Section 9.5. Design of Areas, Spaces and Doorways

Similar documents
Secondary Suites Changes between the 2006 ABC and the 2014 ABC Requirements

CHAPTER 4 LIGHT, VENTILATION & OCCUPANCY LIMITATIONS

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

CITY OF MOUNT PLEASANT ORDINANCE NO. 1017

Ontario s 2012 Building Code Barrier-Free Design Amendments Ontario Regulation 332/12 Amended by O. Regs. 368/13 and 191/14

NEW ACCESSIBILITY CHANGES

ADAPTABLE DESIGN GUIDELINES

Attic Floor Bedrooms 1 & 2 Family Dwellings

Arlington County. Smart Choice Homes. Arlington County. Homes for all of us. Homes for a lifetime. Home

BUILDING CODE COMMISSION

Regulation Outline. Under section 59 of the Community Planning Act, the Lieutenant-Governor in Council makes the following Regulation:

Schedule C Barrier-Free Design

Understanding Accessibility Features to Meet Housing Needs

Understanding Accessibility Features to Meet Housing Needs

*Figuring Square Footage

Copyright 2013, Queen s Printer for Ontario

Vestibule Requirement Intent

APPLICATION OF SECTION 3.8 OF THE 2012 ONTARIO BUILDING CODE FOR: BARRIER-FREE AUDIT OF SENECA COLLEGE NEWNHAM CAMPUS TORONTO, ONTARIO

THIS CHECKLIST HAS BEEN AMENDED TO INCLUDE ONLY LEVEL ONE CRITERIA AS REQUESTED BY TIR REAL PROPERTY. As such it does not form a complete Checklist.

Residential Accessible, Type A, and Type B Dwelling Unit Requirements 2012 International Building Code and 2009 ICC/ANSI A117.1

RM-7, RM-7N and RM-7AN Districts Schedules

BUILDING CODE COMMISSION

RT-11 and RT-11N Districts Schedules

2014 OSSC CHAPTER 10 - MEANS OF EGRESS TABLE OF CONTENTS

Stark HS. Housing Solutions. By:

RM-8 and RM-8N Districts Schedule

Presentation By. Chris Poujol. Jeffery Rodriguez. James Rigley

Regional District of Nanaimo Secondary Suite Program

Duplex for rent in LUXEMBOURG-MERL

2014 Vancouver Building By-Law

City of Vancouver Zoning and Development By-law Planning, Urban Design and Sustainability Department

West 1st Avenue By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

BUILDING CODE INTERPRETATION

2018 CSBC / 2018 CSFSC Part III. Chapter #10. Means of Egress. Table of Contents. Based on the 2015 IBC and the 2015 IFC.

CHAPTER 10 ARTICLE II DIVISION 2: MINIMUM STANDARDS

West Hastings Street By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

SCHEDULE A TO BY-LAW NUMBER (Amended by By-law ) CLASSES OF PERMITS AND PERMIT FEES

RM-1 and RM-1N Districts Schedule

1200 Alberni Street By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

7 Section 1. PURPOSE. The purpose of this Code is to provide minimum

OBTAINING A CERTIFICATE OF OCCUPANCY FOR UNAPPROVED DWELLING UNITS

(2) Determining Occupant Loads for the Operation of a Building (The Alberta Fire Code)

1133 West Georgia Street By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

The New NYC Building Code Chapter 10 Means of Egress. New York City Department of Buildings. Technical Affairs. Fatma M. Amer, P.E.

Oakdale, Sully Road Penarth CF64 2TQ. 665,000 Freehold

DEPARTMENT OF DEVELOPMENT SERVICES ACCESSIBILITY CHECK LIST FOR MULTI-FAMILY RESIDENTIAL BUILDINGS

HOUSING CODE CHECKLIST FOR RENTAL INSPECTIONS

TEXAS. Downloaded

Tiny House on Wheels A Tiny House

ACCESSORY DWELLING UNITS

BUILDING CODE COMMISSION

The New NYC Building Code Chapter 11 Accessibility. New York City Department of Buildings. Technical Affairs. Keith Wen, R.A. Copyright Materials

2012 Texas Accessibility Standards Reference Guide for changes to the code

3. Miscellaneous Instructions and Definitions.

ACCESSORY DWELLING UNITS

BUILDING CODE COMMISSION

A Guide to Secondary Suites

MANDATORY BUILDING STANDARDS FOR ADAPTABLE HOUSING

1185, Rue du Sphinx, Fleurimont (Sherbrooke)

CAS PAR. Comprehensive Assessment and Solution Process For Aging Residents INTRODUCTION MATERIALS NEEDED 1 CASPAR

1003 Pacific Street By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

City of Vancouver Zoning and Development By-law Planning, Urban Design and Sustainability Department

DESCRIPTION OF LANDLORD'S WORK & TENANT'S WORK

A Contemporary Arts & Culture Neighbourhood

q/., S Lt _ _.._--.

