Lutron Stairwell Fixture Solutions

Similar documents
MULTIFAMILY PERFORMANCE PROGRAM Technical Topic New Buildings Savings Opportunity - Stairwell Lighting

PRICE LIST 2015 PR PULSION SYSTEMS

GT Series. Multi-Tenant Entry Security

3M Proptic High-Capacity Optical Distribution Frames

Apeiron LTE+ / E12 Power Box LED Downlight System For Elevators. Installation Guide

TENANT DESIGN MANUAL UPDATED DECEMBER 2018

Page POWER SUPPLIES DIN RAIL MOUNT VERSION Single, two and three phase Output voltage: 24 or 48VDC Output power: W.

adjustable height mechanisms

Vestibule Requirement Intent

TENANT DESIGN MANUAL UPDATED JUNE 2015

LED Lamps. editionfive....life is brighter

International Gas Union Research Conference 2014 Development of New Model Residential PEMFC micro-chp Systems

M8 / M12 CONNECTOR SYSTEM

Large Building Air Leakage Testing

Passive Cooling Measures for Multi-Unit Residential Buildings

TENANT DESIGN MANUAL UPDATED JULY 2015

RIVERSIDE MEDICAL PLAZA

Attic Floor Bedrooms 1 & 2 Family Dwellings

USER MANUAL EN IN Fitness Wristband insportline Ego

SAI distributor with plug in connection hood: SAI-M

TENANT DESIGN MANUAL UPDATED JULY 2015

Request for Proposals. Installment Purchase Contract (Lease/Purchase) Financing for Energy Performance Contract

OPERABLE ALL-GLASS BALCONY GLAZING SYSTEMS. NanaGlass SL25

RoHS. Specifications. Part Number Configurator

An Introduction to the City of Winnipeg s New Zoning By-Law

MANDATORY MEASURES DAYLIGHTING. Reference: Sub-Chapter 4, Section 130.1(d)

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Campbell 508 OPTIONAL BASEMENT DEVELOPMENT SQ.FT. 3 BED 2.5 BATH 2012 FINISHED SQ.FT. FRONT GARAGE HOME TWO STOREY FOR 34 LOTS. MAIN FLOOR 789 sq. ft.

GTSYSTEM Video Multi-Tenant System

S C E P T R E G A T E S H E E T S T R E E T, W I N D S O R

ARLINGTON COUNTY, VIRGINIA

Frequently Asked Questions About 20B Undergrounding Updated on June 17, 2014

CITY OF MOUNT PLEASANT ORDINANCE NO. 1017

Victor Central School District Ontario, Monroe and Wayne Counties, New York (the School District )

TENANT DESIGN MANUAL UPDATED JULY 2015

SECOND FLOOR 1134 sq. ft.

GROUNDING/BONDING SCALE: 1/8" = 1'-0"

CITY OF SPOKANE VALLEY Request for Council Action

Planning&Development Fee Standards

Underfloor. Heating Kits

Frequently Asked Questions About 20A Undergrounding Updated on June 17, 2014

EXTERIOR BRANDING & SIGNAGE PROGRAM. August personasigns.com

TENANT STOREFRONT SIGNAGE CRITERIA

The effect of atrium façade design on daylighting in atrium and its adjoining spaces

Smuggs. Renewal Opportunities / 2016

Re: Parking Study Davenport Road Mixed Use Development

YAVAPAI COUNTY. Development Services

REFLEC TIONS I & II AT CIRCLEPOR T

B. G E N E R A L L A N D L O R D / T E N A N T REQUIREMENTS

DALE COUNTY BOARD OF EDUCATION OFFICE OF SUPERINTENDENT DALE COUNTY GOVERNMENT BUILDING 202 S HWY 123, SUITE E. OZARK, ALABAMA

People, Property and Power Lines. Frequently asked questions about power lines on or near your property

GREEN CORRIDOR PROPERTY ASSESSMENT CLEAN ENERGY (PACE) DISTRICT PROGRAM GUIDELINES. November 17, Version 1.2

Carmel Partners. Retail Tenant Signage. 27 August, In collaboration with:


HOW TO MAKE POSITIVE CHANGE AROUND YOUR APARTMENT BUILDING

HOUSE OF REPRESENTATIVES

Introduction RAI Properties and BURR Plaza

Request Conditional Use Permit (Bulk Storage Yard) Conditional Rezoning (R-10 Residential to Conditional I-1 Light Industrial)

