GROWTH MANAGEMENT DIVISION NAPLES, FLORIDA (239) FAX: (239)

Similar documents
Application for a Public Hearing for PUD Rezone, Amendment to PUD or PUD to PUD Rezone

MIXED USE PROJECT PLAN (MUP)

APPLICATION FOR PUBLIC HEARING FOR:

Instructions and Application Procedures Plan Amendments

COLLIER COUNTY Growth Management Department Engineering Review Services

ORANGE BLOSSOM GARDENS PLANNED UNIT DEVELOPMENT PREPARED BY: COASTAL ENGINEERING CONSULTANTS, INC.

CITY OF OCOEE LAND DEVELOPMENT CODE SUFFICIENCY TABLE WITH NOTES

City of Colleyville Community Development Department. Subdivision Application Packet

Collier County. Land Development Code - Administrative Code DRAFT 2 Thursday, August 15, 2013

STREAM BUFFER VARIANCE APPLICATION PACKET

Final Plat Approval of a Minor Subdivision Application Packet

FINAL PLAT SUBMITTAL CHECKLIST

CITY OF PAHOKEE SITE PLAN SUBMITTAL REQUIREMENTS

APPLICATION PACKET SINGLE FAMILY CLUSTER HOUSING OPTION REVIEW

LAND DEVELOPMENT CODE NATURAL RESOURCES PERMIT APPLICATION INFORMATION PACKET

APPLICATION. Telephone Fax Address. Telephone Fax Address FOR MARTIN COUNTY USE ONLY

Minor Subdivision Application

Planned Residential Development ( PRD ) Application

APPLICATION PACKET SINGLE FAMILY CLUSTER HOUSING OPTION REVIEW

APPLICATION MAJOR MINOR DEVIATION - DEVELOPMENT - - SP (project number assigned by planning staff)

APPLICATION PROCESS FOR PROJECT REVIEW

COLLIER COUNTY Growth Management Department

Plat/Site Plan Application

APPLICATION PACKET LAND SPLIT OR COMBINATION REVIEW

Larimer County Planning Dept. Procedural Guide for 1041 PERMITS

Community Development District INFORMATION PACKET

Administrative Plat Application Form

Plans shall be drawn at a readable scale, signed, and sealed by a Florida Registered Engineer. The application package shall include:

Final Plat Approval of a Major Subdivision Application Packet

Floodplain Development Land Use Review

VARIANCE APPLICATION PACKET

Economic Non-Viability Application

Class II, Type 11 Site Plan Conceptual/Preliminary Conceptual CITY: STATE: ZIP: TELEPHONE: ( ) 2. AUTHORIZED REPRESENTATIVE NAME: ADDRESS:

City: State: City: State: Phone: ( ) Fax: ( ) Phone: ( ) Fax: ( ) Project Information

PLANNED UNIT DEVELOPMENT APPLICATION

APPLICATION PACKET SUBDIVISION PLAT REVIEW TENTATIVE PRELIMINARY PLAT

PUD SKETCH PLAN APPLICATION

APPLICATION PACKET LAND SPLIT OR COMBINATION REVIEW

City of Eustis Development Services Checklist for Submittals by Application Type

R e z o n i n g A p p l i c a t i o n S u b m i s s i o n R e q u i r e m e n t s

New Electronic Planning Commission Submittal Process

TOWN OF LANTANA. Preserving Lantana s small town atmosphere through responsible government and quality service.

MINOR SUBDIVISION INFORMATION

Individual Well Individual Septic. Community Well 19. What is the proposed method of sewage disposal? Public. None

SITE DEVELOPMENT PLAN REQUIREMENTS CHECKLIST

Leon County APPLICATION FOR PUD REZONING REVIEW

CITY OF NORTH PORT Neighborhood Development Services Planning Division Final Plat/Re-Plat Packet

FINAL PLAN CHECKLIST

Temporary Use Permit. A guide to the Application Process

CITY OF ALTAMONTE SPRINGS

City of East Orange. Department of Policy, Planning and Development LAND USE APPLICATION & SITE PLAN REVIEW CHECKLIST

PETITION TO VACATE A STREET, ALLEY, OR EASEMENT APPLICATION

Septic Tank / Drainfield / Holding Tank Permit Application

City Of Attleboro Conservation Commission

Initial Subdivision Applications Shall Include the Following:

Site Plan Application

PRELIMINARY PLAT APPLICATION INFORMATION

Tentative Map Application Review Procedures

PROCEDURE LIST FOR LARGE-SCALE FUTURE LAND USE AMENDMENT

Reference: Planned Unit Development Rezone PL Collier County Resource Recovery Business Park Sufficiency Response No. 2

PLANNED DEVELOPMENT / CONDITIONAL USE PERMIT Application

Application for Conservation Area Impact Permit

(if more than one, give square footage for each) ANNEXATION LOT LINE Adjustments PRE/FINAL PLAT SPECIAL USE PERMIT

SMALL CELL TECHNOLOGY in the Right-of-Way ADMINISTRATIVE VARIANCE APPLICATION Community Development Department

SPECIAL USE PERMIT APPLICATION FOR NATURAL DEPOSITS, EXTRACTION AND PROCESSING; CONCRETE BATCH PLANTS; HOT MIX (ROAD/ASPHALT) PLANTS

AAR SUBMITTAL CHECKLIST

City of Eustis Development Application

MIAMI SHORES VILLAGE

CITY OF FAYETTEVILLE, ARKANSAS FINAL PLAT FOR STAFF USE ONLY FINAL PLAT FEE: $ $ Date Application Submitted: Date Accepted as Complete:

Septic Tank / Drainfield / Holding Tank Permit Application

Township of Collier 2418 Hilltop Road Presto, PA 15142

Village of Lake Zurich Zoning Application Guide

Level III Preliminary and Final Site Plans Development Review Application Portland, Maine Planning and Urban Development Department Planning Division

Residential Minor Subdivision Review Checklist

CITY UTILITIES DESIGN STANDARDS MANUAL

APPLICATION PROCEDURES FOR A PLAT AMENDMENT OR REVISION

Residential Major Subdivision Review Checklist

APPLICATION REVIEW CHECKLISTS

APPLICATION FOR NOTICE OF PROPOSED CHANGE

SITE PLAN REVIEW ADMINISTRATIVE REVIEW. Please Note: Once submitted to the County, all application materials become a matter of public record.

CITY OF SPRINGDALE, OHIO SPRINGDALE BUILDING DEPARTMENT SPRINGFIELD PIKE SPRINGDALE, OHIO TELEPHONE: (513)

SUBDIVISION AND / OR LAND DEVELOPMENT SUBMITTAL REQUIREMENTS

City of Nogales Planning & Zoning Commission Rezoning Application

SPECIAL EXCEPTION SITE PLAN REVIEW

FINAL PLAT AMENDMENT APPLICATION Minor / Major / Administrative (Revised 3/1/2017)

ST. TAMMANY PARISH PATRICIA P. BRISTER PARISH PRESIDENT

APPLICATION PROCEDURES FOR A MAJOR SUBDIVISION PRELIMINARY PLAT

City of Altamonte Springs Developer s Guide

Planned Unit Development

Workforce Housing Density Bonus

CITY OF SPRINGDALE, OHIO SPRINGDALE BUILDING DEPARTMENT SPRINGFIELD PIKE SPRINGDALE, OHIO TELEPHONE: (513)

SUBDIVISION APPLICATION CHECKLIST SKETCH PLAN PRELIMINARY PLAT FINAL PLAT

TENTATIVE MAP INFORMATION SHEET

2401 S. E. Monterey Road, Stuart, FL Plat Application Martin County Growth Management Department

PASCO COUNTY, FLORIDA INTEROFFICE MEMORANDUM

W E S T T O W N T O W N S H I P 1039 Wilmington Pike P.O. Box 79 West Chester, PA Westtown, PA PHONE: (610) FAX: (610)

SKETCH PLAN REVIEW SPECIAL EXCEPTION, SPECIAL REVIEW,

SPECIAL EXCEPTION SITE PLAN REVIEW

COMMERCIAL PLAN REVIEW PACKET

ST. TAMMANY PARISH PATRICIA P. BRISTER PARISH PRESIDENT

Transcription:

GROWTH MANAGEMENT DIVISION NAPLES, FLORIDA 310 www.colliergov.net (239) 252-200 FAX: (239) 252-6358 Subdivision Construction Plans and Plat (PPL) Application LDC Section 10.02.0, and other provisions of the LDC Chapter 5 D.1. of the Administrative Code PROJECT NO PROJECT NAME DATE PROCESSED For Staff Use Only APPLICANT CONTACT INFORMATION Name of Applicant: Firm: Address: City: State: ZIP: Telephone: Cell: Fax: E-Mail Address: Name of Owner: Address: City: State: ZIP: Telephone: Cell: Fax: E-Mail Address: PROPERTY INFORMATION Provide a detailed legal description of the property covered by the application, if space is inadequate, attach on a separate page: Project Name: Property ID Number: Address of subject site and general location: Zoning District: Section/Township/Range: / / Subdivision: Unit: Lot: Block: 7/30/201 Page 1 of 5

