P. H. Robinson Consulting Urban Planning, Consulting and Project Management

Similar documents
P. H. Robinson Consulting Urban Planning, Consulting and Project Management

P. H. Robinson Consulting Urban Planning, Consulting and Project Management

12, 14, 16 and 18 Marquette Avenue and 7 Carhartt Street Zoning By-law Amendment Application - Preliminary Report

Planning Rationale in Support of an Application for Plan of Subdivision and Zoning By-Law Amendment

3390, 3392, 3394, 3396 and 3398 Bayview Avenue - Official Plan Amendment, Zoning By-law Amendment Application - Preliminary Report

111 Wenderly Drive Official Plan and Zoning By-law Amendment Applications - Preliminary Report

50+54 BELL STREET NORTH

6208 Jeanne D Arc Boulevard North. Planning Rationale. Site Plan Control

PLANNING RATIONALE REPORT CODEAU BUILDING LTD RIDEAU STREET OTTAWA DECEMBER 2013

Ashcroft Homes Trim Road Development Planning Rationale

1417, , 1427 & 1429 Yonge Street - Official Plan Amendment and Zoning Amendment Applications - Preliminary Report

Appendix1,Page1. Urban Design Guidelines. Back to Back and Stacked Townhouses. DRAFT September 2017

50 and 52 Finch Avenue East - Official Plan and Zoning By-law Amendment Applications - Preliminary Report

PLANNING RATIONALE REPORT

Urban Design Brief Dundas Street. London Affordable Housing Foundation. November Zelinka Priamo Ltd.

Planning Justification Report

1202 & 1204 Avenue Road Zoning By-law Amendment Application - Preliminary Report

900 ALBERT STREET PLANNING RATIONALE ADDENDUM NO. 2

71 RUSSELL AVENUE. PLANNING RATIONALE FOR SITE PLAN CONTROL APPLICATION (Design Brief)

836 St Clair Ave W - Zoning Amendment Application - Preliminary Report

25 Leonard Avenue - Official Plan Amendment and Zoning Amendment Applications - Preliminary Report

LITTLE MOUNTAIN ADJACENT AREA REZONING POLICY

Sheppard Ave East and 6, 8 and 10 Greenbriar Road - Official Plan Amendment and Zoning Amendment Applications - Preliminary Report

8.5.1 R1, Single Detached Residential District

Planning Rationale. 224 Cooper Street

66 Isabella Street Rezoning Application - Preliminary Report

PLANNING RATIONALE 680 BRONSON AVENUE OTTAWA, ONTARIO PROPOSED ZONING BY-LAW AMENDMENT

50 Wellesley Street East - Official Plan Amendment & Zoning Amendment Applications - Preliminary Report

PLANNING REPORT Gordon Street City of Guelph. Prepared on behalf of Ontario Inc. March 17, Project No. 1507

Director, Community Planning, Etobicoke York District

STAFF REPORT PLN September 11, 2017

470, 490 and 530 Wilson Avenue - Zoning Amendment and Rental Housing Demolition and Conversion Applications - Preliminary Report

Director, Community Planning, North York District NNY 23 OZ and NNY 23 RH

250 Lawrence Avenue West - Official Plan and Zoning By-law Amendment Applications Preliminary Report

RM-7, RM-7N and RM-7AN Districts Schedules

250, 252, 254 and 256 Royal York Road and 8 and 10 Drummond Street - Zoning By-law Amendment Application - Preliminary Report

Director, Community Planning, North York District NNY 10 OZ and NNY 10 RH

Chair and Members of Committee of Adjustment Toronto and East York Panel. A0596/16TEY Yonge St New 5 Storey Non-residential Building

Toronto and East York Community Council. Director, Community Planning, Toronto and East York District

3 and 5 Southvale Dr - Official Plan Amendment and Zoning Amendment Applications - Preliminary Report

RM-8 and RM-8N Districts Schedule

20 Edward Street Zoning Amendment Application - Preliminary Report

307 Sherbourne Street - Zoning Amendment Application - Preliminary Report

17-23 Clairtrell Road and 391 Spring Garden Avenue - OPA & Rezoning, Site Plan - Preliminary Report

RT-11 and RT-11N Districts Schedules

Zoning By-law Amendment & Site Plan Control Application

40-58 Widmer Street - Zoning Amendment Application - Preliminary Report

Director, Community Planning, South District

Plan Dutch Village Road

Director, Community Planning, Toronto and East York District

1970 Victoria Park Avenue and 9 Clintwood Gate Zoning By-law Amendment Application Preliminary Report

Richmond Street West Zoning Amendment Application - Preliminary Report

RM-11 and RM-11N Districts Schedule

Yonge Street and 3 Gerrard Street East - Zoning Amendment Application - Preliminary Report

