Misawa Building (Hostess Bar "Raku Raku")

Similar documents
Andraus high-rise, Sao Paulo, Brazil, February 1972

USFA-TR-019/January 1988 Homeland Security

Occupants: Behaviour in Response to the High-rise Apartments Fire in Hiroshima City

FIREFIGHTING PROCEDURES VOLUME 1, BOOK 1, ADDENDUM 3 September 4, 2012 WIND IMPACTED FIRES IN FIREPROOF MULTIPLE DWELLINGS 1.

The Building: A 15 story building of Class I (Fireproof) Construction. 55 East 102nd Street, Manhattan:

Presentation By. Chris Poujol. Jeffery Rodriguez. James Rigley

REPORT TO COUNCIL. To: Mayor Schaffer and Councillors. UBCM Resolution on Sprinklers for 4-Storey Balconies. Report #:

PROPERTY CONDITION CHECK LIST FOR A LICENCED HMO

Regional District of Nanaimo Secondary Suite Program

I became responsible for the management of the Plaza on DeWitt Condominium Association

Emergency Evacuation and Stairwell Signage

SPECIFIC GUIDANCE FOR A BEDSIT TYPE HOUSE IN MULTIPLE OCCUPATION (HMO)

Hotel Accessibility Pack

Secondary Suites Changes between the 2006 ABC and the 2014 ABC Requirements

Access Statement for Quality Guest Accommodation

Property. Introduction

Discuss the history of fires that resulted in much of the development of codes related to means of egress. Review mean of egress terminology

There are three types of ownership and involvement with the management company:

B&NES Additional HMO Licensing Conditions

2.1 Alarm Source How was the alarm reported? UCT 911/ Phone, ERS, Class-3, BARS, Verbal.

Purpose. Scope. Stairway Identification Signs. Emergency Evacuation and Stairwell Signage Requirements

1. All registered guests of Mantra Circle on Cavill agree to abide by the Mantra Circle on Cavill House Rules;

High-Rise Fire Sample Scenario with Stairwell Pressurization by Steve Kerber Fire Engineering Simulation

2014 OSSC CHAPTER 10 - MEANS OF EGRESS TABLE OF CONTENTS

CITY OF MOUNT PLEASANT ORDINANCE NO. 1017

THEATER EVACUATION AND EMERGENCY SITUATION GUIDELINES THEATER EVACUATION

The Secondary Suite Program

Welcomes you! AMENITIES

Section 23.0 HOUSING QUALITY STANDARDS (HQS) INSPECTION POLICIES

TABLE OF CONTENTS WELCOME LETTER 1 MAINTENANCE REQUEST FORMS 2 DIRECTORY 3 BUILDING POLICIES 5 EMERGENCY PROCEDURES 8 FLOOR ACCESS PLAN 11

êéëé~êåü=üáöüäáöüí Code Requirements and Costs of Incorporating Accessory Apartments in Houses

Dispute Resolution Services Residential Tenancy Branch Office of Housing and Construction Standards Ministry of Housing and Social Development

Access Statement for Stoney Steps Flat 5 Ullswater Court Inn on the Lake Glenridding

City of South Portland Office of the City Clerk 25 Cottage Road South Portland, ME Registration of Short-Term Rental Checklist

The New NYC Building Code Chapter 10 Means of Egress. New York City Department of Buildings. Technical Affairs. Fatma M. Amer, P.E.

TOTAL ECONOMIC IMPACT OF MURRAY KY DOWNTOWN DISASTERS EXECUTIVE SUMMARY

Advice for Private Landlords Management of houses in multiple occupation

Place of Assembly. A Guide to the New York City Place of Assembly Process. Department of Buildings. New York City Fire Department

The Benezet House. 13 Penn Center Circle E Director-Walter Mack Emergency contact Robert Lee Johnson

20 Richman Plaza, Bronx The Building:

Damascus

Accessible Accommodation There are nine adapted accommodation units at Longleat:

Approved Document B Single stairways - Residential uses Part 1

OBTAINING A CERTIFICATE OF OCCUPANCY FOR UNAPPROVED DWELLING UNITS

BUILDING CODE COMMISSION

Equality and Access Plan The Abbey School, Reading

ACCESSORY DWELLING UNITS

The Fire Code: An Overview for Tenants FEDERATION OF METRO TENANTS ASSOCIATIONS

The Secondary Suite Program

ERRATA AND REVISIONS MEASURES FOR FIRE SAFETY IN HIGH BUILDINGS

5. Portable unvented fuel-fired heating equipment is prohibited. (IFC 603.4)

GOING DOWN. SS Monthly

THOMAS CENTER PHYSICAL IMPROVEMENTS

Guidelines for Reserving Facilities

CORY BREEGLE KENNY CHEUNG JEAN-PIERRE DEMERIUX GOMEZ DARWIN DIAZ. Team One

NY: UTICA - 4 DEAD LAWSUIT TO JURY - FD DON T GO IN POLICY FOR LOW-INCOME, MULTI-STORY BLDGS. ALLEGED

Appendix C Tips for Making an Inspection a Cooperative Rather Than an Adversarial Experience

Access Statement for Elk Cottage, Glassonby Old Hall, Glassonby, Penrith Introduction

DESCRIPTION OF LANDLORD'S WORK & TENANT'S WORK

PROPERTY INSPECTION REPORT

Jurys Inn Nottingham. Property. Introduction. Pre-Arrival

WELCOME TO GRADUATE HOUSING! Podiatry Residence Hall. 801 Cherry Street Philadelphia, PA 19107

Welcome To Your New Home.

DRS RWANDA STANDARD. Code of practice for fire safety. of building. Part 5: Exit requirements and personal hazard.

BUILDING CODE COMMISSION

INSTRUCTIONS FOR SIGNING THIS LEASE & DEPOSIT AGREEMENT

Phone: Fax: Fire Drills/Emergency Evacuations Protocol

Student Handbook General Building Welcome from TurnKey Housing Solutions

Lantern House - holiday cottage in the Cotswolds UK Access Statement

INFORMATION BULLETIN REPAIRS AND MAINTENANCE

Providence Fire Department Arson Squad

TIMBERLINE RIM RECREATION CLUB, INC. WEEKLY, MONTHY OR ONGOING LODGE RESERVATION AGREEMENT

WAIKIKI LANAIS HOUSE RULES

HANDICAPPED ACCESSIBILITY TOOLKIT

London Hilton on Park Lane: Accessibility Pack

Renovation Progress. June 2-15, Weeks 35 & 36

Contract for Clubhouse and Pool Rental

UNC Pembroke Building Evacuation Maps

ASTRA APARTMENTS CANBERRA THE GRIFFIN 15 TENCH ST, KINGSTON

RESEARCH PAPER AN AUDIT OF THE EGRESS SYSTEM IN MULTI-STOREY ANNEXES OF FOUR HALLS OF RESIDENCE AT KNUST, KUMASI, GHANA

Governors State University Tornado & Severe Weather Shelter Plan August 4, 2016

Stafford/Optimist Parks & Community Center Usage

ACCESSORY DWELLING UNITS

THE SEMINOLE OWNERS CORP / TH STREET FOREST HILLS, N.Y. HOUSE RULES. As of May 24, 2011

Single Point of Failure and Inter-relationship between Stair Pressurisation System and Evacuation Strategy for Tall Buildings

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

Understanding Accessibility Features to Meet Housing Needs

What are Landlord's and Tenant's rights and obligations? Discuss.

Statement of principles for determining financial penalties

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

Attic Floor Bedrooms 1 & 2 Family Dwellings

Do You Know Your Rights and Duties As a Renter?

IDP REPORT EDAN - CHELSEA WARD ECW 0021 STUDENT NUMBER :

Renovation Progress. May 5 11, Week 31

MINIMUM HMO & HOSTEL STANDARDS

ACACIA ASSOCIATION RENTAL AGREEMENT CLUBHOUSE, GREAT ROOM, 4-SEASON ROOM

Property. Introduction

Grand View at Crestwood Condominium Association, Inc. 50 Crestwood Ct. N. Royal Palm Beach, FL

THIS AGREEMENT made in duplicate this day of,, 20. The Chippewas of Georgina Island First Nation

HIGH-RISE BUILDING INVENTORY FORMS (B.I.F.) PRODUCTION AND APPROVAL

Transcription:

Building Name Address Use (as per FSA Annexed Table 1) Date and Time of Incident Structure and Stories Area Extent of Damage (Damaged Area/ Total Area) No. of Casualties Misawa Building (Hostess Bar "Raku Raku") 3-6 Takashima-machi Numazu SHIZUOKA I. Summary of Fire Incident Complex (16) a Dec. 26, 1976 Breakout at 01:30 (approx) Detected at 01:35 Notified by emergency call Extinguished by 02:25 Fire resistive 3 stories above ground and 1 below Building 120 m 2 Total floor 369 m 2 All, Half, Partial, Small 256 m 2 (69% ) Fatalities 15 Injured 8 ( ) (1) Summary The fire emerged from the 1st-floor landing of the stairwell whose interior was finished with combustible material. The 2nd floor of the small multi-tenant building was windowless because the windows were all closed off from inside. The intensive combustion and heavy smoke of this fire resulted in 15 fatalities (9 guests and 6 employees on the 2nd floor). (2) Conditions per Floor (3) Origin of Fire Floor Total Damaged Use (Purpose) No. of persons No. of fatalities Fire escape equipment m 2 m 2 1 set of inside stairs (1st to Roof floors) R 17.8 3 112.5 112.5 Office, Locker room 2 Hostess bar 22 (9 118.4 118.4 (Raku Raku) guests) 14 1 Retail, 119.8 25.1 Bookstore 1 Total 368.5 256.0 22 15 (Floor, Room, Part, Combustibles, Habitable/Non-habitable Rooms, Present/Absent) From the 1st floor landing of the stairwell The stairwell was comprised of walls and ceilings that were made of combustible-wallpapered plywood and a floor that was carpeted. (4) Cause of Fire 1 set of outside stairs (1st to 2nd floors) (Suspected arson) Firefighting equipment Fire extinguishers Guiding lights *During the investigation, the cause of fire was identified when a possible suspect accused of arson was arrested. He deliberately set fire to a cardboard box that he brought inside the entrance door of the 1st-floor landing of the stairwell.

(5) Fire Propagation Path (Location of Fire Source) Stairwell (Propagation from Source) A cardboard box was set on fire, which spread to the combustible interior finishing of the stairwell and the carpet. (Propagation to Adjacent Zones) (Propagation to Upper Floors) Spread through unsealed clearances around the shutter and the partially wooden exit door. Spread inside the bar via the stairwell and wooden door to the 2nd floor The fire that started on the 1st-floor landing of the stairwell ignited combustible wallpaper on the wall, which combusted intensively, and spread to the hostess bar on the 2nd floor. (A passerby who was near the 1st-floor entrance suffered burns because of the intense combustion.) In addition, the fire spread to the ceiling and walls of the retail shop through the entrance door (wooden door covered by galvanized sheet) and the unsealed clearances around the shutter that was installed between the stairwell and retail shop. Main Reasons for Propagation of the Fire The wall and ceiling were made of wallpapered plywood and the floor was covered in carpet, which were all combustible. The wooden door to the 2nd floor was also combustible. Smoke Propagation Path The smoke that was produced by the fire on the 1st floor landing filled the stairwell. Although the door to the 2nd floor was closed, the smoke penetrated gradually through the clearances. Once the door was opened by someone who noticed the smoke, a large amount of smoke surged ointo the floor. II. Summary of the Building (1) Built Construction, Completion, and Major Renovations (Completion) August 24, 1964 Fire Prevention Management (2) Vertical Shafts (3) Fire Prevention Stairwells Elevators Escalators [X] Duct spaces Pipe shafts Other ( ) [X] The interior of the stairwell was made of wallpapered plywood, and the fire compartment was incomplete. No fire-prevention manager. No fire defense plan. Furniture and plants were blocking the door to the outside stairs and interfered with the evacuation. The 2nd-floor windows were all covered by interior finishing materials. (4) Fire Compartment (5) Firefighting Equipment There were unsealed clearances around the shutter between the stairwell and retail shop. The 2nd-floor door to the stairs was made of wood. There was 1 fire extinguisher and 1 guiding light on the 2nd floor. (During the fire, the guiding light for the indoor stairs was functioning.) The 2nd-floor door to the outside stairs was made of plywood.