Real Estate & REIT Modeling: Quiz Questions Module 1 Accounting, Overview & Key Metrics

PREAMBLE. That the Gratiot County Zoning Ordinance be amended as follows:

Buying Greener Leases for Government Facilities

A COLLECTION OF SIX 3 BEDROOM HOUSES

TENANT DESIGN MANUAL UPDATED MAY 2016

MODEL WIRELESS TELECOMMUNICATIONS ORDINANCE for Siting of "Small Cell" Telecommunication Infrastructure in Public Rights-Of-Way

Hotel Room Super-pod 4m x 4.8m model

Suite Metering Provisions Under the Residential Tenancies Act, 2006 and the Energy Consumer Protection Act, Consultation Paper

2012 IBC Mixed Occupancies

flexible spaces all the right places... fogg.com ...Euclid Corridor Industrial Mall 1100 East 222nd St., Euclid, Ohio I-90 E. 222 St.

2018 CSBC / 2018 CSFSC Part III. Chapter #10. Means of Egress. Table of Contents. Based on the 2015 IBC and the 2015 IFC.

A PUBLIC RIGHT-OF-WAY MANAGEMENT ORDINANCE BY THE CITY OF SOUTHLAKE, TEXAS; REGULATING THE PHYSICAL USE, OCCUPANCY AND MAINTENANCE

ANHALT RENOVATION + ADDITION Historic Preservation + Multifamily Residential Seattle, WA

CPACE Financing Overview

DRESSING ROOMS. 1x Direct Dial 1x Ethernet Hardline SCREENING ROOM 47 x x Direct Dial Wireless Internet

The Duckhouse sleeps 4 shared bath and shower room. The Workshop sleeps 4 ensuite shower and bath. The Stables sleeps 4 ensuite shower and bathroom

A How- To Guide and Timeline for Municipal Purchase of Street Lights in NYSEG Territory. Benefits and costs of municipal ownership

Screw-Cover, Type 1. Standard Product Screw-Cover Type 1 Pull Boxes with Knockouts

OVERALL SIGN PLAN May 12, 2014

PREMISES & ESTATE DEPARTMENT LOCAL HEAD OFFICE, BANK STREET, KOTI HYDERABAD Phone: Fax: E mail

TENANT DESIGN MANUAL UPDATED FEBRUARY 2017

How to Adopt an Affordable Housing Advisory Committee (AHAC) Report

Interconnection Checklist For Customer-owned Renewable Generation Systems (RGS)

Shoreview Corporate Center

Article 3. SUBURBAN (S-) NEIGHBORHOOD CONTEXT

Chapter MIXED USE ZONING DISTRICTS

Discuss the history of fires that resulted in much of the development of codes related to means of egress. Review mean of egress terminology

SOLAR FOR RENTAL PROPERTIES CASE STUDY REPORT

FLOOR PLANS. 62 GERMANY ISLAND - The Heart of Europe GERMANY ISLAND - The Heart of Europe 63

Submission Procedures

Configuring Service Charge Settlement in Flexible Real Estate Management (RE FX)

TENANT DESIGN MANUAL UPDATED JUNE 2015

Terry E. Poole Principal Agent Emeritus University of Maryland Extension

FOR SALE 20,000+/- Square Foot Industrial Building with 4,000+/- square foot Mezzanine

V-Line Gen5 LTE S2195. Installation Guide

Public Review of the Slot Home Text Amendment

A unique canalside development of contemporary apartments and luxury townhouses.

TENANT DESIGN MANUAL UPDATED JANUARY 2016

Lecture 8 (Part 1) Depreciation

City of High Point Development Fee Schedule

Lone Tree Landing Hillcrest Ave & Lone Tree Way Antioch, CA

14400 Bear Valley Road, Victorville, CA 92392

Transcription:

