PROVIDENCE (BOLLARD BULRUSH SOUTH) LOCAL DEVELOPMENT PLAN. 2263Rep146E

Similar documents
Requirements for accepted development and assessment benchmarks for assessable development

Multi-unit residential uses code

PRELIMINARY PROVISIONS TEXT OF RESTRICTIONS

Small Lot Housing Code (June 2013):

Re: Justification to support the creation of two survey-strata lots at Lot 156 (#44) High Street, Sorrento.

9.3.6 Dwelling house code

Small Lot Housing Code

9.3.5 Dual occupancy code

Annexure A - Retaining Walls, Fences and Site Works

Part 9 Specific Land Uses - Dual Occupancy

H6 Residential Terrace Housing and Apartment Buildings Zone

H5. Residential Mixed Housing Urban Zone

MEMORANDUM OF COMMON PROVISIONS Section 91A Transfer of Land Act 1958 Victorian Land Titles Office

8.5.1 R1, Single Detached Residential District

H4. Residential Mixed Housing Suburban Zone

Part 9 Specific Land Uses - Multi Dwelling Housing

Accessory Coach House

SCHEDULE 32 TO CLAUSE DESIGN AND DEVELOPMENT OVERLAY

RURAL SETTLEMENT ZONE - RULES

CASTLES OF CALEDON URBAN DESIGN REPORT

Summary of Greenfield Housing Code Development Standards

8.14 Single Detached with Granny Flat or Coach House Edgemere

Appendix C Built Form Guidelines

SCHEDULE 31 TO CLAUSE DESIGN AND DEVELOPMENT OVERLAY

H5. Residential Mixed Housing Urban Zone

900 BURRARD STREET CD-1 GUIDELINES (BY-LAW NO. 6421) (CD-1 NO. 229) CONTENTS. 1 Application and Intent... 1

SCHEDULE 8 TO THE DESIGN AND DEVELOPMENT OVERLAY RESIDENTIAL AREAS SURROUNDING ACTIVITY CENTRES AND ALONG MAIN ROADS

Composition of traditional residential corridors.

Dwelling house guide

BYLAW NO. 15/026 A BYLAW OF THE REGIONAL MUNICIPALITY OF WOOD BUFFALO TO AMEND THE LAND USE BYLAW NO. 99/059

Attention: Andrew Fowler-Tutt (Manager Approval Services)

H4. Residential Mixed Housing Suburban Zone

RESIDENTIAL DESIGN GUIDELINES

Part 4.0 DEVELOPMENT REGULATIONS

PORT PHILLIP PLANNING SCHEME. Condition

Advisory Design Panel Report For the Meeting of February 27, 2019

State Administrative Tribunal Reconsideration. Responsible Authority Report (Regulation 12)

LITTLE MOUNTAIN ADJACENT AREA REZONING POLICY

RM-7, RM-7N and RM-7AN Districts Schedules

RT-11 and RT-11N Districts Schedules

Queensland Housing Code

Urban Design Brief (Richmond) Corp. 1631, 1635, 1639, 1643 and 1649 Richmond Street City of London

Plan Dutch Village Road

RT-5 and RT-5N Districts Schedule

DRAFT FOR DISCUSSION PURPOSES ONLY. Port Credit Local Area Plan Built Form Guidelines and Standards DRAFT For Discussion Purposes

C-5, C-5A and C-6 Districts Schedule

There is no Communal Open Space (COS) requirement for condominium developments.

Objectives The objectives are as listed in the relevant underlying zones and Auckland wide provisions, except as specified below:

DESIGN, ACCESS & PLANNING STATEMENT

EDITION 1. This is a SPEAR plan. EASEMENT INFORMATION. Origin E-1 DRAINAGE SEE DIAG PS Y/S1 WHITTLESEA CITY COUNCIL

Division 8 General Urban (T4) Zone: Assessment Criteria and Assessment Tables

Council Name: The requirement has been satisfied. The requirement is to be satisfied in Stage. Council delegate Council seal.

RM-8 and RM-8N Districts Schedule

CD-1 (264) 101 Terminal Avenue By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

Update on the Avenues and Mid-Rise Buildings Action Plan

P. H. Robinson Consulting Urban Planning, Consulting and Project Management

Urban Design Brief Dundas Street. London Affordable Housing Foundation. November Zelinka Priamo Ltd.

