Indoor climate and energy consumption in residential buildings in Estonian climatic conditions

Similar documents
Indoor climate and ventilation performance on top floors of typical old-type apartment buildings

Indoor climate of an unheated apartment and its impact on the heat consumption of adjacent apartments

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Energy variations in apartment buildings due to different shape factors and relative size of common areas

Estonian energy policy and EPBD: Deep integrated renovation with KredEx renovation grant programme

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 7 Heiselberg, Per Kvols. Publication date: 2016

Chapter III THE HOUSING STOCK

THE CURRENT RESULTS OF URB.ENERGY PROJECT IN THE TARGET AREA JUGLA (Riga)

The relationships between the extent of mould problems and physical building characteristics in high-rise apartment buildings

Energy consumption in an old residential building before and after deep energy renovation

NFPA (2012). In a high-rise building, stairwell pressurization systems typically utilize multiple fans distributed over the height of the stair, a duc

Balanced ventilation in apartment buildings

The Impact of Balconies on Wind Induced Ventilation of Singlesided Naturally Ventilated Multi-storey Apartment

Measuring Air Change Rates using the PFT Technique in Residential Buildings in Northern Portugal

Economic justification of non-commercial buildings renovation or substitutional construction

The effect of the wind speed velocity on the stack pressure in medium-rise buildings in cold region of China

Energy Efficient and Passive House Building Design Guidelines

measures of apartment buildings

A STUDY ON AN ESTIMATION METHOD OF THE EFFECTIVE OPENING AREA OF ENTRANCE DOORS AND WINTER AIRFLOW RATE INTO ATRIUM BUILDINGS

Analyzing Ventilation Effects of Different Apartment Styles by CFD

MONITORED RESULTS FROM AN INNOVATIVE SOLAR RENOVATION OF MULTI STOREY HOUSING - EU SHINE ENGELSBY, FLENSBURG

ASHRAE STANDARD 62.1 VENTILATION ANALYSIS UNIVERSITY RIDGE AT EAST STROUDSBURG UNIVERSITY EAST STROUDSBURG, PA PREPARED FOR: JAE-WEON JEONG, PH.D.

COMFORT WITH COURTYARDS IN DHAKA APARTMENTS

Published in: NSB 2014: 10th Nordic Symposium on Building Physics June 2014 Lund, Sweden

Study of the energy performance of Korean apartment buildings with alternative balcony configurations

Impacts of Maximum Allowable Building Footprint on Natural Ventilation in Apartment Building

World Renewable Energy Congress (WRECX) Editor A. Sayigh 2008 WREC. All rights reserved. 822

Maratonvägen 36. Project summary. Energy concept: To achieve a substantial reduction of the energy losses.

DEVELOPMENT OF THE DWELLING CONSTRUCTION AND REAL ESTATE MARKET DURING THE LAST DECADE

Available online at ScienceDirect. Energy Procedia 96 (2016 )

On Smoke Control by Pressurization in Stairwells and Elevator Shafts

Assessing of thermal comfort in multi-stories old and new residential buildings in China

On Smoke Control by Pressurization in Stairwells and Elevator Shafts

ANALYSIS OF RELATIONSHIP BETWEEN MARKET VALUE OF PROPERTY AND ITS DISTANCE FROM CENTER OF CAPITAL

Where rivers connect

Daylight availability in courtyards of urban dwellings in Athens

CHANGE IN VALUE ALTERATIONS MADE OCCUPANCY CHANGES

COMPARISON OF SAMPLING METHODS FOR AIR TIGHTNESS

Influence of occupants behavior on indoor CO 2 concentration of a naturally ventilated multifamily building in Porto, Portugal.

THE IMPACT OF RESIDENTIAL REAL ESTATE MARKET BY PROPERTY TAX Zhanshe Yang 1, a, Jing Shan 2,b

Following is an example of an income and expense benchmark worksheet:

Passive Cooling Measures for Multi-Unit Residential Buildings

Return on Investment Model

Journal of Babylon University/Engineering Sciences/ No.(5)/ Vol.(25): 2017

Development of e-land Administration in Sweden

GLAZED BALCONIES AND SUN SPACES ENERGY SAVERS OR ENERGY WASTERS?