Lutron Stairwell Fixture Solutions

Lutron Stairwell Fixture Solutions What are stairwell fixture solutions? Stairwell fixture solutions are a family of fixtures that automatically adjusts light output based on stairwell occupancy. These solutions: Utilize a Lutron digital dimming ballast/driver and concealed wireless control (PowPak stairwell controller) to program occupied and unoccupied light levels that are field-adjustable and specific to a project s code requirements Receive signals from Radio Powr SavrTM occupancy sensors (sold separately) via Lutron reliable Clear Connect RF technology Provide the flexibility to determine occupancy sensor quantities, mounting configuration, and placement requirements per the stairwell design Meet building codes and standards Save up to 80% 1 of lighting energy. We offer two different types of stairwell fixture solutions: Stairwell fluorescent fixture The architecturally-designed stairwell fluorescent fixture utilizes T5 or T8 lamps with a concealed wireless control. Stairwell LED fixture The stairwell LED fixture utilizes the same energy saving solution with integral LED's as the light source to significantly lower power usage and maintenance. We also offer a stairwell retrofit kit solution: The stairwell retrofit kit solution is an easy, cost-effective way to add Lutron wireless stairwell solutions technology to your existing stairwell fluorescent fixture. This solution contains Lutron dimming ballasts with pre-wired leads, wireless custom control with wallplate, and optional rapid start sockets. 1 Lutron

Why choose Lutron s stairwell solutions? Because stairwells are often empty, the lighting in them is constantly being wasted. This is a hard issue to address, because codes require stairwells to be lit in case of emergencies. You can cut down on the cost of lighting stairwells with Lutron s stairwell solutions. These occupancy-sensing light fixtures dim the lights in stairwells when they are unoccupied, so that stairwells maintain enough light to meet all regional and ASHRAE codes, but lights are not always full-on. Stairwell solutions are also easy to retrofit, reducing installation time and labor costs. Each solution includes a Lutron dimming ballast and an integrated Lutron wireless control. The stairwell retrofit kit solution is ideal if you want to keep your existing fixture and stairwell layout, but want to cut down on the cost of lighting stairwells. The kit converts any T12, T8, or T5 fluorescent fixture. Radio Powr Savr occupancy sensors (required) Ceiling-, wall-, hall-, and corner-mount configurations available Customize timeout to 1, 5, 15, or 30 minutes Exclusive Lutron XCTTM technology enhanced passive infrared (PIR) sensing Control up to nine fixtures with one sensor* 10-year battery life *Go to lutron.com/rps for required RF range from fixture to sensor Lutron 2

Lutron Stairwell Fixture Solutions How do these solutions work? The easy-to-install stairwell fixture includes a pre-programmed Lutron digital dimming ballast/ driver and wireless control (PowPak stairwell controller). The PowPak stairwell controller receives a radio frequency (wireless) signal from the Radio Powr SavrTM wireless occupancy sensor, via Lutron s reliable Clear Connect RF technology. The dimming ballast/driver then adjusts lights to a preset level based on stairwell occupancy. Unoccupied: 10% light level Occupied: 50% light level 3 3 2 2 1 1 Stairwell fixture Radio Powr Savr occupancy sensor (wall mount) Lutron Clear Connect Wireless Signal Sent Lutron Clear Connect Wireless Signal Received 3 Lutron

Flexible design for various applications Utilize Stairwell Solutions in various applications such as corridors, storage rooms, garages and library stacks. storage restroom restroom stairwell corridor Key Stairwell fixture Radio Power Savr wireless occupancy sensor (wall-mount) Radio Power Savr wireless occupancy sensor (ceiling-mount) Lutron 4

Lutron Stairwell Fixture Solution Benefits Simple installation wireless communication between devices allows the occupancy sensor(s) to be mounted in the location that provides the maximum area of coverage with no need for additional wiring Flexible assign multiple fixtures to a single occupancy sensor, allowing multiple fixtures to adjust to the occupied light level Meets codes and standards ASHRAE 90.1 2010 Additional Control (9.4.1.6) Lighting in stairwells shall have one or more control devices to automatically reduce lighting power in any one controlled zone by at least 50% within 30 minutes of all occupants leaving that controlled zone. IgCC (International Green Construction Code) Interior Light Reduction Controls (609.3) Occupant sensor controls shall be provided to automatically reduce connected lighting power by not less than 45 percent during periods when occupants are not present in all of the following locations. 1. Corridors and enclosed stairwells. 2. Storage and stack areas not open to the public. ADA and BAA compliant All Lutron stairwell fixtures are compliant with the Americans with Disabilities Act. We also offer stairwell fixtures that are manufactured in the U.S., making it easy for you to comply with the Buy American Act and the Buy American provision of the American Recovery and Reinvestment Act. (BAA-compliant stairwell fixtures are available in 2 ft. and 4 ft. models only.) Emergency options An emergency option allows you to use the same fixture for both normal and emergency operation. In the event of a power failure, the emergency ballast or driver switches to emergency mode and operates one or two of the existing lamps. This option is available with all of our stairwell fixture solutions. 5 Lutron

