By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Similar documents
TIN KNOCKER TK BAR FOLDER INSTRUCTIONS & PARTS DIAGRAM TK BAR FOLDER

Saf-T-Bar Conductor Bar C Series

RSIC-1 EXT04 INSTALLATION GUIDE

TRAMPOLINE LADDER. 250 Lbs 113 Kgs MODEL# 9200TL PRODUCT MANUAL - VERSION Do not use ladder if children under 6 years of age are nearby.

NOTE: HEIGHT WIDTH OF UNOBSTRUCTED OPENING MUST EQUAL AT LEAST 5.7 SQ. FT.

INSTRUCTION MANUAL MM-601J. Series FS4-3 General Purpose Liquid Flow Switch

NJAA Guidance on Child Protective Window Guards

THIS CHECKLIST HAS BEEN AMENDED TO INCLUDE ONLY LEVEL ONE CRITERIA AS REQUESTED BY TIR REAL PROPERTY. As such it does not form a complete Checklist.

Allison 1000, 2000, 2400 series ( ) Installation Guide

Clubhouse User Manual

CITY OF MOUNT PLEASANT ORDINANCE NO. 1017

Hellan Strainer Installation & Operations Manual Hellan Strainer Manual Self-Cleaning Strainers

PMD DRIVER RELOCATION KIT For Chevy 6.5L Diesel Trucks

Secondary Suites Changes between the 2006 ABC and the 2014 ABC Requirements

M ake sure that you have all the parts as listed on the packing slip. Verify that all blocking has been installed in the locations required.

2014 OSSC CHAPTER 10 - MEANS OF EGRESS TABLE OF CONTENTS

Housing Authority of the County of San Bernardino

Lead Safe Renovation Specifications Chase Street Cincinnati, Ohio Year of Construction: 1900

DAMMERON VALLEY LANDOWNERS ASSOCIATION ARCHITECTURAL GUIDELINES [May, 2010] PREFACE

Lone Tree Landing Hillcrest Ave & Lone Tree Way Antioch, CA

Discuss the history of fires that resulted in much of the development of codes related to means of egress. Review mean of egress terminology

Product Terms, Conditions & Warranty

NORTHROP GRUMMAN CORPORATION

PREAMBLE. That the Gratiot County Zoning Ordinance be amended as follows:

Does the Building Code Apply to Mobile Homes?

MASTER SIGN PROGRAM SERRA CENTER COLMA, CALIFORNIA. Approved by the Town of Colma City Council on March 22, 2017

TENANT DESIGN CRITERIA Section s Signage Updated: March 2018

ARTICLE 11. NAMEPLATES AND SIGNS Signs in all districts.

Residential Accessible, Type A, and Type B Dwelling Unit Requirements 2012 International Building Code and 2009 ICC/ANSI A117.1

1.0. Picket Gates. Vinyl Fence Framed Gate Kits BOM V1 1/14. Owner's Manual Assembly and Installation Instructions.

CHAPTER 154: SIGNS. Section

Oil-Free Centrifugal Chiller

NADA MANUFACTURED HOUSING COST GUIDE FANNIE MAE 1004C FREDDIE MAC 70B

QUALITY REQUIREMENTS SELLER QUALITY REQUIREMENTS

GENERAL TERMS AND CONDITIONS OF SALE. December 2010

TABLE OF CONTENTS. 1.1 Official Title Effective date Authority

NADA MANUFACTURED HOUSING COST CD-ROM FANNIE MAE 1004C FREDDIE MAC 70B

CHAPTER 13 SIGNS 13-1

Screw-Cover, Type 1. Standard Product Screw-Cover Type 1 Pull Boxes with Knockouts

VINEYARD & VENTURA SHOPPING CENTER

MONTEBELLO CONDOMINIUM Maintenance Responsibilities

USER MANUAL EN IN Table Tennis Table insportline Rokito

USER MANUAL EN IN Portable Basketball System insportline Phoenix

FENCE and or POOL BARRIER CHECKLIST

Kvadrat Soft Cells Installation guide

RULES AND REGULATIONS OF MARTIN COUNTY WATER AND SEWER DISTRICT NO. 1. C. Metering Individual Trailers in Mobile Home Parks

Composition of traditional residential corridors.

