LeBreton Flats Redevelopment Development Summary Chart (First Subdivision)

Similar documents
6.0 DEVELOPMENT OPPORTUNITIES

66 Isabella Street Rezoning Application - Preliminary Report

900 ALBERT STREET PLANNING RATIONALE ADDENDUM NO. 2

PREPARED FOR: ADI DEVELOPMENT GROUP INC.

Plan Dutch Village Road

111 Wenderly Drive Official Plan and Zoning By-law Amendment Applications - Preliminary Report

LAND USE AND BUILT FORM

3.1 Existing Built Form

Director, Community Planning, North York District NNY 10 OZ and NNY 10 RH

Sheppard Ave East and 6, 8 and 10 Greenbriar Road - Official Plan Amendment and Zoning Amendment Applications - Preliminary Report

3390, 3392, 3394, 3396 and 3398 Bayview Avenue - Official Plan Amendment, Zoning By-law Amendment Application - Preliminary Report

Director, Community Planning, Toronto and East York District

LITTLE MOUNTAIN ADJACENT AREA REZONING POLICY

STAFF REPORT. March 14, Toronto and East York Community Council. Director, Community Planning, South District

900 BURRARD STREET CD-1 GUIDELINES (BY-LAW NO. 6421) (CD-1 NO. 229) CONTENTS. 1 Application and Intent... 1

1202 & 1204 Avenue Road Zoning By-law Amendment Application - Preliminary Report

250 Lawrence Avenue West - Official Plan and Zoning By-law Amendment Applications Preliminary Report

BYLAW NO. 15/026 A BYLAW OF THE REGIONAL MUNICIPALITY OF WOOD BUFFALO TO AMEND THE LAND USE BYLAW NO. 99/059

Director, Community Planning, North York District NNY 23 OZ and NNY 23 RH

Policy and Standards for Public Local Residential Streets And Private Streets

5.1 Site Planning & Building Form

45 & 77 Dunfield Avenue - Zoning Amendment Application - Preliminary Report

Appendix C Built Form Guidelines

Urban Design Brief 6233, 6237, 6241 and 6245 Main Street, Stouffville Pace Savings and Credit Union June 15, 2012

8.5.1 R1, Single Detached Residential District

Peter Street and 357 Richmond Street West - Zoning Amendment Application - Preliminary Report

2 Holiday Drive - Zoning Application - Preliminary Report

Galloway Road and 4097 Lawrence Avenue East - Zoning Amendment Application - Preliminary Report

Director, Community Planning, Etobicoke York District

Preliminary Report Zoning By-law Amendment and Site Plan Control Applications Yonge Street

Planning Justification Report

Montreal Road District Secondary Plan [Amendment #127, October 9, 2013]

12, 14, 16 and 18 Marquette Avenue and 7 Carhartt Street Zoning By-law Amendment Application - Preliminary Report

Appendix1,Page1. Urban Design Guidelines. Back to Back and Stacked Townhouses. DRAFT September 2017

355 King St W and 119 Blue Jays Way - OPA & Rezoning Applications - Preliminary Report

740 and 750 York Mills Road and 17 Farmstead Road Zoning By-law Amendment Application Preliminary Report

Director, Community Planning, North York District NNY 23 OZ Related File Nos NNY 23 OZ and NNY 23 SA

Urban Design Brief (Richmond) Corp. 1631, 1635, 1639, 1643 and 1649 Richmond Street City of London

Jasper 115 Street DC2 Urban Design Brief

774 BRONSON AVENUE MINOR ZONING BY-LAW AMENDMENT + SITE PLAN CONTROL PLANNING RATIONALE + DESIGN BRIEF

507, 509 and 511 Kingston Road - Official Plan and Zoning By-law Amendment Applications - Preliminary Report

1417, , 1427 & 1429 Yonge Street - Official Plan Amendment and Zoning Amendment Applications - Preliminary Report

50+54 BELL STREET NORTH

Northwest Corner of Dufferin Street and McAdam Avenue (0 Dufferin Street) Rezoning Application Final Report

6040 Bathurst Street and 5 Fisherville Road Zoning Bylaw Amendment Application Preliminary Report

Cover Letter with Narrative Statement

Ontario Municipal Board Order issued on February 25, 2005 in Board File Nos. PL and PL CITY OF TORONTO. BY-LAW No.

