accessible, adaptable dwellings set out in Part M(4),. We know that there is demand for accessible and easily adaptable homes similar to Lifetime Homes and this demand will only increase as the population ages. With the new regulatory standard in effect from 1 October 2015, planners, developers, architects and others will be looking to fully understand the technical details of the new arrangements. We have often referred to as broadly equivalent to Lifetime Homes although as noted in these pages we do have some concerns over omissions or reductions in certain aspects. This simple comparison looks at the 16 design criteria specified in the Lifetime Homes Standard and describes the access improvements or reductions delivered by the new national standard as described in Part M (4) category 2 national standard. Many people over many years have invested in developing and implementing the Lifetime Homes Standard. The technical design criteria are well understood and have been adopted across the country. Habinteg hopes this comparison document helps the new access standards become understood and adopted in the same way. We stress that this briefing is purely a comparison between Lifetime Homes and the new standard. It is not guidance on the use of new standards and contains no advice on approaching the new arrangements. Responsibility for the new standards lies with the Department for Communities and Local Government. As such, any queries or feedback about the new standards for access should be directed there. No change, Reduced access, 2 Habinteg briefing

1. Parking 1a. On plot (private) parking Potential to widen one space from 2400mm to 3300mm. comparison Parking space to be level (1:60). Parking space can be level (1:60) or, where unavoidable, gently sloping (defined as 1:60 to 1:20). Surface to be firm and with a maximum crossfall of 1:40. Space to have an external surface that is firm, even, smooth enough to be wheeled over, is not covered with loose laid materials such as gravel or shingle, and has a maximum crossfall of 1:40. Applies to carports which provide the only parking space; not applicable to garages. Exempts carports. Habinteg note: We would prefer to see carports included explicitly in any future edition - particularly where they provide the only parking space. 3

1b. Communal parking One space 3300mm wide x 4800mm long required close to each entrance/ core. comparison Surface to be firm. Space to have an external surface that is firm, even, smooth enough to be wheeled over, is not covered with loose laid materials such as gravel or shingle. Parking space to be level whenever practicable (1:60), gently sloping elsewhere, and with a maximum crossfall of 1:40. Parking space can be level (1:60) or, where unavoidable, gently sloping (defined as 1:60 to 1:20). N/A Includes s for drop-off points, where these are provided. Dwelling Garage Garage D 4 Habinteg briefing

2. Approach to dwelling from parking Level or gently sloping approach to the main entrance (or secondary) entrance to an individual dwelling, and/or to the main communal entrance. comparison combines LTH criteria 2 and 3, by describing the approach route as a whole including the route from any parking space. Distinguishes between gently sloping (1:60 to 1:20) and ramped (1:20 to 1:12). Where the overall rise of a ramp exceeds 300mm, an alternative stepped route is also required. This was not required under LTH. Slopes must provide level landing 1200mm long. Paths to be minimum 900mm wide in the curtilage of a dwelling and 1200mm wide if communal. No regarding gates. Gates to have clear opening width of 850mm and a 300mm nib to the leading edge. 5

3. Approaches to all entrances As far as practicable, to be as Criterion 2. Exemption for steeply sloping sites may be granted by Planning Authority. comparison Criteria 2 and 3 are now combined under Category 2 as noted previously. No exemptions will be granted; dwellings must now have step-free access to the private entrance or can only be classified as Category 1. Habinteg note: We believe level access can be delivered in steeply sloping sites. Planners should seek robust demonstration that Criterion is not possible on a given plot before agreeing a default to Category 1. 6 Habinteg briefing

4. Entrances All entrances lit with fully diffused luminaires. comparison Lighting now only required to main entrances. (Passive infrared sensor (PIR) lighting or similar to principal private entrance and principal communal entrance ). Accessible threshold to all entrances maximum 15mm total height. Slopes on sills supporting the threshold towards external landing not to exceed 15 o. Exemption for doors onto a balcony or terrace located above habitable rooms. All external doors to be accessible including doors to and from private garden, balcony, terrace, garage, car port or conservatory. Minimum effective clear opening width to all dwelling entrance doors 800mm. Now measured as clear opening width and increased to 850mm. Communal doors 800mm (or 825mm if approach not head on and corridor not 1500mm). Now measured as clear opening width and increased to 850mm. 300mm nib to leading edge / pull side to all entrance doors. Nibs to be retained for 1200mm beyond door face. 7

