CHARLESTON PLACE TENANT CALCULATION CHECK/DATA TABULATION SHEET(S) Forms must be completed by the Tenant's Mechanical or Electrical Engineer.

Similar documents
Submission Procedures

Fee Type How Determined Rate Permit Processing Charge Flat Permit or Plan Review Submittal $32.00

CHAPTER 1321 Permit and Inspection Fees

DEPARTMENT OF BUILDING AND SAFETY

TENANT DESIGN MANUAL UPDATED JULY 2015

List of Principal Officials

TENANT DESIGN MANUAL UPDATED AUGUST 2016

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED DECEMBER 2018

TENANT DESIGN MANUAL UPDATED JUNE 2015

LANE COUNTY BUILDING & ELECTRICAL PROGRAMS PERMIT FEE GUIDE

TENANT DESIGN MANUAL UPDATED AUGUST 2015

TENANT DESIGN MANUAL UPDATED JULY 2016

LANE COUNTY BUILDING & ELECTRICAL PROGRAMS PERMIT FEE GUIDE

TENANT DESIGN MANUAL UPDATED JUNE 2015

COUNTY OF FREDERICK INSPECTIONS DEPARTMENT FEE SCHEDULE Approved July 14, COMMERCIAL FEES Minimum Fee $ unless stated otherwise

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015

Fee Resolution

TENANT DESIGN MANUAL UPDATED MAY 2016

TENANT DESIGN MANUAL UPDATED JUNE 2015

TENANT DESIGN MANUAL UPDATED JUNE 2016

GROUNDING/BONDING SCALE: 1/8" = 1'-0"

TENANT DESIGN MANUAL UPDATED FEBRUARY 2017

TENANT DESIGN MANUAL UPDATED JUNE 2015

TENANT DESIGN MANUAL UPDATED OCTOBER 2016

TENANT DESIGN MANUAL UPDATED JUNE 2015

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATE JUNE 2015

BUI L DIN G A ND E L E V A T O R F E ES

1. Permit Fees for new single family dwellings, duplexes, and multifamily dwellings with eight units or less are as follows:

TENANT DESIGN MANUAL UPDATED OCTOBER 2016

TENANT DESIGN MANUAL UPDATED JULY 2015

Permit Fees for The City of Monroe **Effective July 2, 2018** Table of Contents

RESOLUTION NO

City of Oregon City. Community Development Building Division Fee Schedule Effective April 1, 2016 BUILDING DIVISION

BUILDING PERMIT FEE ESTIMATE

CITY OF CORTEZ COUNCIL RESOLUTION NO. 45, SERIES 2016

TENANT DESIGN MANUAL UPDATED JULY 2015

NEW BRITAIN BOROUGH SCHEDULE OF FEES (Revised April 9, 2019)

GENERAL INFORMATION. Landlord s Tenant Coordinator

Amendment to the City s Master Schedule of Fees, Charges & Application Fees

TENANT DESIGN MANUAL UPDATED JANUARY 2016

TENANT DESIGN MANUAL UPDATED FEBRUARY 2017

APPENDIX A BUILDING PERMIT AND RELATED FEES

TENANT DESIGN MANUAL UPDATED JULY 2015

This fee structure applies to applications submitted on or after January 1, 2018.

DESCRIPTION OF LANDLORD'S WORK & TENANT'S WORK

Tenant Design Criteria Section t Technical Criteria Updated: August Wilton Mall at Saratoga 3065 Route 50, Saratoga Springs, NY 12866

Construction Document Criteria

City of Ridgefield, WA Master Fee Schedule Effective Date: February 24, 2017

TENANT DESIGN MANUAL UPDATED JULY 2015

The Promenade at Casa Grande 1005 N Promenade Pkwy Casa Grande, AZ 85294

NEW BRITAIN BOROUGH SCHEDULE OF FEES (Revised December 15, 2017)

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015

Design and Construction Document Criteria

DEVELOPMENT FEES BUILDING AND ENGINEERING DEVELOPMENT SERVICES DEPARTMENT. Effective July 1, 2016 FEE CHARGES TABLE OF CONTENTS