PS X PLAN OF SUBDIVISION EDITION 1 LOCATION OF LAND. Notations VESTING OF ROADS AND/OR RESERVES NOTATIONS EASEMENT INFORMATION SV00

SCHEDULE [NUMBER]31 TO CLAUSE DESIGN AND DEVELOPMENT OVERLAY

Ontario Municipal Board Order issued October 22, 2014 in Board File No. PL CITY OF TORONTO. BY-LAW No (OMB)

LeBreton Flats Redevelopment Development Summary Chart (First Subdivision)

4 DEVELOPMENT STANDARDS FOR

Report of: DEVELOPMENT MANAGEMENT SECTION HEAD. 19 Cassiobury Park Avenue PARK

DEVELOPMENT AREA = 3.65ha. T F LOTS & S36-S38

Division 5 Residential Low Density Zone: Assessment Criteria and Assessment Tables

Part Five: Commercial Districts and Regulations

I Harris. Melbourne. John Quirk, Member. Merits Review of Refusal

Section 6 Residential (R3) Zone

Chapter DOWNTOWN ZONING DISTRICTS

RM-11 and RM-11N Districts Schedule

Ku-ring-gai Local Environmental Plan No 194

SPECIALIZED COMMERCIAL RESIDENTIAL (CR) ZONES

Seminar: Subdivision Design. Bushfire Management Overlay. Focus on applying defendable space. March 2013

Revised Development Control Policy Residential Subdivision

ARTICLE 5. R-6 Residential- Duplex, Single Family Detached and Townhouse District

Amendment GC81 Expert Urban Design Evidence Wirraway. MARK SHEPPARD 9 May 2018

RT-3 District Schedule

34.02 COMMERCIAL 2 ZONE

Director, Community Planning, Toronto and East York District

RT-6 District Schedule

ARTICLE 3: RESIDENTIAL DISTRICTS

Appendix1,Page1. Urban Design Guidelines. Back to Back and Stacked Townhouses. DRAFT September 2017

BYLAW NUMBER 64D2010

International Village By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

PART 4 - GENERAL PROVISIONS AND PROCEDURES

APPENDIX E PAGE 1 of 25 NOTE: ITALICS INDICATE ADDITIONS OR ALTERATIONS RM-9, RM-9A, RM-9N AND RM-9AN GUIDELINES DRAFT

STAGE 7 ANNEXURE C DEED OF RESTRICTIVE COVENANT

ACCESSORY DWELLING UNITS IN THE SOUTHEAST SECTOR

CITY OF TORONTO. BY-LAW No

PART 11 TWO-FAMILY RESIDENTIAL ZONES

3.1 Existing Built Form

City of Reno October 30, 2012 Draft Midtown Zoning Text Amendments 1

RM 4 and RM 4N Districts Schedule

SCHEDULE 1[PPPS] 4[MPS] TO CLAUSE CAPITAL CITY ZONE

RM-1 and RM-1N Districts Schedule

LOCATION: LUC AND UNDERLYING ZONING: OCP DESIGNATION:

25 Leonard Avenue - Official Plan Amendment and Zoning Amendment Applications - Preliminary Report

Simon Court 2-4 Neeld Crescent London NW4 3RR

Toronto and East York Community Council Item TE33.3, as adopted by City of Toronto Council on June 26, 27 and 28, 2018 CITY OF TORONTO BY-LAW -2018

Annexure C. Baldivis Parks Stage 2 Restrictive Covenants

Transcription:

1

PROVIDENCE (BOLLARD BULRUSH SOUTH) Prepared by: PO Box 796 Subiaco WA 6904 t: 9382 1233 f: 9382 1127 www.cleplan.com.au October 2013 This Local Development Plan has been approved by Council under the provisions of The City of Kwinana Town Planning Scheme No. 2 and the Wellard Residential Local Structure Plan....... Principal Planner Date City of Kwinana