770 BROOKFIELD ROAD Site Plan Control Atlantis Investments November 2017

5 to 25 Wellesley Street West and 14 to 26 Breadalbane Street - Zoning Amendment Application - Preliminary Report

740 and 750 York Mills Road and 17 Farmstead Road Zoning By-law Amendment Application Preliminary Report

45 & 77 Dunfield Avenue - Zoning Amendment Application - Preliminary Report

PLANNING REPORT. Lot 5, SDR Lot 6 and 7 Concession 3 Township of Normanby Municipality of West Grey County of Grey

111 Plunkett Road (formerly part of 135 Plunkett Road) - Zoning By-law Amendment Application and Plan of Subdivision Application - Preliminary Report

Islington Avenue - Official Plan and Zoning By-law Amendment Application - Preliminary Report

150 Eglinton Avenue East - Zoning Amendment Application - Preliminary Report

100 Ranleigh Ave - Zoning Amendment Application - Request for Direction Report

Urban Design Brief (Richmond) Corp. 1631, 1635, 1639, 1643 and 1649 Richmond Street City of London

3005 Bloor Street West and 14 Humbervale Boulevard - Official Plan and Zoning Amendment Applications - Preliminary Report

Kingston Road - Zoning Amendment and Draft Plan of Subdivision Applications - Preliminary Report

STAFF REPORT. September 25, City Council. Chief Planner and Executive Director, City Planning Division

PREPARED FOR: ADI DEVELOPMENT GROUP INC.

371 Richmond Road. Zoning By-law Amendment Site Plan Control

QUEEN STREET 219 VICTORIA STREET & THE REAR LANDS OF JOHNSON STREET AND 129 JOHNSON STREET PROPOSED HOTEL

Montreal Road District Secondary Plan [Amendment #127, October 9, 2013]

230 Oak Street- Official Plan Amendment and Zoning Bylaw Amendment Applications - Preliminary Report

MINOR VARIANCE REQUESTED:

BYLAW NUMBER 159D2016

4027 and 4031 Ellesmere Road Zoning Amendment and Draft Plan of Subdivision Applications - Request for Direction Report

April 3 rd, Monitoring the Infill Zoning Regulations. Review of Infill 1 and 2 and Proposed Changes

DECISION AND ORDER. PROCEEDING COMMENCED UNDER Section 45(12), subsection 45(1) of the Planning Act, R.S.O. 1990, c. P.13, as amended (the "Act")

CITY OF TORONTO. BY-LAW No (OMB)

RT-5 and RT-5N Districts Schedule

Planning Rationale in Support of an Application for Site Plan Control

Bathurst Street Zoning Amendment Application and Rental Housing Demolition Application under Municipal Code Chapter 667 Final Report

Galloway Road and 4097 Lawrence Avenue East - Zoning Amendment Application - Preliminary Report

144 and 150 Berry Road - Zoning By-law Amendment Application - Preliminary Report

1 Application Form 4

Accessory Coach House

6040 Bathurst Street and 5 Fisherville Road Zoning Bylaw Amendment Application Preliminary Report

Church Street and 117 Dundas Street East - Zoning Amendment Application - Preliminary Report

Richmond Street West - Zoning Amendment Application - Preliminary Report

39 Thora Avenue Zoning Amendment Application Preliminary Report

377 Spadina Rd and 17 Montclair Ave - Zoning Amendment Application - Preliminary Report

H6 Residential Terrace Housing and Apartment Buildings Zone

10 St Mary Street - Zoning Amendment Application - Preliminary Report

355 King St W and 119 Blue Jays Way - OPA & Rezoning Applications - Preliminary Report

3636 Bathurst Street Zoning By-law Amendment Application - Preliminary Report

507, 509 and 511 Kingston Road - Official Plan and Zoning By-law Amendment Applications - Preliminary Report

Planning Justification Report

PLANNING REPORT. 33 Arkell Road City of Guelph. Prepared on behalf of OHM Arkell Inc. August 4, Project No. 1327

RM-10 and RM-10N Districts Schedule

Official Plan & Zoning By-law Amendment Application Preliminary Report

Sherwood Forest (Trinity) Housing Corporation. Urban Design Brief

Transcription:

P. H. Robinson Consulting Urban Planning, Consulting and Project Management PLANNING RATIONALE REPORT 99-101 AND 103 PINHEY - SITE PLAN APPLICATION CITY OF OTTAWA PREPARED BY: P H ROBINSON CONSULTING SEPTEMBER 2018 100 Palomino Drive, Ottawa, Ontario K2M 1N3 Phone: 613 599 9216 Email: probinson@probinsonconsulting.com

