Accessible drinking fountain does not have a clear 30 wide floor space centered on the drinking fountain (centerline to the counter edge is 12 ).

Similar documents
Existing Building Accessibility Quick Checklist (CBC 11B) Job Address Permit

Residential Accessible, Type A, and Type B Dwelling Unit Requirements 2012 International Building Code and 2009 ICC/ANSI A117.1

THIS CHECKLIST HAS BEEN AMENDED TO INCLUDE ONLY LEVEL ONE CRITERIA AS REQUESTED BY TIR REAL PROPERTY. As such it does not form a complete Checklist.

Regulation Outline. Under section 59 of the Community Planning Act, the Lieutenant-Governor in Council makes the following Regulation:

Schedule C Barrier-Free Design

Arlington County. Smart Choice Homes. Arlington County. Homes for all of us. Homes for a lifetime. Home

2012 Texas Accessibility Standards Reference Guide for changes to the code

Accessibility and ADA: Facility Standards Update. Technical Specifications: Chapters 8-10

Ontario s 2012 Building Code Barrier-Free Design Amendments Ontario Regulation 332/12 Amended by O. Regs. 368/13 and 191/14

ADA/TAS Plan Review & Inspection Worksheet Texas Access

General Information. Location Information. Location Use. Colorado VSPC/Drop-off/Drop-box Accessibility Survey Form. For SOS office use only

ADAPTABLE DESIGN GUIDELINES

HANDICAPPED ACCESSIBILITY TOOLKIT

Understanding Accessibility Features to Meet Housing Needs

Understanding Accessibility Features to Meet Housing Needs

Existing Property Accessibility Checklist

APPLICATION OF SECTION 3.8 OF THE 2012 ONTARIO BUILDING CODE FOR: BARRIER-FREE AUDIT OF SENECA COLLEGE NEWNHAM CAMPUS TORONTO, ONTARIO

During the Civil Rights Era

/7/2016. During the Civil Rights Era LAWS PROHIBITING DISCRIMINATION BASED ON DISABILITY IN HOUSING. Architectural Barriers Act of 1968

Section 3: Primary Function, Employee Work Areas, & Kitchens

12/18/2017. Objective. Accessibility Code MN 1341 Frequent Questions and Key Criteria. Agenda. Code Documents

NEW HOME UNIVERSAL DESIGN CHECKLIST (AB 1400)

National Trust Cottages Access Statement/Guide

CAS PAR. Comprehensive Assessment and Solution Process For Aging Residents INTRODUCTION MATERIALS NEEDED 1 CASPAR

Accessible Facilities Report Template

Codes Checklist Document 3

Utopia Gymnastics Accessibility Guidance. Utopia Gymnastics

Universal Design Policy

DEPARTMENT OF DEVELOPMENT SERVICES ACCESSIBILITY CHECK LIST FOR MULTI-FAMILY RESIDENTIAL BUILDINGS

A. Robert Kucab Executive Director

Access Statement for Primrose Farm

General Statement Regarding Assessment Analysis Recommendations

Investigation Reference No. Investigation Status. Investigation Description

Copyright 2013, Queen s Printer for Ontario

Trerice Access Statement

National Trust Cottages Access Statement

The New NYC Building Code Chapter 11 Accessibility. New York City Department of Buildings. Technical Affairs. Keith Wen, R.A. Copyright Materials

Access Statement for Dellfield Self-Catering unit

BUILDING CODE INTERPRETATION

11A Accessibility Standards Frequently Asked Questions for Residential Projects

3. Miscellaneous Instructions and Definitions.

ACCESS STATEMENT FOR the Byre AT BIRLING NORTH COTTAGE. Pre-Arrival. Parking. the East Coast Main Line is approximately 4km to the north.

Access Statement for Elk Cottage, Glassonby Old Hall, Glassonby, Penrith Introduction

ACCESSIBILITY CHAPTER 11

ACCESS STATEMENT FOR THE HEMMEL

Give the name and distance of the nearest railway station. Describe the type of surface from the car park to the main entrance.