SIGNS MASTER SIGN PROGRAM

Potential Conditions of Approval for Marion County Land Use Decisions

Pool Enclosure Permit Application

I hereby declare, by my initials below, and certify to each of the 8 following declarations:

3- Should the Taxpayer charge sales or use tax on charges for the installation and/or repair of signs and awnings?

Article 18. Sign Regulations

Mae 1004C and Freddie Mac 70B

CHAPTER 10 SIGN REGULATIONS

Quality Control Biennual Inspections B. INITIAL HQS INSPECTION [24 CFR (a) (b) (2)] Timely Initial HQS Inspection The PHA will inspect

00usp005 (Preston Walk) Page 1 of 10

Example for a Single Family Home Annual Application fee: $50.00 Inspection fee $ (required once every four years) Total fee: $185.

TIN KNOCKER FOURPLEX CLEAT FORMER

Vestibule Requirement Intent

The Following Guidelines are to be used in conjunction with the Deed Restrictions for Rotonda West.

QUESTION: Whether Taxpayer s sales are retail sales of tangible personal property?

HOW TO CREATE AN APPRAISAL

City of Coral Gables. Historic Preservation Ad-Valorem Tax Exemption Program

The New NYC Building Code Chapter 11 Accessibility. New York City Department of Buildings. Technical Affairs. Keith Wen, R.A. Copyright Materials

Section XXIV Signs (including Banners, Flags, and Temporary Signs)

CHAPTER VIII 1 PERMIT REQUIREMENTS FOR RETAINING TANKS

Revised Reroof Checklist

SUPPLIER TERMS AND CONDITIONS

SHIAWASSEE COUNTY ZONING ORDINANCE Article 4 Specific Use Regulations

No sign shall interfere with vehicular or pedestrian safety in any manner.

Caliber Aero s Terms and Conditions for Purchase Orders Rev

ELECTRONIC COMMERCE TRADING PARTNER AGREEMENT (Dated 10 November 2016)

ADAPTABLE DESIGN GUIDELINES

Ported Fuel Rail Fitting GM 6.6L Duramax LLY/LBZ/LMM

Sign, Canopy: A sign attached to the underside of a canopy.

SOLAR POWER INSTALLATION AND MAINTENANCE AGREEMENT

THE CORPORATION OF THE TOWN OF EAST GWILLIMBURY BY-LAW 2016-

C-1000 Screen Coater

Appendix1,Page1. Urban Design Guidelines. Back to Back and Stacked Townhouses. DRAFT September 2017

MANDATORY MEASURES DAYLIGHTING. Reference: Sub-Chapter 4, Section 130.1(d)

REQUEST FOR PROPOSALS HYDRAULIC ELEVATOR MODERNIZATION

APPLICATION FOR A SWIMMING POOL ENCLOSURE PERMIT

HIPOWER LOAD CENTER DESCRIPTION

Equipment Lease Extension Agreement

PROPERTY CONDITION CHECK LIST FOR A LICENCED HMO

IOSCO TOWNSHIP ZONING ARTICLE 11 SIGNS

Electrical Safety Statutes and Regulations May 2018 Labor Standards and Safety Division Mechanical Inspection

USER MANUAL EN Trampoline Froggy PRO Safety Net

Information contained

Rule 21 STANDARDS OF PRACTICE FOR SURVEYING

DECK PORCH PATIO RAMPS & HANDRAILS - AWNINGS

Bylaw as follows: the zone in. type in of a sign, continue. such work hazard met. liable:

NET METERING INTERCONNECTION AGREEMENT FOR CUSTOMER-OWNED RENEWABLE GENERATION SYSTEMS

Standards of Performance

SUBJECT: Unacceptable Assignment Conditions in Real Property Appraisal Assignments

