Room Numbering Standards Version 1.6 Jan 2015

Similar documents
ROOM NUMBERING STANDARDS

Floor and Room Numbering Guidelines

FLOOR AND ROOM NUMBERING GUIDELINES

Element Z General Design Requirements Owner Standards and Other Requirements

S01- ROOM NUMBERING STANDARDS

Strata Plan Fast Facts

PROCEDURES FOR ROOM NUMBERING STANDARDS

BUILDING DIVISION SIMPLIFIED BUILDING PERMIT FEE SCHEDULE January 01st, 2019 to December 31st, 2019

MOUNT GRAVATT- CAPALABA ROAD

ADAPTATIONS POLICY 2012

Room & Floor Renumbering. Floor Level Numbering Room Renumbering

SCHEDULE A. Permit fees shall be calculated based on the formula given below, unless otherwise specified in this schedule:

A Brief Overview of the New BOMA Measurement Standards for Lawyers Jan. 20, 2011 By William B. Tracy, MBA, NCARB

RT-8 District Schedule

SPECIALIZED RESIDENTIAL APARTMENT (R.4) ZONES

RM-3 District Schedule

Permit fees shall be calculated based on the formula given below, unless otherwise specified in this schedule:

THE SILVER FIN BUILDING ABERDEEN

RT-5 and RT-5N Districts Schedule

TECHNICAL INFORMATION PAPER - METHODS OF MEASUREMENT

RT-7 District Schedule

The New NYC Building Code Chapter 11 Accessibility. New York City Department of Buildings. Technical Affairs. Keith Wen, R.A. Copyright Materials

Access to and use of buildings

West 1st Avenue By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

Natural Light & Ventilation. Sources. Regulation 45 (1) & 45 (2) A Public road with right of way. A Courtyard or Open Space within the site.

SCHEDULE A TO BY-LAW NUMBER (Amended by By-law ) CLASSES OF PERMITS AND PERMIT FEES

CITY OF TORONTO. BY-LAW No (OMB)

71-77 Gheringhap Street. An exciting new development has commenced in the centre of Geelong s commercial heart

City of Vancouver Zoning and Development By-law Planning, Urban Design and Sustainability Department

Ontario Municipal Board Decision issued July 28, 2014 and Orders issued December 4 and 17, 2015 in Board File No. PL CITY OF TORONTO

classic exterior contemporary interior

Section One: General Information

International Village By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

1133 West Georgia Street By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

South-facing 3 bedroom Villa with pool, north of Alvor, West Algarve VILLA IN MEXILHOEIRA GRANDE

Authority: Ontario Municipal Board Decisions/Orders issued June 26, 2014, August 24, 2015 and July 13, 2016 in Board File PL CITY OF TORONTO

SELLING YOUR HOUSE. make sure you have all the planning consents and building warrants in place FOR SALE

q/., S Lt _ _.._--.

Accessible Housing Standards 2015

FEES FOR BUILDING REGULATION APPLICATIONS The Land Planning and Development (Fees) (Amendment) Regulations, 2017

Chargeback Reports: From CAD Drawings to Database Report

THIS CHECKLIST HAS BEEN AMENDED TO INCLUDE ONLY LEVEL ONE CRITERIA AS REQUESTED BY TIR REAL PROPERTY. As such it does not form a complete Checklist.

RM-7, RM-7N and RM-7AN Districts Schedules

Equality and Access Plan The Abbey School, Reading

The BSF project, September to December A photo timeline by Jack and Jacob Harris

Space and Door Numbering Standards Facilities Planning and Construction

BUILDING CODE COMMISSION

Unity House ST DAVID S PARK, EWLOE, CH5 3XT

COMO LAKE AVE. LAND ASSEMBLY

TO LET. High Quality Office Accommodation. Glasgow G2 7HF LAST AVAILABLE SUITE

RM 4 and RM 4N Districts Schedule

Moonee Valley Moreland Port Phillip Stonnington Whitehorse Wyndham Yarra

MONTE MARE SUZANN

Urban Planning and Architectural Standards for Social Housing Architectural Design

RT-11 and RT-11N Districts Schedules

City of Vancouver Zoning and Development By-law Planning, Urban Design and Sustainability Department

Scarborough Community Council Item SC32.7, as adopted by City of Toronto Council on July 23, 24, 25, 26, 27 and 30, 2018 CITY OF TORONTO

Project overview. Golden Sand Hotel DOHA QATAR

THE RUSSELL BUILDING. LIVERPOOL ONE.