40-58 Widmer Street - Zoning Amendment Application - Preliminary Report

1970 Victoria Park Avenue and 9 Clintwood Gate Zoning By-law Amendment Application Preliminary Report

Toronto and East York Community Council. Director, Community Planning, Toronto and East York District

25 St. Dennis Drive - Zoning By-law Amendment Application - Preliminary Report

3 and 5 Southvale Dr - Official Plan Amendment and Zoning Amendment Applications - Preliminary Report

Church Street and Gloucester Street - Rezoning Application - Preliminary Report

Zoning By-law Amendment & Site Plan Control Application

Director, Community Planning, South District

SUBJECT: Official Plan and Zoning By-law Amendment Applications for 4853 Thomas Alton Boulevard

13 Major Nodes Introduction General

Article 2. Rules of Interpretation

3445 Sheppard Avenue East - Zoning Amendment Application - Preliminary Report

Toronto and East York Community Council. Director, Community Planning, Toronto and East York District

2450 Victoria Park Avenue - Zoning By-law Amendment Application - Preliminary Report

CITY OF TORONTO. BY-LAW No

Director, Community Planning, Etobicoke York District WET 13 OZ and WET 13 RH

CHAPTER 154: SIGNS. Section

Yonge Street and 3 Gerrard Street East - Zoning Amendment Application - Preliminary Report

27-37 Yorkville Avenue and 26-32, 50 Cumberland Street Official Plan and Zoning Amendment - Final Report

Church Street and 117 Dundas Street East - Zoning Amendment Application - Preliminary Report

PLANNING RATIONALE REPORT CODEAU BUILDING LTD RIDEAU STREET OTTAWA DECEMBER 2013

200 St. Clair Ave W - Official Plan Amendment and Zoning Amendment Applications - Preliminary Report

1061 The Queensway - Official Plan and Zoning By-law Amendment Applications - Preliminary Report

6208 Jeanne D Arc Boulevard North. Planning Rationale. Site Plan Control

AMENDMENT NUMBER XX TO THE OFFICIAL PLAN OF THE TOWN OF MILTON. THE PREAMBLE, does not constitute part of this Amendment

40 Moccasin Trail and 50 Green Belt Drive - OMB

770 BROOKFIELD ROAD Site Plan Control Atlantis Investments November 2017

PLANNED DEVELOPMENT DISTRICT STANDARDS. Cadence Site

STAFF REPORT. September 25, City Council. Chief Planner and Executive Director, City Planning Division

THE CORPORATION OF THE DISTRICT OF PEACHLAND BYLAW NUMBER 2065, A Bylaw to Amend Zoning Bylaw Number 1375, 1996

Kassner Goodspeed Architects Ltd.

Director, Community Planning, North York District

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: April 18, 2019

377 Spadina Rd and 17 Montclair Ave - Zoning Amendment Application - Preliminary Report

PROVIDENCE (BOLLARD BULRUSH SOUTH) LOCAL DEVELOPMENT PLAN. 2263Rep146E

Authority: Toronto and East York Community Council Item 26.9, as adopted by City of Toronto Council on October 8, 9, 10 and 11, 2013 CITY OF TORONTO

17 Island Road - Zoning Amendment Application Final Report

Bloor Street West, 6-14 Oakmount Road and 35 and 37 Pacific Avenue Official Plan Amendment and Rezoning Applications - Preliminary Report

ARTICLE 5.0 SCHEDULE OF REGULATIONS

307 Sherbourne Street - Zoning Amendment Application - Preliminary Report

4650 Eglinton Avenue West - Zoning By-law Amendment Application - Preliminary Report

20 Edward Street Zoning Amendment Application - Preliminary Report

Authority: Etobicoke York Community Council Item 25.2, as adopted by City of Toronto Council on April 6, 2009 Enacted by Council: April 30, 2009

5 to 25 Wellesley Street West and 14 to 26 Breadalbane Street - Zoning Amendment Application - Preliminary Report

470, 490 and 530 Wilson Avenue - Zoning Amendment and Rental Housing Demolition and Conversion Applications - Preliminary Report

Goal 1 - Retain and enhance Cherry Creek North s unique physical character.