Title of the measure: EST 19 Support scheme for energy efficient renovation of apartment buildings ( )

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 6 Heiselberg, Per Kvols. Publication date: 2016

INDOOR AIR QUALITY AND ENERGY EFFICIENCY IN MULTI-APARTMENT BUILDINGS BEFORE AND AFTER RENOVATION: A CASE STUDY OF TWO BUILDINGS IN RIGA

Be energy efficient in your rented property - A guide for tenants

Cadastre and Other Public Registers: Multipurpose Cadastre or Distributed Land Information System?

Cube Land integration between land use and transportation

INDOOR ENVIRONMENT IN MULTI-STOREY RESIDENTIAL BUILDINGS Thermal and Visual Comfort Using IV20 MASTER THESIS

METROPOLITAN NORTH GEORGIA WATER PLANNING DISTRICT CONSERVATION PRICING GUIDANCE JANUARY 2014

DEMAND FR HOUSING IN PROVINCE OF SINDH (PAKISTAN)

Evacuation Design Focused on Quality of Flow

To Improve Space Utilization Efficiency: Periodic Renting Strategies of Residential Open Buildings

Integrated Urban Development Concept

Is there a conspicuous consumption effect in Bucharest housing market?

RETROFIT OF BUILDINGS BY DUBLIN CITY COUNCIL. Matt Carroll, City Architects Division DUBLIN CITY COUNCIL

PROPERTY FACTS. Your Green Office In The Heart of The City

COMPARATIVE STUDY ON THE DYNAMICS OF REAL ESTATE MARKET PRICE OF APARTMENTS IN TÂRGU MUREŞ

Comparative Perspectives on Urban Housing Conditions 1

IMPACT OF REAL PROPERTY MARKET ON CHANGES OF CADASTRAL VALUE AND FORMATION OF SAMARA REGIONAL BUDGET

The effect of atrium façade design on daylighting in atrium and its adjoining spaces

Region Hovedstaden Nyt Hospital Nordsjælland

Strategic Study and Dynamics Decision for Development Program of City Housing

VACANT URBAN RESIDENTIAL LAND SURVEY 2010 UPDATE

Anemomaster

SCOTTISH GOVERNMENT RESPONSE TO PRIVATE RENTED HOUSING (SCOTLAND) BILL STAGE 1 REPORT

Evaluating Unsmoothing Procedures for Appraisal Data

ENERGY EFFICIENCY IN HOUSING SECTOR OF UKRAINE

REAL ESTATE RENOVATION DECISIONS BASED ON COST APPROACH APPRAISING PRINCIPLES Real estate renovation decisions

Estonia KredEx energy efficiency schemes

INRODUCTION STATISTIC DATE OF DWELLINGS STOCKS IN POLAND.

What Factors Determine the Volume of Home Sales in Texas?

Assessing the effect of new control and payment methods on heating energy consumption and occupant behaviour in Chinese dwellings

Thermo-renovation: Opportunities & Barriers Experience of Latvia

How to Read a Real Estate Appraisal Report

Optimal Apartment Cleaning by Harried College Students: A Game-Theoretic Analysis

INTRODUCTION OF CHARGES FOR STREET NAMING, HOUSE NUMBERING, AND CHANGING A HOUSE NAME

Study of Environmental Cognition and Life Domains of Residents of Super High-rise Condominiums

Apartment Building in Brogården, Alingsås SE

Figure 1. The chart showing how the effort and cost of the design changes are affected as the project progresses (Anon.) Simulation tools are a key co

Exposure assessment of magnetic field in dwellings with built-in transformers in Bulgaria

Wijk van Morgen, Kerkrade

DAYLIGHT SIMULATION FOR CODE COMPLIANCE: CREATING A DECISION TOOL. Krystle Stewart 1 and Michael Donn 1

Document under Separate Cover Refer to LPS State of Housing

Review of the Prices of Rents and Owner-occupied Houses in Japan

Ad-valorem and Royalty Licensing under Decreasing Returns to Scale

Retrofitting of social housing in Estonia. Marit Otsing Estonian Union of Cooperative Housing Associations

Protecting the Stair Enclosure in Tall Buildings Impacted by Stack Effect

Residential Buildings in Bulgaria

OF CHANGE IN SHEAR WALL LOCATION ON STOREY DRIFT OF MULTISTOREY BUILDING SUBJECTED TO LATERAL LOADS

Everything's Fine at home

UNIVERSITY OF MUMBAI

Indoor Air Quality in Multi-Apartment Buildings before and after Renovation

Design idea on planning skill training system of real estate development projects in colleges and universities

