Department of Planning & Development Services

Similar documents
Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

ARTICLE 900 PLAT AND PLAN REQUIREMENTS

Department of Planning & Development Services

APPLICATION PROCEDURE

CHAPTER 26 PLANNING AND ZONING ARTICLE VII. MOBILE HOMES AND RECREATIONAL VEHICLE (RV) PARKS. Recreational Vehicle (RV) Park Development Standards

Department of Planning & Development Services

CITY OF HOLLYWOOD. Technical Advisory Committee Submittal Checklist. Guide to TAC Submittal Checklist. General Requirements:

JEFFERSON COUNTY, ALABAMA

Special Land Use. SLU Application & Review Standards

ARTICLE 15 - PLANNED UNIT DEVELOPMENT

FINAL SUBDIVISION AND LAND DEVELOPMENT PLAN CHECKLIST. Plan Name. Applicant's Name:

Department of Planning & Development Services

UPPER MOUNT BETHEL TOWNSHIP NORTHAMPTON COUNTY, PENNSYLVANIA

CHAPTER 25 REVIEW AND APPROVAL OF SITE CONDOMINIUM AND CONDOMINIUM PROJECTS

ARTICLE IV: DEVELOPMENT STANDARDS

Department of Planning & Development Services

Department of Planning & Development Services

Department of Planning & Development Services

I. Requirements for All Applications. C D W

AN ORDINANCE TO AMEND SECTION OF THE RAPID CITY MUNICIPAL CODE TO ALLOW FOR ADMINISTRATIVE DISSOLUTION OF PLANNED DEVELOPMENTS

Development Plan DP13-3 (Arlington Lofts) Planning and Zoning Meeting Date: Document Being Considered: Ordinance

Department of Planning & Development Services

APPLICATION FOR MAJOR SUBDIVISION APPROVAL (PRELIMINARY PLAT)

ARTICLE 900 PLAT AND PLAN REQUIREMENTS

BRIDGETON SUBDIVISION APPLICATION CHECKLIST

(a) Commercial uses on Laurel Avenue, abutting the TRO District to the

SUBDIVISION AND LAND DEVELOPMENT. 185 Attachment 20

City of Midland Application for Site Plan Review

Department of Planning & Development Services

Application for Sketch Plan Review

CHAPTER 3 PRELIMINARY PLAT

PLANNED DEVELOPMENT DISTRICT STANDARDS. Cadence Site

Department of Planning & Development Services

SEE PAGE 4 FOR 2018 CALENDAR OF MEETINGS CITY OF BROOKFIELD PLAN COMMISSION AND PLAN REVIEW BOARD PROCEDURES AND APPLICATION CHECKLIST

Department of Planning & Development Services

Section Preliminary Plat Checklist and Application Forms

TOWN OF NORTHWOOD, NEW HAMPSHIRE

TOWN OF MELBOURNE BEACH 2016 DEVELOPMENT APPLICATION

CITY OF PAPILLION PLANNING COMMISSION STAFF REPORT NOVEMBER 18, 2015 AGENDA BUCKY S CONVENIENCE STORES SPECIAL USE PERMIT SUP

Waseca County Planning and Zoning Office

Community Development

ORDINANCE NO. Be it ordained by the City Council of the City of Abilene, Texas:

DIVISION 2 - CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS

Site Plan Application

CHAPTER 29 ARTICLE 8. 20,000 sf 30,000 sf 100,000 sf (with approval by Special Use Permit according to Sec

City of Corinth. Development Application Handbook. Date: March 12, 2018

APPLICATION PROCESS FOR PROJECT REVIEW

Administrative Plat Application Form

MAJOR SUBDIVISION PRELIMINARY PLAT CHECKLIST

ZA and ZA Zoning Change and Concept / Site Plan Preliminary Plat Delta Southlake Center