Bangor Mall Bangor, ME

TOWN OF HERNDON, VIRGINIA ORDINANCE MAY 26, 2015

TENANT DESIGN MANUAL UPDATED JUNE 2015

TENANT DESIGN MANUAL UPDATED JULY 2015

CONSTRUCTION PERMIT FEE SUMMARY

Construction Document Criteria

TECHNICAL CRITERIA ARROWHEAD TOWNE CENTER THE PLACE TO SHOP

San Tan Village 2218 E. Williams Field Rd. #235, Gilbert, AZ 85295

County of Fresno / Public Works and Planning Master Schedule of Fees for Development Services, Effective January 3, 2008

Exhibit C - Shops 1 & 2

E x p a n s i o n P r o j e c t

Construction Document Criteria

MASTER SCHEDULE OF FEES, CHARGES, AND RECOVERED COSTS SECTION DEVELOPMENT SERVICES

CITY OF TARPON SPRINGS, FLORIDA

14400 Bear Valley Road, Victorville, CA 92392

TECHINICAL CRITERIA DEPTFORD MALL THE PLACE TO SHOP

FY 2018 FEE SCHEDULE (Effective )

320 Bay Street TORONTO ONTARIO. Tracy Macdonald Vice President,

Fees for construction of all buildings except single family dwellings, shall be calculated using Table 2.

Outline of Plan Check Submittal and Required Fees for New Residential Construction

WEST VINCENT TOWNSHIP COMMERCIAL BUILDING PERMIT

User Fees Revised 08/20/2018

RESOLUTION NO 364 A RESOLUTION OF THE WOODINVILLE CITY COUNCIL, REPEALING RESOLUTION 357, ESTABLISHING REVISED DEVELOPMENT SERVICES FEES.

GRAND CENTRAL TERMINAL NEW YORK, NY MECHANICAL, ELECTRICAL AND PLUMBING TENANT DESIGN CRITERIA HANDBOOK

General Information RETAIL AND RESTAURANT

New Business Information Packet

Violet Township requires Zoning and Plans Examination and Building Permits for all new construction.

Administration Fees Photocopies $ Returned Checks $ Credit Card Convenience Fee $ 1.50 minimum OR 2.45%

CITY OF SAN MATEO COMPREHENSIVE FEE SCHEDULE. Table of Contents. Building Code Enforcement Planning Information Technology...7.

City of Sand Springs, Oklahoma Planning and Development Department Neighborhood Services Office

SOUTHLAKE MALL. Southlake Mall Tenant Design & Construction Criteria TENANT DESIGN & CONSTRUCTION CRITERIA PROPERTY SPECIFIC REQUIREMENTS

Office Space For Lease

a) Tenant shall require its Contractor to provide and maintain the following insurance coverage:

TENANT DESIGN MANUAL UPDATED JUNE 2015

Positano Waterfront Residences. Copyright 2016, Miromar Development Corporation.

RICK READ Phone: ANNJO COURT, FOREST, VA

TWELVE OAKS GENERAL INFORMATION (BUILDING E ONLY)

Planning Zoning Addendum of Fees. Item/Service. Agricultural Lot Split $ Conditional Use Application $300.00

th Street Boulder CO 80301

Shoreview Corporate Center

12325 EMMET STREET. $9.50 psf NNN 17,754 SF OFFICE FOR LEASE Emmet Street Omaha, Nebraska * * CERTIFIED *

FOR SALE OR LEASE. Manufacturing / Distribution Facility 43,200± SF ± Acres. 302 Veterans Parkway Barnesville, Lamar County, Georgia 30204

Transcription:

TENANT CALCULATION CHECK/DATA TABULATION SHEET(S) DIRECTIONS FOR COMPLETION GENERAL: I. All blanks on the form must be filled in. II. III. IV. Forms must be completed by the Tenant's Mechanical or Electrical Engineer. The Project Architect/Manager is responsible for insuring mechanical and electrical coordination. If the forms are not filled out or if they are not returned with the drawings for approval, the tenant documents will be considered as not received. MECHANICAL: I. Only recognized ASHRAE methods are to be employed. II. III. The check sheet is not intended to be a calculation method but merely a standard summary of data as was used by the Tenant's design engineer. All factors provided are minimums. Heat loss calculations are not required as the heat gain calculations will dictate the heat pump size(s). ELECTRICAL: I. All data presented shall be per NEC. 1 of 5

