ERRATA AND REVISIONS MEASURES FOR FIRE SAFETY IN HIGH BUILDINGS

Similar documents
BUILDING CODE COMMISSION

Secondary Suites Changes between the 2006 ABC and the 2014 ABC Requirements

BUILDING CODE COMMISSION

NEW ACCESSIBILITY CHANGES

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION

2014 OSSC CHAPTER 10 - MEANS OF EGRESS TABLE OF CONTENTS

2018 CSBC / 2018 CSFSC Part III. Chapter #10. Means of Egress. Table of Contents. Based on the 2015 IBC and the 2015 IFC.

Approved Document B Single stairways - Residential uses Part 1

Protecting the Stair Enclosure in Tall Buildings Impacted by Stack Effect

Background: 5 th Edition (2014) Florida Building Code, Building

Section 9.5. Design of Areas, Spaces and Doorways

NFPA (2012). In a high-rise building, stairwell pressurization systems typically utilize multiple fans distributed over the height of the stair, a duc

COUNCIL ORDER No

The New NYC Building Code Chapter 10 Means of Egress. New York City Department of Buildings. Technical Affairs. Fatma M. Amer, P.E.

CITY OF MOUNT PLEASANT ORDINANCE NO. 1017

Etobicoke York Community Council Item [#], as adopted by City of Toronto Council on [date] Draft Zoning By-law Amendment (March 20, 2019)

Authority: Toronto and East York Community Council Item 26.9, as adopted by City of Toronto Council on October 8, 9, 10 and 11, 2013 CITY OF TORONTO

Ontario s 2012 Building Code Barrier-Free Design Amendments Ontario Regulation 332/12 Amended by O. Regs. 368/13 and 191/14

SPECIFIC GUIDANCE FOR A BEDSIT TYPE HOUSE IN MULTIPLE OCCUPATION (HMO)

2012 IBC Mixed Occupancies

THIS CHECKLIST HAS BEEN AMENDED TO INCLUDE ONLY LEVEL ONE CRITERIA AS REQUESTED BY TIR REAL PROPERTY. As such it does not form a complete Checklist.

Presentation By. Chris Poujol. Jeffery Rodriguez. James Rigley

Amendments to Chapter proposed by the Assembly Title 21 Committee

Schedule C Barrier-Free Design

BUILDING GUIDELINE MEASUREMENT. Appraisal Institute of Canada 403 ~ 200 Catherine Street Ottawa, Ontario K2P 2K9

BUILDING CODE COMMISSION

MSC Guidelines for Review of Means of Escape (Subchapter H)

Purpose. Scope. Stairway Identification Signs. Emergency Evacuation and Stairwell Signage Requirements

THE CORPORATION OF THE CITY OF PORT COQUITLAM BYLAW NO. 3848

BUILDING CODE INTERPRETATION

Large Building Air Leakage Testing

PP Course # Instructor Information. Patrick Vandergriff 35 Cottonwood Canyon Road La Luz, NM

(2) Determining Occupant Loads for the Operation of a Building (The Alberta Fire Code)

UNIVERSITY OF HONG KONG LIBRARY. This book was received in accordance with the Books Registration Ordinance Section 4

Howard 0** Basement

THE CITY OF VAUGHAN BY-LAW BY-LAW NUMBER WHEREAS the matters herein set out are in conformity with the Official Plan of the Vaughan Planning

Copyright 2013, Queen s Printer for Ontario

Regulation Outline. Under section 59 of the Community Planning Act, the Lieutenant-Governor in Council makes the following Regulation:

FLOOR AND ROOM NUMBERING GUIDELINES

City of Vancouver Zoning and Development By-law Planning, Urban Design and Sustainability Department

APPLICATION OF SECTION 3.8 OF THE 2012 ONTARIO BUILDING CODE FOR: BARRIER-FREE AUDIT OF SENECA COLLEGE NEWNHAM CAMPUS TORONTO, ONTARIO

ORDINANCE NO THE CITY COUNCIL OF THE CITY OF MANHATTAN BEACH DOES HEREBY ORDAIN AS FOLLOWS:

Authority: North York Community Council Item 34.85, as adopted by City of Toronto Council on August 25, 26, 27 and 28, 2014 CITY OF TORONTO

Single Point of Failure and Inter-relationship between Stair Pressurisation System and Evacuation Strategy for Tall Buildings