CITY OF GROVER BEACH COMMUNITY DEVELOPMENT DEPARTMENT Tentative Map Checklist

CHAPTER 14 SPECIAL DEVELOPMENTS

Preliminary Subdivision Application (Major) (Four (4) lots or more)

COMMERCIAL SITE PLAN & CONDITIONAL USE PERMIT REVIEW PROCESS & CHECKLIST

TOWN OF EASTCHESTER BUILDING AND PLANNING DEPARTMENT PLANNING BOARD APPLICATION PACKAGE SUBDIVISIONS

MINOR SUBDIVISION PLAT CHECKLIST

New Private Way Ordinance Westbrook Planning Board Workshop , Planning Board Public Hearing Definitions

PLANNING BOARD CITY OF CONCORD, NH MINOR SUBDIVISION CHECKLIST

M E M O R A N D U M. Meeting Date: October 23, Item No. F-1. Planning and Zoning Commission. Daniel Turner, Planner I

CITY OF DERBY. MEETING OF THE PLANNING COMMISSION REGULAR MEETING June 19, :30 PM

DETAILED GRADING PLAN CHECKLIST (TEARDOWN/REDEVELOPMENT)

GENERAL PLANNING APPLICATION FORM

Residential Major Subdivision Review Checklist

géãç Éy VtÇtÇwt zât 5440 Routes 5 & 20 West Canandaigua, NY Phone: (585) / Fax: (585)

Tentative Map Application Review Procedures

TOWN OF ROXBURY PLANNING BOARD

COUNTY OF ALBEMARLE APPLICATION FOR RURAL SUBDIVISION

TOWNSHIP OF DOYLESTOWN APPLICATION FOR REVIEW OF SUBDIVISION OR LAND DEVELOPMENT PROPOSAL. Please PRINT; all information MUST be filled out completely

ARTICLE 7 UTILITIES AND EASEMENTS

Level III Preliminary and Final Site Plans Development Review Application Portland, Maine Planning and Urban Development Department Planning Division

PRELIMINARY PLAT CHECK LIST

SUBMITTAL REQUIREMENTS: The number indicates the number of copies for submittal (if applicable).

Medical Marijuana Special Exception Use Information

PLANNING BOARD REPORT PORTLAND, MAINE

TOWN OF LEWISTON PLANNING BOARD APPLICATION

WRIGHT TOWNSHIP Ottawa County 1565 Jackson Street, P.O. Box 255, Marne, Michigan 49435

Planned Residential Development ( PRD ) Application

Township of Little Egg Harbor Planning Board 665 Radio Road Little Egg Harbor, New Jersey Phone: ext. 221 Fax:

DEVELOPMENT POLICY INFRASTRUCTURE GUIDELINES FOR NEW DEVELOPMENT

GENERAL CONDITIONS APPLYING TO SUBDIVISIONS APPROVED BY THE PLANNING BOARD OF THE TOWN OF BETHLEHEM ALBANY COUNTY - NEW YORK

E L M E R B O R O U G H L A N D U S E B O A R D APPLICATION COVER SHEET (to be completed for all applications and appeals)

SECTION 4: PRELIMINARY PLAT

Residential Minor Subdivision Review Checklist

CONDITIONAL USE PERMIT APPLICATION FOR AN EXCAVATION/BORROW PIT INSTRUCTIONS

Initial Subdivision Applications Shall Include the Following:

SUBDIVISION, PLANNED UNIT DEVELOPMENT, PLANNING APPROVAL, ZONING AMENDMENT, & SIDEWALK WAIVER REQUEST STAFF REPORT Date: February 17, 2010

M E M O R A N D U M. Planning and Zoning Commission. Daniel Turner, Planner I

Transcription:

Department of Planning & Development Services S T A F F R E P O R T December 30, 2015 CASE NO: PROJECT: EXECUTIVE SUMMARY: REQUEST DETAILS: ZA15-136 Site Plan for Ward Retail Building On behalf of Donnie Ward, G&A Consultants is requesting approval of a Site Plan for Ward Retail Building on property described as Lot 34, F. Throop No. 1511 Addition, and addition to the City of Southlake, Tarrant County, Texas and located at 2199 E. Dove Road, Southlake, Texas. Current Zoning: C-1 Neighborhood Commercial District. SPIN Neighborhood #4. G&A Consultants is requesting Site Plan approval for an approximately 7,316 square foot commercial building. The two story structure will sit on the northeast corner of an approximately 0.848 acre property located at the intersection of E Dove Road and N Kimball Avenue. The structure is designed for multiple uses, including (as shown) a dry cleaner, coffee shop with kitchen, and office space on the first floor; and on the second floor, office space and an outdoor patio. Parking is provided consistent with each use, and building design conforms to the Residential Adjacency Overlay regulations. The applicant is requesting one variance, which is detailed below. A renewal of the Specific Use Permit for Tropical Sno shaved ice stand on the same property is requested in conjunction with this application as ZA15-147. Site Data Summary Chart Proposed Site Plan Existing Zoning C-1 Neighborhood Commercial District Land Use Designation Retail Commercial Gross Acreage.85 Number of Proposed Lots 1 Area of Open Space (sf) 14,661 Percentage of Open Space (15% min.) 39.74% Area of Impervious Coverage (85% max) 60.26% Proposed Building Area (sf) 3,659 (footprint) Number of Stories 2 Maximum Building Height (ft.) Approx. 32 Required Parking (14 for office/retail) + (14 for coffee shop) + (5 for cleaners) = 33 Provided Parking 39 ZA15-136

Variances Requested 1. Driveway separation The applicant plans to utilize two existing drive approaches for the development. Neither approach maintains the 200 foot required separation from the intersection of Dove Road and Kimball Avenue. Because the property does not have 200 feet of frontage on either the north or east property frontages, and because the driveways are existing, the applicant requests a variance to allow driveway spacing under 200 feet from the intersection of Dove Road and Kimball Avenue. 2. Tree preservation The applicant plans to remove two existing trees on site, which comprise the large majority of existing tree coverage. The tree preservation ordinance requires that at least 70% of tree canopy coverage be maintained in cases where less than 20% of the total site is currently covered by tree canopy. Because the existing overhead easement and drive approaches limit the manner in which the property could be developed while preserving the trees, the applicant requests a variance to allow the trees to be removed. ACTION NEEDED: 1) Conduct a Public Hearing 2) Consider Site Plan Approval Request ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plans and Support Information Link to PowerPoint (D) Site Plan Review Summary No. 1, dated December 9, 2015 (E) Surrounding Property Owners Map (F) Surrounding Property Owners Responses (G) Full Size Plans (for City Council Members Only) STAFF CONTACT: Dennis Killough (817) 748-8072 David Jones (817) 748-8070 ZA15-136

BACKGROUND INFORMATION OWNER: APPLICANT: PROPERTY SITUATION: LEGAL DESCRIPTION: LAND USE CATEGORY: CURRENT ZONING: HISTORY: CITIZEN INPUT: SOUTHLAKE 2030: Donnie Ward G&A Consultants 2199 E. Dove Road Lot 34, F. Throop No. 1511 Addition Retail Commercial C-1 Neighborhood Commercial District On January 27, 2012, demolition permits were issued for the previous one story brick and metal commercial building (1299 E Dove Road) and one story brick building (1500 N Kimball Avenue). The buildings were utilized by a variety of businesses, including an office, cleaners, a video store, and a salon. A SPIN Town Hall Forum has not been held for the proposed Site Plan. Consolidated Future Land Use The Southlake 2030 Consolidated Future Land Use Plan designates this development area as Retail Commercial. The Retail Commercial category is a lower- to medium-intensity commercial category providing for neighborhoodtype retail shopping facilities and general commercial support activities. It is intended to provide limited local retail and/or office uses which serve neighborhoods in close proximity. It is intended that all uses in this category will be compatible with adjacent single family uses, thereby maintaining the Attachment A ZA15-136 Page 1

