..0 BUILDING ; BRI LP RE - 6.m² BUILDING B ; UNITS,2,, GL - 66.7m² BUILDING C UNITS,6,7,7 GL - 96.6m² BUILDING D ; UNITS,9,0,,2 GL - 62.7m² BUILDING E ; BR GL -.7m² RE : 2.ha EXISTING HOTEL BUILDING FOOTPRINTS : 279.m² COVERGE :.2% HEIGHT : 2 STOREYS GL :.9m² PRKING : 2 BYS (. BYS PER UNIT) NO. UNITS : 2 DENSITY : 2.du/ha BUILDING LINES : N/ EXISTING BUILDINGS BUILDING F ; DINING HLL, OFFICE,RECEPTION, LIBRRY,TV,CONFERENCE ROOM GL - 7.6m² BUILDING G ; GL -.66m² BUILDING H ; UNITS,,6, KIDS DINING HLL, COLD ROOM, SMLL FREEZER GL - 6.70m² BUILDING I ; FREEZER GL - 2.m² BUILDING J ; UNIT 27, ROOM GL - 2.2m² BUILDING K ; UNIT 29,0, GL -.79m² BUILDING L ; UNIT 2 GL - 2.6m² BUILDING M ; UNIT 2,2,2, GL - 0.6m² BUILDING N ; UNIT 2, 22 GL - 62.72m² BUILDING O ; UNIT 7, GL -.7m² OVERLL LND DEVELOPMENT YIELD RE : 0.ha BUILDING FOOTPRINTS : 66.m² COVERGE : % HEIGHT : 2 STOREYS GL : 27.2m² PRKING : 6 BYS (.7 BYS PER UNIT) NO. UNITS : 2 DENSITY : 2.6du/ha BUILDING LINES : 0m COVERGE : S PER MX. STIPULTED IN THE LND USE RESTRICTIONS TBLE HEIGHT : S PER MX. STIPULTED IN THE HEIGHT TBLE PRKING (INCL. GRGES): TOTL : 7 BYS 2 BYS PER UNIT (PTNS 2-2,); 2 BYS FOR PTN ; 7 BYS FOR VISITORS NO. UNITS : DENSITY : du/ha SEGULLS RESORT ESTTE =.ha NOTE: NUMBER ND POSITION OF WTER TNKS TO BE DETERMINED BY ENGINEER ND RCHITECT SITE RE : 2.ha TOTL NUMBER OF UNITS : 7 DENSITY :.6du/ha PRKING BYS : 7 (.6 BYS PER UNIT) REGISTERED PROFESSIONL PLNNER D.B. POORTMN PR.PLN BUILDING P ; UNIT,,6 GL - 0.0m² BUILDING Q ; OWNERS COTTGE GL - 0.m² BUILDING R ; LIQUOR STORE GL - 62.9m² BUILDING S ; WORKSHOP GL -.m² BUILDING T ; TOILETS GL - m² BUILDING U ; STFF ROOMS, LUNDRY ROOM GL - 7.6m² BUILDING V ; STFF ROOMS, STORE ROOM GL - 90.m² BUILDING W ; SHOWERS GL - 2.9m² BUILDING X ; GRGES,STORE ROOM,STFF ROOMS GL -.06m² BUILDING Y ; STFF ROOMS GL - m² BUILDING Z ; CONFERENCE FCILITY GL - 9m² BUILDING B ; BOTTLE STORE GL -.m² BUILDING ; TO BE DEMOLISHED BUILDING C ; TO BE DEMOLISHED BUILDING B ; TO BE DEMOLISHED NEW SDP HOTEL (REMINDER)= 0.ha NOVEMBER DTE PROPOSED DDITIONS TO BUILDINGS BUILDING ; TO BE CONVERTED INTO HONEYMOON DDITIONL GL OF 6m² BUILDING C ; 2 DDITIONL UNITS (96.6m² GL) BUILDING D ; 2 DDITIONL UNITS (62.7m² GL) BUILDING E ; TO DD ENCLOSED DECK (±2m² GL) BUILDING F : CONFERENCE ROOM (00 SETS,7.6m²GL) BUILDING M ; DDITIONL UNITS (0.6m² GL) BUILDING N ; 2 DDITIONL UNITS (62.72m² GL) BUILDING