Benefits Return on Investment (ROI) equipment payback as low as 3.5 years; utility rebates available in many locations 2 Energy savings ability to save up to 80% 1 of lighting energy usage high-end trim reduces light levels when occupied occupancy sensing lowers light levels when unoccupied Energy Consumption kwh/yr 5,000 4,500 4,000 3,500 3,000 2,500 2,000 1,500 1,000 500 0 4905 kwh/yr T12 Example: Implementing Stairwell Fixture Solutions in a 4 story building 3 3924 kwh/yr T8 (without Lutron solution) 70% 1467 kwh/yr T8-Controlled (with Lutron solution) energy savings compared to T12 See back cover for sources. Lighting energy analysis and payback study (LEAPS)* The LEAPS tool allows our sales team to quickly customize a stairwell solution and generate a proposal based on a project s budgeted material costs, estimated install cost, energy efficiency performance, and other return on investment metrics. ENERGY STAR Qualified Lutron LED Stairwell fixtures have earned ENERGY STAR for efficiency to help reduce energy costs. When purchasing ENERGY STAR Qualified fixtures, your local power company may provide incentives or rebates to help decrease the initial cost. (See page 7) * Contact your local representative or fixtures@lutron.com for more information. Lutron 6

Lutron Stairwell Fixture Solutions Lower ROI with rebates and incentives! Lutron s stairewell solutions are now ENERGY STAR Qualified to support rebate and incentives offered by utilities. Utilities in almost every state offer rebates for LED lighting. To encourage customers to buy energy efficient products like LED lighting, ENERGY STAR Qualified partners sponsor special offers, such as sales tax exemptions or credits, or rebates on qualified products. Per fixture and sensor incentives are available up to $75/fixture and $50/sensor with an opportunity to significantly improve your ROI. There are two types of rebates: Prescriptive rebates provide a specific predetermined dollar amount for each fixture replaced. Custom rebates are based on the total energy savings for a specific project and are intended to provide rebates for approved fixtures not covered by a prescriptive program. To support rebates and incentive efforts go to the ENERGY STAR rebate finder (www.energystar.com/rebatefinder) and Lutron's dedicated incentive resources shown below. Fixture Rebate and Incentive Sellsheets Lutron Rebate and Incentives Locator www.lutron.com/incentives email: incentives@lutron.com 7 Lutron

Stairwell fixtures and Energi TriPak Stairwell fixtures are also a part of another Lutron energy-saving solution: Energi TriPak. Energi TriPak consists of transmitting devices that send out radio frequency (RF) commands to load controllers. The load controllers receive the RF command and perform the appropriate action based on the information received. Energi TriPak provides the opportunity to use energy-saving solutions in areas other than stairwells, such as conference rooms, private offices, and classrooms. Transmitting devices Sense Radio Powr SavrTM wireless sensors Load controllers Conserve NEW PowPak load controllers Occupancy/vacancy Dimming module with EcoSystem Relay module Contact closure output module Daylight* Adjust Pico wireless control Plug-in dimming module Stairwell fixture Plug-in appliance module Wallmount* Maestro Wireless Tabletop Hand-held Dimmer Switch Tabletop lamp dimmer * Stairwell fixtures and retrofit kits are not compatible with Radio Powr Savr daylight sensors or Pico wireless controls. Lutron 8

Lutron Stairwell Fluorescent Fixture The Stairwell fluorescent fixture is a T5 or T8 fixture available in 2', 4', and 8' models. This solution can save up to 70% 1 of lighting energy and meet building codes and standards. Features and capacities Lutron dimming ballast standard Integral wireless control (PowPak stairwell controller) Frosted Acrylic lens or Opal Acrylic lens 1, 2, or 4 lamps T8, reduced wattage T8, T5HE, or T5HO 120-277 V~ universal input voltage Optional emergency ballast battery backup available Typical applications Stairwells, corridors, hallways Related components (required for the solution to work) Radio Powr SavrTM occupancy sensors (LRF2-OWLB-P-WH) wall (LRF2-OKLB-P-WH) corner (LRF2-OCR2B-P-WH) ceiling (LRF2-OHLB-P-WH) hall Dimensions and mounting 4-foot fixture (standard; shown above) Length: 52.25 in (1327 mm) Height: 3.75 in (95 mm) Width: 3.25 in (83 mm) Can be mounted to wall or ceiling; surface mount 2' and 8' also available Communications and wiring Fixture communicates via Clear Connect RF technology 3-wire control standard 9 Lutron