RM-8 and RM-8N Districts Schedule

Etobicoke York Community Council Item [#], as adopted by City of Toronto Council on [date] Draft Zoning By-law Amendment (March 20, 2019)

RT-3 District Schedule

Purpose. Scope. Stairway Identification Signs. Emergency Evacuation and Stairwell Signage Requirements

Harmony Row Dublin 2. Dublin 2

FOR SALE or TO LET UNIT 6, NAVIGATION DRIVE HURST BUSINESS PARK DUDLEY, DY5 1UT

Division 4: Commercial Community 1 (C-C1) District

Lease For Sale due to retirement Beverley Town Centre Hotel and Restaurant TUDOR ROSE HOTEL & RESTAURANT

exeter event venues and hospitality University of Exeter Event Exeter Venues The Great Hall and Devonshire House

Secondary Suites Design Standards & Guidelines for houses built after July 1998

G L A S G O W G 2 5 S G

RT-2 District Schedule

Part 7 Uptown Mixed-Use Centre Zones

Fifth 50,500 4,

CITY OF TORONTO BY-LAW NO. ~-20~

FACT SHEET SANDTON GATE PHASE 1

Addressing Guidelines I. Introduction

PROPOSED AMENDMENTS TO THE DERBY ZONING REGULATIONS AUGUST 12, 2008

APPLICATION OF SECTION 3.8 OF THE 2012 ONTARIO BUILDING CODE FOR: BARRIER-FREE AUDIT OF SENECA COLLEGE NEWNHAM CAMPUS TORONTO, ONTARIO

Residential Single Detached Dwelling Districts (RS)

THE CORPORATION OF THE CITY OF GUELPH. WHEREAS the City of Guelph will experience growth through development and redevelopment;

Zoning Advisory Group Workshop. Corporation of Delta June 29, 2016

Understanding Accessibility Features to Meet Housing Needs

BYLAW NUMBER 20P2017

City of Vancouver Zoning and Development By-law Planning, Urban Design and Sustainability Department

BYLAW NUMBER 159D2016

B. Parties Involved: Applicant: Ali Eslami, P.O. Box 4623, Berkeley, CA 94794

Codes Checklist Document 3

148,000 sq ft. Net area of Grade A Office Accommodation

R IVERSIDE COURT TO LET/MAY SELL. Avenue De Clichy, Abermorlais, Merthyr Tydfil, CF47 8LD. On behalf of:

Amendments to Richmond Zoning Bylaw 8500 to Implement 2017 Affordable Housing Requirements

Understanding Accessibility Features to Meet Housing Needs

THE DISTRICT OF NORTH VANCOUVER

RIVERSDALE FEASIBILITY STUDY. prepared by

TO LET / FOR SALE DETATCHED OFFICE 12,000 SQ FT

Australasian Health Facility Guidelines

SPECIALIZED COMMERCIAL RESIDENTIAL (CR) ZONES

ACCESSORY DWELLING UNITS

(2) Determining Occupant Loads for the Operation of a Building (The Alberta Fire Code)

Rénovation. municipal

CAS PAR. Comprehensive Assessment and Solution Process For Aging Residents INTRODUCTION MATERIALS NEEDED 1 CASPAR

Transcription:

University of New South Wales Room Numbering Standards Version 1.6 Jan 2015 Prepared by Space Management, Facilities Management University of New South Wales

