adjustable height mechanisms

Similar documents
Access Statement for Self-catering property Barbers Cottage

ADAPTATIONS POLICY 2012

System furniture. Essentiel BENCH

Residential Accessible, Type A, and Type B Dwelling Unit Requirements 2012 International Building Code and 2009 ICC/ANSI A117.1

BUILDING CODE INTERPRETATION

Arlington County. Smart Choice Homes. Arlington County. Homes for all of us. Homes for a lifetime. Home

Understanding Accessibility Features to Meet Housing Needs

Understanding Accessibility Features to Meet Housing Needs

Tables and worktop extensions

This provides two storey accommodation with four bedrooms (one fully accessible), accessible living accommodation, and kitchen.

Brighton & Hove City Council. Standards for Licensable Houses in Multiple Occupation

National Trust Cottages Access Statement

Access Statement for Lorne House Bed & Breakfast

Kitchen 5m² 6m² 7m² 9m² 11m² Total communal living space** 13.5m² 17m² 18m² 20m² 27.5m²

Accessible Accommodation There are nine adapted accommodation units at Longleat:

Kitchen ranges. The Options family. The Eton family

As society changes, so do our housing needs. Factors

Kvadrat Soft Cells Installation guide

Access Statement: Self-Catering Cottage

ACCESS STATEMENT FOR THE APARTMENT ALEXANDER S

Installation and handling instructions PITT cooking in kitchen worktops

National Trust Cottages Access Statement

Access Statement v1.0. West Wight Cottages. Tanners Access Statement. 1 P a g e

Give the name and distance of the nearest railway station. Describe the type of surface from the car park to the main entrance.

Parking. Access Statement Summerhouse Cottage Beadnell. Pre Arrival. Chathill-3.5 miles/ Alnmouth-15 miles/ Berwick upon Tweed-25 miles

Residencial El Prado - "Viviendas desde *. Plaza y Trastero Incluido" Ensanche de Vallecas (caseta nº 1)

West Wight Cottages. 2 The Granary Access Statement.

Residence 51. LOCATION John Kennedy Area, Limassol. STATUS Under Construction for SALE. COMPLETION DATE September 2010

Access Statement for Dellfield Self-Catering unit

3M Proptic High-Capacity Optical Distribution Frames

Sophia 6mx10m (60m2) Prefabricated 2BR + Bathroom & Kitchenette, 3 STAR Model $ 59,999

THIS CHECKLIST HAS BEEN AMENDED TO INCLUDE ONLY LEVEL ONE CRITERIA AS REQUESTED BY TIR REAL PROPERTY. As such it does not form a complete Checklist.

Give the name and distance of the nearest railway station. Describe the floor surface e.g. tile/wood/rugs/carpet (thick/short pile).

ACCESS STATEMENT FOR THE HEMMEL

Accessibility Guide for Corran Bunkhouse

Affordable Rental Housing Design Guidelines

National Trust Cottages Access Statement

PLOT 5 KINGSOAK HITCHIN

STAINLESS STEEL PRODUCTS

I M P E R I A L VISTA A N N I V E R S A R Y E D I T I O N Y E A R S

Access Statement Seaton 22 St Aidan s Seahouses NE68 7SS

Access Statement for Primrose Farm

Access Statement for Stoney Steps Flat 5 Ullswater Court Inn on the Lake Glenridding

Underfloor. Heating Kits

GUIDELINES FOR BUILD OVERS

SALES LETTINGS NEW HOME SALES LAND PROPERTY MANAGEMENT AUCTIONS FINANCIAL ADVICE AND MORTGAGES ENERGY PERFORMANCE PROVIDER

Requirements for accepted development and assessment benchmarks for assessable development

LAKESIDE URBAN HOUSES

ADAPTABLE DESIGN GUIDELINES

Access Statement Henderson House 19 Henderson Street Amble NE65 0AE

Access Statement for Cuckoo Croft Barn

AVA APARTMENTS THREE

LEGEND. A Apartments. T Townhouses

M O D E R N L I V I N G A T A F F O R D A B L E P R I C E S

Article 3. SUBURBAN (S-) NEIGHBORHOOD CONTEXT

About Urban Kitchen Benefits. Urban Kitchen with DYNAMIC SPACE. The Urban Kitchen Showroom. 2-room Single Row. 3-room Galley.