P. H. Robinson Consulting Urban Planning, Consulting and Project Management This report has been prepared on behalf of 2641484 Ontario Inc. in support of a Site Plan Control Application for their lands at 99,101 and 103 Pinhey in the Hintonburg Community in Ottawa. The legal description of the property is Part of Lots 1,2 and 3 (east of Pinhey Street) Registered Plan 105, City of Ottawa (see Figure 1 - Survey Plan) in the Appendix Section. The property is located on the south east corner of Armstrong Street and Pinhey (see Figure 2 Location plan). To the west of the property (west side of Pinhey Street) is a surface parking area. To the east and south the lands are used for a mixture of commercial, and surface parking areas with some loading bays for nearby businesses. To the north and northwest the lands are primarily residential in nature and have been subject to some recent modern infill. The neighbourhood to the north has experienced a significant amount of modern residential infill development over the last few years. See photos in appendix The subject lands have 15.26 metres of frontage (50 ) on the east side of Pinhey and 31.93 metres of frontage (105 ) on Armstrong Street. The depth along the south property line is 26.99 metres (89 ) and along the rear (east) property line the dimension is 32.31 metres (106 ). See the survey plan (Figure 1) for further details. Full size copies of the survey plan are being filed as part of the site plan application. For zoning purposes the frontage along Pinhey Street is considered to be the front lot line. The property currently consists of two buildings that were built prior to 1908 with 103 Pinhey facing Pinhey and 99 Pinhey facing both Pinhey and Armstrong Streets. The two buildings are connected along the Pinhey Avenue frontage. At the present time both buildings are not occupied. These buildings were formerly the headquarters of a heating contracting business. There are surface parking areas for the property to the rear of the buildings. The intent of the site plan application is to build a 4 storey residential condominium building with approximately 1228 m2 (13220 ft2) of residential floor area within 24 units and 1 level of underground parking. There will be a roof terrace on the roof of the building which is intended to provide some amenity areas for residents and also to provide an area for residents to garden. The project name for the building is The Kensington and draws its architectural style from the Kensington area of London, England. See Figure 3 in the Appendix section for the site plan. The proposal calls for 24 new residential apartment units (9 of them will be 1 bedroom units and 15 will be 2 bedroom units). The proposal calls for 7 parking spaces in total which are all to be located in the underground parking area that is accessed a ramp from Armstrong Street. 100 Palomino Drive, Ottawa, Ontario K2M 1N3 Phone: 613 599 9216 Email: probinson@probinsonconsulting.com

P. H. Robinson Consulting Urban Planning, Consulting and Project Management An area for bicycle storage will be provided in the underground parking level for the building and there will also be some bicycle spaces provided along the interior side yard (south lot line) near the secondary entrance to the building. The building will be primarily constructed with a brick exterior with large windows and recessed balconies along the street frontages that allow for variation in the external building appearance. For more details refer to the architectural elevation drawings in the Appendix section of this report. The designs call for terraces and balconies on the Armstrong frontages and also balconies along the interior and rear yard sides of the building. The architectural style has been inspired by the white stone and clean lines of the Kensington area of London, the classic style of The Kensington Lofts and it has a timeless quality that will endure the test of time. The design of the Kensington allows for a contemporary portrayal of Victorian architectural characteristics (i.e. white and black exteriors, patterned mullions in windows, classic natural stone, pronounced front entries to units and high ceilings). As well the building has integrated modern panelling and features to keep up with the changing Hintonburg neighbourhood. By combining classic Victorian features with modern styling, we have posed to produce a timeliness building that will transcend through the growth and change that is expected to occur in Hintonburg. The proposed four storey residential condo development will be constructed with conventional wood and steel framing set on a strong cast in place concrete floor over an underground parking level. There will be 6 units per level consisting of 9 one bedroom and 15 two bedroom for a total of 24 units. Four of the ground floor units will have their entrance at grade and two out of these four units will have a lower basement level with an internal stair combined with an open to above area where 14 foot (4.3 m) tall glazing at the front will provide generous daylight into the unit at both levels. All other units will be accessible via two common entrances, having the principle one located at the corner of Pinhey and Armstrong street and a secondary one located at the south east corner of the building. A vehicular ramp along the east side of the property will be provided to access the underground parking area where utility locker and garbage rooms will also be located. A pedestrian ramp along the south property line will lead to the secondary entrance at the rear. The building will be provided with a common roof top terrace accessible by the common stair and elevator and all upper units will be equipped with their own 100 Palomino Drive, Ottawa, Ontario K2M 1N3 Phone: 613 599 9216 Email: probinson@probinsonconsulting.com

