COMPARISON OF SAMPLING METHODS FOR AIR TIGHTNESS

Similar documents
The Impact of Using. Market-Value to Replacement-Cost. Ratios on Housing Insurance in Toledo Neighborhoods

Dwelling air-tightness in a 55 years old estate

NFPA (2012). In a high-rise building, stairwell pressurization systems typically utilize multiple fans distributed over the height of the stair, a duc

Housing affordability in England and Wales: 2018

Rents in private social housing

The effect of the wind speed velocity on the stack pressure in medium-rise buildings in cold region of China

Rockwall CAD. Basics of. Appraising Property. For. Property Taxation

Stat 301 Exam 2 November 5, 2013 INSTRUCTIONS: Read the questions carefully and completely. Answer each question and show work in the space provided.

MULTIFAMILY WEATHERIZATION FREQUENTLY ASKED QUESTIONS

Available online at ScienceDirect. Energy Procedia 78 (2015 )

A STUDY ON AN ESTIMATION METHOD OF THE EFFECTIVE OPENING AREA OF ENTRANCE DOORS AND WINTER AIRFLOW RATE INTO ATRIUM BUILDINGS

How to implement a mandatory inspection in accordance with European directives: The example of certified workshops

Measuring Air Change Rates using the PFT Technique in Residential Buildings in Northern Portugal

Residential Air Leakage Testing and Mechanical Ventilation Verification

Washington Department of Revenue Property Tax Division. Valid Sales Study Kitsap County 2015 Sales for 2016 Ratio Year.

Residential Air Leakage Testing and Mechanical Ventilation Verification

Ashland Transit Triangle:

Past & Present Adjustments & Parcel Count Section... 13

Introduction. Bruce Munneke, S.A.M.A. Washington County Assessor. 3 P a g e

Maratonvägen 36. Project summary. Energy concept: To achieve a substantial reduction of the energy losses.

Technical Description of the Freddie Mac House Price Index

Energy variations in apartment buildings due to different shape factors and relative size of common areas

Chapter 35. The Appraiser's Sales Comparison Approach INTRODUCTION

Large Building Air Leakage Testing

Housing Needs Survey Report. Arlesey

An Assessment of Current House Price Developments in Germany 1

UNITED KINGDOM OCCUPANCY SURVEY. Serviced Accommodation Annual Report May the research solution

M A N N E S M A N N A.S / REAL ESTATE AND PROJECT APPRAISAL REPORT Bodrum/MUĞLA

How Severe is the Housing Shortage in Hong Kong?

Where rivers connect

SURVEY OF LAND AND REAL ESTATE TRANSACTIONS IN THE RUSSIAN FEDERATION REGIONAL REPORT: IRKUTSK OBLAST

Content. An Introduction to FmK ECOHomes

High-Rise Fire Sample Scenario with Stairwell Pressurization by Steve Kerber Fire Engineering Simulation

Initial sales ratio to determine the current overall level of value. Number of sales vacant and improved, by neighborhood.

SURVEY OF LAND AND REAL ESTATE TRANSACTIONS IN THE RUSSIAN FEDERATION REGIONAL REPORT: NOVGOROD OBLAST

2013 Profile of Home Buyers and Sellers Metro Indianapolis Report

Operational Costs. Introduction. Operational Costs in Germany. Jordan Milewicz,

General Market Analysis and Highest & Best Use. Learning Objectives

MARKHAM. City of. Comprehensive Zoning By-law Project. Task 4b. Review and Assessment of Minor Variances

DEMAND FR HOUSING IN PROVINCE OF SINDH (PAKISTAN)

Elements for an acoustic classification of dwellings and apartment buildings in France C. Guigou-Carter, R. Wetta, R. Foret, J.-B.

Study of the energy performance of Korean apartment buildings with alternative balcony configurations

Use of Comparables. Claims Prevention Bulletin [CP-17-E] March 1996

World Renewable Energy Congress (WRECX) Editor A. Sayigh 2008 WREC. All rights reserved. 822

CENTRAL GOVERNMENT ACCOUNTING STANDARDS

Performance of the Private Rental Market in Northern Ireland

2011 ASSESSMENT RATIO REPORT

Journal of Babylon University/Engineering Sciences/ No.(5)/ Vol.(25): 2017

A Quantitative Approach to Gentrification: Determinants of Gentrification in U.S. Cities,