P ; 2 DDITIONL UNITS (0.0m² GL) BUILDING Q ; DDITIONL 0.m² GL BUILDING Z TO BE LTERED TO FORM UNIT DDITIONL 9m² GL 7m³ RESERVOIR PIPELINE FROM PUMPSTTION TO PCKGE PLNT NEW SDP HOTEL (PTN ) = 0.67ha RE : 0.67ha BUILDING FOOTPRINTS : 7.79m² COVERGE : 2% HEIGHT : 2 STOREYS GL : 06.97m² PRKING : 2 BYS ( BY PER UNIT) NO. UNITS : 2 DENSITY : 97du/ha BUILDING LINES : 0m SUPPLY FROM RESERVOIR CCESS TO PTN RESERVOIR TO BE DEMOLISHED BMH..0 CCESS INSET SHOWING IRRIGTION RE OF TRETED EFFLUENT TO SCLE S SHOWN TEMPORRY WSTE STORGE m BUILDING LINE ELECTRICL BOXES 7. 2 BMG Z SUBTERRININ DRIN FOR STORMWTER MNGEMENT ELECTRICL LINE 2 27 B. BMJ C 6.. 29.0 7 7.m RODWY 2. 2. 2. 2. 2. 2. 2. 2.. 6 Y 2 2 TELKOM LINE m m m 9 X 7. BMK. 2. 2 6 0.0 V 2. m BUILDING LINE 7m RODWY 60 0 2. U O W 9 7 T DRIN S 2. m RODWY 6 CONCRETE SLB P Q PROPOSED TREES 2 K R m 22 L. 2. 2. BME BMF 6 m 2 7 J M N 7 6 I 2. 2. 2 2. 2. 2. 2. CCESS 2 H 7m RODWY G GTEHOUSE/CCESS CONTROL/SECURITY. 7m RODWY 9 F.0 m 2.60 m 2.60 m. 7m RODWY BM D 6 m BUILDING TO BE LTERED CCOMMODTE 2 DDITIONL UNITS OWNERS COTTGE TO BE LTERED TO DOUBLE STOREY 0m BUILDING LINE 7 6 PUMP STTION 7 6 2.6m 2.6m C m RODWY POND B m PNHNDLE CCESS TENNNIS COURT. 7..0 E CONCRETE TBLE BUILDING TO BE LTERED CCOMMODTE 2 DDITIONL UNITS BUILDING TO BE LTERED CCOMMODTE DDITIONL UNITS POOL REMINDER 7. NOTES ------------ BMB 2. POOL BMD.. BMC - HEIGHT RESTRICTIONS ON THE FOLLOWING PTNS TO BE INCORPO- RTED INTO CONDITIONS OF TITLE & HOME OWNERS SSOCITION 2,,,7,,9,0,. - UNITS IN HOTEL PTNS OTHER THN THOSE THT RE INDICTED TO BE DOUBLE STOREY ON THIS PLN, RE TO REMIN SIE STOREY. - THE NO. OF UNITS IN THE HOTEL PTNS (REMINDER & PTN ) MY NOT INCRESE BEYOND THE NUMBER STTED ON THIS PLN. - NO FURTHER SUBDIVISIONS LLOWED ON LL PORTIONS. BUILDING TO BE LTERED CCOMMODTE 2 DDITIONL UNITS 0m BUILDING LINE ELECTRICL BOX BUILDING TO BE LTERED CCOMMODTE 2 DDITIONL UNITS BUILDING TO BE LTERED CCOMMODTE CONFERENCE ROOM (00 SETS) PUMP STTION BUILDING TO BE LTERED TO INCLUDE N ENCLOSED DECK OF ±2m² - HOTEL PORTIONS (REMINDER & PTN ) RE POTENTILLY SECTION TITLE SCHEMES. PPROX. HIGH WTER MRK BSED ON ERIL IMGERY PLNNING CONTROL & HEIGHT TBLE BUILDING LINES MX. HEIGHT OF STRUCTURE HEIGHT CONTOUR (m) BOVE LINE FROM STREET RER SIDES CONTOUR WHICH STOREYS LINE MESURED 2 0m 0m 0m 0% 7 2 0m 0m 0m 0% 6. 2 (SPLIT) 0m 0m 0m 0% 6 2. 0m 0m 0m 0% 2 7. 2 6 0m 0m 0m 0% 2. 