TABLE OF CONTENTS i ii Preamble Operation of the Local Development Plan PLAN A - 1.0 PART ONE STANDARD PROVISIONS 1.1 Provisions applicable to Laneway Access Lots 1.2 Provisions applicable to lots with no lane access and frontage less than or equal to 13 metres 1.3 Provisions applicable to lots with no lane access and frontage greater than 13 metres 1.4 Provisions applicable to lots coded R20 1.5 Provisions applicable to R50 Density Sites 1.6 Provisions applicable to four-pack lots 2.0 PART TWO ADDITIONAL PROVISIONS 2.1 Provisions applicable to lots in bush fire prone areas 2.2 Provisions applicable to lots subject to quiet house design 3

www.cleplan.com.au LEGEND Public Open Residential R20 (refer section 1.4) Residential (>13m frontage) (refer section 1.3) Residential (= <13m frontage) (refer section 1.2) Laneway lots (refer section 1.1) R50 Density Sites (refer section 1.5) 4-Packs (R30) (refer section 1.6) Restricted vehicular access 6 metre minimum setback Garage Access Easement 1 metre minimum garage setback Mandatory garage nil setback Designated garage location Lots subject to quiet house design - as identified in approved Local Structure Plan (refer section 2.2) Public Open Lots subject to AS3959 (Bush Fire Construction Standards) - as identified in approved Local Structure Plan (refer section 2.1) Public Open Public Open Public Open Lots subject to laneway surveillance requirements (refer section 1.1) This plan is provided for information purposes only and does not form part of this LDP. The subdivision layout is as per WAPC approval 146744, and is subject to change at the discretion of the developer and WAPC. Minor changes to the subdivision layout does not warrant an amendment to this LDP. ROAD Bush Forever 2263-147C-01 (30.07.2013), not to scale CONTEXT PLAN Providence (Bollard Bulrush South)

I) PREAMBLE This Local Development Plan (LDP) is prepared pursuant to the Detailed Area Plan provisions of Clause 6.17 of the City of Kwinana Town Planning Scheme 2, and condition 19 of WAPC subdivision approval 146744 dated 18 January 2013. Unless otherwise stated in this LDP, all development shall be in accordance with the City s Scheme, the Residential Design Codes of WA, and the Wellard Residential (Bollard Bulrush South) Local Structure Plan. The requirement to consult with adjoining or other landowners to vary the Residential Design Codes in accordance with the Local Development Plan (LDP) is not required except where variations to the provisions of the LDP are sought. Planning Approval is not required, but a Building Permit is required, for the construction of a dwelling on any lot within the area covered by the LDP (including lots with a land area less than 260 square metres) except where varitions to the provisions of the LDP are sought. II) OPERATION OF THE This Local Development Plan is separated into two Parts. 1. The Part One standards represent additional requirements and variations to the Residential Design Codes in order to facilitate better design outcomes, greater land use efficiencies, and to ensure appropriate residential streetscapes. These standards constitute Deemed-to-Comply requirements pursuant to the Codes. These controls apply to: all R50 coded laneway lots; all R30 and R50 coded lots with frontage less than or equal to 13 metres; all R30 and R50 coded lots with frontage greater than 13 metres; all R20 coded lots; all R50 coded density sites; and all R30 coded Four-Pack lots. The Context Plan shows the various lot types, as per approved subdivision 146744. The Context Plan is provided for information purposes only, and does not form part of this LDP. 2. Part Two responds directly to the requirements of the approved Local Structure Plan and condition 19 of WAPC approval 146744, and introduces additional development control provisions for: a) Lots that are deemed to be in bushfire prone areas (as per the Bush Fire Management Plan endorsed as a detail of the Local Structure Plan); and b) Lots that are deemed to be affected by freeway noise (as per the Acoustic Assessment endorsed as a detail of the Local Structure Plan). Where the criteria outlined in Part One of this LDP cannot be satisfied, the planning application shall be assessed in accordance with the applicable Performance Criteria of the Residential Design Codes. 5

www.cleplan.com.au Visually permeable fencing. POS Dwelling setback minimum 2m from POS boundary. Dwelling setback from primary street a minimum of 2m, with verandah and front facade treatments to 1.5m. POS Boundary walls permitted on both side boundaries. Height and length restrictions apply. Dwelling setback 1m from side boundary where abutting POS. Maximum 70% site cover subject to the provision of a 20m² minimum outdoor living area with minimum dimension of 4m x 4m. GARAGE GARAGE GARAGE LANE LANE Garages to be setback a minimum of 0.5m and maximum of 1.5m from laneway. 2263-150-01 (15.08.2013), not to scale SETBACK REQUIREMENTS FOR LANEWAY ACCESS LOTS Providence (Bollard Bulrush South)