History & Theory Architecture II

Keywords: criteria of economic efficiency, governance, land stock, land payment, land tax, leasehold payment, leasehold

Passive Cooling Measures for Multi-Unit Residential Buildings

IREDELL COUNTY 2015 APPRAISAL MANUAL

GENERAL ASSESSMENT DEFINITIONS

Chapter III THE HOUSING STOCK

Indoor climate of an unheated apartment and its impact on the heat consumption of adjacent apartments

STEVEN J. DREW Assessor OFFICE OF THE ASSESSOR Service, Integrity, Fairness, Internationally Recognized for Excellence

Available online at ScienceDirect. Energy Procedia 78 (2015 )

UNITED KINGDOM OCCUPANCY SURVEY. Serviced Accommodation Summary Report March the research solution

ELECTRICAL LOAD CHARACTERISTICS OF SUPERINSULATED MULTIFAMILY HOUSING: A CASE STUDY

UK OCCUPANCY SURVEY FOR SERVICED ACCOMMODATION JANUARY 2011

1. Introduction and reading guide Purpose of the inspection The inspection period Requirements for the inspection...

An Examination of Potential Changes in Ratio Measurements Historical Cost versus Fair Value Measurement in Valuing Tangible Operational Assets

Australian home size hits 20-year low

The role of policy in influencing differences between countries in the size of the private rented housing sector Professor Michael Oxley 26/2/14

STEVEN J. DREW Assessor OFFICE OF THE ASSESSOR Service, Integrity, Fairness, Internationally Recognized for Excellence

The IRAM Web app. Description of the internet application of the Integrated Risk Assessment Method (IRAM)

The future development of Post War Single-Family Housing Estates in Germany

On Smoke Control by Pressurization in Stairwells and Elevator Shafts

Residential Real Estate, Demographics, and the Economy

ASSESSORS ANSWER FREQUENTLY ASKED QUESTIONS ABOUT REAL PROPERTY Assessors Office, 37 Main Street

Australian home size hits 22-year low

Policy Choices to Promote and Support Energy Efficiency in Housing Buildings. Claude Taffin (DINAMIC) Washington D.C., May

On Smoke Control by Pressurization in Stairwells and Elevator Shafts

Earls Barton. Rural Housing Survey. Authors: A Miles & S Butterworth Date: October 2012

Economic and monetary developments

The impact of the global financial crisis on selected aspects of the local residential property market in Poland

Sales Ratio: Alternative Calculation Methods

Compatible-Scale Infill Housing (R-2 Zones) Project

A. K. Alexandridis University of Kent. D. Karlis Athens University of Economics and Business. D. Papastamos Eurobank Property Services S.A.

Heathrow Expansion. Land Acquisition and Compensation Policies. Interim Property Hardship Scheme. Policy Terms

Chapter 13. The Market Approach to Value

D DAVID PUBLISHING. Mass Valuation and the Implementation Necessity of GIS (Geographic Information System) in Albania

UNITED KINGDOM OCCUPANCY SURVEY. Serviced Accommodation Summary Report April the research solution

The private rented housing sector: The UK and ideas from other countries

Metro Boston Perfect Fit Parking Initiative

Is there a conspicuous consumption effect in Bucharest housing market?

A statistical system for. Residential Property Price Indices. David Fenwick

White Paper of Manuel Jahn, Head of Real Estate Consulting GfK GeoMarketing. Hamburg, March page 1 of 6

Residential New Construction Attitude and Awareness Baseline Study

Assessment-To-Sales Ratio Study for Division III Equalization Funding: 1999 Project Summary. State of Delaware Office of the Budget

ECONOMIC AND MONETARY DEVELOPMENTS

Luxury Residences Report First Half 2017

Assessment Quality: Sales Ratio Analysis Update for Residential Properties in Indiana

The Improved Net Rate Analysis

Status of HUD-Insured (or Held) Multifamily Rental Housing in Final Report. Executive Summary. Contract: HC-5964 Task Order #7

Thermo-renovation: Opportunities & Barriers Experience of Latvia

Utilizing 3D Building and 3D Cadastre Geometries for Better Valuation of Existing Real Estate

Classification: Public. Heathrow Expansion. Land Acquisition and Compensation Policies. Interim Property Hardship Scheme 1.

