S.T.E.P. SEWER SYSTEM City of Lacey Connection Permit Process

Similar documents
S.T.E.P./GRINDER SEWER SYSTEM City of Lacey

Boundary Line Adjustment / Lot Combination General Instructions and Submittal Forms

City of Yelm. Community Development Department BOUNDARY LINE ADJUSTMENT OR LARGE LOT SUBDIVISION

CITY OF EAST WENATCHEE BOUNDARY LINE ADJUSTMENT FORM

New Service Application

CHAPTER 2 RELATED DOCUMENTS AND FORMS

TEMPORARY CONSTRUCTION EASEMENT JEA SEWER SYSTEM CUSTOMER OWNED, OPERATED AND MAINTAINED

WAKE COUNTY STORMWATER CONTROL STRUCTURE AND ACCESS EASEMENT AND AGREEMENT (Corporate)

WASHINGTON STATE COUNTY AUDITOR/RECORDER'S INDEXING FORM

Environmental and Engineering Services EASEMENT INFORMATION AND EXAMPLE DOCUMENTS

BOARD OF COUNTY COMMISSIONERS AGENDA ITEM SUMMARY

NO PROTEST AGREEMENT AND COVENANT RUNNING WITH THE LAND. Parcel #(s): R: T: S: Q: Q: Project Name:

PERMISSIVE LAND USE AGREEMENT

This is a sample form for information ONLY. UTILITY INFRASTRUCTURE CONVEYANCE AND SERVICE AGREEMENT

DEED OF EASEMENT & MAINTENANCE AGREEMENT FOR STORMWATER MANAGEMENT FACILITIES THIS DEED OF EASEMENT AND MAINTENANCE AGREEMENT FOR

GENERAL WARRANTY DEED

RESTRICTIVE COVENANT NON-REMONSTRANCE AGREEMENT (PURSUANT TO CITY OF OREGON CITY ORDINANCE NO )

DECLARATION OF COVENANT

OSSF Permit Application

SUBMITTAL REQUIREMENTS: The number indicates the number of copies for submittal (if applicable).

TEMPORARY CONSTRUCTION EASEMENT AND AGREEMENT JEA WATER AND WASTEWATER SYSTEMS CUSTOMER OWNED, OPERATED AND MAINTAINED

SPECIAL SERVICE AREA DISCLOSURE

TRANSFER OF DEVELOPMENT RIGHTS CONSERVATION EASEMENT

AGREEMENT FOR TEMPORARY CONSTRUCTION EASEMENT AND PERMANENT SEWER UTILITY EASEMENT

New Commercial Service Application

CITY OF INDIANAPOLIS GRANT OF PERPETUAL DRAINAGE EASEMENT AND RIGHT-OF-WAY

DEFERRED IMPACT FEES INFORMATION AND APPLICATION

6. LIST THE CAUSE DOCKETED NUMBER (E.G. ZONING CASE NUMBER, PLAT NUMBER...)

Easement. After recording return to: City Clerk City of Puyallup 333 South Meridian Puyallup, WA 98371

DECLARATION OF COVENANT FOR INSPECTION AND MAINTENANCE OF PRIVATE STORMWATER FACILITIES. City of Mercer Island, a Washington municipal corporation

EASEMENT AGREEMENT. hereinafter called Grantor, (whether grammatically singular or plural) and the:

ORDINANCE NO

TRANSFER OF DEVELOPMENT RIGHTS CONSERVATION EASEMENT

NON-EXCLUSIVE TRAIL AND UTILITY EASEMENT

SUBMITTAL REQUIREMENTS: The number indicates the number of copies for submittal (if applicable).

EASEMENT AGREEMENT (Distributor Performance Non-Exclusive)

IMPACT FEE DEFERRAL APPLICATION

SUBDIVISION BACKBONE COVER LETTER

It is necessary for the Board to adopt the attached resolution accepting the dedication of the easement.

SHORT PLAT Information

PIPELINE RIGHT-OF-WAY EASEMENT

PERMANENT DRAINAGE EASEMENT

EASEMENT AGREEMENT. hereinafter called Grantor, (whether grammatically singular or plural) and the:

CITY OF SARALAND FINAL SUBDIVISION PLAT REVIEW

MECKLENBURG COUNTY Land Use & Environmental Services Agency Groundwater & Wastewater Services

Town of P O Box SEWER. tion and. for. of any to a sewer. Provide the. property

Shared Well Agreement

City of Columbia ENgiNEEriNg regulations Part 12: application For NEW WatEr service table of CoNtENts Paragraph Description Page No.