MaRsh & MaRsh properties

Each property will be built to a high specification and will include garaging or allocated parking.

National Trust Cottages Access Statement/Guide

splittest.com page 2 / 5

Glamping Room Super-pod 4m x 7.2m model

Emil Møllers Gade 41 Horsens, Denmark

Residencial Illes Medes Avda. del Garraf s/n,

Access Statement The Hollies Ingram Road Bamburgh NE69 7BT

Direction Note FIRST FLOOR:

Access to and use of buildings

CALA DE MIJAS COSTA DEL SOL 2, 3 AND 4 BEDROOM CONTEMPORARY APARTMENTS, PENTHOUSES AND VILLAS

National Trust Cottages Access Statement

National Trust Cottages Access Statement

Give the name and distance of the nearest railway station. Describe the streets in the area surrounding the property

ACTIVAN SPARE PARTS PARTS DIAGRAMS

Access Statement for Willow Nook Cottages

INITIAL ANNEXURE C SPECIFICATION AND SCHEDULE OF FINISHES: 1. GENERAL, BRICKWORK & PAINTING

Russell House Brighton

THE VIEW WARREN ROAD DONAGHADEE

THE VIEW WARREN ROAD DONAGHADEE

IT S IT S HOME ME TIME

Guide to Renting. Real Estate. Real Estate

Newcastle Court. 1, 2 and 3 bedroom apartments Newcastle Court, Eastcote Lane, Northolt, UB5 4FR

Highmill Court Shepherds Loan Dundee

MONTE MARE SUZANN

MaRsh & MaRsh properties

4/9 Comber Place, Comber Heights, Johnsonville, Wellington. Architect s impression of 4/9 Comber Place

Wheelchair homes design guidelines. Guidelines to achieve the necessary standards for wheelchair users dwellings

Accessibility Guide for Buttermere Cottage

33 North Avenue, Gosforth Newcastle upon Tyne NE3 4DQ

Access Statement for Harbourside Cottage

National Trust Cottages Access Statement

ACCESSIBLE BUILDING (F1) HOUSING DESIGN (G1)

BUILDING QUALITIES Santa Pola Bahia Arena GROUNDING WORKS STRUCTURE

BUILDING SPECIFICATIONS

THE HONG KONG HOUSING AUTHORITY. Memorandum for the Building Committee. Review of Harmony Block Designs

OLD MANSE GARDENS GREYSTONE ROAD, ANTRIM

apartments Chillingham Garden Village PERSIMMON Together, we make a home PERSIMMON Together, we make a home

Recommendations to Improve Access to Housing for Ontario Seniors

Facilities providing accommodation for the public (e.g. Hotels, hostels, guesthouses, self catering apartments).

Access Statement for Helios, 3 The Spinnakers, Valley Road, Carbis Bay

Arriving and Getting In

Offers Around 285,000

National Trust Cottages Access Statement

Transcription:

adjustable height mechanisms lifts to make worktops height adjustable mechanisms for wall cupboards adaptability create adaptable working environments enable working spaces to suit all users and carers WWW.ENWARE.COM.AU