Multi-Paths of Colleges Performance Appraisal and Comparison Hui PENG 1,a, Lian-Sen WANG 2,3,4,b,*

Transcription:

COMPARISON OF SAMPLING METHODS FOR AIR TIGHTNESS MEASURMENTS IN NEW FRENCH RESIDENTIAL BUILDINGS B. Moujalled 1 ; F. Richieri 1 ; R. Carrié 2 ; A. Litvak 3. 1: CETE du Sud-Ouest, Rue Pierre Ramond, CS 60013, 33166 Saint-Médard-en-Jalles Cedex 2: INIVE, Lozenberg 7, BE-1932 Sint-Stevens-Woluwe 3: CDPEA, 58 rue Jean Duvert, Ecoparc, Le Fiducia, 33295 Blanquefort Cedex andres.litvak@cdpea.fr ABSTRACT With the increasing need for higher energy efficiency in buildings, thermal regulations are evolving toward more stringent rules in buildings at the European and national level. In France, new constructed buildings will have to comply with mandatory regulations that promote low-energy buildings from 2012 and positive-energy at the horizon of 2020. In this context, air tightness becomes a major performance issue in buildings. In fact, the part of heat loss due to air leakage in well insulated buildings becomes more important. Besides, air leakage can lead to cold draught and construction pathologies. The French thermal regulation sets a compliance scheme to guaranty good air tightness in new constructed buildings based on the evaluation of the overall building air tightness, through field measurements. However, there are often practical, technical and economical limitations to measure the global air tightness in large or multi-family buildings. In this case, building air tightness is evaluated through partial measurements in few apartments of the building using a sampling method. This method does not account for the leakages in the untested zones, including other apartments, halls, stairwells, etc. Actually, a research project (MININFIL) associating national institutions, research laboratories, resource centres and building professionals is conducted in France in order to enhance the knowledge on the air tightness and its impact on the energy performance in buildings, and to support building professionals to achieve much better envelope air tightness. MININFIL includes a campaign of air tightness measurements in ten residential buildings in order to identify the sampling methods that characterize the air tightness of a whole building through limited set of measurements in apartments, hall, stairway, etc. This paper presents a bibliographical review of the sampling methods followed by the measurement campaign that was carried out in ten new buildings. In each building, the air tightness was measured on the whole building and in each apartment of the building. The results have served to identify the typical air leakage paths, and the appropriate sampling method for the air tightness evaluation in large residential buildings. INTRODUCTION As recommended by the EPBD, the new French thermal regulation imposes that new constructed buildings must be low energy buildings from 2012. Different studies have shown that the impact of the infiltration losses becomes more important on the energy efficiency in the case of high performance buildings [1, 2]. Therefore, air tightness requirements have been included in the French regulation with an obligation for air tightness measurements in residential buildings, especially in multi-family buildings.

The European standard EN ISO 13829 [3] describes the measurement method of air permeability of buildings. This measurement is planned to be done on the whole building. In the case of multi-family buildings, there are often practical limitations to measure the air permeability of the whole building (main reasons: building is too large, floors are not connected with an internal airflow path, or very leaky elements in the stairway). For these buildings, the standard allows separate measurements on individual parts of the building; e.g. apartments of multi-family buildings can be measured individually. In many European countries, the measurement is done on a sample of apartments for practical and technical reasons. A sampling method is given to specify the sample size, the selection criteria, and the airtightness requirements for the sample. Walther [2] has presented a review of the different sampling methods in Europe. Table 1 gives the German, UK, and French methods. The French sampling method has been included in the EN ISO 13829 implementation guide [4]. Sampling Method Germany UK France (GA P50-824) Sample size At least 20% of the total number of apartments At least 20 % of the buildings envelope area = 3 apartments if the building has 30 units or less = 6 apartments otherwise Selection criteria Apartments located at the top, in-between and ground floor. Areas representative of the whole envelope construction. 1. Apartments with the largest length of floors and windows. AND 2. Apartments located at the top, in-between and ground floor. Extrapolation method for the whole building 1. The weighted average based on the volume must be lower than the limit value. 2. Air permeability of tested apartments can be 30% greater than the limit value. 1. Air permeability of tested apartments must be 10% smaller than the limit value. 2. No requirements for the whole building. 1. The weighted average based on the envelope area must be lower than the limit value. 2. No requirements for the tested apartments. Table 1: The sampling methods for the air tightness measurements in multi-family buildings. In France, the research project MININFIL has been conducted since 2008 in order to enhance the knowledge of professionals on the air tightness and its impact on the energy performance in buildings. Under the task 3 of the project, an extensive campaign of airtightness field measurements has been carried out in ten new multi-family buildings. In each building, the air tightness was measured for all the apartments and for the whole building. The results have enabled the evaluation of the sampling methods for the measurement of airtightness in mutifamily buildings. This paper presents the results of this work. METHOD The air permeability measurements have been realised with the fan pressurisation method according to the standard EN ISO 13829 [3] using Minneapolis Blower Door systems. The aim of the measurements is to identify separately the air permeability of each apartment, the common areas, and the whole building. Therefore, three types of air permeability measurements have been carried out in each building:

1. Individual measurements of each apartment of the building with a blower door positioned on the entrance door of the apartment. The entrance door of the building is fully opened. 2. A global measurement of the whole building, including leakages in apartments and common areas. This measurement is realised with a blower door using a single or double fans. The blower door is positioned on the entrance door of the building. The doors between apartments and common areas are fully opened 3. A measurement of the common areas. This measurement is similar to the previous, but this time the doors between apartments and common areas are closed, in order to eliminate the leakage in apartments from the measurement. This requires that the doors are air-tight. Table 2 presents the multi-family buildings characteristics. The number of apartments per building varies between 12 and 38, and the number of the levels between 2 and 7. The volume of buildings varies between 2365 m 3 and 5704 m 3, with 2 buildings larger than 4000 m 3. Building code B01 B02 B03* B04 B05* B06 B07 B08 B09 B10 # of levels 4 3 2 4 3 5 5 4 7 5 # of flats 17 12 17 20 16 17 17 16 38 36 Area (m²) 1325 956 1266 1486 1150 1455 1248 1375 2256 2246 Volume (m 3 ) 3280 2365 3150 3700 2893 3544 3446 3031 5704 5175 Table 2: The description of the assessed buildings. The measurements have been done at the end of the building construction. All apartments were unoccupied, in order to facilitate the access to all the parts of the building. However, the global measurements of buildings B03* and B05* have been disturbed by the presence of workmen during the tests. The global measurements for these building will not be considered in the analysis. RESULTS In France, the air permeability (Q 4Pa-Surf ) is calculated as the ratio between the infiltration airflow rate at 4 Pa with the envelope area of the building except the floors area (A T bat ). The new thermal regulation sets the limit value required of air permeability to 1.0 m 3 /h/m 2 for the case of multi-family buildings. This value is based on the French low-energy building standard. In this paper, the results will be presented with the French air permeability indicator. The ten buildings represent a total of 208 apartments. For the individual measurements, more than half of the apartments (52%) show lower results than the limit value 1.0 m 3 /h/m 2. For the global measurement of the whole buildings, only three buildings (over eight) are lower than the limit value. The major part of the leakage in the apartments (40%) has occurred across the fenestration (joints at window sash, window sill, and shutter box), while 30% of the leakage occurs at the joints of hatch and ducts, and 25% across the electricity plugging. The leakage across the joints between walls and slabs are negligible. Figure 1 presents the results of the individual and global measurements for each building. We can observe that the individual measurements of air permeability are very heterogeneous between buildings, and between apartments in the same building in some cases. The buildings can be classified into two categories: Buildings B05*, B06, B07 and B08 having the global measurement and the individual measurements globally below the required limit value (1.0 m 3 /h/m 2 ). For these buildings, the individual measurements are uniform and vary in a narrow range.

For the other buildings, both the global measurement and the median of the individual measurements are greater than the limit value. The individual measurements in each building are very heterogeneous and vary in a wide range. In B09, the upper value of the individual measurements is almost ten times greater than the lower value. Figure 1: Box plot of the measured air permeability values in each building: the box lines indicate the statistic results of individual measurements and the red marks indicate the global measurement of the whole building in each case. The global measurements of B03* and B05*have been excluded. In order to evaluate the sampling methods, the GA P50-784 method has been tested and compared to the results of the measurements. Table 3 presents a comparison of the GA P50-784 method with other methods in terms of the sample size criterion. Only one building has a sample with more than 20% of the total number of apartments as required by the German method [2]. Whereas, 7 buildings have samples with more than 20% of the building envelope as required by the UK method. This can be explained by the fact that the selection criterion of the GA P50-784 method privileges the apartments with the largest envelope areas. Building code B01 B02 B03* B04 B05* B06 B07 B08 B09 B10 # of flats 17 12 17 20 16 17 17 16 38 36 # of tested flats 3 3 3 3 3 3 3 3 6 6 % of tested flats 18% 25% 18% 15% 19% 18% 18% 19% 16% 17% % of tested A T bat 20% 22% 22% 20% 29% 21% 18% 24% 19% 16% Table 3: Comparison of the GA P50-784 sampling method against the other methods. The left panel of Figure 2 presents a comparison between the weighted average air permeability of the sample of apartments and the weighted average of all the apartments for each building. For the buildings with uniform individual measurements lower than the limit value (B05*, B06, B07, and B08), the results of the samples are very close to those obtained with all the apartments. For the other buildings, the difference is more significant. This figure gives also the statistical values of the weighted average air permeability that can be obtained with the different possible random samples of apartments for each building. The