PART ONE STANDARD PROVISIONS 1.1 Provisions applicable to Laneway Access Lots The following provisions constitute Deemed-to-Comply provisions pursuant to the Codes and development standards under the City of Kwinana Town Planning Scheme No. 2 for all laneway lots. All other Deemed-to- Comply provisions of the R-Codes and Local Structure Plan apply. TABLE 1.1 Public Open Interface (applicable where lots adjoin POS) RELEVANT R-CODE CLAUSE Additional Requirement 5.2.4 5.1.3 5.1.2 Setbacks 5.1.2 C2.1 - C2.4 Boundary Walls 5.1.3 C3.2 Private Open Ancillary Dwellings Surveillance of H laneways Building Design Utilities and Facilities 5.1.4 C4 & 5.3.1 C1.1 5.5.1 C1 5.2.3 C3.2 Additional Requirement 5.4.5 ACCEPTABLE DEVELOPMENT PROVISIONS VARIATION / ADDITIONAL REQUIREMENT All dwellings shall have a minimum of one habitable room with a major opening facing toward the public open space. All lots shall have visually permeable fencing to the public open space boundary. Boundary walls are not permitted abutting a public open space boundary. Buildings on public open space lots shall be setback a minimum of 2m from the public open space boundary, except for side boundaries abutting Public Open where the setback is 1m. All clothes drying areas, hot water systems and sheds shall not be located between the dwelling and the public open space boundary, except where screened from view or integrated into the dwelling design. Buildings shall be setback from the primary street as follows: Minimum Setback 2m dwelling and 1.5m for verandah or front facade treatment. Maximum Setback 4m Note: the front setback averaging provision of the R-Codes does not apply. Buildings shall be setback a minimum of 1 metre from the secondary street. Garages are to be setback a minimum of 0.5m and a maximum of 1.5m from the laneway boundary. Boundary walls up to both side boundaries where located behind the minimum front setback, within the following limits: Single Storey Two Storey & Above Maximum height - 3.5m - Maximum height 6.5m Maximum length No limit - Maximum length Up to 12m in length Garages on laneway lots are permitted to have a nil setback to either side boundary in addition to the boundary wall of dwelling, excluding a secondary street boundary (subject to compliance with vehicular access restrictions). Minimum open space of 30% (site cover 70%) subject to the provision of an Outdoor Living Area with: a) A minimum useable space of 20m², minimum dimension of 4m and in accordance with the R-Codes; and b) Located adjoining the northernmost or easternmost side boundary. Ancillary Dwellings do not require an additional car parking bay on site. An Ancillary Dwelling is permitted on all laneway lots, including those less than 450m². Where indicated on the LDP Plan by the symbol O, dwellings shall provide one or more of the following: An Ancillary Dwelling, or habitable space located above the garage, with adequate window(s) that overlook the central leg of the H laneway; A second storey window to a habitable room within the dwelling that can overlook the laneway; or Visually permeable fencing for a portion of the boundary adjacent to the laneway, allowing for surveillance of the laneway from a habitable room. Dwellings shall provide the following: A principle pedestrian access (front door) that faces the primary street and is a dominant feature of the facade; and At least one of the following architectural features: gable/gablet portico (recessed or projecting) verandah with minimum depth of 1.5m feature wall All dwellings shall include a store room with a minimum area of 4m² constructed under the main roof of the dwelling or garage, accessible from the exterior of the dwelling or from within the garage in accordance with the R-Codes. Storage area shall have a minimum dimension of 1m where incorporated into a garage, and 1.5m dimension elsehwere. Solar Access for Adjoining Sites 5.4.2 C2.1 Overshadowing provisions of the R-Codes do not apply. 7

www.cleplan.com.au Garage setback minimum 3m from primary street. Dwelling setback minimum 2m from primary street. STREET GARAGE GARAGE Boundary walls on both sides for lots 10m or less. Note: length restrictions apply. Side boundary setback as per R-Codes. Rear boundary setback as per R-Codes. 2263-150-02 (15.08.2013), not to scale SETBACK REQUIREMENTS FOR LOTS WITH NO LANE ACCESS AND FRONTAGE LESS THAN OR EQUAL TO 13 METRES Providence (Bollard Bulrush South)