P. H. Robinson Consulting Urban Planning, Consulting and Project Management private terrace or balcony. There will be planters, new landscaping and hard landscaping along the street frontage of the property and along the interior side yard. Currently, the site does not have any natural vegetation or formal landscaping. The proposal calls for new trees on the City Right of Way on Armstrong Street. The new building will have a building footprint of approximately 514 m2 (5533 ft2) and a total building area of approximately 1228 m2 (13,220 ft2). The maximum building height is 14.36 m which is less than the permitted building height of 14.5 m. The City of Ottawa parking requirements for this type of development would be: Total required parking = The 1st 12 units are exempt from parking requirements and units in excess of 12 units are calculated at 0.5 spaces/unit and 0.1 spaces per unit for visitor parking for the units in excess of the 12th unit. This results in a parking requirement of (12 units x 0.5 spaces/unit = 6 parking spaces and then a visitor requirement of 12 x 0.1 spaces/unit = 1.2 spaces = 7.2 spaces which is rounded to 7 spaces. As a result, there are 7 total parking spaces required for the property and the development proposal being submitted calls for 7 parking spaces in total which are all in an underground parking level. Background studies addressing soils, environmental issues and civil engineering design are being filed as part of this Site Plan application. A full set of engineering, architectural, environmental, geotechnical, environmental noise, surveying and landscaping plans and reports are also being filed with this site plan submission. No major issues or concerns were identified in these studies. Zoning Under Zoning By-law 2008-250 the subject lands are zoned R4T-c (Residential Fourth Density Zone). This is a zone which permits apartment dwellings. The proposed use of the site is in conformity with the existing zoning and the majority of the setback requirements that apply to this site. Due to the shape of the lot there will be variances related to side yard, corner side yard and front yard setbacks and also variances related to amenity areas and the size of the roof top structure. The final set of variances required will be confirmed after the initial review of this application by Planning Staff and the Minor Variance application will be filed in the near future once we have received initial comments.. Details of the setbacks and the requirements are on the Site Plan drawing filed with the application. 100 Palomino Drive, Ottawa, Ontario K2M 1N3 Phone: 613 599 9216 Email: probinson@probinsonconsulting.com

P. H. Robinson Consulting Urban Planning, Consulting and Project Management Provincial Policy Statement The current Provincial Policy Statement (PPS) came into effect in April 2014 and it outlines the key matters of Provincial planning interest with respect to land use planning decisions made by municipal approval authorities. Any decisions that are made by municipal approval authorities must be consistent with the policies of the PPS. The following are sections of the PPS that are applicable to a redevelopment on the subject property: 1.1.1 Healthy, liveable and safe communities are sustained by: a) promoting efficient development and land use patterns which sustain the financial well-being of the Province and municipalities over the long term; The redevelopment on the site represent an efficient intensification of the site and will not create inefficient land use patterns in the area. e) promoting cost-effective development standards to minimize land consumption and servicing costs. The intensification of the site will be achieved through a 4 storey new building on the site and the sites parking requirements will be through underground parking. The existing infrastructure within the City Right of Way will be connected to the new building. 1.1.3.1 Settlement areas shall be the focus of growth and their vitality and regeneration shall be promoted. The property is within a settlement area of the City of Ottawa. 1.1.3.2 Land Use Patterns within settlement areas shall be based on: a) densities and a mix of land uses which: 1) efficiently use land and resources. This redevelopment of the property is an efficient use of the land and will allow for a sensitive infill development that meets the majority of City zoning requirements for this use and with underground parking to ensure that there is a maximum built utilization of the site. 2) are appropriate for, and efficiently use, the infrastructure and public service facilities which are planned or available, and avoid the need for their unjustified and/or uneconomical expansion; The proposed new development on the property will efficiently utilize the existing infrastructure available within the City Right of Way on both Armstrong Street and Pinhey Street. 1.4.3 Planning authorities shall provide for an appropriate range of housing types and densities to meet projected requirements of current and future residents of the regional market area by: c) directing the development of new housing towards locations where appropriate levels of infrastructure and public service facilities are or will be available to support current and projected needs. The proposed infill development is within an established neighbourhood with nearby infrastructure, public transit along nearby Wellington Street (providing 100 Palomino Drive, Ottawa, Ontario K2M 1N3 Phone: 613 599 9216 Email: probinson@probinsonconsulting.com

P. H. Robinson Consulting Urban Planning, Consulting and Project Management service every 15 minutes) and the nearby O-Train and future LRT and nearby parks (McCormick and Hintonburg Parks), schools and community facilities for residents needs. d) promoting densities for new housing which efficiently use land, resources, infrastructure and public service facilities, and support the use of alternative transportation nodes and public transit in areas where it exists or is to be developed; The infill development represents an efficient use of land on the property and utilizes existing infrastructure Official Plan Designation City of Ottawa Official Plan The site is designated General Urban Area in the Urban Policy Plan of the City of Ottawa Official Plan. The General Urban Area designation permits the development of a full range and choice of housing types to meet the needs of all ages, incomes and life circumstances, in combination with conveniently located employment, retail, service, cultural, leisure, entertainment and institutional uses. This will facilitate the development of complete and sustainable communities. A broad scale of uses is found within this designation, from ground-oriented single-purpose to multi-storey mixed-use; from corner store to shopping centre. Permitted uses within a General Urban Area include residential. Key policies within the General Urban Area designation that are applicable to this infill development are contained in Section 3.6.1 of the Official Plan and are: 3.6.1.1General Urban Area areas are designated on Schedule B. The General Urban Area designation permits all types and densities of housing, as well as employment, retail uses, service, industrial, cultural, leisure, greenspace, entertainment and institutional uses. The density of housing proposed is permitted in this designation. 3.6.1.3 When considering a proposal for residential intensification through infill or redevelopment in the General Urban Area, the City will: Recognize the importance of new development relating to existing community character so that it enhances and builds upon desirable established patterns and built form; The proposed 4 storey residential building located close to or on the edge of the property is in general conformity with existing residential development and recent infill projects in the neighbourhood. In addition, the subject property is located within the area covered by the Scott Street Secondary Plan. This Secondary Plan has a number of land use designations within its boundaries which are roughly bounded by the Ottawa 100 Palomino Drive, Ottawa, Ontario K2M 1N3 Phone: 613 599 9216 Email: probinson@probinsonconsulting.com