ELECTRICAL LOAD CHARACTERISTICS OF SUPERINSULATED MULTIFAMILY HOUSING: A CASE STUDY

Transcription:

Indoor climate and energy consumption in residential buildings in Estonian climatic conditions TEET-ANDRUS KOIV 1, HENDRIK VOLL 1, ALO MIKOLA 1, KALLE KUUSK 1, MIKK MAIVEL 1 1 Department of Environmental Engineering, Tallinn University of Technology Ehitajate tee 5, 19086 Tallinn ESTONIA teet.koiv@ttu.ee; hendrik.voll@ttu.ee Abstract:- Investigation shows that in apartment buildings with passive stack ventilation the indoor air quality (IAQ) changes greatly. In the investigated apartment building the relative humidity level in bedrooms of different apartments varied greatly, from 20 to 72% in the autumn period. In the winter period the RH maximum reduces to 55%. High relative humidity is accompanied by problems of mould and a very low relative humidity level causes an unpleasant feeling when people get up in the morning. Greatly varying was also the morning CO2 level in bedrooms of different apartments, from 1000 ppm to 4200 ppm, the latter being quite critical. Higher levels of CO2 concentrations were first of all in bedrooms with renovated windows and with doors closed. By simulation the smallest is the energy consumption in the case of supply-exhaust ventilation. The results of the simulation of indoor climate are close to the results of the data recorded. The indoor climate of residential buildings is greatly affected by the arrangement of air change which in its turn is influenced by the external climate of the country. Keywords:-IAQ, Energy conservation, Carbon dioxide, RH, Air change determination 1 Introduction The need to increase the energy efficiency of buildings, while providing satisfactory indoor environmental quality, has become a key factor in the building sector. Energy conservation and IAQ are two sides of the same coin. To successfully manage IAQ and energy, both must have the same priority throughout the life of a home. Problems of energy conservation and indoor climate in residential buildings and the importance of both of them have been dealt with by many authors, such as Ken-ichi Kimura [1], Walker [2], Koiv [3], [4], Tali [5]. The report [6] treats of the joint effect of the IAQ and the characteristic aspects accompanying them. To analyze energy consumption in residential buildings extensive use is made of simulation programs. The above mentioned authors have made the following investigations [7], [8], [9]. To determine the air change in naturally ventilated rooms with people in them several authors Koiv [3], Stravova [10] have used a change in the CO2 concentration in the air of the room. The IAQ investigations were carried out in old type panel apartment buildings in two stages: in the autumn period with an external temperature of -3 +9 C and in the winter period with an external temperature -8-20 C. The investigations referred to serious IAQ problems, first of all in bedrooms were people spend quite a lot of time in the night. CO2 levels have been recorded and compered in different cases. Simulations of the CO2 and RH levels have been made with the software IDA ICE and the results compared with the data recorded. 2 Method 2.1 The carbon dioxide concentration and air change Suppose that initial carbon dioxide concentration in the air of the room before the beginning of the human activity is C o. As the human activity starts, the carbon dioxide level begins to rise with an intensivity of m. Air change in the room is ISSN: 1790-5079 235 Issue 4, Volume 6, April 2010