The UBBL Applications of Fire Safety Provisions

E1-12: Final Decision AS

JCLI Scottish Employer Novation Agreement

West 1st Avenue By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

City of Vancouver Zoning and Development By-law Planning, Urban Design and Sustainability Department

CITY OF CORNWALL BY-LAW 111 A BY-LAW TO ENTER INTO A LEASE WITH SOCIAL & HOUSING SERVICES AT 340 PITT STREET, CORNWALL, ONTARIO

Sample Questions for Paper 1 Statutory Controls in Building Works

Authority: Etobicoke York Community Council Item 25.2, as adopted by City of Toronto Council on April 6, 2009 Enacted by Council: April 30, 2009

3. Miscellaneous Instructions and Definitions.

DATE: 4/24/12 PRESENT AT SITE: Aaron Lobas, Daniel Imlay - URS JOB NAME: Cuyahoga County Huntington Park Garage JOB NUMBER:

320 Bay Street TORONTO ONTARIO. Tracy Macdonald Vice President,

SCHEDULE A TO BY-LAW NUMBER (Amended by By-law ) CLASSES OF PERMITS AND PERMIT FEES

Misawa Building (Hostess Bar "Raku Raku")

Emergency Evacuation and Stairwell Signage

THE CORPORATION OF THE TOWN OF EAST GWILLIMBURY BY-LAW 2016-

Vestibule Requirement Intent

THE CITY OF NEW YORK DEPARTMENT OF FINANCE

Scarborough Community Council Item SC32.3, as adopted by City of Toronto Council on July 23, 24, 25, 26, 27 and 30, 2018 CITY OF TORONTO

BUILDING CODE COMMISSION

Suite Permission. Suites complying with shall be permitted to be used to meet the corridor access requirements of


LAWS OF MALAYSIA. Act A1290 STRATA TITLES (AMENDMENT) ACT 2007

2012 IBC Means of Egress

169 CANAL STREET. 169 Canal Street VISION PROPERTIES 401 E. ELM STREET SUITE 150 CONSHOHOCKEN, PA Providence RI /20/2017

A By-law to amend Zoning and Development By-law No regarding Laneway Houses

Ontario Municipal Board Decision issued July 28, 2014 and Orders issued December 4 and 17, 2015 in Board File No. PL CITY OF TORONTO

DRS RWANDA STANDARD. Code of practice for fire safety. of building. Part 5: Exit requirements and personal hazard.

Regional District of Nanaimo Secondary Suite Program

The New NYC Building Code Chapter 11 Accessibility. New York City Department of Buildings. Technical Affairs. Keith Wen, R.A. Copyright Materials

1133 West Georgia Street By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

Discuss the history of fires that resulted in much of the development of codes related to means of egress. Review mean of egress terminology

CD-1 (264) 101 Terminal Avenue By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

GSA FORM 1364 PROPOSAL TO LEASE SPACE INSTRUCTIONS

Vauxhall Sky Gardens Wandsworth Road London SW8

Item No BENJAMIN WIER HOUSE ADDITION AUGUST 22 ND 2014 Design Rational & LUB Summary

BUILDING CODE COMMISSION

BY-LAW No EXPLANATORY NOTE. Purpose and Effect of the By-law

1003 Pacific Street By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

GENERAL ZONING CODE DESIGN CRITERIA FOR MULTIPLE- DWELLING DEVELOPMENT

CITY OF TORONTO. BY-LAW No

CITY OF TORONTO. BY-LAW No

The Desert Housing Report. Coachella Valley Median Detached Home Price December December 2018

Section 1. Appendix A, "Zoning" of the Code of the City of Charlotte is hereby amended as follows:

The City of Los Altos Building Square Footage Calculations Used for Determining Parking Requirements November 4, 2015 ATTACHMENT F

Authority: Ontario Municipal Board Decisions/Orders issued June 26, 2014, August 24, 2015 and July 13, 2016 in Board File PL CITY OF TORONTO

êéëé~êåü=üáöüäáöüí Code Requirements and Costs of Incorporating Accessory Apartments in Houses