3636 Bathurst Street Zoning By-law Amendment Application - Preliminary Report

MINTO COMMUNITIES INC. AVALON WEST STAGE 4 PLANNING RATIONALE. July Prepared for:

ADELAIDE APARTMENTS TOWER EXTENSION

3005 Bloor Street West and 14 Humbervale Boulevard - Official Plan and Zoning Amendment Applications - Preliminary Report

Proposed London Plan Amendment 1631, 1635, 1639, 1643, and 1649 Richmond Street London, ON

SITE PLAN REVIEW COMMITTEE MEETING AGENDA Clarendon Boulevard Conference Rooms C & D Arlington, VA 22201

39 Thora Avenue Zoning Amendment Application Preliminary Report

Transcription:

Redevelopment Development Summary Chart (First Subdivision) Development Analysis Chart NOTE: THE FOLLOWING TABLE REPRESENTS THE RESULTS OF THE NCC'S DEMONSTRATION OF DEVELOPMENT CAPACITY. WHILE ACTUAL DEVELOPMENT FIGURES MAY VARY, DEVELOPMENT MUST BE IN GENERAL CONFORMITY WITH THE DENSITIES SHOWN IN THE NCC'S DEMONSTRATION PLANS. Development yield and number of underground parking levels required for buildings with residential and commercial development: The development area is part of the Central Area referred to in the City of Ottawa parking regulations and loading. For the purposes of this analysis, residential buildings are assumed to be apartment buildings 20m deep, containing a mix of units, and townhouses 11m deep. Developable site area is the area contained within a specific block, or part thereof, and delineated by the required setbacks. All residential buildings are within 400m of the proposed transit station to be built at Booth St. and the Transitway. According to By-law 6-2000, combined resident & visitor parking for buildings within 400m of a transit station need not exceed: one(1) per dwelling unit. It is stipulated that every dwelling unit requires one(1) parking space. Density and unit allocation to individual development blocks are determined by infrastructure servicing capacity. Block 12 will require forcemain sanitary service due to its location south of the closed aqueduct. The Lett Street sanitary sewer must have a 20 litres/second reserve capacity for future off-site sanitary discharge. KEY PLAN Block Zone Proposed use Site area Max building height Max No. of floors Building ground fl. area Retail GFA Residential GFA Total Building GFA Residential units (total) Parking spaces per level Required Parking spaces Required parking levels FSI 1 R6K Apt building / stacked townhouses m 2 m No. m 2 m 2 m 2 m 2 No. No. No. No. 7 962 40 12 4 536 0 35 104 35 104 375 234 375 1.6 4.7 2 R6K Stacked townhouses 5 675 20 6 2 660 0 12 448 12 448 129 142 129 0.9 2.3 3 R6K 4 CN9 12 R7D Apt building / stacked townhouses Apt / ground fl. retail / stacked townhouses Apt building/retail on the ground and 2 nd floor 5 234 20 6 2 527 0 11 714 11 714 120 153 120 0.8 2.3 5 988 40 6 3 901 2 501 18 159 20 660 153 205 171 0.8 2.9 1 112 40.5 6 904 1808 3 072 4 480 10 30 23 0.8 4.4 Totals 25 971 4309 80 497 84 806 787 818 NOTE: THE FOLLOWING BLOCK SPECIFIC GUIDELINES FOLLOW THE DEVELOPMENT PREMISE SET OUT IN THE MASTER PLAN DEVELOPED FOR THE OVERALL SITE THAT CREATES A STREET-WALL ALONG WELLINGTON BOULEVARD, BOOTH AND FLEET STREET THROUGH THE USE OF 6-STOREY BUILDINGS LOCATED ADJACENT TO PROPERTY LINES AND THE USE OF 12-STORY POINT TOWERS. ALL BLOCKS FEATURED STREET-RELATED DEVELOPMENT AND THE USE OF INTERNALIZED COURTYARDS CONSTRUCTED OVER STRUCTURED PARKING. MANDATORY BUILD-TO LINES ARE ILLUSTRATED ON THE FOLLOWING PAGES AS SOLID RED LINES. WHERE NOT EXPRESSED AS A MANDATORY CONDITION, THE NCC WILL CONSIDER THE PROPONENT S DESIGN PROPOSAL ON ITS MERITS AND ITS CONFORMITY TO THESE GUIDELINES. THE GUIDELINES SHALL GOVERN THE PURCHASER S DESIGN REPOSNSE AND THE NCC S REVIEW OF THE PURCHASERS DESIGN PROPOSAL. 29