relatively small. The distribution of temperature in rooms is uniform (conditions are isothermal), supply and exhaust airflows are equal. Carbon dioxide concentration in inflow air is C v and in outflow air C. Proceeding from these conditions we can write the balance equation m dτ + L C v dτ - L C dτ - V dc = 0 (1) From equation (1) m = d + C C) L dc v (2) By integration of equation (1) m + Cv C L τ = ln L (3) V m + Cv Co L where m - carbon dioxide generation in room, L - air change in room, V - volume of room or design volume, C v - carbon dioxide concentration in external air (in supply air), C - carbon dioxide concentration in room air (in exhaust air), C o - carbon dioxide concentration in the air of the room at the beginning of the human activity, τ - time. From equation (3) we can deduce the basic equation for carbon dioxide concentration C at time moment τ L m m τ V C = C + + v Cv Co e L L (4) By carbon dioxide concentration (in external air, in room air at the beginning of the human activity and in room air at time moment of τ), carbon dioxide generation rate in room and parameters of room, by formula (3 or 4) it is possible to determine air change in a room. 3 Results 3.1 Air change and indoor climate determination Parameters of indoor climate in bedrooms of renovated apartment buildings are another essential topic of investigation. A lot of attention is sometimes paid to energy saving in renovating the apartment buildings, but the importance of indoor climate is not considered sufficiently. Investigations have shown that from the point of view of indoor climate one of the rooms that cause IAQ problems is the bedroom, in which by the waking-up time the CO2 concentration reaches its maximum value. It often happens that in residential buildings renovated are the envelope elements and the heating system, but the ventilation has been left as it was. The object of the investigation was a 72-apartment typical 9-storey apartment building, built with prefabricated concrete elements in which 45% of windows had been changed. The end walls had been insulated up to U-value 0.3 W/(m 2 K). The building has natural passive stack ventilation with vertical channels. The heating system had been renovated and provided with the heat consumption measuring system on the level of heatig coils. For dataloggering RH, indoor air temperature and CO2 data Hobo loggers U012-013 were used and for measuring the CO2 levels Carbon Dioxide Monitor Telaire 7001 were used. The IAQ investigations were carried in 16% of the apartments. Air change in bedrooms of different apartments was calculated by the measured CO2 concentration data in them by equation (3). 3.2 IAQ investigation in the autumn period The results of the calculation on air flow rates in the autumn period (column 2) investigated bedrooms are presented in Table 1. For the check up of the results the air flow rates in apartments were measured with SwemaFlow. In addition to air change data in Table 1 the maximum CO2 levels are presented. Table 1 shows that in the bedrooms of different flats the difference in air change is very great, varying from 0.3 to 6.4 L/s per person. It should be pointed out that in apartments with unrenovated windows the air change is considerably better than in bedrooms with new windows. Results of recording CO2 concentrations, RH and indoor temperature in the bedrooms of the apartments with unrenovated windows are presented in Figs. 1, 2 and 3. ISSN: 1790-5079 236 Issue 4, Volume 6, April 2010

Table 1. Results of determining air change and the maximum CO2 concentration in bedrooms of the 9-storey apartment building at night-time in the autumn period Apartment Air change, L/s per person Maximum level of CO 2 concentration, ppm 1 1.2 3698 8* 0.6 1967 21 2.1 2724 25 1.9 1963 31* 1.2 2557 36 1.7 2325 54 0.4 2364 58 0.3 3999 69 1.0 3278 71 2.0 2761 72* 6.4 1104 *Windows unrenovated In apartments 8 and 72 the RH exceeded by about 5% the allowed maximum level 45% for the cold period, which is not dangerous from the point of view of a rise in mould. Fig.2 Changes in the relative humidity in bedrooms with old windows. Figs. 4, 5 and 6 present the results of recording the CO2, RH and indoor air temperature in bedrooms of apartments with renovated windows. In Fig. 4 we can see that in all the bedrooms investigated the morning CO2 level exceeded the permitted level 1500 ppm [11], maximally amounting to 4200 ppm. Fig.5 shows that in bedrooms with renovated windows the relative humidity level exceeds the maximum value, 45% the standard [11] allows for the cold period and amounts to a highly critical level 72%. Fig.1 Nightly change of the CO2 concentration in bedrooms with old windows From Fig.1 we can see that in bedrooms with old windows the CO2 level is below 1500 ppm and in one of them about 1000 ppm. Consequently the air change is on a good (apart 72) or more or less acceptable level. In those bedrooms the CO2 level does not exceed the maximum level 1500 ppm allowed by the Indoor Climate standard [11]. Figs. 2 and 3 presents changes in RH and indoor air temperature in bedrooms with old windows. Fig.3 Indoor temperature in bedrooms with old windows ISSN: 1790-5079 237 Issue 4, Volume 6, April 2010