E1-12: Final Decision AS

RM 4 and RM 4N Districts Schedule

About Naya. Location Located in Jal el Dib, Naya s proximity with the capital and the rest of the country s beating hearts

RT-5 and RT-5N Districts Schedule

Contemporary villas Panoramic view 3 minutes from Bonita Beach

Offers In Region Of 495,000 Lower Calebs Barn, Cawder Lane, Skipton, BD23 2TD

BUILDING CODE COMMISSION

A By-law to amend Zoning and Development By-law No regarding Laneway Houses

RT-8 District Schedule

LEGEND. A Apartments. T Townhouses

CHAPTER 726 Rental Dwelling Registration DEFINITIONS.

BUILDING GUIDELINE MEASUREMENT. Appraisal Institute of Canada 403 ~ 200 Catherine Street Ottawa, Ontario K2P 2K9

695,000 St Sampson. Local Market. Onn Inn And 2 Lillington Camp Du Roi. lovellsproperty.com Telephone

ORDINANCE NO

DESIGN PRIORITIES. Avenues for Homeless Youth. Charrette Goals AVENUES FOR HOMELESS YOUTH

380 Piccadilly Avenue - Wellington Village

RT-2 District Schedule

RM-11 and RM-11N Districts Schedule

Redacre, Petitor Road 894,950

West Pender Street By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

Renders Illustrative purposes only. PREMIUM PARK FRONT TOWN HOMES

For more information contact Julia Wilson

BUILDING SPECIFICATIONS

CD-1 (264) 101 Terminal Avenue By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

RM-5, RM-5A, RM-5B, RM-5C and RM-5D Districts Schedule

RT-7 District Schedule

Residential Square Footage Guidelines

Facilities providing accommodation for the public (e.g. Hotels, hostels, guesthouses, self catering apartments).

City of Vancouver Zoning and Development By-law Planning, Urban Design and Sustainability Department

uovo style the residences feature 9ft high smooth ceilings for levels ft high smooth ceilings for levels 7-11

Residential Single Detached Dwelling Districts (RS)

ERRATA AND REVISIONS MEASURES FOR FIRE SAFETY IN HIGH BUILDINGS

FLOOR PLANS. 62 GERMANY ISLAND - The Heart of Europe GERMANY ISLAND - The Heart of Europe 63

There is no Communal Open Space (COS) requirement for condominium developments.

Type A-g 1-Bedroom 66 sq m / 710 sq ft #01-01

Transcription:

f):.-"> ~Ontario 2012 Building Code Compendium 9.5.1.5. 9.4.4.5. Reserved 9.4.4.6. Walls Supporting Drained Earth (See Appendix A.) Except where constructed in accordance with Section 9.15., walls supporting drained eartll shall be designed, (a) for a pressure equivalent to that exerted by a fluid with a density of not less than 480 kg/m' and a depth equal to that of the retained earth. or (b) in accordance with Section 4.2. so as to be able to resist the loads and effects described in Article 4.1.2.1. (2) Walls supporting other than drained earth shall be designed, (a) for the pressure described in Clause (a) plus the flui d pressure of the surcharge, or (b) in accordance with Section 4.2. so as to be able to resist the loads and effects described in Article 4. 1.2. 1. Section 9.5. Design of Areas, Spaces and Doorways 9.5.1. General 9.5.1.1. Application Except as otherwise specified in this Part, this Section applies only to dwelling IInils that are intended for use on a continuing or year-round basis as the principal residence of the occupant. 9.5.1.2. Method of Measurement (1) Except as otherwise specified in this Part, the areas, dimensions and heights of rooms or spaces shall be measured between finished wall surfaces and between finished floor and ceiling surfaces. 9.5.1.3. Floor Areas Minimum floor areas specified in this Section do not include closets or built-in bedroom cabinets unless otherwise indicated. 9.5.1.4. Combination Rooms (See Appendix A.) Two or more areas may be considered as a combination room if the opening between the areas occupies the larger of 3 m 2 or 40% or more of the wall measured on the side of the dependent area. (2) Where the dependent area is a bedroom, direct passage shall be provided between the two areas. (3) The opening required in Sentence shall not contain doors or windows. 9.5.1.5. Lesser Areas and Dimensions Areas of rooms and spaces are pennitted to be less than required in this Section provided it can be shown that the rooms and spaces are adequate for their intended use, such as by the provision ofbuiit-in furniture to compensate for reduced sizes. Effective Date:.January 1, 2015 Issued January 1,2014 15