2 7 0m 0m 0m 70%.. 0m 0m 0m 70%.. 9 0m 0m 0m 70%.. 0 0m 0m 0m 70% 6 0m 0m 0m 70% 2 7 2 2 0m 0m 0m 70% 2 2 0m 0m 0m 70% 2. 2 0m 0m 0m 70%. 0m 0m 0m 70% 2 2 6 0m 0m 0m 90% 2 7. 2 7 0m 0m 0m 90% 2 7. 2 0m 0m 0m 90% 2 2 9 0m 0m 0m 90% 2 2 0m 0m 0m 90% 2. 2 2 0m 0m 0m 90% 2 2 22 0m 0m 0m 90% 2 0 2 2 0m 0m 0m 90% 2 2 2 0m 0m 0m 0% 2 2 2 0m 0m 0m 70% 2 2 0m 0m 0m 0% 2 2 0m 0m 0m 0% 2. 2 PTN NO. NOTE: BUILDING COVERGE MY NOT EXCEED THE MXIMUM COVERGE PERMITTED IN THE LND USE RESTRICTIONS COVERGE LND USE RESTRICTIONS REMINDER ; PRIMRY USE - LICENSED HOTEL,RECRETION,PRTMENT, RESTURNT,,PCKGE PLNT, RESORT,RODWY COVERGE - T MOST 0% HEIGHT - SEE NOTES SIDE & RER BUILDING LINE - 0m PRKING - BY PER UNIT DENSITY - MX. OF 0du/ha OWNERSHIP - FREEHOLD/SECTIONL TITLE PERMITTED PORTION ; PRIMRY USE -, PRTMENTS,RESORT COVERGE - T MOST 0% HEIGHT - SEE NOTES STREET,SIDE & RER BUILDING LINES ; 0m PRKING - BY PER UNIT DENSITY - MX. OF 97du/ha OWNERSHIP - FREEHOLD/SECTIONL TITLE PERMITTED PORTIONS 2-6,2,,: PRIMRY USE - COVERGE - T MOST 0% HEIGHT - PER HEIGHT TBLE SIDE & RER BUILDING LINE - 0m PRKING - 2 BYS PER UNIT OWNERSHIP - FREEHOLD SEPRTE TITLE PORTIONS 7 -,2 PRIMRY USE - COVERGE - T MOST 70% HEIGHT - PER HEIGHT TBLE SIDE & RER BUILDING LINE - 0m PRKING - 2 BYS PER UNIT OWNERSHIP - FREEHOLD SEPRTE TITLE PORTIONS 6,7: PRIMRY USE - COVERGE - T MOST 90% HEIGHT - PER HEIGHT TBLE SIDE & RER BUILDING LINE - 0m PRKING - 2 BYS PER UNIT OWNERSHIP - FREEHOLD SEPRTE TITLE PORTIONS -2: PRIMRY USE - COVERGE - T MOST 90% HEIGHT - PER HEIGHT TBLE SIDE & RER BUILDING LINE - 0m PRKING - 2 BYS PER UNIT OWNERSHIP - FREEHOLD SEPRTE TITLE SEGULLS BECH HOTEL & RESORT ON FRM 9, CENTNE LND USE LICENSED HOTEL,RECRETION, PRTMENTS,RESTURNT,,PCKGE PLNT,RESORT,RODWY, TENNIS COURT,PCKGE PLNT, PRTMENTS, RESORT x S PIPELINE TO PCKGE PLNT REMINDER 2 0. 2 0.67.0 2-6,2 6 0.2976 7-9 0. 6-2 0.7 2 0.00 SERVITUDE RIGHT OF WY IN FVOUR OF PTNS -6,7-2, SERVITUDE RIGHT OF WY IN FVOUR OF REMINDER & PTN RINWTER TNK 0.070 SERVICES RE 27 0 0.077 PRIVTE OPEN SPCE (NO DEVELOPMENT) PRIVTE RODWY/ PRKING TOTL Title PLN NO.:6 LND USE TBLE ZONING DTE: NOVEMBER Prepared by: EXISTING BUILDINGS TO BE RETINED EXISTING BUILDINGS TO BE DEMOLISHED POWERLINE TELKOM LINE (TO BE RELOCTED) 0.m CONTOURS BORDWLK 6 x S WITH DOUBLE GRGE 0 x S WITH SIE GRGE x S m BUILDING LINE STORMWTER OUTLETS SEWER PUMPSTTION QUEENSTOWN Ebden Road, Queenstown