Project Data Sheet Proposed projects that are to be reviewed by the GGNA Zoning & Planning Committee must provide the following information: Project Name: Project Address: Developer/Owner: Architect: Contact Phone Number Date: Proposed Zoning: Current Zoning: Zoning of Adjacent Area: Email Proposed Variences Dwelling Units: Type: Lot Dimensions: 77.75 ft. x ft. Lot Area: s.f. Proposed Floor Area: s.f. (new) s.f. (existing) s.f. (addition) FAR: (existing) (proposed) Building area excluded from FAR: s.f. Green space (unpaved): s.f. % of lot area Proposed MLA: Allowed MLA: Proposed Parking: spaces Zoning Required Parking: spaces Building Height Proposed: ft. Allowed: ft. At highest point: ft. Proposed front yard setback: ft. Required front yard setback: ft. Proposed side yard setback: ft. Required side yard setback: ft. Proposed rear yard setback: ft. Required rear yard setback: ft. Are there any existing buildings on site? describe: Will any (or all) be demolished? Other Remarks: i.) None, existing building is only a shell. It was completely gutted years back and it is barely standing.
A PDF file of the Project Data Sheet & requested architectural materials (listed below) for each project should be e-mailed to Community Chair ggnazapc@gmail.com at least one week before the meeting date. Nine (9) copies of the Project Data Sheet & requested architectural materials (listed below) should be brought to the meeting for the ZAPC members. a.) Small scale context footprint. This should show how the project will fit in with the surrounding properties 00 ft. on each side. Pictures of the site and adjacent properties are helpful. b.) A Site plan with setbacks (especially showing setbacks to adjacent neighboring properties), landscaping, fences, garages, parking, curb cuts and sidewalks c.) Zoning Data as shown on the Project Data Sheet d.) Measured site plan with the following: New building(s) to be shaded gray Landscaped areas to be shaded light green. Show proposed and existing trees and shrubbery on property and parkway. Streets and alleys to be labeled. Building(s) and setbacks to be clearly dimensioned. Show outline of existing building(s) to remain on property and building(s) on properties adjacent to project. If not practical, a partial outline is acceptable for adjacent properties. Clearly show dimensioned parking spaces, bike storage, trash containers/enclosures and fences. e.)floor plans with the following: Provide floor plans of each floor with overall dimensions. Label and dimension all rooms. For floors with identical layouts, just provide one plan and note the floors in drawing label. Label square footage of each unit and each floor. f.) Exterior elevations with the following: Provide exterior elevations showing doors, windows, railings and other architectural elements. Dimension all elevations with overall heights, floor to floor heights and floo r to ceiling heights. Include elevation benchmarks at each floor, roof, top of parapets or ridge and the top of any stair/elevator tower. Label major finish materials on elevations. g.) Relevant isometric renderings showing adjacent properties for context. f. Outline of development team h.) Ultimate property use and type of ownership i.) Any relevant information about the historic use and nature of any existing buildings on the property. j.) Provide product info and if possible sample of exterior finish materials with proposed color and texture for meetings.