OUR ADJUSTABLE HEIGHT MECHANISMS HAVE BEEN DESIGNED WITH A FOCUS ON THE VARYING NEEDS OF USERS AND CARERS. IN THE ADJUSTABLE HEIGHT WORKING ENVIRONMENT, STANDING AND SEATED USERS, INCLUDING WHEELCHAIR USERS, CAN WORK CONCURRENTLY COMFORTABLY AND SAFELY. Adjustable height solutions provide the added advantage that users can participate in working and other joint activities irrespective of differences in mobility and physical ability. Our adjustable height mechanisms, onto which worktops and cupboards of your own choice are mounted can be used in the following applications: Health care facilities Aged care facilities Rehabilitation centres Shared Housing Private homes Educational facilities The range of height adjustable mechanisms encompasses three lift systems: electric, manual and brackets. ADVANTAGES FOR THE USER INDEPENDENCE Our products help users to be as self-sufficient as possible. The solutions we offer fit individuals of all types children, adults, those who can walk, and those who can sit. SELF-ESTEEM Being able to do things for oneself in safe surroundings that are functional creates self-reliance in daily routines. DETAIL The system s efficient design, the choice of materials, and the perfection of detail all come together in the integrated working environment - without compromising functionality or comfort. FOR CARERS WORK ENVIRONMENT Using our products means a minimum of physical strain, creating an efficient safe working environment. FLEXIBILITY Products can be adjusted to meet specific needs of the primary user, or users, and of carers. 2 FOR PLANNERS AND ADMINISTRATORS RESPECT The flexibility of these products allows carers to assist users in their activities without having to sacrifice the users integrity and dignity. ADVICE We can offer advice on room design that will address the needs of users and healthcare professionals FUTURE-PROOFING Our systems make conversion and remodelling unnecessary if users needs change or if the working environment is to be used by new users. DESIGN With our solutions you can focus on flexibility, functionality and economy without compromising on design or layout.

WALL MOUNTED MOUNTED WORKTOP LIFTS WORKTOP - ELECTRIC LIFTS - Electric An electric height-adjustable worktop is ideal in situations where various users both seated and standing use the same workplace. This is equally true in private homes as well as larger centres with common facilities such as group homes and care centres. Frequent use The cross brace is delivered to your required measurements, no on-site cutting is required Electric worktop lifts can be adjusted in height over a range of 280 mm Lift heights are adjusted via switches in the front edge of the worktop or via remote control (see page 8) Operating switches can be placed anywhere in the front edge The switches are colour-coded aluminium to operate worktops, and red to operate wall cupboards. Maximum load (evenly distributed): 100 kg, including worktop Electric height adjustable worktops should be fitted with a safety bar to prevent injuries. See page 8. When using adjustable worktops next to each other and/or adjustable cupboards above the adjustable worktop, safety interconnections should be included. The front edge of the worktop should be as narrow as possible, but must be at least 70 mm to permit installation of height adjustment switches. A flexible waste system must be ordered for worktops containing sinks. See page 8. Sinks and hobs should be insulated underneath to prevent burns to thighs and knees. EP-RK1010 - Electric lift for worktop, 600-1000 mm in length Includes 2 telescopic legs, 2 brackets, cross brace and switch EP-RK1011 - Electric lift for worktop, 1001 1400 mm in length Includes 2 telescopic legs, 2 brackets, cross brace and switch EP-RK1010 EP-RK1012 - Electric lift for worktop, 1401 2000 mm in length Includes 2 telescopic legs, 3 brackets, cross brace and switch EP-RK1013 - Electric lift for worktop, 2001 2400 mm in length Includes 2 telescopic legs, 4 brackets, cross brace and switch EP-RK1013 EP-RK1014 - Electric lift for worktop, 2401 3000 mm in length Includes 2 telescopic legs, 5 brackets, cross brace and switch EP-RK1014 3