Block 1 Description Block 1 is a large development parcel situated at the most north easterly portion of the development. It is one of the most prominant and desirable sites for residential use because of its location and extensive frontage onto the aqueduct and tailrace, and proximity to public open space planned for. The location and orientation of this block is particularly important in the dynamic entry and exit view sequences as one enters or leaves the Confederation Boulevard. For this reason, the architectural design of the buildings on this parcel must be carefully considered and be of high quality. The block has direct frontage onto Wellington Street and has an important role in establishing and reinforcing this as a capital edge in the form of point towers up to 12 storeys (40.0m.) maximum in height and a maximum floor plate of 700 square metres over a six storey high (20.0m.) maximum base building condition. The block also has direct street frontage onto Lett Street, a local road within the development. The south frontage onto the Fleet Street right-of-way occurs where Fleet becomes a pedestrian mews fronted by grade-oriented residential units. The eastern portion of the block boundary fronts directly onto the aqueduct and tailrace open space system, providing a highly desirable residential frontage. Residential uses are required at the ground floor level and the north, south, east, and west setback dimensions are compulsory "build-to" lines. Zoning The zoning designation applied to this parcel of land is R6K, which permits apartment buildings, stacked townhouses and a range of other associated residential uses. BLOCK 1, PROPERTY BOUNDARIES, SCALE 1:750 30

Block 1 Block Organization The organization of Block 1 is based upon a perimeter configuration of 6-storey residential buildings fronting onto Wellington Street, Lett Street, the Fleet Street easement. Point tower forms with a maximum floorplate of 700 sqare metres, setback from the Wellington Street property line 13.5 m set back a minimum of 7.0 m from both the Fleet Street easement and Lett Street property line. The built form fronting Wellington Boulevard, Lett and Fleet streets shall have a height of 6 stories or 20m. Setbacks and Build-To Lines Measured from Property Line: Up to 20 Metre Height: Wellington Street Lett Street Fleet Street easement Eastern Frontage Build-To Line determined by no-build-zone (schedule 226 of City of Ottawa By-Law 98) 3.0m Build-To Line 6.1m Build-To Line 3.0m Min. Setback Above 20 Metre Height: Northern Property Line Fleet Street Easement Lett Street Eastern Frontage 13.5m Setback determined by view protection corridor (schedule 225 of City of Ottawa By-Law 98) 7.0m Setback 7.0m Setback 7.0m Min. Setback Minimum building height: 20m or 6 storeys on Wellington, Lett and Fleet Streets 14m or 4 storeys on the flanking streets Maximum Overall Building Height: Maximum Point Tower Floor Plate: 40m 700 square metres DEMONSTRATION PLAN FOR BLOCK 1, BUILT FORM, SCALE 1:750 31

Block 1 The building envelope is illustrated in these sections. It is mandatory that the built form be articulated by its architecture at the 4-story or 14m height above grade through a setback of at least 1.5m. and/or a cornice or some other acceptable architectural feature, and that the maximum height limits and setbacks be respected, both in plan and in section. SECTION OF DEMONSTRATION PLAN FOR BLOCK 1, SECTION S2-S2, SCALE 1:600 SECTION OF DEMONSTRATION PLAN FOR BLOCK 1, SECTION S1-S1, SCALE 1:600 32

Block 1 Edge Conditions Residential Ground floor dwelling units are to be addressed, have direct access from, and have windows facing into the street. Ground floor dwelling units and their front porch/yard areas are to be elevated a minimum of 0.6m. and a maximum of 1.2m. above the adjacent sidewalk grade. Parking and Servicing All parking is to be located in below-grade structured parking. Parking and service access is to be accessed from Lett Street and must be integrated into the design of the built form and landscape. No parking or servicing access will be permitted from Wellington Street. Parking ramps are to be perpendicular, not parallel, to the street or the Fleet Street easement. CROSS-SECTION OF FLEET ST. EASEMENT, LOOKING EAST (DEMONSTRATION PLAN) RESIDENTIAL BUILDING EDGE (DEMONSTRATION PLAN) 33