1.2 Provisions applicable to lots with no lane access and frontage less than or equal to 13 metres (R30 & R50) The following provisions constitute Deemed-to-Comply provisions pursuant to the Codes and development standards under the City of Kwinana Town Planning Scheme No. 2 for all lots with no lane access, and frontage less than or equal to 13m. All other Deemed-to-Comply provisions of the R-Codes and Local Structure Plan apply. TABLE 1.2 RELEVANT R-CODE CLAUSE Setbacks 5.1.2 C2.1 - C2.4 Building Design Boundary Walls Private Open Additional Requirement 5.1.3 C3.2 5.1.4 C4 & 5.3.1 C1.1 Buildings setback from the primary street as follows: ACCEPTABLE DEVELOPMENT PROVISIONS VARIATION / ADDITIONAL REQUIREMENT Minimum Setback 2m. Note: the front setback averaging provision of the R-Codes does not apply. Buildings to be setback minimum of 1m from the secondary street. Garages may be setback to a minimum of 3.5m, provided the garage is not forward of the dwelling alignment. Garages may be aligned with the dwelling provided they do not exceed 3m setback line. Where garages exceed 50% of the lot frontage they shall be setback at least 1m behind the dwelling alignment. Dwellings shall provide the following: A principle pedestrian access (front door) that faces the primary street and is a dominant feature of the facade; and At least one of the following architectural features: gable/gablet portico (recessed or projecting) verandah with minimum depth of 1.5m feature wall Boundary walls to the dwelling shall be located on one side boundary to maxmise solar passive design, and located behind the maximum front setback, within the following limits: Single Storey Two Storey Maximum height - 3.5m Maximum height - 6m Maximum length - No limit Maximum length - 12m For lots with a frontage of 10m or less, nil setbacks are permitted to both side boundaries for a maximum of 9m on each side. Minimum open space of 30% (site cover 70%) subject to the provision of an Outdoor Living Area with: a) A minimum useable space of 30m², minimum dimension of 4m in accordance with the R-Codes; and b) Located adjoining the northernmost or easternmost side boundary. Utilities and Facilities Solar Access for Adjoining Sites 5.4.5 All dwellings shall include a store room with a minimum area of 4m² and a minimum dimension of 1.5m constructed under the main roof of the dwelling or garage, accessible from the exterior of the dwelling or from within the garage in accordance with the R-Codes. Storage area shall have a minimum dimension of 1m where incorporated into a garage, and 1.5m dimension elsewhere. 5.4.2 C2.1 Overshadowing provisions of the R-Codes do not apply. 9

www.cleplan.com.au Dwelling setback minimum 2m from primary street. Garage setback minimum 3m from primary street. STREET Secondary street setback as per R-Codes. GARAGE GARAGE GARAGE STREET Side boundary setback as per R-Codes. GARAGE Boundary wall to one side boundary as per R-Codes. Boundary walls permitted to both side boundaries for lots less than 350m². Note: length restrictions apply. 2263-150-03 (15.08.2013), not to scale SETBACK REQUIREMENTS FOR LOTS WITH NO LANE ACCESS AND FRONTAGE GREATER THAN 13 METRES Providence (Bollard Bulrush South)

1.3 Provisions applicable to lots with no lane access and frontage greater than 13 metres (R30 & R50) The following provisions constitute Deemed-to-Comply provisions pursuant to the Codes and development standards under the City of Kwinana Town Planning Scheme No. 2 for all lots with no lane access and frontage greater than 13m. All other Deemed-to-Comply provisions of the R-Codes and Local Structure Plan apply. TABLE 1.3 RELEVANT R-CODE CLAUSE Setbacks 5.1.2 C2.1 - C2.4 Building Design Additional Requirement ACCEPTABLE DEVELOPMENT PROVISIONS VARIATION / ADDITIONAL REQUIREMENT Buildings setback from the primary street as follows: Minimum Setback - 2m. Note: the front setback averaging provision of the R-Codes does not apply. Buildings set back 1m from the secondary street. Garages may be setback to a minimum of 3.5m, provided the garage is not forward of the dwelling alignment. Garages may be aligned with the dwelling provided they do not exceed 3m setback line. Dwellings shall provide the following: A principle pedestrian access (front door) that faces the primary street and is a dominant feature of the facade; and At least one of the following architectural features: gable/gablet portico (recessed or projecting) verandah with minimum depth of 1.5m feature wall Boundary Walls Private Open Utilities and Facilities 5.1.3 C3.2 5.1.4 C4 & 5.3.1 C1.1 5.4.5 For lots less than 350m² boundary walls are permitted to both side boundaries for two thirds of the length of the balance of the boundary behind the front setback in accordance with the R-Code requirements. Minimum open space of 35% (site cover 65%) subject to the provision of an Outdoor Living Area with: a) A minimum useable space of 30m², minimum dimension of 4m in accordance with the R-Codes ; and b) Located adjoining the northernmost or easternmost side boundary. All dwellings shall include a store room with a minimum area of 4m² and a minimum dimension of 1.5m constructed under the main roof of the dwelling or garage, accessible from the exterior of the dwelling or from within the garage in accordance with the R-Codes. Storage area shall have a minimum dimension of 1m where incorporated into a garage, and 1.5m dimension elsewhere. 11