COMO LAKE AVE. LAND ASSEMBLY

BUILDING CODE COMMISSION

AMENDMENTS TO PROPRIETARY LEASE

CITY OF TORONTO. BY-LAW No

DISTRICT OF NORTH SAANICH BYLAW NO. 1306

General Information RETAIL AND RESTAURANT

NEPAL NATIONAL BUILDING CODE NBC 206: 2015

MARKETING REPORT ON MULTIFAMILY BUILDING

FIRST AMENDMENT TO THE CONSOLIDATING MASTER DEED MAPLE FOREST CONDOMINIUMS

Transcription:

National Research Council Canada Conseil national de recherches Canada Associate Committee on the NATIONAL BUILDING CODE of Canada Comite associe du CODE NATIONAL DU BATIMENT du Canada Ottawa ERRATA AND REVISIONS TO THE MEASURES FOR FIRE SAFETY IN HIGH BUILDINGS 1973 OTTAWA MARCH 1975

PREFACE The errata and revisions contained in this pamphlet are mainly of an editorial nature and are intended to clarify certain portions of the original document, "Measures for Fire Safety in High Buildings 1973", which were apparently subject to misinterpretation. The original document, together with the changes included in this pamphlet constitute the material to be used in association with Subsection 3.2.6. of the National Building Code 1975, which deals with fire safety in high buildings. A new edition containing these changes will be issued with the 1977 National Building Code. Readers are invited to send comments on the updated document and on Subsection 3.2.6. to the Secretary, Associate Committee on the National Building Code, National Research Council of Canada, Ottawa, Ontario KLA OR6, for consideration during the Code review process.

ERRATA AND REVISIONS TO THE MEASURES FOR FIRE SAFETY IN HIGH BUILDINGS 1973 The Associate Committee on the National Building Code recommends that the following changes be inserted in all copies of the 1973 edition of "Measures for Fire Safety in High Buildings". 1 5 6 7 8 9 9 10 Table of Contents Second Para. Measure A, Item 2 Measure B, Item 2 Measure C, Item 2 Item 2 Item 3 Measure E, Item 2 Opposite Section 2 (f) Change "Measures I and J - Building Core Pressurized" to read "Measures I and J - Partially Pressurized Buildings" In the third line, add a comma after "smokeshaft". "2. Elevator shaft terminates not lower than the first storey (2A(5»." "2. Elevator shaft terminates not lower than the first storey (2B(4»." "2. Elevator shaft terminates not lower than the first storey (2C(4»." "2. Elevator shaft terminates not lower than the first storey (2D(13»." In the second line after "fire emergency" add the words "if the vestibule protection is by pressurization u Delete first three lines and substitute: "2. Elevator shaft terminates not lower than the first storey (2E(11»."

- 2 - Page 14 15 18 19 20 22-23 23 23 Title of Measure I Title of Measure J Measure L, Item 4 Measure L, Item 3 Measure M, Item 3 Measure A, Sentenc.e (3) Measure A, Sentence (5) Change title to read "MEASURE I. PARTIALLY PRESSURIZED BUILDING". Change title to read!!measure J. PARTIALLY PRESSURIZED BUILDING". Delete the first 3 lines and substitute: "4. Firefighters' elevator shaft terminates not lower than the first floor below the lowest exit storey or has elevator vestibules in every storey below the lowest exit storey (2L(12».ft Delete the first 4 lines and substitute: "3. Firefighters' elevator shaft terminates not lower than the first floor below the lowest exit storey or has elevator vestibules in every storey below the lowest exit storey (2L(12»." Delete the first 3 lines and substitute: "3. Elevator shaft terminates not lower than the first storey (2~1(4». n Change Clause (a) to read "( a) has a vent or door to the outdoors at or near the top of the stairshaft that has an openable area of at least 1.25 sq ft for each storey served by the stairway, less 0.1 sq ft for each weathers tripped door and 0.2 sq ft for each non-weathers tripped door opening into the stairshaft." In the last line of Clause (b), after "fire separation", add "having a fire-resistance rating not less than that required for the shaft enclosure". In the third line of Clause (c) delete the words "at least". "(5) Any elevator shaft that passes through the floor above the lowest exit storey does not penetrate the floor of the storey immediately below the lowest exit storey, except where there is a vestibule between the shaft and each below-grade floor area as is described in of Measure D (p.36)."