Block 2 Description Block 2 is located immediately south of the Fleet Street right-of-way and east of Lett Street. Like Block 1, Block 2 is one of the most desirable sites for residential development because of its location and frontage onto the aqueduct and its proximity to open space planned for. This block functions as a "fabric" block within the urban structure, and does not define a formal Capital edge like Wellington Street. The block is, however, important in defining the edge condition and interface with the open space on its eastern and southern boundaries. The development site has street frontage on the eastern side of Lett Street and southern side of the Fleet Street right-ofway. A residential, 20.0m maximum building height applies across the block. Setback dimensions along the Fleet Street, Lett Street, and south property lines are compulsory "build-to" lines. Zoning The zoning designation applied to this parcel of land is R6K, which permits stacked townhouses and a limited range of other associated residential uses. BLOCK 2, PROPERTY BOUNDARIES, SCALE 1:750 34

Block 2 Block Organization The organization of Block 2 shall respond to the build-to lines established on the Lett and Fleet streets edges of the block. Development facing the aqueduct must respond to the character of the landscaped open space adjacent to the aqueduct. The built form fronting Fleet Street shall be 6 stories or maximum 20m in height. Setbacks and Build-To Lines Measured from Property Line: Up to 20 Metre Height: Fleet Street Easement Lett Street Southern & Eastern Property Line 2.6m Build-To Line 3.0m Build-To Line 3.0m Build-To Line Minimum Building Height: 14m and 4 storeys Maximum Overall Building Height: 20m DEMONSTRATION PLAN FOR BLOCK 2, SCALE 1:750 35

Block 2 The building envelope is illustrated in these sections. It is mandatory that the built form be articulated by its architecture within the maximum height limits and setbacks, both in plan and in section. The 4th floor or 14m. height must be acknowledge by a setback of at least 1.5m. and/or by an acceptable architectural device such as a cornice. SECTION OF DEMONSTRATION PLAN FOR BLOCK 2, SECTION R2-R2, SCALE 1:500 SECTION OF DEMONSTRATION PLAN FOR BLOCK 2, SECTION R1-R1, SCALE 1:500 36

Block 2 Edge Conditions Residential Ground floor dwelling units to be addressed, have direct access from, and windows facing into the street. Ground floor dwelling units and their front porch/yard areas are to be elevated a minimum of 0.6m and a maximum of 1.2m. above the adjacent sidewalk grade. Parking and Servicing All parking is to be located in below-grade structured parking. Parking and service access is to be accessed from Lett Street and must be integrated into the design of the built form and landscape. CROSS-SECTION OF FLEET ST. EASEMENT, LOOKING EAST (DEMONSTRATION PLAN) RESIDENTIAL BUILDING EDGE ON LETT STREET (DEMONSTRATION PLAN) 37

Block 3 Block Description Block 3 is located directly north of the aqueduct and south of Fleet Street. It has direct frontage onto four streets; Fleet Street to the north, Lett Street to the east, Lloyd Street to the west and the connection between Lett and Lloyd Streets to the south. This block is also a "fabric" block, much like Block 2, and because of its expansive street frontage at the design response must reflect an urbane, street-oriented residential development. Built form for this block will consist of a series of 20.0m high maximum residential buildings. Setback dimensions from the north, south, east and west property lines are compulsory "build-to" lines. Zoning The zoning designation applied to this parcel of land is R6K, which permits apartments, stacked townhouses and a limited range of other associated residential uses. BLOCK 3, PROPERTY BOUNDARIES, SCALE 1:750 38

Block 3 Block Organization The mandatory build-to lines will result in an organization of Block 3 that largely expresses a perimeter configuration of residential buildings fronting onto Fleet Street, Lett Street, Lloyd Street, and the southern property line, which may form an internal courtyard. The built form fronting onto Fleet Street shall be 6-storeys. No taller building elements, such as tower forms, are permitted on this development block. Setbacks and Build-To Lines Measured from Property Line: Up to 20 Metre Height: Fleet Street Lett Street Lloyd Street Southern Frontage 3.0m Build-To Line 3.0m Build-To Line 3.0m Build-To Line 3.0m Build-To-Line Minimum Building Height: 20m. and 6 storeys for Fleet street 14m and 4 storeys on Lloyd and Leet streets Maximum Overall Building Height: 20m DEMONSTRATION PLAN FOR BLOCK 3, SCALE 1:750 39