GROWTH MANAGEMENT DIVISION NAPLES, FLORIDA 310 www.colliergov.net (239) 252-200 FAX: (239) 252-6358 Pre-Application Meeting and Final Submittal Requirement Checklist for: Subdivision Construction Plans and Plat Chapter 5 D.1. of the Administrative Code The following Submittal Requirement checklist is to be utilized during the Pre-Application Meeting and at time of application submittal. At final submittal, the checklist is to be completed and submitted with the application packet. Please provide the submittal items in the exact order listed below, with cover sheets attached to each section. Incomplete submittals will not be accepted. # OF REQUIREMENTS FOR REVIEW COPIES REQUIRED NOT REQUIRED STANDARD REQUIREMENTS: Completed Application (download current form from the County website) 1 Cover Letter explaining the project 1 Completed Addressing Checklist 1 Fee Calculation Worksheet & Review fees, signed 1 Digital file of conditional use or PUD application, if applicable 1 PUD Monitoring Schedule 2 PUD Ordinance and Development Commitment Information, as applicable 12 Affidavit of Authorization & Evidence of Authority 2 Opinion of Title 1 Letter of Intent as to the timeline for construction and platting 2 Home Owner Association documents, if applicable 2 Aerial Photograph with all information legible at the scale provided 3 Certificate of Public Facility Adequacy application with fee 2 Fire Flow tests 2 Zoning Data Sheet Historical/Archeological Survey or waiver, if applicable Environmental Data Requirements 3 Transportation Impact Study 7 School Impact Analysis Application for residential projects only (download the School Impact Analysis Application from website) 2 Information and data relating to previous zoning actions affecting the project site Utility Letters of availability and plat easement approval letter for utility easements, if applicable 1 Engineer s Report, including assumptions and explanations, with the following included: Completed calculations used to design the facilities, including but not limited to all water, sewer, road, water management systems, and all accessory facilities, public or private; Detailed hydraulic design calculations utilized to design the stormwater management facilities for the subdivision or development; Detailed hydraulic design calculations utilized to design the water and sewer facilities regulated by the County. Geo-technical report with soil boring results; Engineering Review Checklist, signed and sealed by the applicant s professional Engineer; Engineer s Opinion of probable cost; and Status of all other required permits including copies of information and data submitted to the appropriate permitting agencies. 7/30/201 Page 2 of 5

GROWTH MANAGEMENT DIVISION NAPLES, FLORIDA 310 www.colliergov.net (239) 252-200 FAX: (239) 252-6358 Permits: All Federal, State and local permits, including but not limited to the following, shall be submitted prior to construction and before the pre-construction meeting. If approved by the County Manager or designee, an applicant may submit Federal, State and local agency permits at the pre-construction meeting. SFWMD Permit, Permit Modification, or waiver, including staff report 2 exhibits; DEP utility installation permits, water/sewer; Right-of-Way Permit; and US Army Core of Engineers permit and exhibit, if applicable. Vegetation Removal and Site Filling permit, if requested Provide separate acreage calculations for each phase of clearing requested; If clearing or filling lots and building sites, with or without stockpiling, a 1 separate VRSFP application shall be submitted, pursuant to LDC subsection.06.0 A.2.; and A site clearing plan, see Requirements for Construction Plans in Chapter 5 D.1. of the Administrative Code for more information. Streetlight Plans, signed and sealed by a professional Engineer licensed to practice 7 in the State of Florida or the utility provider Landscape Plans, signed and sealed by a landscape architect registered in the 5 State of Florida Irrigation Plans, signed and sealed by a landscape architect or irrigation designer 5 Electronic copies of all documents and plans 1 Construction Plans, see Requirements for Construction Plans in Chapter 5 D.1. of 1 the Administrative Code Water Management for Construction Plans, see Requirements for Water 1 Management for Construction Plans in Chapter 5 D.1. of the Administrative Code Final Subdivision Plat, see Requirements for Final Subdivision Plats in Chapter 5 1 D.1. of the Administrative Code For a Townhouse Fee Simple Development, see Chapter 5 D.2. of the 1 Administrative Code for additional submittal requirements *If located in the FRMUD or RLSAO areas, include an additional set of each submittal requirement If located in RFMU (Rural Fringe Mixed Use) Receiving Land Areas Pursuant to LDC subsection 2.03.08.A.2.a.2.(b.)i.c., the applicant must contact the Florida Forest Service at 239-690-3500 for information regarding Wildfire Mitigation & Prevention Plan. School Concurrency - If the proposed project includes a residential component, you are required to contact the School District of Collier County at 239-377-0267 to discuss school concurrency requirements. Applicant/Agent Signature Date 7/30/201 Page 3 of 5