- 3 - Page 23 25 28 29 30 30-31 37 Measure A, Sentence (6) Section 2(b) Measure B, Measure B, Sentence (4) Measure C, Measure C, Sentence (4) In the last line change "2F( 10)" to read "2 (D) (10) ". In the sixth paragraph, add to the end of the paragraph "in buildings exceeding 120 ft in height". "(3) A stairway serving storeys below the lowest exit level is protected as described in of Measure A (p.22)." "(4) Any elevator shaft that passes through the floor above the lowest exit storey does not penetrate the floor of the storey immediately below the lowest exit storey, except where there is a vestibule between the elevator door or doors and each belowgrade floor area as described in of Measure D (p.36)." "(3) A stairway serving storeys below the lowest exit level is protected as described in of Measure A (p.22)." "(4) Any elevator shaft that contains a firefighters' elevator and passes through the floor above the lowest exit storey does not penetrate the floor of the storey immediately below the lowest exit storey, except where there is a vestibule between the elevator door or doors and each below-grade floor area as described in of Measure D (p.36)." In the last line of Clause (b), delete "and". Delete Clause (c) and substitute the following two new Clauses: "(c) a fire separation is provided between a stair or elevator enclosure and the vestibule that has a fireresistance rating not less than that required for an exit in NBC Article 3.4.5.1., and (d) a door in the fire separation described in (a), (b) or (c), except for an elevator door, is provided with a self-closing device as required by NBC Subsection 3.1.7., and opens in the direction of travel from the floor area to the exit stairway."

- 4-37-38 38 39 39 40-41 41 47 47 48 Sentence (8) Sentence (13) Sentence (16) Sentence (18) Measure E, Sentence (7) Measure E, Sentence (11) Sentence (2) Sentence (6) "(8) A stairway serving storeys below the lowest exit level is protected as described in of Measure A (p.22)." In the first line, change "(16)" to read "(14)". In the fourth line, change "Sentence (5)" to "(IS)". In the last line of Clause (b) change "(6) and (7)" to read "(15) and (16)". "(7) A stairway serving storeys below the lowest exit level is protected as described in of Measure A (p.22)." "(11) Any elevator shaft that contains a firefighters' elevator and passes through the floor above the lowest exit storey does not penetrate the floor of the storey immediately below the lowest exit storey, except where there is a vestibule between the elevator door or doors and each below-grade floor area as described in of Measure D (p.36)." In the first line of Clause (a), change "bottom" to read "lowest exit level". "(3) A stairway serving storeys below the lowest exit level is protected as described in of Measure A (p.22).11 Change first 5 lines to read "Any elevator shaft that contains a firefighters' elevator and passes through the floor above the lowest exit storey does not penetrate the floor of the storey immediately below the lowest exit storey, except where each floor area below the lowest exit storey is provided with a vent to the outdoors that" Change Clause numbers n(i), (ii) and (iii)" to read "(a), (b) and (c)" respectively.

- 5-48 49 49 49 50 50 51 51 Sentence (10) Sentence (11) Sentence (12) Sentence (14) Measure G, Sentence (2) Measure G, Measure G, Sentence (6) Measure G, Sentence (7) Delete Clause (a) and substitute: U(a) if it is in a vertical service space other than an elevator shaft described in (b) in a building in which other shafts are not mechanically pressurized, has an openable area that is not less than that obtained from Graph 1 in Appendix A, or if it is in a building in which other shafts are mechanically pressurized, has an openable area that is not less than that obtained from Graph 2 in Appendix A," Change the fourth line of Clause (c) to read "or near the foot of the shaft at or near the exit level where the top of the shaft is". Change last 2 lines to read "rooms and bathrooms in dwelling units, air-moving fans in an air handling system that serves more than 2 storeys are capable of being stopped as provided in (14)". In fourth line change U(12)" to read "(11)". In the second line of Clause (a) change "(12) and (13)" to read "( 11), (12) and (13)". In the first line of Clause (a), change Itbottom" to read "lowest exit level lt "(3) A stairway serving storeys below the lowest exit level is protected as described in of Measure A (p.22)." Change first 4 lines to read "(6) Any elevator shaft that contains a firefighters' elevator and passes through the floor above the lowest exit storey does not penetrate the floor of the storey immediately below the lowest exit storey, except where each floor area below the lowest exit storey is provided with a vent to the outdoors that," Change the last 2 lines to read 'washrooms and bathrooms in dwelling units, air moving fans in an air handling system that serves more than 2 storeys are capable of being stopped as provided in (9)".