National Trust Cottages Access Statement

National Trust Cottages Access Statement/Guide

National Trust Cottages Access Statement

Access Statement Seaton 22 St Aidan s Seahouses NE68 7SS

Accessible Plumbing Fixture Requirements

Charles Kozminski Elementary Community Academy

Fair Housing Amendments Act - Basic Design Issues - FHAA Design Requirements

Accessibility in Alberta

LOCATION RFM ROAD, CABUYAO, LAGUNA

National Trust Cottages Access Statement Cottage Ref The Farmhouse Middlebere Farm Arne Isle of Purbeck

Give the name and distance of the nearest railway station. Describe the streets in the area surrounding the property

The Design and Construction Requirements of the Fair Housing Act: Technical Overview

National Trust Cottages Access Statement

Americans with Disabilities Act Transition Plan Barrier Removal Database Project Listed by Type

Access Statement Aidanfield Fenwick Berwick upon Tweed TD15 2PJ

Campbell 508 OPTIONAL BASEMENT DEVELOPMENT SQ.FT. 3 BED 2.5 BATH 2012 FINISHED SQ.FT. FRONT GARAGE HOME TWO STOREY FOR 34 LOTS. MAIN FLOOR 789 sq. ft.

Parking. Access Statement Summerhouse Cottage Beadnell. Pre Arrival. Chathill-3.5 miles/ Alnmouth-15 miles/ Berwick upon Tweed-25 miles

SKYLINE HOMES OF ARKANSAS CIT Y, KANSAS 24' 28' 32' SERIES

Affordable Rental Housing Design Guidelines

Housing Accessibility under the Americans with Disabilities Act and the Fair Housing Act. Building Code manual covers.

MANDATORY BUILDING STANDARDS FOR ADAPTABLE HOUSING

WORKSHEET FOR ACCESSIBILITY UPGRADE REQUIREMENTS FOR EXISTING NON-RESIDENTIAL BUILDINGS

ADAPTATIONS POLICY 2012

La Petit Jardin 118 Ruette Irwin, Fort George, St Peter Port

CONSTRUCTION COST ESTIMATE AND ANALYSIS

521 CMR: ARCHITECTURAL ACCESS BOARD MULTIPLE DWELLINGS

Renovation Progress. June 2-15, Weeks 35 & 36

Ithaca College Accessibility Guide

Access Statement The Hollies Ingram Road Bamburgh NE69 7BT

Access Statement for COASTGUARD COTTAGE, BAMBURGH

FOR SALE OR LEASE. Manufacturing / Distribution Facility 43,200± SF ± Acres. 302 Veterans Parkway Barnesville, Lamar County, Georgia 30204

NEW ACCESSIBILITY CHANGES

Kieran Boughan. San Francisco Architect RESIDENTIAL

Damascus

Accessible Housing by Design. CMHC Research & Information Transfer. Jamie Shipley C.E.T. Canada Mortgage and Housing Corporation

2014 OSSC CHAPTER 10 - MEANS OF EGRESS TABLE OF CONTENTS

Clouds Hill Access Statement

ARTICLE 3: RESIDENTIAL DISTRICTS

VERANDA ROAD HOUSING PROJECT ADA / UFAS SITE COMPLIANCE STUDY

Give the name and distance of the nearest railway station. Describe the floor surface e.g. tile/wood/rugs/carpet (thick/short pile).

Lodge Park Access Statement

ADAAG specifically defines requirements for shopping center handicapped parking and signage, sidewalk size, building access and interior layout.

National Trust Cottages Access Statement

2018 CSBC / 2018 CSFSC Part III. Chapter #10. Means of Egress. Table of Contents. Based on the 2015 IBC and the 2015 IFC.

The Benezet House. 13 Penn Center Circle E Director-Walter Mack Emergency contact Robert Lee Johnson

FOR SALE OR LEASE. Manufacturing / Distribution Facility 85,262± Square Feet (Divisible) Acres

Hotel Accessibility Pack

714 BRADDOCK VIEW DRIVE LEMONT FURNACE, PA FOR LEASE INDUSTRIAL MARKETING FLYER

Access Statement Cinnamere Cottage, Eastgate, Pickering

National Trust Cottages Access Statement Template

Access Statement Henderson House 19 Henderson Street Amble NE65 0AE

Facilities providing accommodation for the public (e.g. Hotels, hostels, guesthouses, self catering apartments).