/'~ 9.5.2.1. 2012 Building Code Compendium t?ontario 9.5.2. Barrier-Free Design 9.5.2.1. General (1) Except as provided in Sentence (2) and Article 3.8.1 I., every building shall be designed in conformance with Section 3.8. (2) The requirements of Section 3.8. need not be provided for houses, including semi-detached houses, duplexes, triplexes, town houses, row houses and boarding or rooming houses with fewer tjlall eight boarders or roomers. 9.5.2.2. Protection on Floor Areas With a Barrier-Free Path of Travel. (1) Where a barrier-free path of travel required in Article 9.5.2.1. is provided to any storey above theftrsl slorey, the requirements in Article 3.3.1.7. shall apply. 9.5.2.3. Stud Wall Reinforcement r 4 (1) If wood wall studs or sheet steel wall studs enclose the main bathroom in a dwelling unit, reinforcement shall be installed to pennit the future installation of the following: (a) for a water closet, a grab bar described in Clauses 3.8.3.8.(3)(a) and a grab bar described in Clause 3.8.3.8.(3)(c), (b) for a shower, a grab bar described in Clause 3.8.3.13.(2)(1), and (e) for a bathtub, a grab bar described in Clause 3.8.3.13.(4)(c). (See Appendix A.) 9.5.3. Ceiling Heights 9.5.3.1. Ceiling Heights of Rooms or Spaces (1) The ceiling heights of rooms or spaces in residential occupancies and live/work units shall conform to Table 9.5.3.1. (2) Areas in rooms or spcces over which ceiling height is not less than the minimum specified in Table 9.5.3.1. shall be contiguous with the entry or entries to those rooms or spaces. 16 Issued January 1,2014 Effective Date: January 1, 2015

POntario 2012 Building Code Compendium 9.5.5.1. Room or Space Living room or space, dining room or space, kitchen or kitchen space Bedroom or bedroom space Basement space Bathroom, water closet room or laundry area above grade Passage, hall or main entrance vestibule and finished rooms not specifically mentioned above Table 9.5.3.1. Room Ceiling Heights Forming Pari of Sentences 9.5.3.1.(1) and (2) Minimum HeightsC') 2 300 mm over at least 75% of the required floor area with a clear height of 2100 mm at any point over the required area 2 300 mm over at least 50% of the required area or 2 100 mm over all of the required floor area. Any pari of the floor having a clear height of less than 1400 mm shall not be considered in computing the required floor area 2100 mm over at least 75% of the basement area except that under beams and ducts the clearance is permitted to be reduced to 1 950 mm 2100 mm in any area where a person would normally be in a standing position 2100 mm Column 1 2 Notes to Table 9.5.3.1.: (1) Area of the space shall be measured at floor level. 9.5.3.2. Mezzanines The ceiling height above and below a mezzanine floor assembly in all occupancies shall be not less than 2100 mm. 9.5.3.3. Storage Garages The clear height in a storage garage shall be not less than 2 000 mm. 9.5.4. Living Rooms or Spaces Within Dwelling Units 9.5.4.1. Areas of Living Rooms and Spaces Living areas within dwelling units, either as separate rooms or in combination with other spaces, shall have an area not less than 13.5 m'. (2) Where the area of a living space is combined with a kitchen and dining area, the living area alone in a dwelling unit that contains sleeping accommodation for not more than two persons shall be not tess than t t m'. 9.5.5. Dining Rooms or Spaces Within Dwelling Units 9.5.5.1. Area of Dining Rooms or Spaces ~ A dining space in combination with other space shall have an area of not less than 3.25 m'. (2) Dining rooms not combined with other space shall have a minimum area of 7 m'. 17