P. H. Robinson Consulting Urban Planning, Consulting and Project Management River Parkway, Northwestern Avenue, Bayview Avenue and then lands to the north of Wellington Street but not fronting onto Wellington Street. The subject property is located within the Low-Rise Residential designation which would allow for the height of building and type of use that is being proposed. The range of uses permitted in the General Urban Area designation in the Official Plan is permitted in the Low-Rise Residential designation of the Secondary Plan. Schedule B of the Secondary Plan outlining Maximum Building Heights identifies the subject property as having a maximum building height in line with the existing zoning which allows for a building height of 14.5 m. The subject property is in conformity with this Secondary Plan policy. Conclusions The proposed development of a new 4 storey residential building with 24 apartments units and underground parking at 99-101-103 Pinhey is consistent with the majority of current zoning, and the relevant Official Plan and Secondary Plan policies for these lands. The site represents a sensitive infill development that will allow for: a well designed contemporary mixed use building that will be located within an established neighbourhood that will add to the character of the street and the neighbourhood an underground parking level which results the required being located beneath the building and with the majority of the streetscape along both roads being occupied by living space of the building. a new development that meets the majority of current zoning regulations a re-development of the existing property that will contribute to the overall intensification of these sections of Pinhey and Armstrong Streets through a sensitive development. Through the site plan process there are a number of key engineering studies and drawings required in support of the development. These studies show that the site can be serviced through existing service connections along Pinhey and Armstrong Streets. The overall site drainage and grading has been designed based on current City guidelines and there will be some roof top storage. Landscaping will be provided along the side, and rear yards to provide screening and buffering to adjacent properties. As well, some new landscaping within the City Right of Way on Armstrong Street is being proposed. The proposed building height of this development is within the maximum 100 Palomino Drive, Ottawa, Ontario K2M 1N3 Phone: 613 599 9216 Email: probinson@probinsonconsulting.com

P. H. Robinson Consulting Urban Planning, Consulting and Project Management permitted building height. It is our opinion that the proposed development is consistent with the Provincial Policy Statement and the City of Ottawa Official Plan and the majority of relevant zoning and Secondary Plan regulations. It is being proposed at an appropriate scale of infill development and will be compatible with surrounding land uses and will contribute to this area of Hintonburg. 100 Palomino Drive, Ottawa, Ontario K2M 1N3 Phone: 613 599 9216 Email: probinson@probinsonconsulting.com

P. H. Robinson Consulting Urban Planning, Consulting and Project Management APPENDIX PAGE 1 - SURVEY PLAN PAGE 2 - LOCATION PLAN PAGES 3-8 - FLOOR PLANS, ARCHITECTURAL ELEVATION PLANS AND SITE PLAN PAGES 9-12 PHOTOS OF PROPERTY AND SURROUNDING AREA. PHOTOS 1 AND 2 OF PINHEY FRONTAGE OF PROPERTY, PHOTO 3 OF ARMSTRONG FRONTAGE OF PROPERTY AND PHOTO 4 IS OF RECENTLY BUILT TOWNHOUSES ON NORTH WEST CORNER OF PINHEY AND ARMSTRONG 100 Palomino Drive, Ottawa, Ontario K2M 1N3 Phone: 613 599 9216 Email: probinson@probinsonconsulting.com