SMART Access Assessment

Renovation Progress. July 21 Aug 3, Week 42 & 43

Transcription:

ADA STANDARD: PARKS SERVICE CENTER GARAGE 4.15.5(1), Figs. 4(e) and 27(b) Accessible drinking fountain does not have a clear 30 wide floor space centered on the drinking fountain (centerline to the counter edge is 12 ). Shorten the counter width by 3 (min.) to provide clear 30 wide floor space centered on the drinking fountain. Photo of drinking fountain

PARKS SERVICE CENTER GARAGE ADA STANDARD: 4.23.7, 4.27.2, 4.27.3, 4.2.5 and Fig. 5, 4.2.6 and Fig. 6 Height to operating latch on first aid cabinet is more than 48 above the floor (measured at 59-1/2 ). Adjust height of first aid cabinet so highest closed operable latch is not more than 48 above the floor. Photo of Parks Service Center

PARKS SERVICE CENTER GARAGE ADA STANDARD: 4.35.2, 4.35.4 Insufficient maneuvering clearance is provided between the edges of the benches and the lockers (measured at 54 ). A 24 x 48 bench is not provided for handicapped users (measured at 9-1/2 x 36 ). Adjust the benches so that a minimum of 60 turning diameter is provided within the locker room. Install a 24 x 48 bench for handicapped users to replace one or both of the existing two benches. Photo of Parks Service Center

ROBERT E. BURKE MEMORIAL PARK Photo of Robert E. Burke Memorial Park

ITEM: ADA GUIDELINE: ROBERT E. BURKE MEMORIAL PARK N/A N/A N/A N/A Photo of park

SHERIDAN PARK Photo of Sheridan Park

ITEM: SHERIDAN PARK ACCESSIBLE ROUTE ADA GUIDELINE: 4.1.2(1), 4.3 An accessible path is not provided to the picnic tables in the park. Add an accessible path to the picnic tables in the park. Photo of Picnic Tables in south portion of park

ITEM: SHERIDAN PARK PICNIC TABLE ADA GUIDELINE: 5.5, 306, 902.2, 902.3 An accessible space is not provided in the picnic table grouping that permits a wheelchair to pull under the end of one of the table sides. Remove one of the seat and horizontal arm assemblies to provide an accessible wheelchair space. Photo of Picnic Tables in south portion of park

A.C. NIELSEN TENNIS CENTER Photo of A.C. Nielsen Tennis Center

A.C. NIELSEN TENNIS CENTER ADA STANDARD: 4.1.3(1), 4.3.8 Second floor to Tennis Center has no lift or elevator (square footage is approximately 5115 sq. ft. on second floor). Install lift or elevator to second floor. Photo of second floor of A.C. Nielsen Tennis Center

A.C. NIELSEN TENNIS CENTER ADA STANDARD: 4.13.9 Door knob on first floor boiler room door is round and hard to grasp. Replace round door knob with lever knob that is accessible. Photo of door on first floor boiler room door of A.C. Nielsen Tennis Center

A.C. NIELSEN TENNIS CENTER ADA STANDARD: 4.13.9 Door knob on first floor manager s office door is round and hard to grasp. Replace round door knob with lever knob that is accessible. Photo of door on first floor manager s office door of A.C. Nielsen Tennis Center

A.C. NIELSEN TENNIS CENTER ADA STANDARD: 4.13.9 Door knob on first floor storage room door is round and hard to grasp. Replace round door knob with lever knob that is accessible. Photo of door on first floor storage room door of A.C. Nielsen Tennis Center

A.C. NIELSEN TENNIS CENTER ADA STANDARD: 4.13.9 Door knob on first floor AED closet room door is round and hard to grasp. Replace round door knob with lever knob that is accessible. Photo of door on first floor AED closet room door of A.C. Nielsen Tennis Center

A.C. NIELSEN TENNIS CENTER ADA STANDARD: 4.13.9 Door knob on second floor closet in southeast corner is round and hard to grasp. Replace round door knob with lever knob that is accessible. Photo of storage room door on southeast corner of second floor of A.C. Nielsen Tennis Center