www.cleplan.com.au Dwelling setback minimum 3m / average 6m from primary street as per R-Codes. STREET Garage setback 4.5m or 0.5m behind dwelling alignment as per R-Codes. GARAGE Boundary walls permitted as per R-Codes. Side boundary setback as per R-Codes. Rear boundary setback as per R-Codes. 2263-150-04 (15.08.2013), not to scale SETBACK REQUIREMENTS FOR LOTS LOTS CODED R20 Providence (Bollard Bulrush South)

1.4 Provisions applicable to lots coded R20 The following provisions constitute Deemed-to-Comply provisions pursuant to the Codes and development standards under the City of Kwinana Town Planning Scheme No. 2 for all lots coded R20. All other Deemedto-Comply provisions of the R-Codes and Local Structure Plan apply. TABLE 1.4 Building Design Private Open RELEVANT R-CODE CLAUSE Additional Requirement 5.1.4 C4 & 5.3.1 C1.1 ACCEPTABLE DEVELOPMENT PROVISIONS VARIATION / ADDITIONAL REQUIREMENT Dwellings shall provide the following: A principle pedestrian access (front door) that faces the primary street and is a dominant feature of the facade; and At least one of the following architectural features: gable/gablet portico (recessed or projecting) verandah with minimum depth of 1.5m feature wall Roof materials of dwellings and outdoor buildings shall be coloured in a dark recessive colour that is not visually prominent in respect to the local landscape. Colours shall generally be consistent with the following colours, which comprise of muted green-grey and blue-grey shades: PG1 - H6 PG1 - G6 PG1 - F6 PG1 - E6 PG1 - E7 PG1 - D7 PG1 - B6 PG1 - B7 Note: refer to Dulux Colour Specifier for further guidance. Minimum open space of 40% (site cover 60%) subject to the provision of an Outdoor Living Area with: a) Minimum useable space of 35m², minimum dimension of 4m, and may include the nominated secondary street setback area; and b) Located adjoining the northernmost or easternmost side boundary. 13

www.cleplan.com.au 2m setback to primary street. Verandahs and architectural features permitted to 1.5m. LEGEND Dwelling orientation / surveillance Restricted vehicular access PUBLIC OPEN SPACE STREET Single storey boundary wall only. STREET 2m setback to primary street. Verandahs and architectural features permitted to 1.5m. 1m setback to secondary street. Single storey boundary wall only. 2263-150-05 (15.08.2013), not to scale SETBACK REQUIREMENTS FOR R50 DENSITY LOTS Providence (Bollard Bulrush South)