APPLICATION FOR A SWIMMING POOL ENCLOSURE PERMIT

Q16 - Engineering Directed Standard Tool/Perishable Tool Inspection Requirements

Quality Clause Q16. Engineering Directed Standard Tool/Perishable Tool Inspection Requirements

Has the Registrar s Office required you to write the Admission Test? This happens when:

Transcription:

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has been duly INCORPORATED BY REFERENCE and shall be considered legally binding upon all citizens and residents of the United States of America. HEED THIS NOTICE: Criminal penalties may apply for noncompliance. e Document Name: AAMA 1704: Voluntary Standard Egress Window CFR Section(s): Standards Body: Systems for Utilization in Manufactured-Housing 24 CFR 3280.404(b) American Architectural Manufacturers Association Official Incorporator: THE EXECUTIVE DIRECTOR OFFICE OF THE FEDERAL REGISTER WASHINGTON, D.C.

Voluntary Standard Egress Window Systems for Utilization in Manufactured Housing AAMA 1704-85

TABLE OF CONTENTS 1. GENERAL REQUIREMENTS...1 1.1 Introduction...1 1.2 Scope and Purpose...1 1.3 Definitions...1 2. REQUIREMENTS...2 2.1 Installation...2 2.2 Performance For Primary Windows Used in Egress system...2 2.3 Dimensions...2 2.4 Operational...2 3. APPURTENANCES...3 3.1 Dimensional Requirements...3 3.2 Mechanism Requirements for Non-Operable Appurtenances...3 3.3 Non-Removable Appurtenance...4 3.4 Appurtenance Instructions...4 3.5 Integral Rolled-in Screen...4 4. TEST METHODS...4 4.1 Test Method A - Minimum Dimensions...4 4.2 Test Method B - Minimum Area...4 4.3 Test Method C Operating Forces...4 4.4 Test Method D - Mechanical Device Operating Force (Appurtenances)...5 5. TEST REPORT...5 5. 1 Exclusions...5 6. CERTIFICATION...5 7. EVIDENCE OF COMPLIANCE...5 8. INSTALLATION INSTRUCTIONS...5 APPENDIX...6 MANUFACTURED HOME EGRESS WINDOW SYSTEM INSTALLATION INSTRUCTION...8 1. SPECIAL INSTRUCTIONS AND REQUIREMENTS...8 2. ROUGH OPENING OPERATION...8 3. WINDOW INSTALLATION...9 AAMA. The Source of Performance Standards, Products Certification and Educational Programs for the Fenestration Industry. All AAMA documents may be ordered at our web site in the Publications Store. 1985 American Architectural Manufacturers Association These printed or electronic pages may NOT be reproduced, republished or distributed in any format without the express written consent of the American Architectural Manufacturers Association. This document was developed and maintained by representative members of AAMA as advisory information. AAMA DISCLAIMS ALL WARRANTIES WITH REGARD TO THIS INFORMATION, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL AAMA BE LIABLE FOR ANY DAMAGES WHATSOEVER FROM THE USE, APPLICATION OR ADAPTATION OF MATERIALS PUBLISHED HEREIN. It is the sole responsibility of the user/purchaser to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content published herein.

VOLUNTARY STANDARD EGRESS WINDOW SYSTEMS FOR UTILIZATION IN MANUFACTURED HOUSING 1. GENERAL REQUIREMENTS 1.1 Introduction This standard is for use in establishing performance criteria for egress systems for use in manufactured housing construction. While other egress systems, not incorporating windows may qualify as approved devices, this standard is 1imited to uti1ization of egress window systems. 1.2 Scope and Purpose The purpose of this section is to establish the requirements for the design, construction and installation of windows and approved devices intended to be used as an emergency exit during conditions encountered in a fire or similar disaster. A "primary window" and designated "appurtenances" together with the necessary operating instructions constitute an "Egress Window System." 1.3 Definitions 1.3.1 Approved Appurtenance An appurtenance in place with the primary component of the egress system at the time of testing for certification. 1.3.2 Approved Devices Systems consisting of one or more components used to provide a means of emergency egress. 1.3.3 Appurtenance Any and all components, esthetic or functional, used in conjunction with the primary components of an egress system. The component may or may not be directly attached to the primary component. 1.3.4 Assembly Drawings Drawings of the egress system that show the relationship of major components of a system in a typical cross section of the housing unit. 1.3.5 Egress System A combination of components that properly installed in a housing unit, wi11 provide a secondary means of egress from the housing unit when access to exterior passage doors is unavailable by reason of calamity such as fire, wind storm, etc. 1.3.6 Egress Window System An egress system has a window as its primary component. 1.3.7 Emergency Operating Instructions An egress system component providing all necessary user information required to operate the system and having been operated, to restore the system for further use. AAMA 1704-85 Page 1