COLLIER COUNTY GOVERNMENT GROWTH MANAGEMENT DIVISION www.colliergov.net NAPLES, FLORIDA 310 (239) 252-200 FAX: (239) 252-6358 Subdivision Construction Plans and Plat Fee Calculation Worksheet x () x () Subdivision Review Fees (PPL): Paving Grading, and Drainage Review and Inspection Fee 271,205 Construction Cost Estimate: o Construction Documents Review Fee: 0.75% of probable Paving, Grading, Drainage, Lighting, Code Minimum Landscaping and any other appurtenant cost of construction 2,03.0 $ o Subdivision Inspection fee: 2.25% of probable Paving, Grading, Drainage, Lighting, Code Minimum Landscaping, and any other appurtenant cost of construction ($271,205 x 2.25%=$6,102.11 / 2 = $3,051.06) 3,051.06 Plat Review Fees: o Residential: $1000.00 Base Fee plus $5.00 per acre (round up to the next acreage) o Non-Residential: $1000.00 Base Fee plus $10.00 per acre (round up to the next acreage) Certificate of Public Facility Adequacy, if required: $200.00 plus $25.00 per residential dwelling unit ($5,000.00 maximum) Environmental Impact Statement, if required: $2,5000.00 for 1st submittal and 2nd submittal, additional fees apply for 3rd and subsequent submittals Listed or Protected Species review fee, if required: $1,000.00 Site Clearing Permit, if required: $250.00 for first acre or fraction of an acre, $50.00 per additional acre or fraction of an acre ($3,000.00 maximum) Utility Plan Review and Inspection fees: Utility Cost Estimate: o Construction Document Review: 0.75% of probable water and/or sewer construction costs o Construction Inspection: 2.25% of probable water and/or sewer construction costs Excavation Permit (Development): $00.00 (Commercial: $2,000) 2,000 Transportation Methodology Review fee, if required: $500.00 to be paid at Methodology Meeting, additional fees to be determined at that time o Right-of-way Permit: To be determined by Transportation School Concurrency fee, if required: [reserved] (mitigation Fees, if applicable, to be determined by the School District in coordination with the County) Utility Modeling and Analysis fee, applicable to projects zoned PUD or DRI: $1,000.00 7,085.10 500.00 Pre-Application Meeting fee credit: 6,585.10 Total: 7/30/201 Page of 5

GROWTH MANAGEMENT DIVISION NAPLES, FLORIDA 310 www.colliergov.net (239) 252-200 FAX: (239) 252-6358 Allowed Dwelling Units and Square Footage within PUD s The attached form must be submitted with all reviews that involve the addition and/or deletion of dwelling units or square footage. (Some examples: SDP, SDPA, SDPI, PPL, PPLA, ICP) The form allows the individual owners, developer, agents, and County staff to track remaining units and square footage in order to avoid going over the maximum allowed by the PUD Ordinance. Instructions to complete: Project Name: Name of the project PUD Name: Name of the PUD Review #: To be completed by County staff This submittal: The addition and/or deletion of single family units, multi-family units, commercial square footage for office, retail or other, industrial square footage, medical, special, or other square footage. When choosing Other or Special square footage please indicate when the other or special type is. Approved to Date: Total approved units and/or square footage within the entire PUD. Please complete for all categories. Maximum Allowable per PUD Ordinance: Maximum limits provided for each category per the PUD Ordinance. Please include the Ordinance number. Acreage Constructed to Date: Some of the PUD s allow construction based upon acreage rather than square footage limits. These are usually the older PUD s. Maximum Allowed: Maximum acres allowed to be constructed based upon the PUD Ordinance. Signature of Owner or Agent: Please sign Date: Please date with submittal All lines must be completed. If a line is not applicable, please write. 7/30/201 Page 5 of 5