Table of Contents 1. Purpose... 3 2. Building Numbers/Building Grid Codes... 3 3. Level Naming and Numbering... 3 4. Room Numbering... 4 4.1 Start Point... 4 4.2 Direction/Flow... 4 4.3 Useable Space... 5 4.3.1 Rooms within Rooms... 5 4.3.2 Workstations... 6 4.3.3 Communications Rooms... 6 4.3.4 Residential Accommodation... 6 4.4 Non-Useable Space... 7 4.4.1 Stairwells... 7 4.4.2 Corridors... 8 4.4.3 Service Cupboards & Risers... 9 4.4.4 Unenclosed Covered Areas (UCA)... 10 4.4.5 Lift Numbering... 11 5. Renovations & Refurbishments... 12 6. Numbering Requests & Contact... 14 7. Acknowledgements... 14 8. Appendix 1 :.15 Page 2

1. Purpose These numbering standards have been developed by UNSW Space Management (SM) and must be followed throughout University controlled facilities for the purpose of standardizing room numbers. These standards must be followed, except in cases of minor renovations to existing buildings, where the building s existing numbering system can be extended. All room numbering must be approved by SM CAD staff prior to the commencement of construction. 2. Building Numbers/Building Grid Codes Facilities Management is responsible for allocating all building numbers/codes. SM will advise all relevant parties in the University when a new building number/code has been created. 3. Level Naming and Numbering New building floors/levels shall be numbered as outlined in Table 1 below. Note: In existing buildings where the First Floor numbering protocol has been used the existing numbering is to be preserved wherever possible. Table 1 FLOOR LEVEL FLOOR LEVEL NAME Notes CODE B Basement Relates to the lowest level of the building. In most instances this is nonhabitable space (Eg. basement car park) LG Lower Ground G Ground Relates to the floor of a building at, or nearest ground level M Mezzanine An intermediate floor commonly between the ground floor and level 1 L01 L18 Level 1-18 Level 1 relates to the first floor above ground level R Roof R1 Roof Level 1 R2 Roof Level 2 Page 3

4. Room Numbering General UNSW uses a Computer Aided Facilities Management (CAFM) program, Archibus, which requires all interior enclosed rooms, as well as covered unenclosed spaces to be given a room number. UNSW uses a number by room type numbering system in which numbering standards differ between usable, non-usable and unenclosed covered space (the numbering standard for non-usable space is further divided into services and all other ). Numbering standards for each room type are outlined below. 4.1 Start Point Numbering of a floor will commence at the main point of entry to the floor or main foyer of the floor. 4.2 Direction/Flow Rooms are to be numbered in a clockwise direction as in Figure 1 and Figure 2 below. Figure 1 START Entrance Figure 2 START Entrance Page 4

4.3 Useable Space Room numbers for usable space are a combination of two numbers - the first number indicating the level and the second indicating the room number commencing from the number 01. Example of room 1003 on level 10: 10 03 Indicates room number Indicates level number Note: Kitchens are usable space and are numbered as such, but differ from Tea Rooms (tea making facilities without a stove top), which are classified under non-usable space and numbered as non-useable space. Refer to Appendix 1 for a full list of Non-Useable spaces 4.3.1 Rooms within Rooms Each room entered from a corridor should have a unique room number without an alphabetical suffix (eg. 101, 102, 103, etc.) Where a room is located within another room, then the inner room shall carry the same number as the room through which it is entered, plus an alphabetical suffix to uniquely identify it. Example of room 117A: Figure 2 Entry for both 117 and 117A Page 5

4.3.2 Workstations In an open plan office with numerous workstations, each workstation is given its own number. Workstations in an enclosed office are not to be numbered. Only the room or space is to be given a number. Following the level number, workstations are given a WS code followed by the workstation number. For example workstation 201WS01. 210 WS 01 Indicates the workstation number Indicates it is a workstation Indicates room number Figure 3 Example of Workstation numbering 4.3.3 Communications Rooms Communications rooms are included in usable space and shall be numbered sequentially with other useable rooms on the floor. Any existing communications room numbers are not to be altered unless approved by UNSW Space Management. Note: Communications risers are non-usable space and numbered using the services standard. 4.3.4 Residential Accommodation Usable space in residential accommodation is to be numbered in a specific order according to room type: 1. Bedrooms/Units 2. All other usable space The numbering sequence starts with bedrooms/units and skips all other usable space until all bedrooms/units have been numbered. The next number in the sequence is assigned to the usable space nearest to the entry/foyer and continues in a clockwise direction. Page 6