- 6-55 55 57 59 59 59 61 62 62 62 67 71 Measure H, Sentence (1) Measure H Section 2(f) Measure I Measure I, Sentence (2) Measure I, Measure I Sentence (10) Measure J Measure J Sentence (2) Measure J Measure K, Sentence (11) Measure L In last line change "Sentences (2) to (8)" to read "Sentences (2) to (9)". After Sentence (2) add new as follows and renumber remaining sentences and the references therein accordingly: "(3) Exit stairs shall discharge to the outdoors through a vestibule described in of Measure D and provided with a mechanical air supply of not less than 200 cfm per weatherstripped door and 400 cfm per non-weatherstripped door in the vestibule~ except that the vestibule may be a corridor J lobby or other space." Change the title to read "Partially Pressurized Building". In the title, delete "(Compartmented Floor Area)". In the third and fourth lines change "stairs, elevator shafts and corridors" to read "all required exit stairs, all shafts containing firefighters' elevators and public corridors". In the third line, change "corridors" to read "public corridors". In the last line, change "(9)" to "(10)". Delete Clause (d) and substitute: "(d) opening closures in vents referred to in (4), individually or in groups limited to one floor at a time, and" In the title delete "(Compartmented Floor Area)". In the third and fourth lines change "stairs, elevator shafts and corridors" to read "all required exit stairs, all shafts containing firefighters' elevators and public corridors". In the fourth line, change "corridors" to read "public corridors". In the fourth line of Clause (a) delete "and will open as provided in (17)". After Sentence (2), add new and renumber existing Sentences (3) to (20) and the references therein accordingly.

- 7-71 72 72 75 76 76 79 79 81 Measure L (cont'd) Measure L, Sentence (12) Measure L, Sentence (14) Section 2 (i) Measure M, Measure M, Sentence (4) Measure N, Sentence (2) Measure N, Table 2 "(3) On any floor area, any area of refuge that has a door to an exit stair may also have a door to a firefighters' elevator but two exit stairs may not open on to the same area of refuge provided no other vertical shaft is common to the two independent systems described in Sentence (2)." "(13) Any elevator shaft that contains a firefighters' elevator or opens into an area of refuge and passes through the floor above the lowest exit storey does not penetrate the floor of the storey immediately below the lowest exit storey, except where there is a vestibule between the elevator door or doors and each below grade floor area as described in of Measure D (p.36)." "(15) A stairway serving storeys below the lowest exit level is protected as described in of Measure A (p.22)." In the last line of the second paragraph delete "over the voice communication system". "(3) A stairway serving storeys below the lowest exit level is protected as described in of Measure A (p.22)." "(4) Any elevator shaft that passes through the floor above the lowest exit storey does not penetrate the floor of the storey immediately below the lowest exit storey, except where there is a vestibule between the elevator door or doors and each below-grade floor area as described in of Measure D (p.36)." In the second line change "Article 3.2.1.1." to read "Subsection 3.1.8.". In the fourth line of Clause (a) add after the word "vestibule" "or if the perimeter of doors exceeds 20 ft, the value of "d" is increased in direct proportion to the increase in the perimeter'. In the third column, fifth line from the bottom change "99.4" to read "9.9".

- 8-82 90 92 94 9S 96 110 Table 4 Notes to Graph 3 Notes to Graph 4 Notes to Graph S Graph 6 Notes to Graph 6 Appendix B Insert the notation "(2)" after heading of first column. Change "Note (1) to Table 4" to read "Notes to Table 4". Remove brackets from existing Note and insert "(1)" before Note. Add new Note (2) as follows: "(2) These leakage data contemplate clearances applicable to approved fire dampers which have been tested in accordance with ULC-Sl12-l973, 'Fire Dampers'." In line 7 of Note (1) change "c" in the formula explanation to read "e". At the end of Note (1) add "The quality "F Jd + lsoe + 200s" represents the total leakage from the vestlbule. n At the end of Note (3) add "The expression (0.2Sd4+ 0.0014a4) represents the total leakage area in the walls of the shaft." At the end of Note (1) add "The expression (0.2Sd + 0.0014a ) represents the total S S leakage area in the walls of the shaft." Extend lower limits of all curves as a horizontal line terminating at Factor F 6 = 0.500, and show this horizontal line as a darker line. In the first line of Note (S) change "If Measure I is used" to read "If Measure I or J is used". In the fourth line from the bottom change explanation "a" to read "rate of diluent air flow in number of air changes per minute".