Stormwater Treatment Facility Maintenance Agreement

City of Edmonds TEMPORARY CONSTRUCTION EASEMENT

DEED OF EASEMENT Utility Line and Grinder Pump

MARTIN COUNTY BOARD OF COUNTY COMMISSIONERS

CITY OF MERCER ISLAND

Storm Water Management BMP Maintenance Agreement City of St. George, Utah

PERMANENT EASEMENT AGREEMENT. good and valuable consideration, the sufficiency and receipt of which is hereby acknowledged, The Esther Harrison

PERPETUAL STORM WATER DRAINAGE EASEMENT (Non-Exclusive) This Non-Exclusive Perpetual Storm Water Drainage Easement (this Easement ) is

MARTIN COUNTY BOARD OF COUNTY COMMISSIONERS

BILL OF ASSURANCE CHOCTAW FIFTH ADDITION (Blocks 29-32)

BILL OF ASSURANCE NAVASOTA FIRST ADDITION

SPECIAL WARRANTY DEED. THIS DEED, made this day of, 2005, between

PRELIMINARY PLAT Checklist

RIGHT OF WAY DEDICATION DEED

Simple Land Division by Love and Affection - Application Checklist

APPROVAL REQUIRED... A5 APPLICATION FOR APPROVAL OF PRELIMINARY PLAN... A6 APPLICATION FOR APPROVAL OF DEFINITIVE PLAN... A7

LAND USE APPLICATION

STATEMENT OF CONDITIONS FOR USE OF

Shawnee Woods Subdivision

BINDING SITE PLAN Checklist

WILSON COUNTY Health & Public Safety Office

Easement under Section 65 of The Water Security Agency Act

Dallas Sloan General Manager Barron Area Phone: (715) Toll Free: Fax: (715) NEW SERVICE PROCESS

BILL OF ASSURANCE DAKOTA FIRST ADDITION

THIS DEED OF TRUST, ASSIGNMENT OF RENTS AND LEASES, AND SECURITY AGREEMENT ("Deed of Trust") is made this day of, ("Grantor"), whose

LINE EXTENSION APPLICATION AGREEMENT PROJECT: LINK#

MAINTENANCE AND INDEMNITY AGREEMENT PURSUANT TO SEAGATE VILLAGE COMMUNITY ASSOCIAITON S DECLARATION OF COVENANTS, CONDITIONS AND RESTRICTIONS

APPLICATION FOR ANNEXATION TO THE WEST BAY SANITARY DISTRICT

EXHIBIT A CONDITIONAL USE PERMIT. The following form has been formatted to meet the recording standards of the Wake County Register of Deeds Office.

BOONE COUNTY, MISSOURI RESOURCE MANAGEMENT DEPARTMENT (573)

CONSERVATION EASEMENT INCLUDING MITIGATION

EXHIBIT "B", Page 1 of 5 This Instrument Was Prepared By: Record and Return To: Lynn Bodor I Land Records City of Boca Raton 201 Palmetto Park Road Bo

PLAT AGREEMENT TO MAINTAIN STORMWATER FACILITIES AND TO IMPLEMENT A POLLUTION SOURCE CONTROL PLAN (REPRESENTATIVE)

AGREEMENT. Private Stormwater Management Facilities Operation and Maintenance And Right of Entry

PLANNING DIRECTOR. Approved by the Planning Director on this day of, A.D. 20. day of, A.D. 20. Approved by the Fire Chief on this

PERMANENT EASEMENT AGREEMENT

Easement Sidewalk Easement Right of Way Dedication Deed Stormwater Management & BMP Facilities Agreement Alternative Methods or Construction

City of Columbia ENgiNEEriNg regulations Part 6: ProCEDurEs For the subdivision of land table of CoNtENts Paragraph Description Page No.

CONSERVATION EASEMENT AND RESTRICTION

TITLE 145: DEPARTMENT OF PUBLIC LANDS SUBCHAPTER AGRICULTURAL HOMESTEAD WAIVER PROGRAM RULES AND REGULATIONS

Explanation of Permanent Stormwater Management Facilities Maintenance Agreement

FEE SIMPLE OPTION AGREEMENT Ecosystem Enhancement Program SPO File Number

NOW, THEREFORE, BE IT RESOLVED by the Albany City Council that it does hereby accept this easement.

STANDARDIZED LEGAL DESCRIPTIONS AND EXHIBITS

50-Foot Non-Exclusive EASEMENT AGREEMENT

THIS TRANSACTION IS EXEMPT FROM CALIFORNIA DOCUMENTARY TRANSFER TAX PURSUANT TO SECTION OF THE CALIFORNIA REVENUE AND TAXATION CODE.