character and integrity of existing neighborhoods. This category is intended to encourage comprehensively planned developments. In areas where the Retail Commercial designation is adjacent to residentially zoned properties or areas with a residential designation on the Land Use Plan, lower intensity activities such as office or office-related uses should be planned adjacent to the residential uses. Other suitable activities are those permitted in the Public Parks/Open Space, Public/Semi-Public, and Office Commercial categories previously discussed. As proposed, this Site Plan seems to be consistent with the Future Land Use Plan. Land Use Mix*: The percentages below for the land use mix in the Retail Commercial category are intended only to be guidelines, and greater flexibility may be appropriate under site specific conditions. Land Use Type Percentage Flexibility Retail 65% ±35% Office 20% ±20% Open space 10% ±10% Civic use 5% ±5% Total 100% *These percentages are not regulatory and should only be used as a guide TRANSPORTATION ASSESSMENT: Area Road Network and Conditions The property has approximately 210 feet of frontage along the northern boundary adjacent to E Dove Road. This road is improved with asphalt surface and an existing right turn lane. The property has approximately 150 feet of frontage along the eastern boundary adjacent to N Carroll Avenue, a fully improved street with four lanes and center medians south of Dove Road. Traffic Impact The development was found not to meet the traffic impact threshold necessary for a Traffic Impact Analysis. TREE PRESERVATION: The development as proposed does not meet tree preservation requirements. A site with less than 20% tree canopy coverage is required to preserve at least 70% of its coverage post-development. A 26 caliper American Elm and a 25 caliper Cottonwood comprise the majority of existing coverage on the site. Both trees are proposed for removal. In order to remove the trees as proposed, City Council must grant the applicant a variance from the requirements of Tree Preservation Ordinance no. 585. STAFF COMMENTS: Attached is Site Plan Review Summary No. 1, dated December 9, 2015. N:\Community Development\MEMO\2015 Cases\136 - SP - Ward Retail Bldg Attachment A ZA15-136 Page 2

Attachment B ZA15-136 Page 1

Plans and Support Information Proposed Site Plan Attachment C ZA15-136 Page 1

Project Narrative Attachment C ZA15-136 Page 2

Conceptual Elevations: North Elevation East Elevation Attachment C ZA15-136 Page 3

West Elevation South Elevation Attachment C ZA15-136 Page 4

Tree Preservation Plan Attachment C ZA15-136 Page 5

Landscape Plan Attachment C ZA15-136 Page 6

SITE PLAN REVIEW SUMMARY : ZA15-136 Review No.: One Date of Review: 12/09/15 Project Name: Site Plan Ward Retail/Commercial Building APPLICANT: Justin L Lansdowne E.I.T. G&A Consultants, LLC 144 Old Town Boulevard North, Suite 2 2010 E Dove Road Argyle, Texas 76226 Southlake, Texas 76092 OWNER/DEVELOPER: Donnie Ward ATA Construction Phone: (940) 240-1012 Phone: (817) 988-0784 E-mail: Justin@gacon.com E-mail: ataconst@aol.com CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 11/30/15 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT DAVID JONES AT (817) 748-8070. 1. Standing seam metal roof must have a non-metallic factory applied matte finish. 2. Please revise the height shown in the Site Data Summary Chart to reflect the height per the definition in Zoning Ordinance No. 480, Section 4. The height is defined as the average height of the highest gable on a pitched roof. The height of the building appears to be approximately 32. 3. Provide a 4:1 slope setback exhibit which appears more architectural. The provided exhibit is easily mistaken for a utility profile. 4. Adjust parking requirement table to reflect that only 1 stall per 200 spaces is required for a dry cleaning (personal services) establishment. 5. Adjust driveway to south property so that the existing 8 Lacebark Elm is not imperiled by the future extension of the drive. 6. A common access easement must be drawn up and recorded to allow passage between this property and the Paul Wagner property to the south. Please submit a copy of the proposed instrument to the City for review. 7. Provide north arrows on floor plan drawings. 8. Per Ordinance No. 557-A and section 43.13 of the Southlake Land Development Code, at least 80% of each building façade shall consist of masonry materials. Provide calculation showing percentage of masonry materials proposed for each exterior wall. Masonry material is defined as brick, stucco, plaster, stone, rock or other masonry material of equal characteristics. Synthetic products such as EIFS, hardi plank, or similar shall not be considered a masonry material. Any variance request from these regulations should be submitted with this application. 9. No use or operation shall produce direct or indirect illumination across a residential property line except in compliance with Ordinance No. 693-C. Submit a lighting schematic which shows layout of all proposed exterior fixture locations, foot candle data, and a plot demonstrating intensities and uniformities, including luminance and illumination data at the boundaries of neighboring properties in Attachment D ZA15-136 Page 1