1.3.8 Independent Quality Assurance Agency An agency not affiliated with the egress system manufacturer or user, approved to perform tests in accordance with this standard. 1.3.9 In-Plant Inspection Examination by an independent agency of all components of egress systems to comply with the test criteria of this standard. Available production units will be used for this inspection. 2. REQUIREMENTS 1.3.10 Operational Hardware Components of an egress system that require manipulation or operation by an occupant to effect egress. 1.3.11 Written Installation Instruction 2.1 Installation Documentation provided to a housing manufacturer by the supplier of an egress system. The documentation will specify the method of insta1lation required to assure acceptable function of the supplied egress system. The supplier shall maintain a permanent copy of the installation instructions. Egress window system manufacturers shall provide the housing manufacturers with written installation instructions (See Appendix). Compliance to these instructions is required to comply to these standards. 2.2 Performance For Primary Windows Used in Egress system Any primary window used as a functional part of an egress system shall meet all the requirements of AAMA 1701.2-1985, "Primary Window & Sliding Glass Door Voluntary Standard for Utilization in Manufactured Housing." 2.3 Dimensions All egress systems shall have a minimum clear horizontal dimension of 20 in. and a minimum clear vertical dimension of 24 in. when determined in accordance with Test A, 4.1 and shall have a minimum clear opening of 5 ft. 2 when determined in accordance with Test Method B, 4.2. 2.4 Operational 2.4.1 Emergency Operating Instructions Emergency operating instructions shall be applied to each egress window system and shall include the legend: "Do Not Remove." The instructions shall stipulate the removal of all temporary shipping materials immediately upon occupancy of the home. The instructions shall include the sequential steps required to affect egress, including operation of any or all appurtenances. 2.4.2 Operational Check An operational check of each installed egress window or device shall be made at the manufactured housing factory to determine that the window and stone sash or device and all operators function so that it can be readily opened to the minimum required dimensions without the use of any tools or binding of the window or device. Any window or device failing this check shall be removed and a replacement installed that passes the operability check. AAMA 1704-85 Page 2

2.4.3 Operational Hardware A primary window when used in an egress system shell have a total of no more than 2 locks or latches that require operation to affect egress. An appurtenance used in an egress system shall have a total of no more than 2 locks or latches that require operation to affect egress, except that in the case of appurtenances that require removal and are retained by pivot or swivel devices, shall have no more than 4 of these swivel or pivot devices requiring operation for removal of such panel or components. Appurtenance that require removal from the opening to accomplish egress shall be individually labeled on the removal panels, Remove and Set-Aside for Egress. Instructions for removal and set-aside are to be contained on that label. 2.4.4 Use of Rotary Operators Any window whose egress provisions are dependent on the operation of a rotary operator is unacceptable. Example: Awning windows uti1izing a single vent for egress and requiring a rotary operator for activation is unacceptable. Whereas, an awning window set in a separate frame whose activation requires only a 180 twist of the lock to allow egress is acceptable, even though a rotary operator is present for normal operation. 2.4.5 Opening Force 3. APPURTENANCES The single vector force required to complete each egress sequence of the system shall not exceed 20 lbs., when tested in accordance to Test C, 4.3. 2.4.6 Disabling the System Alterations or removal of a function or component of the egress system will cause the egress system to be in non-compliance with this standard. The egress system operating instruction label must include an appropriate warning regarding such alteration or removal. Such mechanisms or components shall be fastened so they will not be removed easily by the use of normal household tools such as slotted or Phillips head screw drivers, pliers and wrenches. Acceptable fasteners would include rivets, one-way screws and pop rivets. 2.4.7 Occupant Assistance After completion of sequence of operations specified in the instructions, an egress window system shall be capable of meeting the egress requirements without further occupant assistance. 2.4.8 Occupant Testing and Demonstration An egress window system, when subjected to operation, demonstration or testing by an occupant shall be capable of restoration to the operationa1" condition without damage to any component of the system or dwelling. 3.1 Dimensional Requirements The addition or inclusion of screens, secondary windows, or other appurtenances shall not change the dimensional requirements set forth for the system in 2.3. 3.2 Mechanism Requirements for Non-Operable Appurtenances The number of appurtenance mechanisms requiring operation to effect egress shall not exceed 4 and where swivel or pivot type devices are used to regain non-operable, removal panels, these swivel or pivot type devices shall have a normal operating surface of no less than.25 in 2 and be capable of operating by AAMA 1704-85 Page 3