random samples are selected according to the required size of the sampling method with the apartments being at the top, in-between and ground floors. The median values are globally close to the weighted average of all the apartments. For buildings B01, B02, B04, B09 and B10, the difference between the minimal and maximal values that can be obtained with a random sample is very important. The minimal values can be as low as the half of all the apartments in the case of B10. The sample size and the selection criterion are critical for the sampling method. Figure 2: Comparison of the weighted average air permeability of the samples of apartments against the weighted average air permeability of all apartments on the left panel, and against the global measurement of whole building on the right panel. The GA P50-784 method evaluates the air permeability of the whole building through the weighted average of the sample of apartments. Besides it doesn t impose any requirement on the individual measurements. The use of a selection criterion is important to guarantee that the air permeability of the sample is at least equivalent to all the apartments. The GA P50-784 method uses the ratio of the length of floor and windows per unit of floor area as a selection criterion. The method selects the apartments with the largest value of this ratio, as they are considered to be potentially the leakiest apartments. Figure 3 shows on the right panel the variation of the air leakage rates at 4 Pa against this ratio. As we can see, there is no correlation between these two parameters, and besides the air leakage rate shows a decreasing tendency with this ratio. The correlation is more significant with the envelope area as we can see on the right panel of figure 3. The envelope area seems to bee more relevant as a selection criterion than the ratio of the length of floor and windows per unit of floor area. Now we will compare the results of individual measurements against the global measurement. The right panel of Figure 2 presents the comparison of the weighted average air permeability of the samples of apartments (the sample of GA P50-784 method, and the sample of all the apartments) against the global measurement of the whole building. For both samples, the weighted average air permeability of apartments is always lower than the air permeability of the whole building as it doesn t account for the leakage in the common areas caused by the lift shaft, the parking basement and other shafts and hatches. The greatest difference was found in the case of buildings B08, B09 and B10 with lift shaft and basement parking in the common areas.

Figure 3: The variation of the measured air leakage rates at 4 Pa as a function of the sampling criteria (the GA P50-784 sampling criteria on the left panel and the envelope area excluding floor on the right panel). CONCLUSION A detailed campaign of air permeability measurements has been carried out in ten multifamily buildings in France. For each building, the air permeability of individual apartments and the whole building have been measured, and the sampling method of the implementation guide GA P50-784 has been evaluated. The results showed that the sampling method gives good results only in the case of buildings with uniform individual measurements. The method is as good as a random sampling. Nevertheless, in the case of buildings with heterogeneous individual measurements, the result of a random sampling varies in a very wide range. The selection criterion of the GA P50-784 sampling method doesn t identify the apartments with greater risk of leakage. The use of another criterion based on the envelope area can be more relevant. The results have shown that the leakage in the common areas are significant and can have an important impact on the air permeability of the whole building in the case of common areas with lift shaft and basement parking. These leakages should be considered in the measurement method if it extrapolates the individual measurements to the whole buildings. ACKNOWLEDGEMENTS This work has been conducted under the task 3 of the research project MININFIL that is financed by the French Mininstry of Housing and the French Agency for the Energy Efficiency and the Environment ADEME. REFERENCES 1. Erhorn-Kluttig, H, Erhorn, H, Lahmidi, H: Airthightness requirements for high performance building envelopes. ASIEPI information paper #157, 2009. 2. Walther, W, Rosenthal, B: Airtightness testing of large multi-family buildings in an energy performance regulation context. ASIEPI information paper #165, 2009. 3. NF EN 13829 : February 2001 - Thermal performance of buildings - Determination of air permeability of buildings - Fan pressurization method. 4. GA P50-784 : February 2010 Thermal performance of Buildings Implementation guide for NF EN 13829 : 2001.