SFH in Mautern AT. IEA SHC Task 37 Advanced Housing Renovation with Solar & Conservation

Similar documents
Apartment Building in Brogården, Alingsås SE

Apartment building in Albertslund, DK

measures of apartment buildings

Maratonvägen 36. Project summary. Energy concept: To achieve a substantial reduction of the energy losses.

ENERGY EFFICIENCY IN BUILDINGS

Wijk van Morgen, Kerkrade

Energy variations in apartment buildings due to different shape factors and relative size of common areas

Renovating older apartment buildings A multi-disciplinary international project. Architectural design & construction

Energy Efficient and Passive House Building Design Guidelines

Energy consumption in an old residential building before and after deep energy renovation

Content. An Introduction to FmK ECOHomes

Section 3 Case studies

BUILDING SPECIFICATIONS

Emil Møllers Gade 41 Horsens, Denmark

MONITORED RESULTS FROM AN INNOVATIVE SOLAR RENOVATION OF MULTI STOREY HOUSING - EU SHINE ENGELSBY, FLENSBURG

Underwood Court Ground Floor

GLAZED BALCONIES AND SUN SPACES ENERGY SAVERS OR ENERGY WASTERS?

The first stone building in Žvėrynas and the first street paved with cobblestones: Birutės Street 18. Authentic historical heritage of Vilnius

1. Good Practice Example: Retro-fitting (Brogården, Alingsås, Sweden)

KING RICHARD DEVELOPMENT

The first stone building in Žvėrynas and the first street paved with cobblestones: Birutės Street 18. Authentic historical heritage of Vilnius

The first stone building in Žvėrynas and the first street paved with cobblestones: Birutės Street 18. Authentic historical heritage of Vilnius

The first stone building in Žvėrynas and the first street paved with cobblestones: Birutės Street 18. Authentic historical heritage of Vilnius

ANHALT RENOVATION + ADDITION Historic Preservation + Multifamily Residential Seattle, WA

Passive House Renovation

The first stone building in Žvėrynas and the first street paved with cobblestones: Birutės Street 18. Authentic historical heritage of Vilnius

Estonian energy policy and EPBD: Deep integrated renovation with KredEx renovation grant programme

B Application example

Indoor climate of an unheated apartment and its impact on the heat consumption of adjacent apartments

FLOOR PLANS. 62 GERMANY ISLAND - The Heart of Europe GERMANY ISLAND - The Heart of Europe 63

Advisory Design Panel Report For the Meeting of February 27, 2019

Potential Building 6-Storey (Allowable) 50' Shoulder ALEXANDER STREET. Evelyne Saller Centre Main Entrance. Rodan Lodge Entry Porch

Residence 51. LOCATION John Kennedy Area, Limassol. STATUS Under Construction for SALE. COMPLETION DATE September 2010

Kouvola E2 Timber Concept Competition. Team Kaufmann

IEA ECBCS Annex 50 Prefab Retrofit of Buildings. Vorgefertigte Fassaden- und Dachelemente in der Sanierung

BUILDING QUALITIES Santa Pola Bahia Arena GROUNDING WORKS STRUCTURE

CURRICULUM VITAE Lars Junghans (PhD)

World Renewable Energy Congress (WRECX) Editor A. Sayigh 2008 WREC. All rights reserved. 822

LEGEND. A Apartments. T Townhouses

ACCESSORY DWELLING UNITS

Energy efficient renovation of building stock of Jugla

SHORT DESCRIPTION DORFSTRASSE Wengen DORFSTRASSE WENGEN NEW APARTMENTS WITH LIFT ABOVE SWISS MADE SHOP AND FRESH MARKET

Presentation of a new passive houses

Residential Complex jenbach a

CHANGE IN VALUE ALTERATIONS MADE OCCUPANCY CHANGES

The Aviary Munstead Godalming Surrey GU8 4AR

LOW ENERGY BUILDING DESIGN MORPHOLOGY

Residencial Doña Ines F 1

ESLA 5116 is a prime quality residential complex consisting of three luxurious buildings.