How to order a stairwell fluorescent fixture Example model number FX SW XX 12 SL 1 14 U 51 SM XX WH 1 2 3 4 5 6 7 8 9 10 11 12 1 Fixture Options Product FX = Fixtures 8 Region U = UL North America B = BAA (Buy American Act) 4 2 3 Family SW = Stairwell Fixture type XX = Standard 9 Control options 51 = 50% Occupied, 10% Unoccupied 82 = 80% Occupied, 20% Unoccupied 4 5 Size 12 = 1' x 2' 14 = 1' x 4' 18 = 1' x 8' Lens options SL = Standard Lens 10 11 Mounting type SM = Surface Mount Options XX = None E1 = T8 Emergency Ballast 5,6 E3 = T5HE Emergency Ballast 5,6 E5 = T5HO Emergency Ballast 5,6 6 Lamps 1 = 1 Lamp 2 = 2 Lamps 4 = 4 Lamps, 8' 12 Color Finish WH = Matte White 7 Lamp type 14 = 14 W T5HE, 2' 17 = 17 W T8, 2' 24 = 24 W T5HO, 2' 28 = 28 W T5HE, 4' 32 = 32 W T8, 4' 54 = 54 W T5HO, 4' RW = 25, 28, 30 W T8 Reduced Wattage, 4' Custom options available contact fixtures@lutron.com. Lutron 10

Lutron Stairwell LED Fixture The stairwell LED fixture provides an energy-saving solution with a concealed wireless control and architectural design. Utilizing integral LEDs as the light source lowers power usage and maintenance, saving up to 80% 1 of lighting energy while meeting building codes and standards. Features and capacities Lutron dimming driver standard Concealed wireless control (PowPak stairwell controller) Frosted acrylic architectural lens Integral 4000K color temperature LED module 120-277 V~ universal input voltage Optional emergency driver battery backup available Typical applications Stairwells, corridors, hallways Related components (required for the solution to work) Radio Powr SavrTM occupancy sensors (LRF2-OWLB-P-WH) wall (LRF2-OKLB-P-WH) corner (LRF2-OCR2B-P-WH) ceiling (LRF2-OHLB-P-WH) hall Dimensions and mounting 4-foot fixture (standard; shown above) Length: 52.25 in (1327 mm) Height: 3.75 in (95 mm) Width: 3.25 in (83 mm) Can be mounted to wall or ceiling; surface mount 2' also available Communications and wiring Fixture communicates via Clear Connect RF technology 3-wire control standard 11 Lutron

How to order a stairwell LED fixture Example model number FX SW XX 12 SL L C1 U 51 SM XX WH 1 2 3 4 5 6 7 8 9 10 11 12 1 Fixture Options Product FX = Fixtures 10 Mounting type SM = Surface Mount (Wall/Ceiling) 2 Family SW = Stairwell 11 Options XX = None E7 = LED Emergency Driver 3 Fixture type XX = Standard 12 Color Finish WH = Matte White 4 Size 12 = 1' x 2' 14 = 1' x 4' 5 Lens options SL = Standard Lens 6 Lamps L = LEDs 7 Lamp type C1* = 17 W, 4000 K, 1500 Lumens C3 = 29 W, 4000 K, 2200 Lumens C4 = 44 W, 4000 K, 3600 Lumens 8 Region U = UL North America 9 Control options 51 = 50% Occupied, 10% Unoccupied 82 = 80% Occupied, 20% Unoccupied * 2 foot only Custom options available contact fixtures@lutron.com. Lutron 12