4. Entrances continued... All main entrances to be covered. Cover advised to be minimum 600mm deep (900mm deep typical) to private entrances and minimum 900mm deep (1200mm deep typical) to communal entrances; width to exceed width of door and any controls. comparison Minimum 600mm deep x 900mm wide cover required to principal private entrance and minimum 900mm deep x 1200mm to principal communal entrance. All entrances to have level external landings. 1200 x 1200mm to main dwelling entrance, and 1500 x 1500mm to main communal entrance. No regarding matting. Entrance matting should not impede wheelchair use. No regarding porches. Where a lobby or porch is provided (private or communal) doors to be minimum 1500mm apart and with minimum 1500mm between door swings. 8 Habinteg briefing

5. Communal stairs and lifts All principal access stairs (even when lift provided) to have easy-going pitch; maximum 170 risers, minimum 250mm goings. comparison Handrails at 900mm and extending 300mm top and bottom. Handrails between 900-1000mm but not required to extend by 300mm as lift now required. Contrasting step nosings and closed risers. Lift not required but when provided, minimum internal dimensions for lift car to be 1100mm x 1400mm. Lift (or other form of step free access) required to all dwellings with entrances above ground, lift car size unchanged. Lifts to have clear 1500mm x 1500mm landings all floors. Lift controls to be 900mm to 1200mm high and 400mm back. 9 Habinteg briefing

6. Internal doorways and hallways Minimum hall width 900mm; can reduce locally to 750mm at pinch points / obstructions away from doorways. comparison Minimum communal corridor width 1200mm; can reduce locally to 1050mm away from doorways. Minimum clear opening width to doorways in dwelling: 750mm (head on approach or at right angles where hall 1200mm wide) 775mm (where at right angles in hallway 1050mm wide) 900mm (where at right angles in 900mm hallway). No change. No change. Clear opening width reduced to 800mm when at right angles in 900mm hallway. En-suite shower rooms are exempt unless they are satisfying entry level WC or bathroom s. 300mm nib to leading edge/pull side of all dwelling doors in the entrance level. 300mm nib to leading edge/pull side of all communal doors. Requirement extended to cupboard doors when large enough to be entered. No change except to doors into communal stairwells where 300mm is only required if this is on the approach route. 10

7. Circulation space 1500mm turning circle or 1700mm x 1400mm ellipse in living areas and dining areas. comparison No longer required. 1200mm clear in front of kitchen units and appliances. Main bedroom able to provide 750mm to both sides and foot of bed. Other bedrooms to offer 750mm to one side of bed. 750mm required at the foot of the bed in all double bedrooms. 750mm clear route to window in all bedrooms, including to foot of bed where necessary. 11

8. Entrance level living space. A permanent living space or dining space within or in addition to the kitchen (i.e. a socialising space) at entrance level. comparison 9. Potential for temporary entrance level bed-space comparison Corner of living space suitable for single bed, with 750mm wide access, power socket and able to be screened. Not explicitly required. 1 1. Although the physical space is provided by default in the majority of dwellings. 12

10. Entrance level WC and shower drainage WC and access zone and flush located centrally or away from side wall. comparison Flush position no longer specified. Basin and access zone, may only encroach up to 200mm into WC access zone. Floor gulley and falls for future level shower (may be capped initially). Minimum compartment 1450mm x 1850mm. 1 and 2 bed houses can have Part M size WC/ cloakroom. A floor drain for future accessible shower should be included. Future shower provision no longer required in 1 and 2 bed houses with smaller WC (Category 1). 13

11. WC and bathroom walls All WC, bathroom and en-suite walls strengthened (between 300 and 1800 above FFL) to take grab rails. comparison Height band removed. Strengthening now required to full height of wall. 12. Stairs and potential through floor lift in dwellings. Stairs to be minimum 900mm wide (measured 450mm above pitch line). comparison Clear width reduced to 850mm. Unless entrance level has the living accommodation, kitchen, a main bedroom and Criterion 14 bathroom on the entrance level, potential through floor lift route to be identified. Identification of potential through floor lift route no longer required. Extra prohibiting steps within the entrance level. 14