application of a force of no more than 5 lbs. when tested in accordance with Test D, 4.4. All other mechanisms shall be tested as required in 2.4.5. 3.3 Non-Removable Appurtenance If an appurtenance such as a screen or secondary window is incorporated in the egress system in such a manner that it need not be removed or disengaged in any way in order to effect a fully opened exit, the requirements of 3.2 need not be met. 3.4 Appurtenance Instructions The operating instructions detailed in 2.4.1 shall include instructions on the required removal and replacement of any screen, storm sash or other appurtenance unless this information is attached separately to the appurtenance. 3.5 Integral Rolled-in Screen 4. TEST METHODS Integral rolled-in screens, permanently attached to the window frame and requiring removal for egress shall not be used in an egress window system. 4.1 Test Method A - Minimum Dimensions The minimum horizontal and vertical dimensions required by 2.3 shall be tested as follows: 4.1.1 Horizontal When the window is in the final position for egress, a 20 inch dowel shall be passed through the opening at the point of its least dimension while contacting only one point of the window frame at the horizontal orientation of the dowel. 4. 1.2 Vertical When the window is in the final position for egress, a 24 inch dowel shall be passed through the opening at the point of its least dimension while contacting only one point of the window frame, at the vertical orientation of the dowel. 4.2 Test Method B - Minimum Area The minimum area requirements of 5 ft 2 contained in 2.3 shall be determined by multiplying the clear horizontal dimension (which may exceed 20 in.) by the clear vertical dimension. Minimum dimensions are determined as in 4.1. Example: In egress systems whose minimum dimension is from the main frame bottom (relative to the occupied space) to that portion of the opening furthest from the bottom of the egress opening when in the fully opened position, then the minimum area shall be determined by multiplying the minimum dimension by the inside, side-to-side dimension. 4.3 Test Method C Operating Forces 4.3.1 Operating Forces For horizontal or vertical moving windows, a force gage shall be attached to the manual pull bar at its center point. After opening the latches or locks, a force not to exceed 20 lbs. shall be exerted in a direct pull parallel to the window in order to obtain movement in the opening direction. The window shall be in the closed and latched position prior to the test and shall have been subjected to 5 opening and closing cycles prior to the test. AAMA 1704-85 Page 4