Lighting standards in renovated buildings

Study of the energy performance of Korean apartment buildings with alternative balcony configurations

New Development Exclusive 4 Bed Homes Size: c.1,760 sq.ft (164 sq.m)

An exclusive development of 4 designer villas with stunning sea views

ACCESSORY DWELLING UNITS

Underfloor. Heating Kits

Andraus high-rise, Sao Paulo, Brazil, February 1972

4 Bedroom Family House Lakeside Village of Altaussee

Tigh-Na-Cladach. Case Study produced by the A+DS Sust. Programme.

Eskside, East Mains, Edzell

Eskside, East Mains, Edzell

Tenement Refurbishment and Community Regeneration. Bellsmyre Housing Association, Merkins Avenue, Bellsmyre, Dumbarton

Buy a passive house in a micro residential area, modern, comfortable, all houses are very efficient with a very low energy consumption (90% less than

YO UR HOME AT THE BEACH

PROPERTY FACTS. Your Green Office In The Heart of The City

Beschreibung I M B A T E C K G I M B A T E C K G I M B A T E C K G. Mehrfamilienwohnhaus Wien; Julius Payergasse Wien im April 2013

Attic Floor Bedrooms 1 & 2 Family Dwellings

Published in: NSB 2014: 10th Nordic Symposium on Building Physics June 2014 Lund, Sweden

SOLHUSEN I GÅRDSTEN. olar buildings in Gårdsten

Residencial Galera Playa - Edificio Bergantín Camino de La Galera,

INVESTMENT OFFER Office space Mircea Vasilescu

paddington house words by Tom Rubenach

UCSD Revelle College Apartments

Construction scheme "Am Kaiserforum", 1010

DIRECTLY FROM THE DEVELOPER VILLA ALGAIDA. Country house with pool area, balcony and roofed terrace near Algaida

Residencial Altos del Sabinal - "Viviendas desde *. Plaza y Trastero Incluido"

Rawlinson House, Lewisham, London SE13 5EL

OPERABLE ALL-GLASS BALCONY GLAZING SYSTEMS. NanaGlass SL25

Villamartín LOCATION PLOT PLAN. Golf course. La Zenia Boulevard

Residencial Cármenes Balcón de Granada c/ Zahareña (Barranco del Abogado),

PROJECT TYPE MULTI-RESIDENTIAL PROJECT ADDRESS CHAPEL STREET SOUTH YARRA, VICTORIA AUSTRALIA

Residencial El Prado - "Viviendas desde *. Plaza y Trastero Incluido" Ensanche de Vallecas (caseta nº 1)

INRODUCTION STATISTIC DATE OF DWELLINGS STOCKS IN POLAND.

Available online at ScienceDirect. Energy Procedia 78 (2015 )

TRIALLIANCE COMMERCIAL REAL ESTATE SERVICES COLUMBIA STATION Route 108, Old Annapolis Road Columbia, MD 21045

Residential Energy Credits

BAUHAUS IN THE HEART OF PASARÉT, 1026 BUDAPEST, HŰVÖSVÖLGYI ST 53/B

148,000 sq ft. Net area of Grade A Office Accommodation

Greening up your Apartment?

Robustness of multi-objective optimization of building refurbishment to suboptimal weather data

Building study Edgley Design Godson Street

Apartment Lifts There are individual lifts dedicated to the Building. Security lifts to all levels including car park.

The Coach House. For Sale by Private Treaty

BUILDING SPECIFICATIONS REPORT VISTABELLA GOLF VILLAS FOUNDATIONS AND STRUCTURE Earthquake-proof reinforced concrete, in compliance with regulations.

Energy Efficiency in Urban Renewal of a UNESCO-listed historical centre The case of Porto. Ana Paula Delgado PORTO VIVO, SRU

New Perspectives. for Your Business

Energy Efficiency and Urban Renewal of a UNESCO-listed historical centre: The case of Porto. Álvaro Santos Paulo Valença José Pacheco Sequeira

Stark HS. Housing Solutions. By:

Makes Dreams a Reality

Memo to the Planning Commission HEARING DATE: JUNE 30, 2016

Berlin's post soviet refurbishment strategy - lessons learned (Filip Milojkovic, IWO e.v.)