13. Hoist potential Structure above ceiling to a main bedroom and the bathroom of Criterion 14 to be capable of supporting hoists. comparison No longer required. Unless at entrance level, main bedroom and accessible (Criterion 14) bathroom should be on the storey above or below the entrance storey. No longer required. Main bedroom and accessible (Criterion 14) bathroom should have a route between them not passing through living areas. No longer required, route principal bedroom and accessible bathroom required only to be on same floor. No specification for route between them. Habinteg note: We believe that unless at entrance level a main bedroom and criterion 14 bathroom should be on storey above or below entrance level to enable potential access using a stairlift and / or reduce essential stair use for some people. It also makes access via a through floor lift adaptation more achievable. 15

14. Bathroom An accessible bathroom to be provided close to, and on the same storey as a main bedroom. If not the entrance level, this floor to be adjacent to the entrance level. comparison Required to be on the same floor but no longer required to be on a particular floor as noted above at 13. WC access zone and flush located centrally or away from side wall. Flush position no longer specified. Basin with approach zone (1100mm to front of pedestal etc) Basin now allowed to encroach up to 300mm into WC access zone. Either bath or accessible level shower installed. Unless provided elsewhere in the dwelling, bathroom should make provision for future level access shower. Potential for 1500mm turning circle (or 1700mm x 1400mm ellipse) if bath removed and accessible shower provided. 16

15. Glazing and window handle heights Glazing in principal living space to begin no higher than 800mm (+50mm tolerance) i.e. 850mm from floor. comparison Any full width transom within the field of vision (up to 1700mm from floor) to be at least 400mm in height away from any other transom or balcony balustrade. No longer required. An opening light to a window in each room should have handles no higher than 1200mm from the floor. Window handle height increased to 1400mm except for one window in the principal living area. 17

16. Location of service controls Any service controls that need to be operated or read frequently, or in an emergency, should be located within the height band of 450 to 1200mm and at least 300mm from any room corner. Includes electrical, TV and phone outlets; CSUs, heating programmers and controls, stopcocks and radiator controls. comparison CSUs must be at 1350 to 14500mm due to Part P Regulations. Radiator and cooker hood controls are exempt from height specifications. Habinteg note: We believe radiator controls should be provided at an inclusive height. 18

Conclusion Of the specifications set out across all 16 criteria, 18 have been disapplied or downgraded, whilst 16 have been improved or added. Whilst we welcome the improvements, in Habinteg s view, some issues remain that, if addressed, would enhance the practical use of the building by the widest range of people. Namely: Norrower staircases. Increase of window handle height and radiator controls. Allowability of parking to be gently sloping. Exemption of car ports from s to be capable to be widened to 3.3m. Deletion of for main bedroom and accessible bathroom to be on the entrance level or an adjacent storey to entrance level. However the new standard is an important set of specifications. They make dwellings usable by a wide range of householders, from families with young children to older less agile people and anyone living with a mobility impairment whether temporarily or on a longer term basis. The standard, along with M4(3) Category, describing specifications for wheelchair accessible dwellings is, as of October 2015, one of the optional access standards that apply in England. For further information about the policy context for this standard, see Habinteg s October 2015 briefing, 7 points about the Housing Standards. 19

Further information Published by Habinteg Holyer House 20-21 Red Lion Court London EC4A 3EB Telephone 020 7822 8700 Fax 020 7822 8701 direct@habinteg.org.uk www.habinteg.org.uk For information or to raise questions about the Part M(4) of the building regulations 2015, please contact Department for Communities and Local Government (DCLG) via www.gov.uk. For training on the use of the new standard or consultancy support with the design or provision of accessible homes, please contact Habinteg s specialist team, Centre for Accessible Environments (CAE) via www.cae.org.uk or 020 7822 8232. To keep up to date with news and case studies about accessible housing design register for the free Lifetime Homes newsletter at www.lifetimehomes.org.uk. For further information about the policy context for this standard, see Habinteg s October 2015 briefing, 7 points about the Housing Standards at www.habinteg.org.uk. 20