P.O. Box 699, Queenstown, 0 290 0 6 qtn@npmplanning.co.za PTN. NO. OF RE NO. UNITS (H) % 29,0 0.06 0 0.22 0 0.20 7 2. NO DEVELOPMENT RE CDSTRL BOUNDRIES RE S EXTRCTED FROM RECORDS T THE SURVEYOR GENERLS OFFICE LL CDSTRL BOUNDRIES RE TO BE CONFIRMED BY PROFESSIONL LND SURVEYOR CLIENT: SEGULLS TRDING COMPNY (PTY) LTD N PM - LEGEND Scale :000 NPM PLNNING www.npmplanning.co.za EST LONDON nderson Road, Berea, P.O. Box 9, Tecoma, 2 0 72 206 06 67 el@npmplanning.co.za PRKING SERVITUDES TO BE REGISTERED OVER PRKING BYS 6,-2,,6-60 ON THE REMINDER IN FVOUR OF PTN TOWN & REGIONL PLNNERS Rev No. 2. 2. 00 PORT ELIZBETH 9 Cape Road, Mill Park, P.O. Box 022, Linton Grange 0 7 60 0 7 00 pe@npmplanning.co.za SITE DEVELOPMENT PLN 0m 0m m 0m 0m 0m 60m 70m 0m BR SCLE WTER MINS FIRE HYDRNT SEWER MIN 0. 6.0.6.92 6.
..0 SEGULLS BECH HOTEL & RESORT ON FRM 9, CENTNE LND USE TBLE.2...2 2.96.0. BM 2.69 2.77..0 2.7 LND USE LICENSED HOTEL,RECRETION, PRTMENTS,RESTURNT,,PCKGE PLNT,RESORT,RODWY, TENNIS COURT,PCKGE PLNT ZONING PTN. NO. OF RE NO. UNITS (H) % REMINDER 2 0.. 0.7 BMJ 2.90.6.9.70 29 7 0.9.96.70 6.97 0.96 0.9 7. 7. PVT RD 0.72 BMK 7. 7..0 9.97 2 0 2.77 2.9 2.22 22.9.0 9 0.7.97 7 6. 2.7 7.6.9.72..72 6.7.02 22..6 2.2.76 7.92 7.9 7..7.96. 7.6 9...62 0.6.6.22.6 PVT RD 6.62 7.92 7.2 0.7 REMINDER (TO BECOME SECTIONL TITLE SCHEME) 29. 7. BMB 2 2.9..70. BMC PPROX. HIGH WTER MRK BSED ON ERIL IMGERY, PRTMENTS, 2 0.67. RESORT 2-6,2 6 0.2976 7-9 0.. 6-2 0.7 6.0 2 0.00.6 0.070 2. SERVICES RE 27 0 0.077.92 PRIVTE OPEN SPCE (NO DEVELOPMENT) PRIVTE RODWY/ PRKING TOTL 0.06 2. 29,0 0 0.22 6 0 0.20 -. 7 2. 00 SERVITUDE RIGHT OF WY IN FVOUR OF PTNS -6,7-2, SERVITUDE RIGHT OF WY IN FVOUR OF REMINDER & PTN LEGEND 9 0.m CONTOURS REGISTERED PROFESSIONL PLNNER BMH 7.60..0.2 2..6 7. 2 2.7 BMG.9. 27.9.6. 2.. 0.70 6. 29 7.0 2.. 22.6 2..0.9. 2 PVT RD 2. 2. 2 0.67 0.9 7 9.76 27.9.0 2.6 6.6 2.69.6 2.2 2.0 6.9 0.96.02.. 7.6 2..0.6.07 7.2 2..0 0. (TO BECOME SECTIONL TITLE SCHEME).22 2.. 2.6.7.2 2.6. 22.7.70 2.27 9.. BME BMF 0.9.7.2.0.2 6. 0.9 7.7 7.. BMD PTN / RE (m²) /0.67ha 2/7 /6 / / 6/0 7/0 /29 9/0 0/6 /99 2/76 /6 / /0 6/6 7/60 / 9/6 /2 2/76 22/2 2/ 2/ 2/0 /70 27/77 /6 29/92 0/79 /02 2/76 /296 REMINDER/0.ha Title PRKING SERVITUDES TO BE REGISTERED OVER PRKING BYS ON THE REMINDER IN FVOUR OF PTN DTE: NOVEMBER Prepared by: NOTES ------------ - NO FURTHER SUBDIVISIONS LLOWED ON LL PORTIONS. - HOTEL PORTIONS (REMINDER & PTN ) RE POTENTILLY SECTION TITLE SCHEMES. QUEENSTOWN Ebden Road, Queenstown P.O. Box 699, Queenstown, 0 290 0 6 qtn@npmplanning.co.za PLN NO.:6 CDSTRL BOUNDRIES RE S EXTRCTED FROM RECORDS T THE SURVEYOR GENERLS OFFICE LL CDSTRL BOUNDRIES RE TO BE CONFIRMED BY PROFESSIONL LND SURVEYOR CLIENT: SEGULLS TRDING COMPNY (PTY) LTD N PM Scale :20 NPM PLNNING TOWN & REGIONL PLNNERS www.npmplanning.co.za EST LONDON nderson Road, Berea, P.O. Box 9, Tecoma, 2 0 72 206 06 67 el@npmplanning.co.za PORT ELIZBETH 9 Cape Road, Mill Park, P.O. Box 022, Linton Grange 0 7 60 0 7 00 pe@npmplanning.co.za SITE DEVELOPMENT PLN Rev No 0m 0m m 0m 0m 0m 60m 70m 0m 0 D.B. POORTMN PR.PLN NOVEMBER DTE BR SCLE
Screen wall SEGULLS BECH RESORT TYPE () FRONT ELEVTION RER ELEVTION (PORTION ) TYPE () 00 2 0 0 900 0 000 0 2 000 2 0 2 6 0 6 2 PRKING SIE GRGE BTHROOM ISLND GS FIRE PLCE m High MSTER W.U W.T BBQ 2 9 0 900 0 0 2 2 9 0 6 2 SE VIEW SIE GRGE SECTION - 00 0 VERNDH 200 CONCEPT DRWINGS DRIVEWY VERNDH 00 RE : TYPE () : sqm 2 000 2 60 2 2 690 : sqm VERNDH : 27 sqm TOTL RE: 7sqm rchitecture & Project Facilitation
SEGULLS BECH RESORT TYPE (2) RER ELEVTION FRONT ELEVTION (PORTION ) TYPE (2) 00 00 2 0 2 0 2 PRKING 2 90 0 0 900 0 990 0 0 2 000 2 0 0 2 000 2 2 6 0 000 DRIVEWY 2 DESK PLSM 60 0 SIE GRGE BTHROOM 0 DINING RE 0 MSTER 70 2 BBQ W.T PTIO PLNTER 0 672 2 2 672 000 SE VIEW 60x2 RE : TYPE (2) : sqm : 22 sqm PTIO : 2 sqm 60x2 TOTL RE: 6sqm MSTER SECTION - 0 VERNDH 200 CONCEPT DRWINGS 2 60 0 00 00 00 0 90 0 2 rchitecture & Project Facilitation
Feature / Screen wall SEGULLS BECH RESORT TYPE B FRONT ELEVTION RER ELEVTION (PORTION ) TYPE B 00 60 2 0 2 20 2 WSH YRD PRKING GTE 2 62 60 0 0 0 0 0 0 2 GLLEY DOUBLE GRGE DRIVEWY DINING RE 2000 VERNDH Tiles BTHROOM MSTER 2 0 2 60 0 0 0 0 0 0 2 B.C F.P W.T BBQ 62 770 PLSM DESK PLSM SE VIEW 2 20 0 200 2 2 00 0 900 00 0 00 2 200 0 VERNDH 00 SECTION - RE : TYPE B : sqm : sqm VERNDH : sqm BLCONY: sqm TOTL RE: 22sqm DINING RE CONCEPT DRWINGS rchitecture & Project Facilitation
SEGULLS BECH RESORT TYPE C FRONT ELEVTION RER ELEVTION TYPE C 2 STOREY 070 (PORTION 22) 00 2 70 0 70 0 70 2 2 000 0 00 0 00 0 000 2 00 W.T BTHROOM MSTER PLSM DINING RE 2 70 2990 900 00 0 0 2 2 6660 0 790 2 SE VIEW RE : TYPE C DINING RE BLCONY SECTION - 0 200 CONCEPT DRWINGS 00 BBQ BLCONY : sqm 2 00 2 070 00 BLCONY : 9 sqm TOTL RE: 7sqm rchitecture & Project Facilitation