4.4 Room Numbering Non-Useable Space Non-useable rooms such as corridors, stairs, hallways, amenities, and plant rooms will have a Q identifier after the building level and before the room number. Service cupboards and risers, which are also non-usable and non-habitable spaces, are given a prefix corresponding to the service type. This is outlined in chapter 4.4.3. Refer to Appendix 1 for a list of Non-Useable spaces. Example of room 10Q3 level 10: 10 Q 3 Indicates room number Indicates the room is non-usable Indicates level number 4.4.1 Stairwells Stairwells should be numbered in a consistent ascending order throughout the building where applicable. For example, a stairwell ascending from the bottom to the top of a building will be given the same space number on each floor. The only difference will be the floor number for each level. For example, stairwell 2Q20 on level 2 becomes 3Q20 on level 3. Level 2 Level 3 Page 7

4.4.2 Corridors A corridor will be assigned a number for each change of direction as per figure 4 and table 2. The corridor space is considered to be an area which is line of sight when moving from one space to another Note: Corridors separated by fire doors will also have a unique number assigned to each space as per figure 5 Figure 4 Table 2 Room Code 1Q30 1Q31 1Q32 FLOOR LEVEL NAME Corridor 1 st change of direction to corridor 2 nd change of direction to corridor Figure 5 Fire Door Fire Door Page 8

4.4.3 Service Cupboards and Risers Service cupboards and risers (electrical, communications, fire and hydraulics) will be assigned a letter indicating the type of service, followed by the level number, Q letter and then the space number. Note: Numbering for service cupboards and risers will commence at the main point of entry to the floor or main foyer of the floor and continue in a clockwise direction. Any non-accessible service risers are not numbered. Services and Amenities room numbering Example on level 10: E 10 Q 03 Indicates the space number Indicates that the space is in the non-usable category Indicates the level number Indicates the service type Table 3 below Outlining the services used and the appropriate numbering. Services Prefix Example of room number (on level 1) Electrical E E01Q01 Hydraulic H H01Q01 Communications C C1Q01 (if building has more than 9 levels, it will be 01 for level 1 and 10 for level 10). Fire Services F F01Q01 Security/Communications CS CS1Q01 (if building has more than 9 levels, it will be 01 for level 1 and 10 for level 10). Mechanical M M01Q01 4.4.4 Unenclosed Covered Areas (UCA) Unenclosed covered areas (UCA) are defined as any trafficable unenclosed areas such as verandas, balconies, under crofts, car parking stations and uncovered attached walkways. These spaces shall be assigned a U prefix, followed by the level number, Q letter and then the space number. Note: Numbering for UCA space will commence at the main point of entry to the floor or main foyer of the floor and continue in a clockwise direction. UCA room numbering Example on level 2: U 02 Q 01 Indicates space number Indicates the space is in the non-usable category Indicates level number Indicates UCA space Page 9

4.4.5 Lift Numbering The room number code for lift shafts will be made up of the following combination: Floor Level code Lift Service abbreviation Lift number as per Asset Management NOTE: Lift Numbering in most new constructions will have the numbers allocated. Please request the lift numbers from the FM Space management team. Lifts service types are as follows: Lift Type Names used by Asset Management Unit Lift Abbreviation (LS Lift Service) Room Type Description Room Name Passenger Lift LS Lift Shaft Lift (number) Disabled Services LS Accessible platform Lift Accessible Platform Lift (number) Goods Lift LS Lift Shaft Goods (number) Hoists LS Hoist Hoist (number) Dumb Waiter LS Lift Shaft Dumb Waiter Lift (number) Example of lift numbering Level number+ls+lift number Floor Example (Lift 1) Example (Lift 111) Basement BLS001 BLS111 Lower LGLS001 LGLS111 Ground Ground GLS001 GLS111 Mezzanine MLS001 MLS111 Level 2 L02LS001 L02LS111 Level 10 L10LS001 L10LS111 Page 10