WALL MOUNTED WORKTOP LIFTS - MANUAL Worktops can be adjusted in height using a crank handle to cater for both seated and standing users. These are most commonly used in situations which do not require frequent, daily adjustment. The cross brace is delivered to your required measurements, no on-site cutting required Manual worktop lifts can be adjusted in height over a range of 300 mm Lifts can be used with worktops, with or without an edge The crank handle socket can be positioned anywhere along the front edge, except under a sink or hob. For worktops with an edge, a cover plate protects the crank handle socket The crank handle can be fastened under the worktop when not in use Maximum load (evenly distributed): 100 kg, including worktop If an edge is required under the worktop, this should be as narrow as possible, but must be at least 100 mm to allow room for the crank handle. A flexible waste system must be ordered for worktops containing sinks.see page 8. Sinks and hobs should be insulated underneath to prevent burns to thighs and knees. EP-RK1110 - Manual lift for worktop, 600-1000 mm in length Includes 2 telescopic legs, 2 brackets, cross brace and crank handle EP-RK1113 EP-RK1111 - Manual lift for worktop, 1001 1400 mm in length Includes 2 telescopic legs, 2 brackets, cross brace and crank handle EP-RK1112 - Manual lift for worktop, 1401 2000 mm in length Includes 2 telescopic legs, 3 brackets, cross brace and crank handle EP-RK1113 - Manual lift for worktop, 2001 2400 mm in length Includes 2 telescopic legs, 4 brackets, cross brace and crank handle EP-RK1114 - Manual lift for worktop, 2401 3000 mm in length Includes 2 telescopic legs, 5 brackets, cross brace and crank handle WALL MOUNTED WORKTOP - BRACKETS Brackets are the simple solution where it is only occasionally necessary to adjust the height of the worktop or adapt the working layout to a given user. 4 Brackets for worktops can be adjusted in height over a range of 250 mm Height adjustment can be performed by one person alone The lift height is adjusted with a spanner The height is adjusted by loosening a screw on each bracket The vertical section of the bracket is clearly marked with a height indicator, to ease adjustment The distance between two brackets must not exceed 800 mm Maximum load (evenly distributed): 75 kg, including worktop A flexible waste system must be ordered for worktops containing sinks. See page 8. Sinks and hobs should be insulated underneath to prevent burns to thighs and knees. EP-RK1100 - Bracket for worktop 600-1400 mm in length Includes 2 wall fittings and 2 brackets EP-RK1101 - Bracket for worktop Includes 1 wall fitting and 1 bracket EP-RK1100

WALL CUPBOARD LIFTS - ELECTRIC The lifts allow wall cupboards to be moved diagonally, that is both vertically and towards the user. This makes it easy for seated users and children to see and access stored contents. Height-adjustable wall cupboards provide extra storage options where cupboards cannot be installed under worktops out of consideration for seated users. When the wall cupboards are lowered 430 mm to their lowest position, they are also extended 180 mm towards the user The design of the lifts ensures that the lift motors are as discreet as possible, regardless of the cupboard position The lifts are compatible with wall cupboards with a height of 500-704 mm. Adapter kits are available for cupboards with heights outside this range Lift heights for wall cupboards are adjusted via switches in the front worktop edge Operating switches can be placed wherever you want along the front edge Lighting can be installed underneath the safety plates. Lamps should not generate so much heat that they can damage the worktop when the wall cupboard is lowered Maximum load (incl. cupboard): 1 lift motor: 110 kg, 2 lift motors: 220 kg Electric height adjustable wall cupboards should be fitted with a safety plate to prevent crushing injuries. See page 8. When installing above a height adjustable worktop, an interconnection of safety needs to be included (EP-RK1070 or EP-RK1071) See page 8. An optional hand-held control may be purchased as an alternative or supplement to the edge switches. See page 8. For safety reasons, cooking hoods and wall cupboards above a cooking hob should not be adjustable in height. EP-RK1020 EP-RK1020 - Electric lift for wall cupboards, 400-1200 mm in length Diagonally adjustable 430/180 mm Includes 1 lift motor, 2 cross braces and switch EP-RK1021 - Electric lift for wall cupboards, 1201-2400 mm in length Diagonally adjustable 430/180 mm Includes 2 lift motors, 2 cross braces and switch EP-RK1021 5