Block 3 The building envelope is illustrated in these sections. It is mandatory that the built form be articulated by its architecture within the maximum height limits and setbacks, both in plan and in section. The 4th floor or 14m. height must be acknowledge by a setback of at least 1.5m. and/or by an acceptable architectural device such as a cornice. SECTION OF DEMONSTRATION PLAN FOR BLOCK 3, SECTION Q2-Q2, SCALE 1:500 SECTION OF DEMONSTRATION PLAN FOR BLOCK 3, SECTION Q1-Q1, SCALE 1:500 40

Block 3 Edge Conditions Residential Ground floor dwelling units to be addressed, have direct access from, and windows facing into the street. Ground floor dwelling units and their front porch/yard areas to be elevated a minimum of 0.6 m and a maximum of 1.2m. above the adjacent sidewalk grade. Parking and Servicing All parking is to be located in below-grade structured parking. Parking and service access is to accessed from Fleet Street and must be integrated into the design of the built form and landscape. Parking ramps are to be perpendicular, not parallel, to the street. CROSS-SECTION OF LLOYD STREET, LOOKING NORTH (DEMONSTRATION PLAN) RESIDENTIAL BUILDING EDGE (DEMONSTRATION PLAN) 41

Block 4 Description Block 4 is a development block located on the east side of Booth Street. Booth Street will become the main shopping street of the LeBreton Flats community. Buildings fronting onto Booth Street and the westerly half of the Fleet Street frontage will be configured with retail at the ground floor. Block 4 also has direct frontage on Lloyd Street to the east and Fleet Street to the north. The allowable form of development consists of mixed use, with mandatory retail and commercial uses at the ground level oriented to Booth Street and the westerly half of the Fleet Street and the residential component oriented to Fleet and Lloyd streets and the easement south of Block 4. Setback dimensions along Booth Street, Fleet Street and Lloyd Street easement property lines are compulsory "build-to" lines. Zoning The west and north portions of Block 4 are zoned CN9, which permits a range of service, commercial, office and residential uses. The east portion of the block is zoned CN9 permitting the same uses as on the west and north of the block, except that most service commercial and some community uses are prohibited. A maximum height of 40m. above grade is permitted. BLOCK 4, PROPERTY BOUNDARIES, SCALE 1:750 42

Block 4 Block Organization The compulsory built-to lines will result in an organization of Block 4 that will reflect a perimeter configuration residential buildings fronting onto Booth Street, Fleet Street, the southern easement, and Lloyd Street and possibly forming an internal courtyard. The height of the buildings fronting on Booth and Fleet streets shall be 6 stories or 20m. Point towers shall be restricted to the Booth Street frontage, however they shall be limited to a maximum floor plate of 700 square metres and shall occupy no more than 50% of the Booth Street frontage. The elevation of Booth Street may be raised in the future by the City of Ottawa to accommodate the future Transitway/Booth Street grade-separated interface. The implication of this modification of the existing grades is that the levels and grade conditions of the built form must be carefully resolved to ensure that the ground floor of buildings and the mandatory retail use follow and are contiguous with the planned, finished grade along Booth Street from the south right-of-way line of Fleet Street to the south property line of Block 12. Purchasers shall satisfy themselves as to the intentions of the City of Ottawa to relocate the Transitway and grade-separate Booth Street. Setbacks and Build-To Lines Measured from Property Line: Up to 20 Metre Height: Booth St. Fleet St. residential Fleet St. retail Lloyd St. Southern Frontage 0.5m Build-To line 3.0m Build-To line 0.5m Build-to line 3.0m Build-To line 3.0m Setback Above 20 Metre Height: Booth Street Fleet Street Southern Easement 2.5m Setback 3.0m minimum Setback 3.0m minimum Setback DEMONSTRATION PLAN FOR BLOCK 4, SCALE 1:750 Minimum Building Height: 20m. and 6 storeys on Booth and Fleet Streets 14m. and 4 Storeys on Lloyd Street Maximum Overall Building Height: 40.0m 43

Block 4 The building envelope is illustrated in these sections. It is mandatory that the built form be articulated by its architecture within the maximum height limits and setbacks, both in plan and in section. The 4th floor or 14m. height must be acknowledge by a setback of at least 1.5m. and/or by an acceptable architectural device such as a cornice. SECTION OF DEMONSTRATION PLAN FOR BLOCK 4, SECTION P2-P2, SCALE 1:500 SECTION OF DEMONSTRATION PLAN FOR BLOCK 4, SECTION P1-P1, SCALE 1:500 44