City of Columbia ENgiNEEriNg regulations Part 8: sanitary sewer main EXtENsioN table of CoNtENts Paragraph Description Page No.

STORMWATER MANAGEMENT AGREEMENT AND DECLARATION OF EASEMENT

DEED AND DEDICATION FOR PUBLIC RIGHT OF WAY

The Drainage Encroachment Agreement has been revised as of August 2014.

CITY AND COUNTY OF BROOMFIELD SUBDIVISION IMPROVEMENT AGREEMENT FOR (PROPERTY NAME - ALL CAPS)

RESOLUTION NO

Transcription:

APPENDI X D

S.T.E.P. SEWER SYSTEM City of Lacey Connection Permit Process 420 College St r eet SE Lacey, WA 98503 Step 1. Step 2. Step 3. Step 4. Step 5. Complete, sign and date the Application form, the Easement form, the Bill of Sale, and the Power of Attorney if required. Turn all forms into t h e City an d pay t h e r equ ired fees. The City must approve the tank location prior to the tank being set in the ground. A preconstruction meeting must be held prior to any work being don e. A 48 hour notice is required prior to any STEP inspection or testing pr ocess. All appu r t en an ces m u st be pr et est ed befor e sch edu ling an y STEP inspection or testing process. The Homeowners Information Sheet from the STEP application packet m u st be left in t h e h ou se. A r einspect ion fee will be ch ar ged for r epeat ed inspect ion s du e t o failed tests. One User Information Manual shall accompany each separate application. After Installation 1. The property owner must maintain access to the septic tank and controls at all times for City maint en an ce pu r poses. Th e t an k r iser lid m ay n ot be cover ed or buried although the owner may place a bird bath, potted plant or other yard decoration on the riser lid, as long as it can be readily removed for repair or maintenance. 2. The plumbing from the home to the interceptor tank is the responsibility of the property owner. The City will service and maintain all equipment excepting that which is m en t ion ed above aft er t h e war r an t y per iod of on e year h as expired. 3. The City of Lacey maintenance department should be contacted at 491-5644 if an y pr oblem s with t h e syst em ar e en cou n t er ed. 4. The City of Lacey maintenance department should be contacted at 491-5644 if the high water alarm and light are activated. The water usage should also be immediately curtailed. Fr om t h e t ime t h e h igh wat er alar m is act ivat ed, t h er e is approximately a 1 day storage capacity in the septic tank. D - 1 02/ 14

APPLICATION S.T.E.P Sewer System APPLICANT TO COMPLETE SHADED PROTIONS ONLY Subdivision: Lot #: Div. #: Service Address: Billing Name: Phone Billing Address (if different): City: ZIP: Email Address: Builder/Contractor: Phone: Contractor's License #: ATTACH SKETCH. Note: A sketch of the proposed installation must accompany the application. See the installation instruction for an example. A preconstruction meeting must be held with the City Inspector prior to construction. Is project connected to City water? Yes No If no, connection fees must be calculated and collected prior to connecting to the sewer line. In addition, a Service Application needs to be created to trigger monthly billing. The following fees are required at time of installation: RATE TOTAL RECEIPT COMMENTS Side Sewer Permit Sewer Latecomers LOTT Reserve Capacity Lacey General Facility Plan Check Fee Inspection Fee Front Footage Right of Way Access Permit TOTAL FEES Power of Attorney for annexation required. ( ) No ( ) Yes If yes, date submitted I have read the S.T.E.P inspection and testing process as described in the S.T.E.P. application attached and understand that if I have any questions, I am to contact City of Lacey Public Works Inspection at 491-5600. Applicant Signature Date General Notes: Two inspection visits will be allowed for testing. Follow-up inspections due to failed tests or lack of coordination between the plumbing and/or the electrical contractors shall be billed per each extra inspection. Water meter will not be set until after Final Inspection of STEP system is completed. Notify City a minimum 48 hours in advance at 491-5600 that installation is being made. Verify Electrical Permit prior to installing tank and controls. Pretest tank, piping and electrical prior to calling for inspection. Final Approval: Date: Comments: 02/14 D - 2