4.3.2 Locks and Latches Locks and latches shall be tested as noted in 4.3.1 of this section except that the force gage shall be located in the center of the latch or lock handle. 4.4 Test Method D - Mechanical Device Operating Force (Appurtenances) 5. TEST REPORT A force gage of sufficient capacity using a point contact and having the ability to retain the maximum reading (Chatillion DDP - 50 or similar) shall be used. The force gage point shall be applied to the mechanism at the center of the normal force application area and sufficient force applied to disengage the appurtenance from its mounted position or operate to the egress (open) position. Removable panels requiring "set-aside" shall not exceed 20 lbs. maximum weight. The maximum reading obtained during operation shall be retained by the force gage until recorded and reset. 5. 1 Exclusions A test report shall include all requirements of this standard 1isted in the order shown in this standard. Where certain provisions of the standard do not apply, the notation "N.A." (Not Applicable) shall so denote these items. Where certain appurtenances are not supplied, such as storm windows or screens, the notation "N.S." (Not Supplied) shal] so denote those items. 5.2 Identification of System 6. CERTIFICATION The test report shall be for an egress window system which includes the primary window and all such appurtenances supplied as a part of the system by the window manufacturers, such as trim, secondary windows and screens not part of the primary window. The test report shall be accompanied by assembly drawings of the egress system and sufficient parts lists, drawings and extrusion drawings to positively identify the tested egress system. The test report number and the testing agency for the primary window portion of the system shall be included with the egress system test report. The manufacturer shall show evidence of continued compliance by affixing a quality certification label to the primary component of the system in accordance with ANSI Z34.1-1982, American National Standard Practice for Certification Procedures." In determining certifiability under this standard, compliance shall consist of original qualification specimen testing in accordance with each and every requirement of this standard followed by an inplant inspection system consisting of a minimum of two such inspections per year by an independent quality assurance agency. 7. EVIDENCE OF COMPLIANCE Compliance shall be evidenced by the listing of the egress window system by an independent, recognized quality assurance agency and presence of a recognizable label referencing compliance on each egress system. 8. INSTALLATION INSTRUCTIONS The installation instructions in the appendix to this standard are typical of instructions that should be followed for proper installation of egress windows. Egress window manufacturers shall provide the home manufacturer with written installation instructions for the applicable egress window used. AAMA 1704-85 Page 5

APPENDIX This appendix is not part of this standard. It is included for information purposes only. TYPICAL EGRESS WINDOW SYSTEMS & TYPES r". M Lotch. M lotch D' Dilklnce... ne. "X" TYPE I VERTICAL SLIDER & SINGLE HUNG NOTE I ILLUSTRATIONS VIEWED VU!WED from THE INTUIOR INTERIOR APPURTENANCE APPURTENANce 4 A- /' ~~ ~ ~ ~~-rr=========~ ---- %.s I", s~ It. Min. MiA_ <"> ~ _?,_ ~ _ly!!!!i!!!!!!!!!!!!!!!!!i_ llm!i!!!!!!!!!!!!!!!!!!!!!!.i l:l. l::l. Ue=e=;e=fa--t MOUNTED STORM TYPES r 0ltti.IIOI O'U.Dlal 2 Lit. Lite F iii. hi. II Stor", ShN'1ft with. Low., Lowe, Lit. I.lftowabl. R./llowabl. I -",---- -r--- -~- -.....-0.., -0..", OPUATING QPUAIING INTERIOR INTEIIOI.f.!.!G..f.I.U.2 ON! ONE UTI LIT! -~== -t MOUNTED STORM INTERIOR MOUNTeD MOUNTID Mil\. MiA. 20" 0".11. O ft. STORM (REMOVAILE) (REMOYAILf) '''Me 'lime WINOOW IXT!IIOR EXTERIOR MOUNTED... n.. Mo MOil. H.ALf HALf or full SCIlEEN SCREEN floor L111. L1fte Swl $wl 1 0' PI".t Pivot O."lce O,. (' Mea.) Mu.) Mo&. MOlL Latch Distance to lice "X" AAMA 1704-85 Page 6

The X location, maximum latch height and Y dimension, the maximum sill height, are set forth in another section of the construction standard. AAMA 1704-85 Page 7