CLIENT: 2 Pconcepts 739 RIDGEWOOD AVE., UNIT 201 OTTAWA, ONTARIO, K1V 6M8 VEHICULAR RAMP DOWN WINDOW WELL DRAIN LOW HEAD STORAGE SLOPE 15% WINDOW WELL OPEN TO ABOVE OPEN TO BELOW DRAIN LOW HEAD STORAGE LAUNDRY 2 UNIT 103 534ft² SLOPE 20% OPEN TO ABOVE LAUNDRY 2 LOWER UNIT 103 735ft² OPEN TO BELOW 1 LOWER UNIT 102 491ft² MASTER FDC POWDER UTILITY FLOOR DRAIN ENSUITE ENSUITE GARBAGE TRENCH DRAIN O.H. DOOR ENTRANCE VESTIBULE ENTRANCE LOBBY UP MAIL UP 1 UPPER UNIT 101 625ft² POWDER W/D 2 + DEN UPPER UNIT 102 773ft² DEN POWDER 1 UNIT 104 634ft² W/D 11 10 09 08 07 06 UP EXIT STAIR #1 FLOOR DRAIN 7 PARKING SPACES ASPHALT FLOOR DRAIN UP DN EXIT STAIR #1 ENSUITE CORRIDOR ENSUITE POWDER 05 04 03 02 ISSUED FOR COORDINATION PE SEPT 10 2018 01 FOR REVIEW PE JULY 20 2018 No. REVISIONS BY DATE WASH STORAGE FLOOR DRAIN PET WASH UP DRAIN EXIT STAIR #2 VENTILATION WELL DEN 1 + DEN UNIT 106 723ft² W/D WASH 2 UNIT 105 625 ft ² ENSUITE UP EXIT STAIR #2 VENT. WELL NOT AUTHENTIC UNLESS SIGNED AND DATED CONSULTING ENGINEERS ELEVATOR MASTER ELEVATOR STRUCTURAL W/D MECHANICAL ELECTRICAL DRAIN VENTILATION WELL PEDESTRIAN RAMP UP VENTILATION WELL GRASS SLOPING OF PEDESTRIAN RAMP ABOVE 8% GRASS BYCICLES DESIGNED BY: DRAWN BY: APPROVED BY: PROJECT 99 PINHEY DRAWING TITLE 1 A-1 LOWER LEVEL FLOOR PLAN SCALE: 1:75 2 A-1 MAIN LEVEL FLOOR PLAN SCALE: 1:75 LOWER & MAIN LEVEL FLOOR PLANS PROJECT NO. 0293 DATE SEPT 10, 2018 A-1 D07-12-17-0102

CLIENT: 2 Pconcepts 739 RIDGEWOOD AVE., UNIT 201 OTTAWA, ONTARIO, K1V 6M8 MASTER TERRACE/ TERRACE BELOW W/D TERRACE/ TERRACE BELOW 2 UNIT 203 838ft² RD MASTER MASTER BATH RD TERRACE/ FOYER TERRACE BELOW 1 + DEN UNIT 201 747ft² DEN BATH ENSUITE WASHER/ DRYER WASH FOYER 2 UNIT 202 859ft² MASTER 1 UNIT 204 519ft² FIXED BENCHES PLANTER FIXED BENCHES BBQ SCUPPER 11 10 09 08 W/D BATH PLANTER FIXED TABLES PLANTER FIXED TABLES PLANTER 07 06 05 UP CORRIDOR 04 DN EXIT STAIR #1 FOYER WASH MASTER MAKE UP AIR UNIT, REFER TO MECHANICAL FOR REQUIREMENTS PERGOLAS ABOVE BBQ BELOW 03 02 01 ISSUED FOR COORDINATION PE SEPT 10 2018 No. REVISIONS BY DATE W/D WASH RD FIXED BENCHES RD 2 UNIT 206 862ft² ENSUITE W/D UP EXIT STAIR #2 PLANTER UP EXIT STAIR #2 NOT AUTHENTIC UNLESS SIGNED AND DATED MASTER 2 UNIT 205 731ft² ELEVATOR REFER TO MECH DWGS FOR ALL DRY COOLER UNIT REQUIREMENTS ELEVATOR LOBBY ELEVATOR CONSULTING ENGINEERS STRUCTURAL MECHANICAL ELECTRICAL SCUPPER BELOW BELOW DESIGNED BY: PROJECT DRAWN BY: APPROVED BY: 99 PINHEY DRAWING TITLE 1 A-2 TYPICAL LEVEL FLOOR PLAN SCALE: 1:75 2 A-2 ROOF LEVEL PLAN SCALE: 1:75 TYPICAL & ROOF LEVEL FLOOR PLANS PROJECT NO. 0293 DATE SEPT 10, 2018 A-2 D07-12-17-0102