S.T.E.P. SEWER SYSTEM Inspection Checklist Service Address Lot Division Description Date Comments Initials Tank manufacturer Number Factory leakage test On-site leakage test Tank warranty Date manufactured ( ) Inspect tank prior to backfill Inspect piping prior to backfill Inspect service @ property prior to backfill Sewer warning tape and tracer wire Electrical warning tape Verify pump assembly H.P. Pressure test from tank to service Inlet tee installed Copy of electrical inspection by L & I Permit # Electrical inspection by City Permit # Pump operation Test high level and alarm Test on/off ball Check control box height 4-5 to center MAN, ON, OFF switch works Test redundant off and alarm Verify 20 amp branch circuit Initial amper reading Waterproof splicing in splice box Adequate conductor length in splice box Color coding in panel is correct As builts completed Easements completed Bill of Sale completed POA completed NOTES: Leakage test to 2 inches above base of tank riser - 2 hours (Maximum loss = 1 gallon. One gallon is 232.6 cubic inches or about.5 inch depth in 24 inch riser.) Pressure test at 150 pounds for 15 minutes. All electrical work shall be to NEC standards. Control box shall be located within three feet of the meter base or City approved location. All underground wiring shall be a minimum #14 stranded wire, color coded, in schedule 40 conduit, a minimum 18 inches deep, with warning tape in trench above conduit. ww/devapd06 D - 3 02/14

0 BUILDING,L\ND S. T.E.P. SITE PLAt'J Service Address---------------- Indicate the following information: Label existing or proposed. Drow to scale using 1"=1 a or 1 "=20'. 0 North Arrow D f'ronllng Street & 0 Bulldln9 foundations, Elevollon D Seal Slr el Name (Spot Tick or Contour) & Distance D Properly Boundary Lines D E1dslln9 osemenls To Loi Unes D Orlvewoy Locollon D Woler Meler 8t Waler 0 Proposed Septic Tank location Une LocaHon 0 Proposed Control Bcur Location 0 Arrows Showing Direction of Slope. 0 Sf[PAPP.OWG 0 05101

( BUILDING AND S. T. E.P. SITE. PLAl\J Service Address S_A_M_'P_L_5 lndicole the following information: label existing or proposed. Drow _/ to scale using 1"=10' or 1"=20'. M/ Norlh Arrow ~ f'ronllng Street ~ rl' Bulldlng f'oundotlons, Elevation M/ Scale Street Nome (Spot Tick or Conlour) & Distance ~/ Property Boundary Lines Existing Easements Ill Driveway location t t To Lot Lines Waler Meler & Waler Proposed Septic Tank Location Lin Location Proposed Conlrol Box Location Arrows Showing Dlreclfon of Slope f calt 1 =20 ~ cq. ':J"!; ~o :16' 0 sltc;trtc; Alllrl'K PAll\.Cl ~ 1'-' ':J~ RtsLdtli\.Ct w/2 car c.aragt 30' )(50' FLll\.Lslil~d Floor eltvattol'\. 10::2.5' 1-f' 1000 C'jAllo111. --t---. s nw sept:le Tlll'l.Ro. ---- - --_:;:. _ --- ---- - -- - - - -- -- -~ - -. - ---- - e.ustl111. 9 ~ - :S"tWer t fat.; - - Street NCB'\~.e - - --- - - - --- - - --------- ---------'l:::'- --- - 0 SJtPAPP SAMPLE.OWG D-3 05/01

After recording return document to: City of Lacey Public Works 420 College Street SE Lacey, WA 98503 Document Title: STEP Sewer Easement (Individual Form) Grantor(s) (Last name first, then first name and initials): 1. 2. 3. 4. 5. Additional name(s) on page of doc Grantee: City of Lacey Abbreviated Legal Description (i.e. lot, block, plat or section, township, range): Actual legal is on page of document. Assessor s Property Tax Parcel Number: Section, Township, Range: S, T N, R (E or W), W.M. Fronting Street: Cross Street: 02/14 D - 6

S.T.E.P. SEWER SYSTEM EASEMENT (individual form) THIS INDENTURE, made this day of, 20, between, hereinafter called Grantor(s), and the CITY OF LACEY, a Municipal Corporation, hereinafter called Grantee, WITNESSETH: For good and valuable consideration receipt of which is hereby acknowledged, the Grantor(s) hereby grant and convey to the Grantee, its successors and assigns a perpetual easement for operation, maintenance and repair of septic tanks, pump chambers, pressure sewer connection lines and pump electrical services, over, under, upon and through that certain real property situate and being in the County of Thurston, State of Washington, more particularly described as follows, to-wit: (Insert Legal Description) The width of the easement herein reserved shall be five feet each side of pipe and electrical lines as constructed. The width of the tank easement shall extend five feet beyond the edges of the tank. The Grantor waives any claim against the Grantee for damages to landscaping or other improvements located within the easement area. The owner shall maintain and is responsible for the house lateral connecting the tank to the house plumbing and inlet to the tank chamber The permanent rights herein granted to the Grantee shall continue in force until such time as the Grantee, its successors or assigns, shall permanently abandon the same and upon such removal or abandonment, all rights hereby granted shall terminate. IN WITNESS WHEREOF, this instrument has been executed the day and year first above written. (Grantor) (Grantor) STATE OF WASHINGTON ) ) ss COUNTY OF THURSTON ) I certify that I know or have satisfactory evidence that (is/are) the person(s) who appeared before me, and said person(s) acknowledged that (he/she/they) signed this instrument, and acknowledged it to be (his/her/their) free and voluntary act for the uses and purposes mentioned in the instrument. 02/14 D - 7