MANUFACTURED HOME EGRESS WINDOW SYSTEM INSTALLATION INSTRUCTION 1. SPECIAL INSTRUCTIONS AND REQUIREMENTS 1.1 When delivered, these egress windows are in compliance with Section 3280.106 of the Federal Manufactured Housing Construction and Safety Standard 42 U.S.C. 5401. It is the responsibility of the manufactured home manufacturer, when installing these windows and appurtenances, to make sure they are not distorted or altered so as to no longer be in compliance. 1.2 Should any mandatory egress instructions included. herein or required in Section 3280.404 of the Standard. Be disregarded or violated, the certification of the window f' immediately negated and the unit will no longer be considered as being in compliance. In such cases, the responsibility of the window manufacturer for this certification will also cease. 1.3 The appurtenances supplied with these egress windows are approved and certified, and shall be installed in accordance with the detailed installation instructions. The use of any appurtenance system not approved for these windows or any alterations to the approved appurtenances negates the certification. 1.4 The Quality Certification labels shall not be removed by either the Manufactured Home Manufacturer or Dealer. Removal of said labels, negates the certification. 1.5 The method of mounting these egress windows should be in accordance with the detailed installation instructions. If an alternate method is used, it must not affect the operation of the window. Example: If screws are designated and samples are used, the frame members of the window must not be distorted in such a way as to cause the window to operate improperly. 2. ROUGH OPENING OPERATION 2.1 The Federal law requires that the height of the sill of any egress window system be limited. This maximum sill height is called out in the body of the Construction Standard. When egress windows are installed with the sill at the maximum height, all components that require operation will also be 1imited as to height and this dimension will also be called out in the body of the Construction Standard. The maximum sil1 height has been referred to as the "Y" dimension and the maximum component height dimension has been referred to as the X dimension in the illustrations that accompany the installation instructions. 2.2 The prepared rough opening should allow 1/8 clearance on each side and head of window frame including thickness of pre-finished paneling, shims, liners, etc., where used. 2.3 Avoid the use of badly warped, twisted or knotted framing members. 2.4 Sill of the rough opening must be straight and level. 2.5 Check for squareness by measuring across the opening from the head to the sill diagonally both ways. There should be no more than 1/8 between the measurements. AAMA 1704-85 Page 8

3. WINDOW INSTALLATION 3.1 Make certain all mounting surfaces (siding seams included) are securely fastened and flat around perimeter of window opening. 3.2 For surface mounted windows, apply a suitable non-hardening sealant tape on the backside of the window mounting flanges in order to provide a good seal. 3.3 Do not remove any shipping clips and keep operating sash closed and locked during installation. 3.4 Always handle windows properly. Always use both hands and pick them up by both side jambs. Never pick up and handle windows by the header only, sill only, or one side jamb only. This can damage the windows and possibly rupture the glazing seal and/or the joint caulking, thus resulting in a possible leak. 3.5 Carefully insert window into opening and rest weight of window onto sill. Adjust window location in opening from side to side until equal clearance is given to jambs. 3.6 Drive first fastener at approximate center of sill. Drive second fastener at approximate center of head, then drive third and fourth fasteners at approximate centers of each jamb. Drive the other remaining fasteners around perimeter of window. Avoid damage to joint seals and glass to metal caulking. Fasteners shall be driven perpendicular to plane of window. CAUTION: Power drivers when used should be adjusted so as not to cause excessive dimpling of the window flanges and consequently a possible distortion of the window frame. 3.7 If the exposed surfaces of the rough inside opening are to be trimmed out with pre-finished paneling, it must be done in a manner so as not to distort or twist the window frame members and make the operating sash tight or inoperable. 3.8 Do not obstruct locking mechanisms with inside trim, wood molding, etc. 3.9 Install screens, storm windows or other appurtenances as detailed in window manufacturer's installation instructions. 3.10 Remove all shipping clips located on the window including all appurtenances. Test operate the egress window system as detailed leaf in the affixed operating instructions. If the egress window system does not operate properly, determine the cause and correct immediately or replace the portion of the system that does not operate properly. 3.11 All shipping clips must be removed as soon as practical, and in every case prior to occupancy. 3.12 It is important that no obstruction be placed so as to restrict access to the window. AAMA 1704-85 Page 9

liner installed after window WINDOW D'M'- lr~" DIM'- Ir~" R.O'i R.O i TYPICAL SIDE J:'~MB AAMA 1704-85 Page 10