Fig.7 shows the cumulative distribution of the CO2 concentration in the bedrooms of apartments investigatrd in the autumn period. Fig.4 Nightly change of the CO2 concentration in bedrooms with new windows Fig.7 The cumulative distribution of the CO2 concentration in the bedrooms in the autumn period Fig.5 Nightly relative humidity level in bedrooms with renovated windows In the conditions of such a high RH the rise of mould is practically inevitable. Fig.6 Indoor temperature in bedrooms with renovated windows Figs. 3 and 6 show that the indoor temperature in the bedrooms investigated varied from 20 to 22 C, which is acceptable. Of the apartments investigated only 2 apartments (35 and 72) corresponded to the maximum permitted CO2 level 1500 ppm (level C). Only apartment 72 corresponded to the permitted level 1250 ppm (level B). There was no apartments corresponding to level A (1000 ppm). In the autumn period the CO2 concentration remained below 1500 ppm 56%, below 1250 ppm 38% and below 1000 ppm 23% of the time of the measuring period. The formation of the indoor climate in bedrooms at night-time is greatly affected by the position of the bedroom door, whether it is open or closed. Fig. 8 shows the comparison of the changes in the CO2 concentration in 1-person bedrooms in the case of open or closed doors. Fig.8 shows that in apartments (69 and 72) in bedrooms with an open door the CO2 level does not practically change during the night remaining below 1000 and 1500 ppm respectively, because of the interfusion of the CO2 with the air of the neighbouring rooms. But in bedrooms with closed doors the CO2 concentration rises considerably reaching 2200 ppm in apartment 39 and 3000 ppm in apartment 1. ISSN: 1790-5079 238 Issue 4, Volume 6, April 2010

Fig.9 presents the comparison of the air change in the winter and the autumn periods. The figure shows that in the winter conditions the air change is better which is natural in the conditions of the passive stack ventilation. An exeption is apartment 25 where the situation is the reverse owing to the fact that the windows are tightened and the ventilation grills are partly closed in the conditions of low external temperatures. Fig.8 Comparison of the changes in the CO2 concentration in 1-person bedrooms in the case of open or closed doors: in apartments 1 and 39 the doors are closed, in apartments 72 and 69 - open 3.2 IAQ investigations in the winter period In the winter period investigation were carried out at low external air temperatures from -8 to -20 C. Due to that the passive stack ventilation functioned more effectively. However old windows were tightened and ventilation grills were partly cosed. Table 2 presents the air change determined on the bases of the measured CO2 values and the maximum CO2 concentration in different apartments. Fig. 9 Comparison of the air change in the winter and the autumn periods in different apartments Results of recording CO2 concentrations in the bedrooms of the apartments with unrenovated windows in the winter period are presented in Figs. 10, and 11. Table 2. Air change values per person and the maximum CO2 concentration values in bedrooms Apartment Air change rate, l/s per person Maximum concentration of CO 2, ppm 1 1.3 2642 8* 1.1 1244 17* 0.8 2946 23 3.6 3242 25 1.5 1845 33 1.5 3216 39 2.2 2460 54 0.4 3293 58 0.5 2825 71 2.7 2224 72* 7.0 1337 Fig.10 Nightly change of the CO2 concentration in bedrooms with old windows ISSN: 1790-5079 239 Issue 4, Volume 6, April 2010

41% and below 1000 ppm 24% of the time of the measuring period. Figs. 13 and 14 present changes in RH in bedrooms with old and new windows in the winter period. Fig.11 Nightly change of the CO2 concentration in bedrooms with new windows From Figs 10 and 11 we can see that in the winter period in bedrooms both with old and new windows the IAQ is considerably better than in the autumn period. But in some bedrooms the CO2 concentration at night exceeds 1500 ppm and reaches up to 2500 ppm. Fig.13 Nightly relative humidity level in bedrooms with old windows Fig.12 shows the cumulative distribution of the CO2 concentration in all the bedrooms of apartments investigated during the autumn period. Fig.14 Nightly relative humidity level in bedrooms with renovated windows Fig.12 Cumulative distribution of the CO2 concentration in the bedrooms of apartments investigatrd in the winter period In the winter period of the apartments investigated only 2 apartments (35 and 72) corresponded to the maximum permitted CO2 level 1500 ppm (level C). Only apartment 72 corresponded to the permitted level 1250 ppm (level B). There was no apartments corresponding to level A (1000 ppm). In the winter period the CO2 concentration remained below 1500 ppm 59%, below 1250 ppm Owing to a decrease in the moisture content of the external air and an increase in air change (due to the stack effect) the RH in the majority of the apartments remains within the limits of 25-45% foreseen by the standard [11], amounting to 50% in 2 apartments and remaining below 25% in one apartment, but does not fall below the critical 20%. Figs. 15 and 16 shows the comparison of the changes in the CO2 concentration and RH in 1- person bedrooms in the case of open or closed doors. ISSN: 1790-5079 240 Issue 4, Volume 6, April 2010