A.C. NIELSEN TENNIS CENTER ADA STANDARD: 4.13.9 Door knob on top of second floor stairwell in northwest corner is round and hard to grasp. Replace round door knob with lever knob that is accessible. Photo of door at top of stairwell at northwest corner of second floor of A.C. Nielsen Tennis Center

A.C. NIELSEN TENNIS CENTER ADA STANDARD: 4.13.9 Door knob on second floor hallway at southeast corner is round and hard to grasp. Replace round door knob with lever knob that is accessible. Photo of door on hallway second floor in southeast corner of A.C. Nielsen Tennis Center

ADA STANDARD: A.C. NIELSEN TENNIS CENTER 4.15.5(1), Figs. 4(e) and 27(b) Drinking fountain inside east side of the center of the building entrance is not accessible since the unit does not allow 27 of wheelchair access under the unit. Install new drinking fountain that has 27 of wheelchair access under the unit. Photo of drinking fountain inside the east side of the center of A.C. Nielsen Tennis Center

ADA STANDARD: A.C. NIELSEN TENNIS CENTER 4.15.5(1), Figs. 4(e) and 27(b) Drinking fountain in aisle between the tennis courts is not accessible since the unit does not allow 27 of wheelchair access under the unit and the spout is higher than 36 above floor (measured at 46 to spout). Install new drinking fountain that has 27 of wheelchair access under the unit and a spout no higher than 36 above the floor. Photo of drinking fountain in the aisle between the tennis courts of A.C. Nielsen Tennis Center

A.C. NIELSEN TENNIS CENTER ADA STANDARD: 4.4.1 Boxes over thermostats in southeast corner of second floor project out more than 4 and are above 27 high. Replace covers with models that do not project out more than 4 from wall. Photo of thermostat boxes in second floor southeast corner of A.C. Nielsen Tennis Center

A.C. NIELSEN TENNIS CENTER ADA STANDARD: 4.4.1 Five fire extinguishers on throughout building project out more than 4 and are higher than 27 above the floor (measured at 43 above floor). Lower 5 fire extinguishers so the bottom edges are no more than 27 above the floor. Photo of fire extinguisher on second floor of A.C. Nielsen Tennis Center

A.C. NIELSEN TENNIS CENTER ADA STANDARD: 4.19.6 Mirrors in restrooms are mounted higher than 40 to bottom reflecting surface (measured at 45 to ground). Lower bottom edges of mirrors to 40 above ground. Photo of mirror in restrooms of A.C. Nielsen Tennis Center

ADMINISTRATIVE OFFICE Photo of Administrative Office

ADMINISTRATIVE OFFICE ADA STANDARD: 4.19.2 West women s single user restroom sink exceeds 34 height above floor (measured at 35 ). Lower sink to 34 height above floor. Photo of west women s single user restroom

ADMINISTRATIVE OFFICE ADA STANDARD: 4.19.6 All four (4) single user restroom mirrors exceed 40 height above floor (measured at 41 ). Lower mirrors to 40 height above floor. Photo of east women s single user restroom

ADMINISTRATIVE OFFICE ADA STANDARD: 4.19.4, 4.17.6 Horizontal grab bars in two (2) west single user restrooms are less than 36 long (measured at 30 ). Install 36 long horizontal grab bars. Photo of west men s single user restroom

ADMINISTRATIVE OFFICE ADA STANDARD: 4.25.3 Coat hooks in all four (4) single user restrooms exceed 54 height above floor (measured at 63 ). Either lower existing coat hooks to 54 height above floor or add new hooks at 54 height above floor. Photo of east men s single user restroom

BALLFIELD STORAGE - SHELTER Photo of Ballfield Storage - Shelter

BALLFIELD STORAGE - SHELTER ADA STANDARD: 4.1.6(3)(d)(ii), 4.13.8 Threshold at building entrance exceeds ¾ height (measured at 3 high). Install gravel, concrete or asphalt ramp to top of threshold and into the building. Photo of double door entry

BALLFIELD STORAGE - SHELTER ADA STANDARD: 4.3.8 Elevation change between concrete pad and adjacent gravel exceeds ½ height. Install gravel to meet height of concrete pad. Photo of north side