Block 4 RESIDENTIAL BUILDING EDGE (DEMONSTRATION PLAN) RETAIL BUILDING EDGE (DEMONSTRATION PLAN) Edge Conditions Residential Ground floor dwelling units are to be addressed, have direct access from, and windows facing into the street. Ground floor dwelling units and their front porch/yard areas to be elevated a minimum of 0.6m. and a maximum of 1.2m. above the adjacent sidewalk grade. Retail Ground floor retail is to be located at, and accessed directly from, sidewalk level. Small courtyards may be incorporated into the street wall of the frontage base of the building to express an entry. Retail storefronts shall be designed to suit the needs of neighbourhood retail with accommodation of outdoor display and sales. A continuous permanent weather protection device, such as a canopy or awning, shall extend along the entirety of the retail frontage to afford pedestrian amenity. Minimum width for the weather protection device is 1.5m with a ground clearance of 2.5m to the underside of structure and as permitted by municipal regulation. Parking and Servicing All parking is to be located in below-grade structured parking. Parking and service access is to accessed from Fleet Street and must be integrated into the design of the built form and landscape. Servicing for the Booth Street retail and office component is to be "over-the-curb" from Booth Street. Parking ramps are to be perpendicular, not parallel, to streets. CROSS-SECTION OF LLOYD STREET, LOOKING NORTH (DEMONSTRATION PLAN) CROSS-SECTION OF SOUTHERN EASEMENT, LOOKING EAST (DEMONSTRATION PLAN) 45

Block 12 Block Description Block 12 is located directly north of the aqueduct, south of the easement, and east of Booth Street. This block has both a unique location within the development and interface with Booth Street along its western frontage. The raised elevation of Booth Street, in order to accommodate the proposed grade separated roadway over the Transitway and vehicular traffic on Booth Street, creates a condition in which the road elevation is approximately 6m higher than the base grade condition of the block. This raised interface will have to be carefully resolved to address the livability of residential units along the western edge of the development block. Built form for this block will consist of a minimum of 6 stories or 20m. residential or residential/mixed use building. A point tower would be permitted, however its maximum floor plate area shall be no greater than 700 square metres. Setback dimensions from the north, east and west property lines are compulsory "build-to" lines. Zoning The zoning designation applied to this parcel of land is R7D, which permits a range of service commercial and retail uses at grade and residential on the floors above. The maximum permitted height is 40.5m. BLOCK 12, PROPERTY BOUNDARIES, SCALE 1:750 46

Block 12 Block Organization The organization of Block 12 is a single building envelope due to the dimensional constraints in the north-south dimension. Setbacks and Build-To Lines Measured from Property Line Up to 14m and 4 storeys: Northern easement Booth Street Eastern Boundary Southern Frontage 3.0m Build-To Line 0.5m Setback 0.5m Setback 0.5m Setback Above 14 Metre Height: Northern easement Booth Street Eastern Boundary Southern Frontage 3.0m Setback 2.5m Setback 3.0m Setback 3.0m Setback Minimum Building Height: 20m and 6 storeys Maximum Building Height: 40.5m DEMONSTRATION PLAN FOR BLOCK 12, SCALE 1:750 47

Block 12 The building envelope is illustrated in these sections. It is mandatory that the built form be articulated by its architecture within the maximum height limits and setbacks, both in plan and in section. The 4th floor or 14m. height must be acknowledge by a setback of at least 1.5m. and/or by an acceptable architectural device such as a cornice. SECTION OF DEMONSTRATION PLAN FOR BLOCK 12, SECTION I1-I1, SCALE 1:500 SECTION OF DEMONSTRATION PLAN FOR BLOCK 12, SECTION I2-I2, SCALE 1:500 48

Block 12 Edge Conditions Residential Ground floor dwelling units to be addressed, have direct access from, and windows facing into the street. Ground floor dwelling units and their front porch/yard areas to be elevated a minimum of 0.6m. and a maximum of 1.2m above the adjacent sidewalk grade. Parking and Servicing All parking is to be located in below-grade structured parking. Parking and service access is to accessed from the northern easement and must be integrated into the design of the built form and landscape. Parking ramps are to be perpendicular, not parallel, to the street. CROSS-SECTION OF NORTHERN EASEMENT, LOOKING EAST (DEMONSTRATION PLAN) 49