Fig. 15 Comparison of the changes in the CO2 concentration in 2-person bedrooms in the case of open or closed doors: in apartments 39 and 17 doors closed, in 8 and 25 open In Fig. 15 we can see that in bedrooms with closed doors the nightly CO2 concentration considerably rises in the conditions of passive stack ventilation. Fig.17 Indoor temperature in bedrooms with old windows In the winter conditions the indoor temperatures are lower than those of the autumn period. In several apartments the temperature was below 19 C and fell even to 16 C. The low 16-17 C temperatures in the winter conditions are caused by the wish of people with low income to economise on the heating expenses. Unfortunately that saving was amplified by the distribution of the heating expenses applied: the permanent cost 30% and the varying cost 70% (i.e the cost for the heat consumed) in the conditions of measuring the heating expenses by the heating coils. Fig.16 Comparison of the differences in the level of RH in 2-person bedrooms in the case of open or closed doors: in apartments 39 and 17 the doors are closed, in apartments 8 and 25 open In Fig. 16 we can see that changes in the RH level are small in bedrooms with both closed and open doors. Fig.17 and 18 present changes in indoor temperature in bedrooms with both old and new windows. Fig.18 Indoor temperature in bedrooms with new windows It should be pointed out that an investigation of energy consumption, carried out by TUT in 2009 by dynamic simulation showed that in old panel apartment buildings even switching off the heating in a apartment decreases the heating expenses of the whole apartment building relatively little: depending on the location of the apartment ISSN: 1790-5079 241 Issue 4, Volume 6, April 2010

15-30% [13]. This is due to an extensive heat trancfer between the unheated apartment and the neighbouring apartments. At the same time the temperature in the apartment decreased maximally by 3-4 C. Thus the distribution of the heating expenses applied is wrong and should be at least the reverse: i.e. the permanent expenses 70-75% and the varying expenses 30-25% or even less, because no heating expenses for the common rooms are taken into account in the case of heat measuring in heating coils. The smallest is the energy consumption in the case of supply-exhaust ventilation with heat recovery unit. Figs. 19, 20 and 21 present the results of the simulation of the CO2 concentration and the comparison of them with the results measured in different apartments. Such a wrong distribution of heating expenses causes social tension between the inhabitants and contributes to the low quality of the indoor climate in apartments, because a number of apartments decrease the air change to deminish the heating expenses. 3.3 Simulations of energy consumption and indoor climate Analysis of energy consumption and the CO2 concentation simulations was made by the simulation program IDA ICE on the basis of recorded data. Energy consumption in an apartment building with different ventilation systems is presented in Table 3. It can be seen that in the case of passive stack ventilation the energy consumption for air change is about 2 time smaller than by using mechanical exhaust ventilation. Fig.19 Comparison of the changes in the CO2 concentration in 1-person bedroom in the case of simulation and measurements in the winter period (apartment 1) It must be pointed out that the results of the simulation are very close to the results of the measurements in partments 1 and 17. In apartment 21 the nightly maximum CO2 concentration by simulation is higher than the results measured. Table 3. Energy consumption in an apartment building with different ventilation systems Natural ventilation, air change n=0.2 651 Mechanical exhaust ventilation, air change n=0,5 774 Supply-exhaust ventilation with heat recovery unit, air change n=0.5 622 Energy consumption for heating and air change MWh/a Fig.20 Comparison of the changes in the CO2 concentration in a 2-person bedroom in the case of simulation with the results measured in the winter period (apartment 17) ISSN: 1790-5079 242 Issue 4, Volume 6, April 2010

Fig.21 Comparison of the changes in the CO2 concentration in 2-person bedroom in the case of simulation with the results measured in the winter period (apartment 21) Fig.23 Comparison of the changes in the RH level in a 2-person bedroom in the case of simulation with the results measured in the winter period (apartment 25, the door is open) Figs. 22, 23 and 24 present the results of the simulation of the RH level in bedrooms and the comparison of them with the results measured in different apartments. Fig.22 Comparison of the changes in the RH level in a 2-person bedroom in the case of simulation with the results measured in the winter period (apartment 1, the door is open) Fig.24 Comparison of the changes in the RH level in a 1-person bedroom in the case of simulation with the results measured in the winter period (apartment 71, old windows) From Fig. 22, 23 and 24 we can see that if we know the nunber of the people, the profile of their presence and the data on air change, it is relatively easy to determine the RH levels of the rooms by simulation. 4 Conclusions The investigation shows that in apartment buildings with passive stack ventilation the IAQ changes greatly. In the autumn period the level of indoor temperature 20 22 C can be considered quite ISSN: 1790-5079 243 Issue 4, Volume 6, April 2010