foot candles. Any variance request from these regulations should be submitted with this application. 10. The existing drive approaches do not meet the minimum 200 foot setback from the intersection of Kimball and Dove Rd (Driveway Ordinance no. 634.) A variance request has been submitted. 11. Stacking space on the northern drive approach is inadequate to meet the 28 foot minimum requirement (Ord. 634). As the development is overparked, staff suggests removing the northwesternmost parking stall to lengthen stacking space. 12. Indicate whether the existing wood utility poles will remain on the property as-is, be moved, or be buried. 13. Show elevation and detail of fencing proposed for west property boundary. Kelly Clements Assistant Fire Marshal (817) 748-8671 kclements@ci.southlake.tx.us GENERAL COMMENTS: Fire Marshal Comments 1. Hydrants required at a maximum spacing of 500 feet for commercial locations that contain sprinkled buildings. (Additional fire hydrant will be required within the property if the building is unsprinkled) 2. Fire lanes require a minimum 30 foot inside turn radius and a minimum 54 foot outside turn radius. (Per 2012 I.F.C. Sec. 503.2.4) 3. The required backflow protection (double check valve) for the sprinkler system can be located on the riser if the riser is within 100 feet of the water main. If the riser is further than 100 feet from the main, the double check valve shall be in a pit. Riser rooms shall be a minimum of 5 X5 if the double check is not located on the riser, or a minimum of 6 X6 if it is on the riser. 4. Fire department sprinkler connections, FDC, are to be a five inch Storz connection with a 30 degree down elbow and a Knox locking cap. 5. The Fire Department Connection for the sprinkler system must be within 100 feet of a fire hydrant, and within 50 feet of fire lane access. Keith Martin Landscape Administrator (817) 748-8229 kmartin@ci.southlake.tx.us Landscape Administrator Comments 1. A Tree Conservation Plan is required to be submitted with the submittal of a Site Plan. Please submit the required Tree Conservation Plan meeting the requirements of the Tree Preservation Ordinance 585-D. 2. There are two (2) existing trees in the eastern middle portion of the lot that are not shown on any of Attachment D ZA15-136 Page 2