GIVEN under my hand and seal this day of, 20. NOTARY PUBLIC in and for the State State of Washington, residing at My commission expires: Accepted by the City of Lacey, Washington, this day of, 20. By: Director of Public Works STATE OF WASHINGTON ) ) ss COUNTY OF THURSTON ) On this day and year above, personally appeared before me,, to me known to be the Public Works Director of City of Lacey, a Municipal Corporation, who executed the foregoing instrument, and acknowledged the said instrument to be the free and voluntary act and deed of said Municipal Corporation for the uses and purposes therein mentioned and on oath states he/she is authorized to execute the said instrument. GIVEN under my hand seal this day of, 20. NOTARY PUBLIC in and for the State State of Washington, residing at My commission expires: 02/14 D - 8

After recording return document to: City of Lacey Public Works 420 College Street SE Lacey, WA 98503 Document Title: STEP Sewer System Easement (Corporate Form) Grantor(s) (Last name first, then first name and initials): 1. 2. 3. 4. 5. Additional name(s) on page of doc Grantee: City of Lacey Abbreviated Legal Description (i.e. lot, block, plat or section, township, range): Actual legal is on page of document. Assessor s Property Tax Parcel Number: Section, Township, Range: S, T N, R (E or W), W.M. Fronting Street: Cross Street: 02/14 D - 9

S.T.E.P. SEWER SYSTEM EASEMENT (corporate form) THIS INDENTURE, made this day of, 20, between (CORPORATE NAME), hereinafter called Grantor, and the CITY OF LACEY, a Municipal Corporation, hereinafter called Grantee, WITNESSETH: For good and valuable consideration receipt of which is hereby acknowledged, the Grantor hereby grants and conveys to the Grantee, its successors and assigns a perpetual easement for operation, maintenance and repair of septic tanks, pump chambers, pressure sewer connection lines and pump electrical services, over, under, upon and through that certain real property situate and being in the County of Thurston, State of Washington, more particularly described as follows, to-wit: (Insert Legal Description) The width of the easement herein reserved shall be five feet each side of pipe and electrical lines as constructed. The width of the tank easement shall extend five feet beyond the edges of the tank. The Grantor waives any claim against the Grantee for damages to landscaping or other improvements located within the easement area. The owner shall maintain and is responsible for the house lateral connecting the tank to the house plumbing and inlet to the tank chamber. The permanent rights herein granted to the Grantee shall continue in force until such time as the Grantee, its successors or assigns, shall permanently abandon the same and upon such removal or abandonment, all rights hereby granted shall terminate. IN WITNESS WHEREOF, said corporation has caused this instrument to be executed by its proper officers and its corporate seal (if any) to be hereunto affixed this day of, 20. (CORPORATE NAME) BY (Signature) BY (Signature) 02/14 D - 10

ITS (Title) ITS (Title) STATE OF WASHINGTON ) ) ss COUNTY OF THURSTON ) On the day of, 20, before me, a Notary Public in and for the State of Washington, duly commissioned and sworn, personally appeared (NAME(S)) to me known to be the (TITLE(S)) of (CORPORATE NAME) and acknowledged the said instrument to be the free and voluntary act and deed of said corporation, for the uses and purposes therein mentioned, and on oath stated that he/she/they is/are authorized to execute the said instrument and that the seal affixed (if any) is the corporate seal of said corporation. WITNESS my hand and official seal the day and year first above-written. NOTARY PUBLIC in and for the State State of Washington, residing at My commission expires: Accepted by the City of Lacey, Washington, this day of, 20. By: Director of Public Works ww/devapd02 02/14 D - 11

After recording return document to: City of Lacey Public Works 420 College Street SE Lacey, WA 98503 Document Title: STEP System Bill of Sale (Individual Form) Grantor(s) (Last name first, then first name and initials): 1. 2. 3. 4. 5. Additional name(s) on page Grantee: City of Lacey Abbreviated Legal Description (i.e. lot, block, plat or section, township, range): Actual legal is on page of docu m en t. Assessor s Property Tax Parcel Number: Section, Township, Range: S, T N, R (E or W), W.M. Fronting Street: Cross St reet : 02/ 14 D - 12