III. Actions Taken after the Fire was Detected (1) First Detected Detected by How and why Action taken ( Owner of Raku Raku ) ( Smoke drifting from the door ) ( Shouted out "Fire!" ) Right before closing time, the bar owner went to the cash register and saw smoke drifting from the door clearance. He told the supervisor to check on the smoke. When the supervisor came closer to the door, a large amount of smoke started to enter the bar, so he alerted the owner by shouting "Fire!" The manager who heard him checked the kitchen to find out if smoke was emerging from there, but it was not. On the way back to the cash register, the power went off. He walked along the wall to the counter to get a flashlight. He pointed to the emergency exit with the flash light and told people, "The emergency exit is right here" while he was running toward to the exit. (2) Emergency Call Emergency Call Yes ( ) Time elapsed since detection ( ) minutes No [X] (a female passerby made a 119 call from a pay phone) The waitress of a restaurant which was 150 m away from the fire building was on her way home. When she was about to turn a corner, she saw an arch-shaped flame in a few buildings down on the north side of Recreation Center S. She wondered a while until she realized that it was fire and made a 119 call from the pay phone near by. While she was on the phone with the fire station operator, she heard a sound similar to the backfire in an automobile engine, so she stated there was " an explosion as well" to the operator. No call came from the fire building. (3) Initial Firefighting Activities Initiated Not Initiated Successful Failed [ X ] Extinguished timing Firefighting difficulties Firefighting method Extinguished timing Firefighting difficulties Firefighting method Other (Reasons or Conditions) The detection of the fire was late and so people barely escaped. The smoke entered the bar all at once when the exit door was opened, and people panicked. (4) Summary of Firefighting Activities (Obstacles or Difficulties in Fire Control) When the firefighters arrived, they had a hard time assessing the situation because no one was able to provide reliable information regarding the evacuees in need of rescue. Since the windows on the 2nd floor were blocked off from inside, it some time for the firefighters to knock them down in order to enter the building.

(5) Evacuation Means of Escape (No. of Persons) Stairs [ X ] (4) Elevators/Escalators ( ) Escape equipment ( ) Directly to ground from windows or openings [ X ] ( 3 ) Rescued ( ) Other ( ) ( ) Obstacles to Evacuation No windows [X] Barred openings [ X ] Locked emergency doors (Exits) Alarm system (Poorly controlled, Malfunctioned, Not installed) Power outage [X] Other [X] The manager with a flashlight came to the exit door to the outside stairs. After he moved the furniture that was blocking the exit, he opened the door (plywood, inward opening) and 3 hostesses escaped from the exit, and he used the flashlight to guide people from inside for a while, but had to evacuate because of smoke. The supervisor and 2 hostesses went to the 3rd-floor landing of the inside stairs and from the window on the stairwell they jumped down to the roof of an adjacent 2-story wooden building to escape. * Those who exited the building were employees who knew the layout of the building, and all of the guests were left behind and died. (6) Causalities Healthy individuals 15 (Drunk persons ) Individuals in need of assistance Infants Elderly Handicapped Patients/ill persons Obstacles to Evacuation No windows [X] Barred openings [ X ] Locked emergency doors (Exits) Alarm system (Poorly controlled, Malfunctioned, Not installed) Power outage [X] Other [X] This fire resulted in 15 fatalities (the owner, 5 hostesses, and 9 guests). 7 people (3 males and 4 females) were found near the exit where the manager was pointing with his flashlight. Presumably they followed his voice and tried to escape from there. The owner who was at the counter had walked away from the exit and was found in the center of the floor. The guests who were found inside the bar were: 1 inside the cloakroom, 3 in the center of the floor, and 1 in the stairway behind the counter. One of the hostesses was found at the corner of the counter. One of the guests came down the burning stairs and died near the 1st-floor exit. IV. Issues and Lessons Learned 1. When the fire spread it burned the cardboard box with which the fire was initially set at the bottom of the stairwell and the fire propagated to the interior walls, where the stairwell was filled with flammable gas (product of the combustion). Also, t air was being consumed completely because the doors to each floor were tightly closed. Under such conditions, when someone opened a door to let fresh air in, the natural reaction would inevitably be explosive combustion. That is what happened in this fire when a passerby opened the door slightly to the 1st floor. 2. The openings (windows) were all closed off by decorative interior materials, which interfered with the evacuation and firefighting operations. 3. The exit to the outside stairs was blocked by furniture and plants, which also interfered with the evacuation. 4. The interior of the stairwell was finished with combustible materials, which facilitated the fire spreading to the upper floors. 5. The 1st floor had a fire wall against the stairwell, but the clearance of the shutter case and the unsealed clearance around the shutter became the propagation path. 6. Building management failed to comply with the fire-prevention manager requirement and inadequately handled fire prevention matters. As a result, the employees failed to guide the guests to evacuate safely. 7. The guests were probably all intoxicated, which lead to their slow reaction in the emergency situation.