N 238 N ROCKWELL ST ZONING DATA PROJECT ADDRESS: 238 N. ROCKWELL ST ARCHITECT: PMPC ARCHITECTS CONTACT PHONE NUMBER: 32.207.050 EMAIL: INFO@PMPCARCH.COM LOT DIMENSIONS 9.50' C- PROPOSED VARIENCES: ZONING CHANGE FROM C- TO B2-3 TO CREATE 4 DWELLING UNITS. 20.00' 77.75' ISSUE CURRENT ZONING PROPOSED ZONING ZONING DISTRICT C- B2-3 A - USE OF PROPERTY MIXED USE MIXED USE 238 N ROCKWELL ST LOT AREA 3557. 3557. MAXIMUM FLOOR AREA RATIO.20 3.0 TOTAL BUILDING AREA (SFT.) 4268.47 BUILDING HEIGHT BUILDING HEIGHT AT HIGHEST POINT FRONT YARD SETBACK SIDE YARD SETBACK REAR YARD SETBACK GREEN SPACE (UNPAVED) (SFT.) DWELLING UNITS CONSTRUCTION TYPE MIN. LOT AREA (SFT.) PARKING SPACES EXISTING BUILDINGS ON SITE? WILL ANY OR ALL BE DEMOLISHED? 0.00' 0.00' 30.00' 0952.00 47.62' 5.00' 0.00' N/A N/A 0.00 0.00 4 IIIB 300.00 889.00 0 4 YES EXISTING STRUCTURES TO BE DEMOLISHED ZONING DATA
PUBLIC ALLEY #255 #254 #259 #249 #252 #250 #257 #253 N TALMAN AVE #247 #245 PUBLIC ALLEY #246 #244 #25 #249 #247 244 N. ROCKWELL 254 N. ROCKWELL 252 N. ROCKWELL #27 PUBLIC ALLEY #238 N ROCKWELL ST #245 #24 PUBLIC ALLEY 250 N. ROCKWELL N MILWAUKEE AVE EMPTY LOT #249 CONGRESS THEATER 246 N. ROCKWELL N FRANCIS AVE 27 N. MILWAUKEE 249 N. MILWAUKEE SITE PLAN WITH SETBACKS CONTEXT FOOTPRINT
6' ALLEY 9.50' 6' ALLEY 9.50' #27 8'-0" 8'-0" GARAGE ON GRADE 20.00' 6' ALLEY 8'-0" STAIR ENCLOUSRE TO ROOF 8'-0" NEW 4 - STORY MASONRY RESIDENTIAL BUILDING FOURTH FLOOR BALCONY FOURTH FLOOR BALCONY ENTRANCE 77.75' N ROCKWELL STREET #27 FRAME GARAGE 20.00' 6' ALLEY 2 STORY FRAME BUILDING FRAME ADDITION 77.75' N ROCKWELL STREET EMPTY LOT #249 CONCRETE WALK CONCRETE CURB EMPTY LOT #249 CONCRETE WALK CONCRETE CURB N SITE PLAN 2 /6" = '-0" /6" = '-0" N SITE PLAN - EXISTING SITE PLAN
22'-2" 64'-4" 35'-0" 0'-0"?? 5'-7" 5'-0" P- 30'-0" 6'-6" '-6" 8'-6" P-2 GARAGE 630 SF DN T R 3'-0" UP DN TRASH ENCLOSURE ON GRADE T 7'-6" R P-3 P-4 T R T R DN BATHROOM REF. MECHANICAL POWDER ROOM D W LAUNDRY 5'-5" DW FOYER BEDROOM 4 SF COAT LIVING ROOM 283 SF DN UP 5'-0" DN MASTER BEDROOM 89 SF 4'-0" 8'-0" 8'-6" 8'-2" 52'-0" 74'-0" 5'-" 0'-6" W.I. 2'-" 3'-0 /2" N FIRST FLOOR PLAN /8" = '-0" MASTER BATHROOM 0'-4" 24'-3" FIRST FLOOR PLAN BENCH
22'-2" 64'-4" 35'-0" 25'-8" 30'-0" 6'-6" 5'-6" GARAGE SLAB ON GRADE ABOVE 630 SF SLAB ON GRADE ABOVE UP COMMON UTILITY EJ SP UP BATHROOM # 2 5'-" 0'-6" MECHANICAL BEDROOM #2 7 SF '-6" LAUNDRY UP D W 2'-" 3'-0 /2" FAMILY ROOM 466 SF W.I. BEDROOM # 246 SF 4'-0" BATHROOM '-8" 8'-0" 8'-6" 8'-2" N BASEMENT FLOOR PLAN /8" = '-0" 0'-4" BASEMENT FLOOR PLAN BENCH