1.5 Provisions applicable to R50 Density Sites The following provisions constitute Deemed-to-Comply provisions pursuant to the Codes and development standards under the City of Kwinana Town Planning Scheme No. 2 for the development of Grouped Dwellings on all R50 Density lots. All other Deemed-to-Comply provisions of the R-Codes and Local Structure Plan apply. TABLE 1.5 RELEVANT R-CODE CLAUSE Setbacks 5.1.2 C2.1 - C2.4 Boundary Walls 5.1.3 C3.2 ACCEPTABLE DEVELOPMENT PROVISIONS Buildings shall be setback from the primary street as follows: Minimum Setback 2m dwelling and 1.5m for verandah or front facade treatment Maximum Setback 4m Note: the front setback averaging provision of the R-Codes does not apply. Buildings shall be setback a minimum of 1 metre from the secondary street. VARIATION / ADDITIONAL REQUIREMENT Boundary walls up to external side boundaries where located behind the minimum front setback, within the following limits: Single Storey Maximum height - 3.5m Maximum length No limit Dwelling Design, Orientation and Surveillance Utilities and Facilities 5.2.3 C3.1 & C 3.2 5.4.5 The design of dwellings shall include an articulated front elevation in the direction of the Primary Street Orientation arrow shown on the LDP. This front elevation shall consist of at least one major habitable room overlooking the Public Open. Development is required to address all secondary streets where practical. A secondary street elevation is to be articulated and feature a suitable level of detail including windows and permeable fencing. Dwellings shall provide the following: A principle pedestrian access (front door) that faces the primary street and is a dominant feature of the facade; and At least one of the following architectural features: gable/gablet portico (recessed or projecting) verandah with minimum depth of 1.5m feature wall All dwellings shall include a store room with a minimum area of 4m² and a minimum dimension of 1.5m constructed under the main roof of the dwelling or garage, accessible from the exterior of the dwelling or from within the garage in accordance with the R-Codes. Storage area shall have a minimum dimension of 1m where incorporated into a garage, and 1.5m dimension elsewhere. 15

www.cleplan.com.au FOUR PACKS LEGEND Restricted vehicular access Garage access easement 2.5 metre minimum garage setback (1 metre from easement) Mandatory garage nil setback Designated garage location Primary dwelling orientation Dwelling setback 2m from POS boundary. PUBLIC OPEN SPACE Dwelling setback 1.5m from primary street. STREET 2.5 3.5 3.5 Side boundary setback as per R-Codes. 2.5 2.5 STREET 3.5 3.5 3.5 3.5 Dwelling setback 2.5m from secondary street. STREET 2263-150-06 (15.08.2013), not to scale SETBACK REQUIREMENTS FOR FOUR PACK LOTS Providence (Bollard Bulrush South)

1.6 Provisions applicable to four-pack lots The following provisions constitute Deemed-to-Comply provisions pursuant to the Codes and development standards under the City of Kwinana Town Planning Scheme No. 2 for all four pack lots. All other Deemedto-Comply provisions of the R-Codes and Local Structure Plan apply. TABLE 1.6 RELEVANT R-CODE CLAUSE Garage Location 5.2.1 C1.3 ACCEPTABLE DEVELOPMENT PROVISIONS VARIATION / ADDITIONAL REQUIREMENT The siting of garages shall comply with the vehicular access restrictions as shown on the Four Pack Plan. Garages shall be set back in accordance with the minimum setbacks as shown on the Four Pack Plan. Garages are not permitted forward of the designated location. Boundary Walls 5.1.3 C3.2 A nil setback is mandatory for the garages as shown on the Four Pack Plan. Setbacks 5.1.2 C2.1 - C2.4 Buildings fronting the primary (northern) street shall be set back a minimum of 1.5m. Buildings fronting the secondary (southern) street shall be set back a minimum of 2.5m from the street boundary. Note: the front setback averaging provision of the R-Codes does not apply. Side boundary setbacks in accordance with the R-Codes unless stated otherwise in this LDP. Side elevations of the dwellings are required to address the internal access leg where applicable through the use of major openings and architectural features. Dwelling Design, Orientation and Surveillance Private Open 5.2.3 C3.1 & C3.2 5.1.4 C4 & 5.3.1 C1.1 For lots fronting the secondary (southern) street boundary, dwellings shall address the street by providing the principle pedestrian access (front door) and at least one other major opening to a habitable room orientated to the street. Dwellings on corner lots shall provide a minimum of one habitable room window that has a clear view of the secondary street and secondary street setback area. The design of dwellings shall include an articulated front elevation in the direction of the Primary Street Orientation arrow shown on the LDP. This front elevation shall consist of at least one major habitable room overlooking the Public Open. For lots fronting the primary (northern) street, Minimum open space of 30% (site cover 70%) subject to the provision of an Outdoor Living Area with: a) A minimum useable space of 30m², minimum dimension of 4m in accordance with the R-Codes; and b) Located adjoining the northernmost or easternmost side boundary. Outbuildings 5.4.3 Any enclosed, non-habitable storage structures, such as storage sheds, are only permitted if attached to the dwelling and constructed of the same materials as the dwelling. 17

www.cleplan.com.au LEGEND Lots subject to AS3959 (Bush Fire Construction Standards) - as identified in approved Local Structure Plan (refer section 2.1) 6 metre minimum setback Public Open Public Open Public Open Public Open Public Open ROAD Bush Forever 2263-147C-07 (30.07.2013), not to scale BUSH FIRE PRONE AREAS Providence (Bollard Bulrush South)