CLIENT: PROPERTY LINE PROPERTY LINE 14.5m PERMITTED HEIGHT LIMIT 2 Pconcepts 739 RIDGEWOOD AVE., UNIT 201 OTTAWA, ONTARIO, K1V 6M8 63.07 AVERAGE GRADE 1 NORTH ELEVATION (ALONG ARMSTRONG STREET) A-3 SCALE: 1:75 11 PROPERTY LINE FOLDEDFACADE ON ARMSTRONG STREET PROPERTY LINE 14.5m PERMITTED HEIGHT LIMIT 10 09 08 07 06 05 04 03 02 01 ISSUED FOR COORDINATION PE SEPT 10 2018 No. REVISIONS BY DATE NOT AUTHENTIC UNLESS SIGNED AND DATED CONSULTING ENGINEERS STRUCTURAL MECHANICAL ELECTRICAL DESIGNED BY: PROJECT DRAWN BY: APPROVED BY: 99 PINHEY 63.07 AVERAGE GRADE 2 WEST SIDE ELEVATION (ALONG PINHEY STREET) A-3 SCALE: 1:75 DRAWING TITLE PROJECT NO. 0293 DATE NORTH & WEST SIDE ELEVATIONS SEPT 10, 2018 A-3 D07-12-17-0102

CLIENT: PROPERTY LINE PROPERTY LINE 14.5m PERMITTED HEIGHT LIMIT 2 Pconcepts 739 RIDGEWOOD AVE., UNIT 201 OTTAWA, ONTARIO, K1V 6M8 63.57 63.07 AVERAGE GRADE 62.65 62.33 8% 18% 60.80 1 A-4 EAST SIDE ELEVATION SCALE: 1:75 OVERHEAD GARAGE DOOR TRENCH DRAIN 8.8% 11 10 PROPERTY LINE PROPERTY LINE 14.5m PERMITTED HEIGHT LIMIT 09 08 07 06 05 04 03 02 01 ISSUED FOR COORDINATION PE SEPT 10 2018 No. REVISIONS BY DATE NOT AUTHENTIC UNLESS SIGNED AND DATED CONSULTING ENGINEERS STRUCTURAL MECHANICAL ELECTRICAL DESIGNED BY: PROJECT DRAWN BY: APPROVED BY: 99 PINHEY 63.07 AVERAGE GRADE DRAWING TITLE 1 A-4 SOUTH SIDE ELEVATION SCALE: 1:75 PROJECT NO. 0293 EAST AND SOUTH ELEVATIONS DATE A-4 SEPT 10, 2018 D07-12-17-0102

CLIENT: PROPERTY LINE PROPERTY LINE 14.5m PERMITTED HEIGHT LIMIT 2 UNIT 402 CORR. UNIT 405 Pconcepts 739 RIDGEWOOD AVE., UNIT 201 OTTAWA, ONTARIO, K1V 6M8 TERRACE UNIT 302 CORR. UNIT 305 TERRACE UNIT 202 CORR. UNIT 205 TERRACE UNIT 102 (UPPER) CORR. UNIT 105 WALKWAY/ RAMP 63.07 AVERAGE GRADE ARMSTRONG UNIT 102 (LOWER) UNDERGROUND PARKING 1 A-5 BUILDING SECTION SCALE: 1:75 11 10 09 08 07 06 05 04 03 02 01 ISSUED FOR COORDINATION PE SEPT 10 2018 No. REVISIONS BY DATE NOT AUTHENTIC UNLESS SIGNED AND DATED CONSULTING ENGINEERS STRUCTURAL MECHANICAL ELECTRICAL DESIGNED BY: PROJECT DRAWN BY: APPROVED BY: 99 PINHEY DRAWING TITLE PROJECT NO. 0293 DATE BUILDING SECTION SEPT 10, 2018 A-5 D07-12-17-0102