HEAT PUMP SPECIFICATIONS TYPE "B" TYPE "C" TYPE "D" Model No. RC-090 (McQuay) Nominal 3/4 Ton, Total BTUH = 9,000, 310 CFM Physical Size: 20" long x 42" wide x 10-1/2" high Outlet Duct Connection Size: 30-1/8" x 7" Electrical Load: 0.82 KW at 277 volt, 1 phase Model No. CC-200 (McQuay) Nominal 2 Ton, Total BTUH = 20,000, 820 CFM Physical Size: 24" long x 30" wide x 16-1/4" high Outlet Duct Connection Size: 9-3/8" x 9" Electrical Load: Compressor = 6.3 FLA at 277 Volt, 1 phase Blower Fan = 12.1 FLA at 277 volt, 1 phase Model No.CC-500 (McQuay) Nominal 4 Ton, Total BTUH _ 50,000, 1800 CFM Physical Size: 24" long x 47" wide x 20" high Outlet Duct Connections Size: 13-1/4" x 7-1/4" Electrical Load: Compressor = 6.2 FLA at 480 volt, 3 phase Blower Fan = 2.2 FLA at 277 volt, 1 phase The packaged heat pump(s) requires a clear assess opening in the ceiling below the unit for maintenance, filter replacement and removal/replacement of unit. Unit Type Minimum Opening (Clear) "B" 36" x 48" "C" 36" x 38" "D" 36" x 54" 2 of 5

TENANT LOAD CALCULATION CHECK SHEET - MECHANICAL TENANT SUITE# FLOOR AREA SQ. FT. PRODUCT/SERVICE COOLING LOAD CALCULATIONS ITEM BTU/HR Lighting watts including ballast x 3.41 = Showcase lighting watts including ballast x 3.41 = Equipment watts x 3.41 = OR HP x 2545 = People sq. ft. floor area x 250 = 75 sq. ft./person Exterior walls (without glass) linear feet x 30 = Exterior walls (with glass) East = linear feet x 180 = South = linear feet x 180 = North = linear feet x 180 = West = linear feet x 1820 = Ventilation sq. ft. floor area x 195 75 sq. ft./person (Allow minimum of 2,000 BTU/Hr.) = HEAT PUMP SELECTION: Quantity (Furnished by Landlord, Installed by Tenant) Requested Type "B", Nominal 3/4 Ton, Total BTUH = 9,000 Type "C", Nominal 2 Ton, Total BTUH = 20,000 Type "D", Nominal 4 Ton, Total BTUH = 50,000 TOTALS = 3 of 5

ELECTRICAL DATA TABULATION SHEET CHARLESTON PLACE TENANT'S NAME AREA (SQ. FT.) MAIN FLOOR SUITE NO. MEZZANINE LOAD TYPE: CONNECTED KW: SPACE LIGHTING SHOWCASE LIGHTING SIGN LIGHTING RECEPTACLES WATER HEATING (Food & Beverage Tenants Only) **SPECIAL APPLIANCES OR EQUIPMENT MISCELLANEOUS (INDICATE) HEAT PUMP - AIR CONDITIONING (HP, KW OR FLA) EXHAUST HOOD FAN(S) (Food & Beverage Tenants Only) MAKE-UP AIR FAN(S) (Food & Beverage Tenants Only) LARGEST MOTOR TOTAL MOTOR (HP) TRANSFORMER SIZE (KW or KVA - INDICATE) TOTAL CONNECTED LOAD (KW) TOTAL SIMULTANEOUS LOAD (KW) (MAINTAINED AT 3 HRS. OR MORE) **Identify location on plan and exact function, include separate sheet outlining equipment name, location, KW or HP, etc. PREPARED & CERTIFIED BY: Do Not Write Below This Line 480/277 VOLT, 3 PH, 4 W SERVICE PROVIDED BY THE TENANT (LTG, & PWR) CONDUCTORS SWITCH CONDUIT FUSE 4 of 5

CONSTRUCTION INFORMATION FORM To be completed, signed and returned to Landlord pursuant to Exhibit "B", Section V, Paragraph B of the Lease. Tenant Coordinator RE: 1. General Contractor: 2. Mechanical Contractor: 3. Plumbing Contractor: 4. Electrical Contractor: 5. Sprinkler Contractor: 6. Commencement Date of construction: 7. Estimated date of completion: 8. Estimated date of fixturing: 9. Estimated date of projected opening: 10. Evidence of insurance as set forth in Section V, Item G, Exhibit "B" of the Lease Agreement. Tenant's Signature: Date: Landlord Approval: Date: NOTE: LANDLORD'S APPROVAL MUST BE OBTAINED PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 5 of 5