S.T.E.P. SYSTEM BI LL OF SALE (individual form) THIS BILL OF SALE is m ade an d execu t ed t h is day of, 20, by an d bet ween an d, hereinafter called the grantor(s), and the City of Lacey, a Municipal Corporation, h er einaft er called t h e gr an t ee. WITNESSETH: That the grantor(s), for good and valuable consideration, the receipt of which is h er eby ack n owledged, h er eby con vey, set over, assign and warrant to the City of Lacey t h e following descr ibed per son al pr oper t y situ at ed in Th u r st on Cou n t y, State of Washington, TO WIT: The S.T.E.P. system service lateral from the tank to the sewer main, tank, pump and pump controls lying within the following described parcel: (insert legal description) Th e gr an t or (s) h er eby war r an t s t h at h e/ sh e/ t h ey ar e t h e sole owner (s) of all t h e pr oper t y above con veyed, h e/ sh e/ t h ey h ave t h e fu ll power t o con vey t h e sam e, and that he/ she/ they will defend the title of said grantee against any and all persons lawfully making claims thereto. Dat ed th is day of, 20. (grantor) (grantor) STATE OF WASHINGTON ) ) ss COUNTY OF THURSTON ) I certify that I know or have satisfactory evidence that (is/ are) t h e per son (s) who appear ed befor e m e, an d said per son (s) ack n owledged t h at (he/ she/ they) signed this instr u m en t, an d ack n owledged it t o be (his/ her/ their) free and voluntary act for the uses and purposes mentioned in the instrument. Given un der my han d an d seal th is day of, 20. Notary Public in and for the State of Washington, residing at. My com m ission expir es: Syst em accept ed by t h e Cit y of Lacey, Wash in gt on, t h is day of, 20. By: Director of Public Works 02/ 14 D - 13

After recording return document to: City of Lacey Public Works 420 College Street SE Lacey, WA 98503 Document Title: STEP System Bill of Sale (Corporate Form) Grantor(s) (Last name first, then first name and initials): 1. 2. 3. 4. 5. Additional name(s) on page Grantee: City of Lacey Abbreviated Legal Description (i.e. lot, block, plat or section, township, range): Act u al legal is on page of docu m en t. Assessor s Property Tax Parcel Number: Section, Township, Range: S, T N, R (E or W), W.M. Fronting Street: Cross St reet : 02/ 14 D - 14

S.T.E.P. SYSTEM BI LL OF SALE (corporate form) THIS BILL OF SALE is m ade an d execu t ed t h is day of, 20, by and bet ween (cor por at e n am e), h er ein after called t h e gr an t or, and the City of Lacey, a Municipal Corporation, hereinafter called the grantee. WITNESSETH: That the grantor, for good and valuable consideration, the receipt of which is hereby ack nowledged, hereby convey, set over, assign and warrant to the City of Lacey the following described personal property situated in Thurston County, State of Washington, TO WIT: The S.T.E.P. system service lateral from the tank to the sewer main, tank, pump and pump controls lying within the following described parcel: (insert legal description) IN WITNESS WHEREOF, said corporation has caused this instrument to be executed by its proper officers and its corporate seal (if any) to be hereu nto affixed th is day of, 20. (corporate name) BY BY (Signatu r e) (Signatu r e) ITS (Title) ITS (Title) STATE OF WASHINGTON ) ) ss COUNTY OF THURSTON ) On t h e day of, 20, befor e m e, a Not ar y Pu blic in and for the State of Washington, duly commissioned and sworn, personally appeared t o m e k n own t o be t h e (t it le(s)) of (cor por at e n am e) an d ack n owledged t h e said in st r u m en t to be the free and voluntary act and deed of said corporation, for the uses and purposes therein mentioned, and on oath stated that he/ she/ they is/ are au thorized to execu te the said instrument and that the seal affixed (if any) is the corporate seal of said corporation. WITNESS my hand and official seal the day and year first above-written. Notary Public in and for the State of Washington, r esidin g at. My com m ission expir es:. Syst em accept ed by th e Cit y of Lacey, Wash in gt on, th is day of, 20. By: Director of Public Works 02/ 14 D - 15