the plans. One is an Elm tree and the other is Cottonwood. * Information required for Tree Conservation Plan: i. Identification of Critical Environmental Features of the site: A. All individually protected trees B. Existing streams, drainage creeks, ponds, and other water bodies (if any) ii. Tree Survey or alternative to a tree survey iii. 2-foot contour map of the site iv. Protected trees within the tree preservation area including tree size and type v. Critical Root Zones of groups of trees vi. Critical Root Zones for individual trees required for site plans only vii. Boundaries of any tree preservation areas as identified in the ERP Map viii. Identification of areas of environmental constraints not suitable for development ix. Identification of areas of minimal environmental constraints that are suitable for development x. Areas of encroachment into Critical Environmental Features identified on the site xi. Clear delineation, for each protected tree, of whether the tree will be preserved after the proposed development is constructed, altered due to proposed improvements, or could potentially be saved based upon site specific conditions xii. xiii. xiv. xv. xvi. Stream/Creek buffers, if any Detailed site plan of all proposed improvements. (All proposed improvements shall be required to be shown only at the site plan stage for all development. Preliminary plats shall, however, show building setbacks and general location of buildings and infrastructure.) Setbacks, building lines, and buffer yards The names, addresses and telephone numbers of those persons or entities who own the property and those persons or entities filing the application Such additional information as the Administrative Official may reasonably require given the particular characteristics of the property. Except as provided by subsection 7.2.b. of the Tree Preservation Ordinance, a Tree Conservation Analysis or Tree Conservation Plan shall be approved if it will preserve existing tree cover in accordance with the percentage requirements established by Table 2.0. If the property has previously received a tree permit related to development, the percentage of existing tree cover at the time the first such permit was issued shall be used to calculate the minimum existing tree cover that must be preserved under this section. Table 2.0 Existing Tree Cover Preservation Requirements Percentage of existing tree cover on the entire site Minimum percentage of the existing tree cover to be preserved* 0% 20% 70% 20.1 40% 60% 40.1% - 60% 50% 60.1% - 80% 40% 80.1% - 100% 30% *The minimum percentage of existing tree cover to be preserved shall exclude any area in public rights-of-way as approved by City Council LANDSCAPE COMMENTS: 1. Parking lot islands shall have a minimum width of 12 back-to-back if curbed or 13 edge-to-edge if no curb is intended, and shall be equal to the length of the parking stall. 2. All parking planter islands in parking areas shall contain a minimum of one (1) canopy tree with the remaining area in shrubs, ground cover, ornamental grasses or seasonal color. Planter islands which Attachment D ZA15-136 Page 3

have light poles for lighting the parking areas may substitute two (2) understory/accent trees for the required canopy tree. 3. All of the canopy trees are proposed to be 3 caliper. At least 50% of the canopy trees are required to be 4 caliper. 4. Existing tree credits are proposed to be taken for required west and south bufferyard landscaping. The existing trees being taken credit for in the south bufferyard do not look to be fully on the developing property. In order to take existing tree credits for required development landscaping, the existing trees taken credit for must be growing on the developing property and be healthy condition. 5. Canopy Trees cannot be planted within the overhead electrical transmission easement which runs across the property. Relocate the canopy trees shown within the easement to somewhere outside of the easement. Accent trees can be planted within the parking islands which are within the easement. Two (2) accent trees may be planted within the islands to meet the parking island canopy tree requirement. 6. The Chaste Trees are incorrectly labeled. 7. Please provide a color landscape plan. * Indicates informational comment. # Indicates required items comment. Steve Anderson, P.E. Civil Engineer (817) 748-8101 sanderson@ci.southlake.tx.us Engineering/Public Works Comments GENERAL COMMENTS: 1. This review is preliminary. Additional requirements may be necessary with the review of civil construction plans. 2. NEW REQUIREMENT: Submit with Civil Construction Plans a Retaining Wall Layout sheet. 3. Retaining walls greater than 4-feet including the footing shall require structural plans prepared by a registered engineer in the State of Texas. Retaining walls shall require a permit from the Building Inspections Department prior to construction. 4. Label curb return radius for the proposed drive. Curb return radii for driveways shall be 30 minimum. 5. Fire lane radii shall be 30 minimum. * Street intersections shall comply with TDLR/ADA accessibility standards. * Sight distances shall comply with AASHTO guidelines on adjacent collectors and arterials. * Sidewalk widths shall conform to the Southlake Pathways Plan. * Use the City of Southlake GPS monuments whenever possible. Monument locations can be Attachment D ZA15-136 Page 4