CLIENT: CONCRETE WALKWAY TO CITY STANDARDS REFER TO CIVIL N 1 SP01 SITE PLAN SCALE: 1:75 P I N H E Y S T R E E T CONCRETE WALKWAY TO CITY STANDARDS REFER TO CIVIL EXISTING SIDEWALK CONCRETE WALKWAY TO CITY STANDARDS CONCRETE WALKWAY TO CITY STANDARDS 0.5m GRASS 1.1m 1.5m 4.8m 1.6m 6.0m GRASS 15.46 N23 07'45"W 1.49m CONCRETE WALKWAY TO CITY STANDARDS REFER TO CIVIL G-1 FRONT YARD SETBACK 2.1m PEDESTRIAN RAMP UP EXIT STAIR #1 MAIN ENTRANCE 1.5m ENTRANCE VESTIBULE SUITE ENTRANCE 31.93 N34 12'40"E SIDE YARD SETBACK PROPOSED 4 STOREY RESIDENTIAL BUILDING T.O. GRND FLOOR 25.3m SUITE ENTRANCE WINDOW WELL WINDOW WELL SECONDARY ENTRANCE ELEVATOR SUITE ENTRANCE GARBAGE 2.6m 2.5m 20.3m 63.57 UNDERGROUND 2.5m 63.03 63.21 GRASS GRASS, REFER TO LANDSCAPING FOR REQUIREMENTS FDC UNIT PAVERS GRASS A R M S T R O N G S T R E E T 0.9m 1.4m 1.1m 1.1m CORNER SIDE YARD SETBACK 21.0m CONCRETE WALKWAY TO CITY STANDARDS REFER TO CIVIL GRASS, REFER TO LANDSCAPING FOR REQUIREMENTS EXISTING SIDEWALK FOR ALL SITE LANDSCAPING REFER TO DRAWINGS L.1 & L.2 PREPARED BY JAMES B. LENNOX & ASSOCIATES INC. G-4 26.99 N66 02'30"E G-3 OUTLINE OF OUTLINE OF ABOVE 18.0m ABOVE RETAINING WALL, REFER TO CIVIL AND TO LANDSCAPING FOR OUTLINE OF REQUIREMENTS. AJDACENT BUILDING TO REMAIN. SHRUBS 6.0m BYCICLES 25.4m 1.1m 1.5m UNIT PAVERS 2.6m 3.7m EXIT STAIR #2 EXIT G-2 HEATED VEHICULAR RAMP DOWN 62.65 REAR YARD SETBACK 63.39 GRASS 1.5m 0.2m 4.3m 0.2m 35.94 N 23 18'35"W 7.6m 20.3m REQUIRED SETBACK AS PER SECTION 161(12)(1)(iii) REQUIRED SETBACK AS PER SIDE YARD SETBACK REQUIRED SETBACK AREA AS PER SECTION 161(12)(1)(iii) = 41.96 sq.m AVERAGE GRADE CALCULATION TO DETERMINE PERMIT BUILDING HEIGHT ELEVATIONS G-1=63.21 G-2=62.65 G-3=63.39 G-4=63.03 AVERAGE GRADE = 63.07 99 PINHEY STATISTICS ITEM Zone Minimum Lot Area Minimum Lot Width Maximum Building Height (from EAG) Minimum Front Yard Setback Minimum Corner Side Yard Setback Minimum Side Yard Setback Minimum Rear Yard Setback HP ROOF TERRACE N.T.S. 5.8m Minimum Area Setback at Rear / Side Yards, As Per Section 161(12)(1)(iii) Minimum Parking Spaces Minimum Visitor Parking Spaces Minimum Bicycle Parking Spaces Minimum Amenity Area Minimum Communal Amenity Area Minimum Communal Amenity Area Soft Landscaping 4.8m 9.7m 5.2m 10.4m 10.5m 1.6m 9.9m 7.6m 6.9m ELEVATOR LOBBY REQUIRED R4T-c 450.0 sq.m 12.0 m 14.5 m 1.49 m 3.0 m 2.50 m for the first 21.0 m 6.00 m for > 21.0 m 1.5 m 30% of Lot Depth X 30% of Lot Width 30% of 28.4 m X 30% of 16.4 m 8.52 m X 4.92 m = 41.92 sq.m 0 for 1st 12 units & 0.5 per unit after 12 units = 6 0 for 1st 12 units & 0.1 per unit after 12 units = 1.2 0.5 spaces per unit = 12 15 sq.m per unit for 1st 8 units = 120 sq.m 6 sq.m for unit after 8 units = 96 sq.m 100% of the 1st 8 units Amenity Area = 120 sq.m 80% (96 sq.m) PRESSURE TREATED WOOD TERRACE ROOF ACCESS STAIRS PROVIDED 643.85 sq.m 15.46 m 14.36 m Maximum Parapet Height Above Max. Building Height 0.3 m 0.57 m Maximum Building Height with Parapet (from EAG) 14.8 m 15.07 m 0.0 m 0.0 m 2.50 m 2.50 m 1.5 m x sq.m 6 1 12 (10 indoor) 225.92 sq.m 22.40 sq.m (Grade) 100.88 sq.m (Roof) 18.1% (22.40 sq.m) Communal Amenity Area Location At Grade and in the Rear Yard Grade / Rear / Roof Minimum Roof Top Access Area 10.5 sq.m 35.88 sq.m Existing Average Grade (EAG) Elevation 63.07m 11 10 09 08 07 06 05 04 03 02 01 FOR REVIEW PE JULY 20 2018 No. REVISIONS BY DATE NOT AUTHENTIC UNLESS SIGNED AND DATED CONSULTING ENGINEERS STRUCTURAL MECHANICAL ELECTRICAL DESIGNED BY: PROJECT DRAWING TITLE 2 Pconcepts 739 RIDGEWOOD AVE., UNIT 201 OTTAWA, ONTARIO, K1V 6M8 FOR REVIEW PE SEPT 10 2018 FOR REVIEW PE SEPT 07 2018 FOR REVIEW PK AUG 30 2018 FOR REVIEW PE AUG 28 2018 FOR REVIEW PE AUG 01 2018 DRAWN BY: 99 PINHEY APPROVED BY: Number of Dwelling Units Building Area GFA (As defined in the zoning bylaw) 24 514.37 sq.m 1228.74 sq.m PLAN #XXXX PROJECT NO. 0293 DATE JULY 04, 2018 SITE PLAN SP-01 D07-12-17-0102