BALLFIELD STORAGE- -SHELTER ADA STANDARD: 4.4.1 Building logs project out greater than 4 into accessible pathways above 27 from floor (measured at 29 and 37 ). Install barriers so the top of the barricade is at 27 or below underneath building projections. Photo of south side

CART BARN Photo of Cart Barn

CART BARN ADA STANDARD: 4.13.5, 4.13.6 Hose hook located inside door inside southwest corner of Cart Barn does not allow 32 clear passage and maneuvering room. Relocate hose hook location away from the door to allow 32 clear passage. Photo of southwest corner of interior

CART BARN ADA STANDARD: 4.13.9 Southwest and northeast pedestrian doors have round handles which are difficult for the disabled to grasp. Replace door handles with lever-style handles. Photo of southwest door

CART BARN ADA STANDARD: 4.4.1 Hose reel projects out more than 4 and has bottom edge higher than 27 above the floor. Lower hose reel so bottom edge is below 27 above the floor. Photo of hose reel

CART BARN ADA STANDARD: 4.4.1 Fire extinguisher next to southwest door projects out more than 4 and has bottom edge higher than 27 above the floor (measured at 30 ). Lower fire extinguisher so bottom edge is below 27 above the floor. Photo of southwest fire extinguisher

CART BARN ADA STANDARD: 4.4.2 Double vent on west wall of building projects out more than 4 and is below 80 above the floor. Install barrier below double vent with bottom edge below 27 above the floor (i.e. panels on sides of vent or bumpers or bollards on floor. Photo of double wall vent

CART BARN ADA STANDARD: 4.4.1 Hose hook projects out more than 4 with bottom edge higher than 27 above the floor. Relocate hose hook to a new location with bottom edge below 27 above the floor. Photo of hose hook

CELL PHONE BUILDING - NORTH Photo of Cell Phone Building - North

CELL PHONE BUILDING - NORTH ADA STANDARD: 4.1.2(1), 4.3, 4.3.8, 4.1.3(1) Stairs to door at south side of building are not accessible (5 risers at 8 each are more than the ½ maximums required). Add a ramp to north cell phone building (and south cell phone building) to berm and top of stairs. Photo of stairs

CELL PHONE BUILDING - NORTH ADA STANDARD: 4.13.6, Fig. 25 On latch pull side of door, there is not 18 of clearance to edge of stair tread (measured at 6 ). Rebuild railings and stairs to provide a full clearance of 18 from edge of latch pull side of door to edge of stair tread and 48 clearance from building to railings. An alternative is to flip door hinge/latch sides and add concrete extension on uphill side of landing to 18 from latch side of door. Photo of stairs

CELL PHONE BUILDING - SOUTH Photo of Cell Phone Building - South

CELL PHONE BUILDING - SOUTH ADA STANDARD: 4.1.2(1), 4.3, 4.3.8, 4.1.3(1) Stairs to door at south side of building are not accessible (5 risers at 8 each are more than the ½ maximums required). Add a ramp to south cell phone building (and north cell phone building) to berm and top of stairs. Photo of stairs

CELL PHONE BUILDING - SOUTH ADA STANDARD: 4.13.6, Fig. 25 On latch pull side of door, there is not 18 of maneuvering clearance to edge of landing (measured at 6 ). Also, there is a hole in concrete landing. Add paving to 18 from edge of latch pull side of door. Fill in hole. Photo of stairs

CLUBHOUSE Photo of Clubhouse

CLUBHOUSE ADA STANDARD: 4.4.2 Overhanging trees on the path to the clubhouse from the parking lot have branches below 80 height. Cut any branches overhanging the path to above 80 height. Photo of path looking west from the parking lot to the Clubhouse

CLUBHOUSE ADA STANDARD: 4.3.8 Pavement adjacent to the driving range ball dispenser is uneven and not level with adjacent concrete pad. Add asphalt to bring surface level with adjacent concrete pad to permit user to get closer to dispenser. Photo of driving range ball dispenser on east side

CLUBHOUSE ADA STANDARD: 4.4, 4.2.1(3), 4.1.3(2) Exterior light fixtures and hanging flower baskets project into accessible routes over 4 and are located between 27 and 80 above the ground (measured at 8 projection and 65 high to the bottom of the light fixtures and 28 projection and 72 high to the bottom of the flower baskets). Replace light fixtures with style that does not project more than 4 into an accessible route. Raise hanging baskets to above 80 ground or relocate to other locations where at least 80 exists. Photo of exterior column on front porch