FREESTANDING WORKTOP LIFTS - ELECTRIC A freestanding electric solution can be a flexible work or dining table. The height of the worktop can be quickly and easily adjusted to the given user or situation. A freestanding worktop can also be used in rooms in which the walls are not strong enough to support the wall-mounted models. Lift heights are adjusted via switches set in the edge or directly under the worktop. The cross brace is delivered to your required measurements, no on-site cutting required Electric lifts for freestanding worktops can be adjusted in height over a range of 300 mm The design of the legs and feet make the table stable and secure, and ensure the lift causes minimal inconvenience to wheelchair users The design of the lift makes it possible to use the worktop from all sides A switch to adjust the height of the worktop can be set into the worktop edge For worktops without an edge, a switch may be mounted under the worktop Maximum load (evenly distributed): 100 kg, including worktop Electric height adjustable worktops should be fitted with a safety bar to prevent crushing injuries. See page 8. For worktops without an edge, safety bars may be mounted directly under the worktop. See page 8. If an edge is fitted under the worktop, this should be as narrow as possible, but must be at least 70 mm to allow room for the height adjustment switches. EP-RK1081 EP-RK1081 - Electric lift for freestanding worktops, 1400-2000 mm. Includes 2 telescopic legs, longitudinal and cross braces and switch. We recommend an overhang of 200 mm at both ends of the table to leave room for wheelchair users. EP-RK1082 - Electric lift for freestanding worktops, 2001-2400 mm. Includes 2 telescopic legs, 2 brackets, longitudinal and cross braces and switch. We recommend an overhang of 400 mm at both ends of the table to leave room for wheelchair users. EP-RK1082 EP-RK1083 - Electric lift for freestanding worktops, 2401-3000 mm. Includes 2 telescopic legs, 2 brackets, longitudinal and cross braces and switch. We recommend an overhang of 400 mm at both ends of the table to leave room for wheelchair users. EP-RK1083 6

FREESTANDING WORKTOP LIFTS - MANUAL A manual, freestanding solution is the budget choice when you need a work or dining table which can be adapted to the given user or situation. A freestanding worktop can also be used in rooms in which the walls are not strong enough to support the wall-mounted models. The cross brace is delivered to your required measurements, no on-site cutting required Manual worktop lifts can be adjusted in height over a range of 300 mm The design of the legs and feet make the table stable and secure, and ensure the lift causes minimal inconvenience to wheelchair users Lifts are adjusted in height using a crank handle The crank handle can be fastened under the worktop when not in use. This keeps the crank handle out of the way, and avoids it being misplaced The crank handle socket can be positioned anywhere along the long sides of the worktop Manual lifts may be used with worktops with or without an edge For worktops with an edge, a cover plate protects the crank handle socket Maximum load (evenly distributed): 100 kg, including worktop For worktops without an edge, a collapsible crank handle may be purchased. See page 8. If an edge is fitted to the worktop, this should be as narrow as possible, but must be at least 100 mm to allow room for the crank handle. EP-RK1181 EP-RK1181 - Manual lift for freestanding worktops, 1400-2000 mm. Includes 2 telescopic legs, longitudinal and cross braces and crank handle. We recommend an overhang of 200 mm at both ends of the table to leave room for wheelchair users. EP-RK1182 - Manual lift for freestanding worktops, 2001-2400 mm. Includes 2 telescopic legs, 2 brackets, longitudinal and cross braces and crank handle. We recommend an overhang of 400 mm at both ends of the table to leave room for wheelchair users. EP-RK1182 EP-RK1183 - Manual lift for freestanding worktops, 2401-3000 mm. Includes 2 telescopic legs, 2 brackets, longitudinal and cross braces and crank handle. We recommend an overhang of 400 mm at both ends of the table to leave room for wheelchair users. EP-RK1183 7