SPECIAL POWER OF ATTORNEY FOR ANNEXATION KNOW ALL PERSONS BY THESE PRESENTS, that the undersigned, herein referred to as the Developers, in consideration of the CITY OF LACEY granting to the Developers the right to connect to the CITY OF LACEY S sewerage and water facilities required to serve the legal description of which is attached hereto and incorporated herein by reference, do hereby: Grant and convey to the LACEY PUBLIC WORKS DIRECTOR or his successor in interest or designee; A special power of attorney to exercise any and all rights said Developers, their heirs or assigns and any successors in interest to said Developers, including any purchasers, mortgage holders, lien holders or other persons who may claim an interest in said property hereinafter referred to as successors in interest to accomplish the following: 1. To petition to the City of Lacey for annexation of any and all of the lots or other property which petition shall conform to the provisions of Paragraph 2 herein. 2. To accomplish all steps necessary or proper for the annexation under the laws of the State of Washington, Thurston County and the City of Lacey for annexation of the property to the City of Lacey with a zoning consistent with the development and an assumption of no more than a fair share of the City s indebtedness. 3. To sign any and all letters, petitions and other documents necessary to accomplish said annexation on behalf of the Developers or any successors in interest as defined above. This power of attorney is granted in consideration of the City providing the abovedescribed access to sewerage and water facilities and shall be a power coupled with an interest which may not be terminated except at such time as the project is no longer served by the sewerage facilities through the CITY OF LACEY or the CITY OF LACEY S water facilities. 02/14 D - 16

This power of attorney touches and concerns the real property and so long as the development is served by sewerage facilities through the CITY OF LACEY or the CITY OF LACEY S water facilities, shall bind the land and shall run with the land binding all who derive an interest herein. This power of attorney shall be recorded in the Thurston County Auditor s Office and shall be referenced on any deed or other instruments conveying any interest in. Dated, 20. STATE OF WASHINGTON ) ) ss. County of Thurston ) This is to certify that on, 20 before me, a Notary Public in and for the State of Washington, duly commissioned and sworn, personally appeared to me known to be the person(s) described in and who executed the foregoing Special Power of Attorney, and acknowledged to me that they signed and sealed the same as their free and voluntary act and deed, for the uses and purposes therein mentioned. IN WITNESS WHEREOF, I have hereunto set my hand and affixed my official seal the day and year first above-written. Notary Public in and for the State of Washington, residing at ww/devapd05 02/14 D - 17

STEP SYSTEM PLAT EASEMENT PROVISIONS A PERPETUAL EASEMENT IS HEREBY RESERVED FOR AND GRANTED TO THE CITY OF LACEY, ITS SUCCESSORS AND ASSIGNS, FOR OPERATION, MAINTENANCE, AND REPAIR OF ANY OR ALL PORTIONS OF THE SEPTIC TANK EFFLUENT PUMPS (S.T.E.P.) SYSTEM INCLUDING BUT NOT RESTRICTED TO: SEPTIC TANKS, PUMP CHAMBERS, PRESSURE/GRAVITY SEWER CONNECTION LINES AND PUMP STATUS PANEL, OVER, UNDER AND THROUGH THE LAND HEREBY PLATTED. THE PURPOSE OF THE EASEMENT IS TO PROVIDE ACCESS FOR CITY OFFICERS AND EMPLOYEES TO THE CITY OWNED PORTION OF THE S.T.E.P. SANITARY SEWER SYSTEMS. THE WIDTH OF THE EASEMENT HEREIN RESERVED SHALL BE FIVE FEET EACH SIDE OF PIPE AND ELECTRICAL LINES AS CONSTRUCTED. THE WIDTH OF THE TANK EASEMENT SHALL EXTEND FIVE FEET BEYOND THE EDGES OF THE TANK. THE OWNER SHALL MAINTAIN AND IS RESPONSIBLE FOR THE HOUSE LATERAL CONNECTING THE TANK TO THE HOUSE PLUMBING AND INLET TO THE TANK CHAMBER. THE CITY OF LACEY SHALL HAVE THE RIGHT TO TEMPORARILY UTILIZE SUCH AREA BEYOND THE EASEMENT AREA DESCRIBED ABOVE THAT IS NECESSARY FOR THE OPERATION, MAINTENANCE AND REPAIR ACTIVITIES ON THE S.T.E.P SYSTEM. IT IS POSSIBLE THAT LANDSCAPING WITHIN THE ABOVE EASEMENT RIGHT-OF-WAY MAY BE DAMAGED DURING THE PERFORMANCE OF OPERATION AND MAINTENANCE ACTIVITIES. THE OWNER WAIVES ANY CLAIM AGAINST THE CTIY FOR DAMAGE TO SAID ITEMS IN THE CASE WHERE WORK BY THE CITY IS DONE IN A REASONABLE MANNER. THE OWNER ALSO WAIVES ANY CLAIM AGAINST THE CITY FOR DAMAGES GENERALLY WHICH ARISE FROM ACTS OF GOD OR OF THIRD PARTIES NOT INVOLVING FAULT BY THE CITY OF LACEY. THIS EASEMENT SHALL BE CONSIDERED AN ENCUMBRANCE WHICH TOUCHES AND CONCERNS THE LAND ABOVE DESCRIBED, AND BINDS OWNERS, TRANSFEREES, DONEES, SUCCESSORS AND ASSIGNEES IN INTEREST IN THE SAME MANNER AS IT BINDS OWNERS HEREIN. NOTE: THE ABOVE EASEMENT PROVISIONS SHALL BE SHOWN ON THE FACE OF THE FINAL PLAT, VERBATIM. LETTERING SHALL NOT BE LESS THAN 0.13 (1/8) INCH IN HEIGHT. ww/dev94 02/14 D - 18