normal, but the relative humidity level in bedrooms of different apartments varied greatly from 35 to 72%. It must be remarked that high relative humidity is accompanied by problems of mould. Greatly varying was also the morning CO2 level in bedrooms of different apartments, from 1000 ppm to 4200 ppm, which is quite critical. Higher levels of CO2 concentrations were first of all in bedrooms with renovated windows. In winter conditions due to higher intensivity of the passive stack ventilation the CO2 concentration in bedrooms is somewhat lower, yet at night-time it reaches 2500 ppm and during all the period of measuring 3200 ppm. In the winter period no exessive RH level was observed, but in some apartments the RH level was below 25% which is too low. Low temperatures (in some apartments even 16 C) in the winter conditions are caused by the wish of people with low income to economise on heating expenses. This is contributed to by the incorrect sharing of the varying heating expenses in the case of measuring heat by heating coils. In the apartments of people with low income causes a considerable deterioration of the IAQ because people close the openings of the inflow of external air. Such a wrong distribution of heating expenses causes social tension between the inhabitants owing to great differences in heating expenses. By simulation the smallest is the energy consumption in the case of supply-exhaust ventilation with heat recovery. It should be pointed out that the results of the simulation of indoor climate (CO2 concentration and RH level) are relatively close to the results of the measurements. It should be pointed out that indoor climate of residential buildings with passive stack ventilation is greatly affected by the arrangement of air change which is influenced by the external climate of the country. References: [1] Ken-ichi Kimura. Relationship between energy conservation in buildings and indoor air quality. Indoor air quality, 2003. [2] A.Walker. Natural Ventilation. National Renewable Energy Laboratory, March, 2008. http://www.wbdg.org/resources/naturalventilati on.php. [3] T.-A.Koiv. Indoor climate and ventilation in Tallinn school buildings. Proc. Estonian Acad. Sci. Eng., 2007, 13, 1, 17-25. [4] T.-A.Koiv, H.Voll, M.Rebane. Indoor climate in education and residential buildings. The International Conference in Sustainable Development in Building and Environment. Chongqing 28 30 October, China, 2009, 2. [5] T.-A.Kõiv. (2008). Indoor climate and ventilation performance on top floors of typical old-type apartment buildings. Estonian Journal of Engineering, 14, 17 28. [6] M.Tali. Indoor climate and energy consumption in panel apartment buildings. Masters theses, TUT, 2009, Estonia. [7] Energy Conservation and Indoor Air Quality: Benefits of Achieving Both in Homes, January 2009. http://www.aerias.org/uploads/iaq%20energy %20Homes%20FINAL.pdf [8] M. Maivel, K. Kuusk. Energy consumption and indoor climate analysis in detached houses. 2nd WSEAS International Conference on Urban Rehabilitation and Sustainability, Morgan State University, Baltimore MD, USA, November 7-9, 2009, WSEAS, 2009, [9] T. A. Kõiv, A. Hani, T. Kalamees. Määruse Energiatõhususe miinimumnõuded täiendav analüüs, TUT, 2010, 118p. [10] Stavova, P., Melikov, A.K., Sundell, J. A new approach for ventilation measurement in homes based on CO 2 produced by people. 17 th Air Conditioning and Ventilation Conference 2006, May 17-19, 2006, Prague, pp291-296. [11] EVS 839. 2003. Indoor climate. Estonian Centre for Standardisation. [1 [12] EN-15251. 2007. Indoor environmental input parameters for design and assessment of energy performance of buildings- addressing indoor air quality, thermal environment, lighting and acoustics. CEN. [13] E.Seinre. Energy consumption analysis of an apartment building with BSIM simulation software. Masters theses, TUT, Tallinn, 2009. [14] K. Kuusk. Energy consumption and indoor climate simulation of apartment buildings. Masters theses, TUT, 2009, Estonia. ISSN: 1790-5079 244 Issue 4, Volume 6, April 2010