Transcription:

SFH in Mautern AT PROJECT SUMMARY Renovation of a single-family house, built in the 1950ies, with vertical enhancement for a second housing unit and a new staircase. Complies with low energy requirement. SPECIAL FEATURES - components of a Passive House in the first floor - central mechanic ventilation system with heat recovery - air/air heat pump ARCHITECT Architect Dipl. Ing. FH Thomas Abendroth OWNER DI Karin und DI Dr. Reinhard Thayer Private IEA SHC Task 37 Advanced Housing Renovation with Solar & Conservation

Before After BACKGROUND This single family house in Mautern near Vienna was built in the fifties with a central gas heating system, a central preparation of domestic hot water by electricity and a typical building envelope with a space heat demand of 332 kwh/(m²a). After the renovation in 2004 and addition of a storey in wooden framing, the whole building complies to low energy requirements. The space heating demand is 41 kwh/(m²a). OBJECTIVES OF THE RENOVATION Double the living space Reduce heating costs to a minimum Use a high degree of pre-fabrication Comply with low energy requirements in the new storey Conservation of the garden area Renovation with least disturbance of neighbors Construct an economic building SUMMARY OF THE RENOVATION Renovation Lasting quality Insulation: roof (400 mm), façade (300 mm) basement ceiling (180 mm) Triple glazed windows in the upper floor Enhancement of the ground floor Use of prefabricated wall units (first floor) New balconies for the first floor Addition of a staircase More glazing at the ground floor Mechanical ventilation system with heat recovery and air/air heat pump for the first floor Section First floor Ground floor

CONSTRUCTION Removing existing roof Prefabricated walls Construction south terrace Roof construction U-value: 0.112 W/(m² K) (interior to exterior) plasterboard 15 mm air space 36 mm OSB airtight cellulose insulation 400 mm AGEPAN softboard ventilation space 80 mm boards, roof covering metal 24 mm 587 mm Wall construction (interior to exterior) plasterboard air space OSB airtight cellulose insulation AGEPAN softboard ventilation space lathing boarding U-value: 0.143 W/(m² K) Basement ceiling (top down) slab floor screed insulation polystyrene concrete floor U-value: 0.194 W/(m² K) 15 mm 36 mm 300 mm 50 mm 25 mm 25 mm 483 mm 30 mm 60 mm 180 mm 160 mm 430 mm Window first floor: triple thermopane glazing Ug: 0.7 W/(m² K) Uw: 1.0 W/(m² K) Window section south terrace

North-east facade New staircase Summary of U-values W/(m² K) Attic floor Walls Basement ceiling Windows BUILDING SERVICES Before 1.3 1.5 0.9 ca. 1.4 After 0.11 0.14 0.19 1.00 The building meets the local low energy requirement standard* by means of high insulation of the top floor, walls and floors, reductions of thermal bridges, glazing with Passive House quality windows in the first floor and an air tight envelope. A new central ventilation system with heat recovery (efficiency 85%) and air/air heat pump is installed in the new storey. The preheating of the cold air is done with a ground-air heat exchanger. The new floor heating in the upper floor and the radiators in the ground floor are supplied by the central gas heating, which also heats the domestic hot water. RENEWABLE ENERGY USE Opportunity for future installation of PV. ENERGY PERFORMANCE Space + water heating (primary energy)* Before: 495.56 kwh/(m² a) After: 186.43 kwh/(m² a) Reduction: 62% (existing gas heating) Future reduction: 83% (new geothermal heat pump) *according to OIB Richtlinie 6 INFORMATION SOURCES Architekt Dipl.Ing. FH Thomas Abendroth Linke Wienzeile 178/Stiege 2./ 5 St. AT-1060 Wien www.abendroth.at Brochure authors Sophie Grünewald, Sigrun Rottensteiner Contact Thomas Mach thomas.mach@tugraz.at TEAM AUSTRIA

PROJECT SUMMARY P1 Apartment building in Kierling P2 5 story apartment house in Linz P3 Enhancement house Wimmer in St. Valentin P4 Single-family house in Pettenbach P5 Old people s home in Landeck P6 Housing in Purkersdorf P7 Historic building in Irdning P8 Enhancement in Mautern P9 Attic conversion in Innsbruck P10 House Schilchegger in St. Martin P11 Single-family house Kraiger in Kufstein P12 Apartmentbuildings in Dornbirn PROJECTS in AUSTRIA P5 P2 P4 P3 P7 P1 P8 P6 IEA SHC Task 37 Advanced Housing Renovation with Solar & Conservation