STEP Sewer Service User Information Sept ic Tan k Effluen t Pu m p (STEP) sewer syst em s ar e being inst alled wher e sewer service is required, but conventional gravity sewers are too costly to install. STEP systems are comprised of a special septic tank, a high quality pump, and a pressurized piping system. Wastewater (sewerage) enters the tank from the building using a normal gravity flow. STEP systems differ from a conventional gravity sewer as liquids and solids are separated. Liquids are pumped into a pressur ized sewer line for t r eat m en t, while solids remain in the tank to await pumping by a City of Lacey maintenance team. Depen ding on u sage, solids will on ly n eed t o be pu m ped ever y five t o t en year s. Residen t s n eed t o be awar e t h at STEP t an k s h ave special operation and maintenance r equ irem en t s. Am on g t h ese ar e: Access to the tank riser lids, which remain slightly above the ground, needs to be maintained. Access to the system control panel must be maintained. This allows city teams to perform routine maintenance and tests on your system. Fencing areas around your control panel can make it difficult to find when service is required. Th e t an k is n ot design ed for su ppor t ing h eavy loads. Please DO NOT dr ive over t h e t an k with wheeled veh icles. Con t r act or s working for you should be advised of this hazard. Some residents have found that placing attractive shrubs near the tank minimizes this risk. STEP tanks will not support a trailer or boat. Power t o t h e syst em is pr ovided by t h e r esiden t. In t h e even t of a temporary power loss, t h e t an k is design ed t o h old wast es for pu m ping when power is r est or ed. The tank has the ability to store a limited amount of waste. If power is not restored, please restrict your use of water such as showering, dishwashing, flushing the toilet, rinsing in the sink, or using the clothes washer. Emergency pumping can be arranged by calling 491-5644. An alarm on the control panel will sound and/ or a red light will illuminate on the panel if liquids reach an abnormal level. This can be caused by a number of problems, including a pump failure. From the time that this situation occurs, the tank has roughly 24 hours of capacity left (under normal use.). When you have such an incident, curtail water use and call the City at 491-5644. Do not turn off the main breaker switch for the system as this can worsen the problem. The City is not r espon sible for dam ages cau sed by a sewer age back u p when wat er u se is not minimized after an alarm. As with all sewer serviced buildings, maintenance of piping bet ween t h e t an k an d t h e bu ilding ar e t h e r espon sibility of t h e r esiden t or pr oper t y owner. Excessive use of a garbage disposal will clog the system. We encourage composting food materials instead of using a garbage disposal. Depending upon the circumstances, damage resulting from clogs can be charged to the resident. 02/ 14 D - 19

Disposing grease into the system will also clog the system and can result in costly repairs for both the resident and the City. Residents must refrain from pouring gr ease int o drains or toilets. Depending upon the circumstances, damage resulting from clogs can be ch ar ged t o t h e r esiden t. Digging near the tank can damage the system and cause injury. Other utilities can cause similar results. Before digging, please call for a utility locate at 1-800-424-5555. City of Lacey work teams carry proper identification. Residents should ask for identification before admitting people into their home, office or workplace. Identification can be verified by calling 491-5644 or 459-4333. Only sanitary wastewater shall be discharged into the tank. Roof drains and other stormwater sources are strictly prohibited. Operation and maintenance of the tank, pump, and pump controls shall be the responsibility of the City only after the system has been inspected and approved, the on e year war r an t y per iod has expired an d an easem en t an d Bill of Sale is gr an t ed t o t h e City. If you have any question about your STEP system, please call 491-5644. ww/ devapd04 02/ 14 D - 20