55'-0" 8'-6" 5'-4" 2'-5" 5'-7" REF. 9 SF 8'-6" BALCONY 8'-2" FAMILY/DINING ROOM 279 SF 5'-2" UP DN '-4" BEDROOM # 20 SF W/D DW KITCHEN 379 SF MECH. '-6" POWDER ROOM BATHROOM 7'-2" 7'-2" FOYER DN UP LIVING ROOM 283 SF MASTER BEDROOM 204 SF BALCONY BALCONY 8'-0" 8'-6" 8'-2" 74'-0" BEDROOM #2 4 SF 4'-0" 5'-"? 57'-5 /4" 0'-6" W.I. 2'-" 3'-0 /2" MASTER BATHROOM 24'-3" N SECOND/THIRD FLOOR - TYPICAL - PROPOSED /8" = '-0" 0'-8" SEC./THIRD FLOOR PLANS BENCH
8'-3" 5'-3" 60'-0" 5'-4" 2'-5" 2'-7" 8'-0" REF. 7'-4" 8'-0" BALCONY PERGOLA ABOVE BALCONY FAMILY/DINING ROOM 279 SF DW KITCHEN 379 SF LIVING ROOM 229 SF PERGOLA ABOVE BALCONY UP POWDER ROOM FOYER N FOURTH FLOOR PLAN /8" = '-0" DN W/D BEDROOM # 20 SF MECHANICAL '-6" BATHROOM BEDROOM # 2 25 SF LINEN '-4" 5'-" 0'-6" 2'-" 3'-0" MASTER BEDROOM 243 SF WALK-IN 2'-6" MASTER BATHROOM '-6" PERGOLA ABOVE BALCONY 9'-4" 52'-0" 74'-0" FOURTH FLOOR PLAN BENCH
PLANTERS MECHANICAL PLANTERS PLANTERS PLANTERS ROOF PLAN /8" = '-0" ROOF PLAN
T/0 STAIR ENCLOSURE 59' - 6" T/O PARAPET 54' - 6" ROOF 50' - 6" B/O CEILING 49' - 0" FOURTH FLOOR 39' - 0" THIRD FLOOR 27' - 8" SECOND FLOOR 6' - 4" FIRST FLOOR 5' - 0" GRADE 0' - 0" EAST ELEVATION /8" = '-0" ELEVATION
T/0 STAIR ENCLOSURE 59' - 6" T/O PARAPET 54' - 6" ROOF 50' - 6" B/O CEILING 49' - 0" FOURTH FLOOR 39' - 0" THIRD FLOOR 27' - 8" SECOND FLOOR 6' - 4" FIRST FLOOR 5' - 0" GRADE 0' - 0" SOUTH WEST ELEVATION /8" = '-0" ELEVATION
T/0 STAIR ENCLOSURE 59' - 6" T/O PARAPET 54' - 6" ROOF 50' - 6" B/O CEILING 49' - 0" FOURTH FLOOR 39' - 0" THIRD FLOOR 27' - 8" SECOND FLOOR 6' - 4" FIRST FLOOR 5' - 0" GRADE 0' - 0" NORTH ELEVATION /8" = '-0" ELEVATION
T/0 STAIR ENCLOSURE 59' - 6" '-4" '-4" '-4" 0'-0" '-6" 4'-0" T/O PARAPET 54' - 6" ROOF 50' - 6" B/O CEILING 49' - 0" FOURTH FLOOR 39' - 0" THIRD FLOOR 27' - 8" SECOND FLOOR 6' - 4" FIRST FLOOR 5' - 0" GRADE 0' - 0" WEST ELEVATION /8" = '-0" ELEVATION
6" 6" 6" 6" 8" 2" 0'-0" 0'-0" 0'-0" 0'-0" STAIRS FOR ROOF ACCES ONLY 6'-8" 49'-0" BUILDING HEIGHT AS PER ZONING CODE T/0 STAIR ENCLOSURE 59' - 6" ROOF 50' - 6" B/O CEILING 49' - 0" FOURTH FLOOR 39' - 0" THIRD FLOOR 27' - 8" SECOND FLOOR 6' - 4" FIRST FLOOR 5' - 0" 0'-0" 3'-8" 6'-4" GRADE 0' - 0" 4" BASEMENT -6' - 4" SCHEMATIC SECTION /8" = '-0" SCHEMATIC SECTION
3D VIEW