CLUBHOUSE ADA STANDARD: 4.1.3(1), 4.1.6(3)(d)(ii), 4.13.8 West entrance to the Clubhouse is not accessible (threshold to doors exceeds ¾ height; measured at 6 risers) and has no sign directing user to the accessible entrance (main south entrance). Install a permanent sign directing disabled users to the main south entrance. Photo of west entrance

CLUBHOUSE ADA STANDARD: 4.1.3(1), 4.13.6, Fig. 25 North entrance to the Clubhouse is not accessible (insufficient clearance of 18 on latch side of the door; measured at 6 ) and has no sign directing user to the accessible entrance (main south entrance). Install a permanent sign directing disabled users to the main south entrance or add pavement to latch side of door to provide a minimum of 18 clearance. Photo of north entrance

CLUBHOUSE ADA STANDARD: 4.1.3(1), 4.1.6(3)(d)(ii), 4.13.8 North entrance to the Clubhouse pro s office is not accessible (threshold exceeds ¾ due to settled asphalt outside the door) and has no sign directing user to the accessible entrance (main south entrance). Install a permanent sign directing disabled users to the main south entrance or add asphalt to top lip of concrete floor. Photo of north entrance to the pro s office

CLUBHOUSE ADA STANDARD: 4.13.6 Clearance space on the pull side of the latch side of the north office door is less than 18 (measured at 4 ) due to drawer unit and shelf unit. Relocate drawer and shelf unit to provide a minimum of 18 clearance on the latch side of the door. Photo of north office

CLUBHOUSE ADA STANDARD: 4.13.6 Clearance space on the pull side of the latch side of the door is less than 18 (measured at 5 ) due to metal shelving unit. Relocate shelving unit to provide a minimum of 18 clearance on the latch side of the door. Photo of kitchen storage room

CLUBHOUSE ADA STANDARD: 4.13.6 Clearance space on the pull side of the latch side of the door from the hallway into the kitchen area is less than 18 (measured at 2 ) due to pop boxes. Relocate pop boxes to provide a minimum of 18 clearance on the latch side of the door. Photo of door from hallway to kitchen area

CLUBHOUSE ADA STANDARD: 4.13.6 Clearance space on the pull side of the latch side of the door from the pro s office into the driving range machine room is less than 18 (measured at 3 ) due to lockers. Relocate double height locker to provide a minimum of 18 clearance on the latch side of the door. Photo of pro s office driving range machine door

CLUBHOUSE ADA STANDARD: 4.13.9 The round knob on the door into the driving range machine room is hard to grasp for the disabled. Replace the door knob with a lever type to match the other door knobs in the Clubhouse. Photo of pro s office driving range machine door

CLUBHOUSE ADA STANDARD: 4.13.6 Clearance space on the pull side of the latch side of the pro s office storage door is less than 18 (measured at 6 ) due to display units. Relocate display units to provide a minimum of 18 clearance on the latch side of the door. Photo of pro s office storage room

CLUBHOUSE ADA STANDARD: 4.4.1 Interior wall lights (total of 3) in rear hallways project out further than 4 with the bottom edge of the fixture between 27 and 80 above the floor (measured at 10-1/2 projection and 62-1/2 above the floor). Replace fixtures with units that do not project more than 4 from the wall or install with the bottom of the light above 80 from the floor. Photo of rear hallway

CLUBHOUSE ADA STANDARD: 4.4.1 Interior wall lights (total of 4) in the classroom project out further than 4 with the bottom edge of the fixture between 27 and 80 above the floor (measured at 7 projection and 79 above the floor). Replace fixtures with units that do not project more than 4 from the wall or install with the bottom of the light above 80 from the floor. Photo of classroom

CLUBHOUSE ADA STANDARD: 4.4.1 Fire extinguisher in rear hallway projects out further than 4 with the bottom edge of the fixture between 27 and 80 above the floor (measured at 5 projection and 33 above the floor). Reset fire extinguisher with the bottom edge at 27 above the floor. Photo of north hallway fire extinguisher