found on the City of Southlake website: http://www.cityofsouthlake.com/index.aspx?nid=266 EASEMENTS: 1. Provide all necessary easements for water, sanitary sewer and drainage. Easements shall be 15 minimum and located on one lot not centered on the property line. A 20 easement is required if both storm sewer and sanitary sewer will be located within the easement. * Water and sanitary sewer cannot cross property lines without being in an easement or right of way. All waterlines, sanitary sewer and storm sewer in easements or right of ways must be constructed to City standards. WATER COMMENTS: 2. Commercial and industrial developments require fire hydrant spacing of 300 maximum for nonsprinkled buildings or 600 for sprinkled buildings. * The size of the water service tap must match the size of the meter. There are no reducers allowed before the meter on the public side. A one inch meter must have a one inch tap, etc. * Water meters and fire hydrants shall be located in an easement or right of way. * Fire lines shall be separate from service lines. SANITARY SEWER COMMENTS: 1. Add a note: Private sanitary sewer services need a plumbing permit and must be inspected by building inspections prior to burial. DRAINAGE COMMENTS: 1. The storm drain system recently constructed with the Kimball Avenue widening project accounts for developed conditions runoff. However, the Kimball Avenue plans do not account for the runoff flowing into Dove Road, continuing east along Dove Road and around the corner, south to the inlet. Please direct the on-site runoff directly to the inlet or capture and carry the runoff in an enclosed system. * Discharge of post development runoff must have no adverse impact on downstream properties and meet the provisions of Ordinance No. 605. INFORMATIONAL COMMENTS: * Submit 22 x34 civil construction plans and a completed Construction Plan Checklist directly to the Public Works Administration Department for review. Please allow 15 business days for review. The plans shall conform to the most recent construction plan checklist, standard details and general notes which are located on the City s website: http://www.cityofsouthlake.com/publicworks/engineeringdesign.asp * Submit with Civil Construction Plans a Storm Water Pollution Prevention Plan which outlines preconstruction, construction and post-construction erosion control measures. * A right of way permit shall be obtained from the Public Works Operations Department (817) 748-8082 to connect to the City s sewer, water or storm sewer system. * A Developer Agreement may be required for this development and may need to be approved by the City Council prior to any construction of public infrastructure. Construction plans for these improvements must be acceptable to Public Works prior to placing the Developer s Agreement on Attachment D ZA15-136 Page 5

the City Council agenda for consideration. * Any hazardous waste being discharged must be pretreated per Ordinance No. 836. *=Denotes informational comment. General Informational Comments ============= The following should be informational comments only ============== * Staff strongly recommends contacting Daniel Cortez in the City Manager s Office to schedule a SPIN meeting. Daniel can be contacted by phone at (817) 748-8029 or by e-mail at dcortez@ci.southlake.tx.us. A copy of the SPIN meeting schedule is attached. * Section 20.2 restricts the use of cleaners, laundries and/or Laundromats to a floor area not exceeding 2,500 square feet. Take-out restaurants and restaurants with drive-through service are prohibited in the C-1 zoning district. * Per section 43.13, standing seam metal roofs shall be constructed of a factory-treaded, nonmetallic, matte finish. * All lighting must comply with Lighting Ordinance No. 693, as amended. Attachment D ZA15-136 Page 6

Surrounding Property Owners SPO # Owner Zoning Physical Address Acreage Response 1. Thomas Decaro SF1A 2080 E Dove Road 7.565 NR 2. Pamela D Long SF1A 2117, 2150 E Dove Road 4.031 NR 3. Rickey McPherson C1 2180, 2190 E Dove Road 3.713566 NR 4. Paul Wagner SF1A 1480, 1620 N Kimball Avenue 2.758699 NR 5. Superintendent of Carroll ISD NR 6. City of Grapevine NR Responses: F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: (6) Responses Received: (0) Attachment E ZA15-136 Page 1

Reserved for Surrounding Property Owner Responses Attachment F ZA15-136 Page 1