ACCESSORIES WORKTOP ACCESSORIES EP-RK1034 - Lateral safety bar for worktop. Lengths up to 700 mm EP-RK1035 - Safety bar for worktop. Lengths up to 1000 mm EP-RK1036 - Safety bar for worktop. Lengths from 1001 mm 1400 mm EP-RK1037 - Safety bar for worktop. Lengths from 1401 mm 2000 mm EP-RK1038 - Safety bar for worktop. Lengths from 2001 mm 2400 mm EP-RK1039 - Safety bar for worktop. Lengths from 2401 mm 3000 mm EP-RK1040 - Bracket for worktop. Extra bracket for reinforcing heavy worktops or worktops including sink or hob NB: May be used with wall-mounted electric and manual lifts EP-RK1041 - Collapsible crank handle. Crank handle for worktop without a front edge. Can be folded away under worktop. Not visible below worktop EP-RK1043 - Installation cover. Covers and protects flexible waste system EP-RK1044 - Brackets for fitting edge, 4 pieces. The recommended number is 4 for each running metre EP-RK1045 - Hand-held control for lifts for wall worktops and wall cupboards. Cable length: 1600 mm CD-FW40 Flexi waste. To meet the requirements of AS1428 accessible design sinks on height adjustable working surfaces in kitchens and laboratories may have DN 40 fixture discharge pipes (AS/NZ3500.2 Table 6.1 Note 4). WALL CUPBOARD ACCESSORIES EP-RK1043 EP-RK1035 CD-FW40 EP-RK1031 - Safety plate for wall cupboards. Standard depth: 345mm. Lengths up to 1200 mm EP-RK1032 - Safety plate for wall cupboards. Standard depth: 345mm. Lengths from 1201 mm - 2400 mm EP-RK1045 - Hand-held control for lifts for wall worktops and wall cupboards. Cable length: 1600 mm EP-RK1050 - Cable tray for wall-mounted worktop lift, 2000mm. Conceals and protects cables for electric lifts, and shafts for manual lifts NB: Not suitable for freestanding worktops EP-RK1051 - Cable tray for wall cupboard lift, 2000mm. Conceals and protects cables for wall cupboard lifts EP-RK1053 - Light fixture with manual power switch, 340 mm for wall cupboard lifts. Supplied mounted on safety plate EP-RK1031/EP-RK1032 (not incl.) Includes 8W fluorescent tube EP-RK1054 - Light fixture with manual power switch, 555 mm for wall cupboard lifts. Supplied mounted on safety plate EP-RK1031/EP-RK1032 (not incl.) Includes 13W fluorescent tube EP-RK1060 - Mounting kit for cover plates for EP-RK1020. For covering lifts for cupboards under 690mm in height EP-RK1061 - Mounting kit for cover plates for EP-RK1021. For covering lifts for cupboards under 690mm in height EP-RK1065 - Extension fitting for EP-RK1020 lift, 1 pc. For installing cupboards higher than 704 mm EP-RK1066 - Extension fitting for EP-RK1021 lift, 2 pcs. For installing cupboards higher than 704 mm EP-RK1031 EP-RK1045 EP-RK1050 ELECTRICAL ACCESSORIES EP-RK1070 - Interconnection of safety, one lift for worktop and one lift for wall cupboards. Safety bars and safety plates to be ordered separately EP-RK1071 - Interconnection of safety, one lift for worktop and two lifts for wall cupboards. Safety bars and safety plates to be ordered separately EP-RK1072 - Interconnection of safety, two lifts for worktop, without wall cupboards. Safety bars to be ordered separately EP-RK1071 Installations instructions can be downloaded from our website www.enware.com.au/caredesign SPECIALIST PLUMBING SOLUTIONS ADAPTABLE WORK & LIVING SOLUTIONS ENVIRONMENTAL, HEALTH & SAFETY SOLUTIONS STAINLESS STEEL WASHROOM SYSTEMS A DIVISION OF ENWARE 1300 798 744 (aus) WWW.ENWARE.COM.AU/CAREDESIGN info@caredesign.com.au ADDRESS: 9 Endeavour Road Caringbah NSW 2229 Australia postal ADDRESS: P.O. Box 2545 Taren Point NSW 2229 Australia PHONE: 61 2 8536 4000 fax: 61 2 8556 4055 ENW335OCT11