PART TWO - ADDITIONAL PROVISIONS 2.1 Provisions applicable to dwellings in bush fire prone areas In addition to the provisions of Part One, dwellings shown on the Bush Fire Prone Areas Plan (opposite) as being subject to A53959 are to satisfy the requirements of table 2.1. TABLE 2.1 Setbacks Construction Standards DWELLINGS IN BUSHFIRE PRONE AREAS REQUIREMENT Dwellings to be set back a minimum of 6m from the primary street where indicated on the Plan. The setback requirement may be reduced where it can be demonstrated that the 6m setback is no longer required due to either: a) an increased BAL construction standard for the dwelling; or b) a reduced fuel load within the adjacent fire hazard as certified by a suitably qualified bush fire consultant. Dwellings as indicated on the Plan to be constructed to satisfy BAL 12.5 construction standard in accordance with AS 3959, unless otherwise certified by a suitably qualified bush fire consultant, to the satisfaction of the City of Kwinana. BAL rating is to be confirmed by suitably qualified bush fire consultant following subdivision and prior to construction in accordance with the approved Fire Management Plan. 19

www.cleplan.com.au LEGEND Lots subject to quiet house design - as identified in approved Local Structure Plan (refer section 2.2) Public Open Public Open Public Open Public Open Public Open ROAD Bush Forever 2263-147C-08 (30.07.2013), not to scale QUIET HOUSE DESIGN Providence (Bollard Bulrush South)

2.2 Provisions applicable to lots subject to Quiet House Design In addition to the provisions of Part One, dwellings shown on the Quiet House Design Plan (opposite) are to comply with Quiet House Design (package A) requirements, as set out in Table 2.2 below. TABLE 2.2 QUIET HOUSE DESIGN PACKAGE A AREA TYPE ORIENTATION REQUIREMENTS Bedrooms Living and Work Areas 2 INDOORS Facing Freeway 6mm laminated glazing Fixed, casement or awning windows with seals No external doors Side-on to Freeway 6mm (minimum) laminated glazing Closed eaves Away from Freeway No requirements Facing Freeway 6mm (minimum) laminated glazing Fixed, casement or awning windows with seals 35mm (min) solid core external doors with acoustic seals Sliding doors must be fitted with acoustic seals 3 Side-on to Freeway 6mm (minimum) glazing Closed eaves Away from corridor No requirements Other Indoor Areas Any No requirements OUTDOORS Facing corridor Minimum 2.0m high solid fence (e.g. brick, limestone or Hardifence) Outdoor Living Area 4 Side-on to corridor Picket fences are not acceptable Away from corridor No requirements Second Storey Facing corridor Acoustic engineer certification is required for the second storey of dwellings 1 See section on Mechanical ventilation/airconditioning in AS2107-2000 for further details and requirements. Closed eaves No vents to outside walls/eaves Mechanical ventilation/airconditioning 1 Mechanical ventilation/airconditioning Closed eaves No vents to outside walls/eaves Mechanical ventilation/airconditioning Mechanical ventilation/airconditioning 2 These deemed-to-comply guidelines adopt the definitions of indoor spaces used in AS2107-2000. A comparable description for bedrooms, living and work areas is that defined by the Building Code of Australia as a habitable room. The Building Code of Australia may be referenced if greater clarity is needed. A living or work area can be taken to mean any habitable room other than a bedroom. The Building Code of Australia describes these utility spaces as non-habitable rooms. 3 Glazing panels are acceptable in external doors facing the transport corridor. However these must meet the minimum glazing requirements. 4 The Policy requires that at least one outdoor living area can be reasonably protected from transport noise. The protected area should meet the minimum space requirements for outdoor living areas, as defined in the Residential Design Codes of Western Australia. 21