Lutron Stairwell Retrofit Kit Solution Lutron stairwell retrofit kit solution The stairwell retrofit kit solution allows you to transform high-cost/high-maintenance fluorescent fixtures into energy efficient solutions through the addition of dimming/occupancy sensing capabilities and updating your fixture with more efficient lamps (i.e. T12 to T5). We also group the components you need per fixture together, instead of shipping everything in separate boxes. Kit includes: Pre-wired ballast Wireless control and wallplate Rapid-start sockets (optional) Communications and wiring Stairwell retrofit kit solution (up to three kits per box) Fixture communicates via Clear Connect RF technology with other wireless devices 3-wire control standard Features and capacities Pre-wired Lutron dimming ballast for T8, T5HE, or T5HO lamps Wireless control (PowPak stairwell controller) Wallplate (Claro single gang) Rapid-start sockets (optional) Compatible with 2', 3', 4', or 8' fixtures 1, 2 or 4 lamp options available 120-277 V~ universal input voltage Typical applications Stairwells, corridors, hallways Related components (required for the solution to work) Radio Powr SavrTM occupancy sensors (LRF2-OWLB-P-WH) wall (LRF2-OKLB-P-WH) corner (LRF2-OCR2B-P-WH) ceiling (LRF2-OHLB-P-WH) hall 13 Lutron

How to order a stairwell retrofit kit solution Example model number FXRS SW XX 12 1 14 U 51 XX 1 2 3 4 5 6 7 8 9 Fixture Options 1 Product 7 FXRS = Fixtures Retrofit Kit Solution 2 Family 8 SW = Stairwell 3 4 Fixture type XX = Standard Size 12 = 1' x 2' 13 = 1' x 3' 14 = 1' x 4' 18 = 1' x 8' 9 Region U = UL North America Control options 51 = 50% Occupied, 10% Unoccupied 82 = 80% Occupied, 20% Unoccupied Socket options XX = None SK = Sockets* 5 6 Lamps 1 = 1 Lamp 2 = 2 Lamps 3 = 3 Lamps, T8 4 = 4 Lamps Lamp type 14 = 14 W T5HE, 2' 17 = 17 W T8, 2' 21 = 21 W T5HE, 3' 24 = 24 W T5HO, 2' 25 = 25 W T8, 3 28 = 28 W T5HE, 4' 32 = 32 W T8, 4' 39 = 39 W T5HO, 3' 54 = 54 W T5HO, 4' RW = 25, 28, 30 W T8 Reduced Wattage, 4' * Two rapid-start sockets per lamp; each lamp gets 18" of power leads (white, black) and 40" of lamp leads (yellow, blue) per lamp. Custom options available contact fixtures@lutron.com. Lutron 14

Sources 1 Potential savings for different scenarios listed below. The savings are based on the proposed Lutron solution operating at high end (80% or 50%) for 6 hours a day and low end (20% or 10%) during the remaining hours. Actual savings may vary based on project. Ensure replacement fixture meets the required light levels. Existing (24 Hours of Use) T12-80W T8-64W T8 (50/10%) - 64W 70% 60% Proposed T8 (80/20%) - 64W 60% 50% LED (50/10%) - 44W 84% 80% LED (80/20%) - 44W 80% 75% 2 3.5 year ROI based on a system with one occupancy sensor and two 4 ft T8 stairwell fixtures per floor. Payback based on an electricity rate of 15 cents/kwh including a utility rebate of $50/fixture. 4ft LED stairwell fixture ROI is 5.2 years with same assumptions. For more information on utility rebates, visit www.lutron.com/incentives. 3 4 5 6 Example assumes 7 landings in a 4 story building. The T12 fixture (80W) is assumed to operate 8760 hours at full output. The T8 fixture (64W) without a Lutron solution is assumed to operate 8760 hours at full output. The T8 fixture (64W) with a Lutron solution is assumed to operate for 2190 hours (25% occupancy) at 50% of full output, and at 10% of full output during the remaining hours. Ensure replacement fixture meets the required light levels. Lutron offers stairwell solutions that are manufactured in the United States, making it easy for you to comply with the Buy American Act (BAA) and the Buy American provision of the American Recovery and Reinvestment Act (ARRA). BAA-compliant stairwell fixtures are available in 2' and 4' models only. Emergency ballast option not available if 2 lamp type is chosen. Emergency ballast option is determined by lamp type. www.lutron.com/fixtures Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 World Headquarters 1.610.282.3800 Technical Support 1.800.523.9466 (Available 24/7) Customer Service 1.888.LUTRON1 (1.888.588.7661) 09/2013 Lutron Electronics Co., Inc. I P/N 367-2370 REV B