5. Renovations and Refurbishments: Renovations and refurbishments involve the creating new room numbers, reusing old room numbers, and retiring existing room numbers. Example 1 Retiring room numbers and reusing room numbers (many rooms to fewer room) Figure 7 Figure 6 After refurbishment (Figure7) Many of the existing numbers have been made redundant and relevant numbers are re-used to keep the sequence going as the space is refurbished. Page 11

Example 2 Creating new room numbers Before Refurbishment (Figure 8) G16 is a dance hall. After Refurbishment (Figure 9) A refurbishment has transformed room G16 into an open office space with many rooms. Room number G16 is reused and new room numbers have been created for the new spaces (In this example G17 is used in another part of the plan therefore the new room numbering begins at G18). Figure 9 Page 12

6. Numbering Requests & Contact All numbering requests and room number enquiries are to be directed to the Space Management Unit. Email: spacemanagement@unsw.edu.au 7. Acknowledgements FM Space Management would like to acknowledge the following Universities for their assistance in producing this document: The University of Technology Sydney, The University of Melbourne and The University of Sydney. Page 13

Appendix 1 Non-Usable Spaces (employ a Non-Usable Q numbering standard) Description Non-Usable - Bicycle Storage Shed Non - Usable Floor Area Car Park That Is Constructed As Part Of Another Building Non- Usable Floor Area Car Park Multi Storey - Free Standing Non-Usable - Child Care Undercover / Out Door Area Non- Usable Floor Area Circulation Space Non- Usable Floor Area - Cleaners Room Non- Usable Floor Area Garage Loading Bay Non-Usable - External Informal Learning Space Non- Usable Floor Area Lift Motor Non- Usable Floor Area Mechanical Plant Room Non- Usable Floor Area - Other Plant Room Non- Usable Floor Area Sub Station Non- Usable Floor Area Store Room - Uninhabitable Non- Usable Floor Area Switch Room Non- Usable Floor Area Kitchenette/Tea Room Non-Usable - Outdoor Undercover Tea Room Non- Usable Floor Area Toilets/Amenities/Accessible Non- Usable Floor Area Toilets/Change Room/Shower Room Non- Usable Floor Area Toilets/Amenities/Female Non- Usable Floor Area Toilets/Amenities/Male Non- Usable Floor Area Toilets/Amenities/Unisex Non- Usable Floor Area Veranda/Balcony Non- Usable Floor Area Service Riser Non-Usable Floor Area - Waste Management Non Usable Floor Area Toilet Accessible Female Non Usable Floor Area Toilet Accessible Male Non- Usable Floor Area Toilets/Amenities/Shower/Female Non- Usable Floor Area Toilets/Amenities/Shower/Male Non- Usable Floor Area Toilet/Accessible + Shower Non- Usable Floor Area Accessible Shower Non- Usable Floor Area Ambulant Toilet Non- Usable Floor Area Ambulant Toilet/Toilet Non- Usable Floor Area Ambulant Toilet/Toilet/Female Non- Usable Floor Area Ambulant Toilet/Toilet/Male Non- Usable Floor Area Accessible Toilet/Toilet Non- Usable Floor Area Accessible Toilet/Baby Change Non- Usable Floor Area Other Toilets Non-Usable Floor Area - Accessible Platform Lift Non- Usable Floor Area - Accessible Ramp Non- Usable Floor Area - Gas Manifold Room Non- Usable Floor Area - Code Not In Use Non- Usable Floor Area - Code Not In Use Non- Usable Floor Area Lift Shaft Non- Usable Floor Area Mechanical Service Riser Non- Usable Floor Area - Communication Riser Non- Useable Floor Area - Fire Services Cupboard Non- Usable Floor Area - Electrical Cupboard Non- Usable Floor Area - Code not in use Non-Usable Floor Area - Hoist Unenclosed - Covered Car park/carport Unenclosed - Other Covered Area Unenclosed - Code Not in Use Page 14