fl'-:> 9.5.6.1. 2012 Building Code Compendium V Ontario 9.5.6. Kitchens Within Dwelling Units 9.5.6.1. Kitchen Areas (1) Kitchen areas within dwelling units either separate from or in combination with other spaces, shall have an area of not less than 4.2 m' including the area occupied by the base cabinets, except that in dwelling units containing sleeping accommodation for not more than two persons, the minimum area shall be 3.7 m 2. 9.5.7. Bedrooms or Spaces in Dwelling Units and Dormitories 9.5.7.1. Areas of Bedrooms (1) Except as provided in Articles 9.5.7.2. and 9.5.7.3., bedrooms in dwelling units shall have an area not less than 7 m' where built-in cabinets are not provided and not less than 6 m' where built-in cabinets are provided. 9.5.7.2. Areas of Master Bedrooms (1) Except as provided in Article 9.5.7.3., at least one bedroom in every dwelling unit shall have an area of not less than 9.8 m' where built-in cabinets are not provided and not less than 8.8 m' where built-in cabinets are provided. 9.5.7.3. Areas of Combination Bedrooms (1) Bedroom spaces in combination with other spaces in dwelling units shall have an area not less than 4.2 m'. 9.5.7.4. Areas of Other Sleeping Rooms (1) Sleeping rooms other than in dwelling units shall have an area not less than 7 m' per person for single occupancy and 4.6 m' per person for multiple occupancy. 9.5.7.5. Recreational Camps (1) Recreational camps shall have an area in the sleeping quarters of at least 3.72 m' per camper or, if double or triple tier bunk units are used, 2.79 m 2 per camper. 9.5.7.6. Camps for Housing Workers (1) A camp for housing of workers shall have a minimum area of3.72 m' per employee in every room used for sleeping purposes. 9.S.S. Combined Spaces 9.5.8.1. Combined Living, Dining, Bedroom and Kitchen Spaces (1) Despite Subsections 9.5.4. to 9.5.7., where living, dining, bedroom and kitchen spaces are combined in a dwelling unit that contains sleeping accommodation for not more than two persons, the area of the combined spaces shall be not less than 13.5 m'. 18

POntariO 2012 Building Code Compendium 9.5.11.1. 9.5.9. Bathrooms and Water Closet Rooms 9.5.9.1. Space to Accommodate Fixtures (\) In every dwelling unit an enclosed space of sufficient size shall be provided to accommodate a water closet, lavatory and bathtub or shower stall. 9.5.9.2. Doors to Rooms Containing Water Closets (\) A door shall be provided to each room containing a water closet within a dwelling unit. 9.5.10. Hallways 9.5.10.1. Hallway Width (\) The unobstructed width ofa hallway within a dwelling unit shall be not less than 860 mm, except that the hallway width is permitted to be 710 mm, where, (a) there are only bedrooms and bathrooms at the end of the hallway furthest from the living area, and (b) a second exit is provided, (i) in the hallway near the end furthest from the living area, or (ii) in each bedroom served by the hallway. 9.5.11. Doorway Sizes 9.5.11.1. Doorway Opening Sizes (\) Except as provided in Articles 9.5.11.3., 9.9.6.2. and 9.9.6.3., doorway openings within dwelling units shall be designed to accommodate at least the door sizes in Table 9.5.11.1. for swing-type doors or folding doors. Table 9.5.11.1. Minimum Door Sizes Forming Part of Sentence 9.5.11.1.(1) Dwelling unff (required entrance) Vestibule or entrance hall At Entrance to: Minimum Width, mm Stairs to a floor level that contains a finished space All doors in at least one line of passage from the exterior to the basement 810 Utility rooms Walk-in doset 610 Bathroom, water closet room, shower room!') 610 Rooms located off hallways that are permitted to be 710 mm wide 610 Rooms not mentioned above, exterior balconies 760 Column 1 2 810 Minimum Height, mm 3 Notes to Table 9.5.11.1.:.----.. (1) See Article 9.5.11.3. 19

9.5.11.2. 2012 Building Code Compendium f):.-, VOntario 9.5.11.2. Doors to Public Water Closet Rooms Doors to public water closet rooms shall be not less than 810 mm wide and 2 030 mm high. 9.5.11.3. Doors to Bathrooms Where a barrier-free path of travel conforming to Section 3.8. is provided into a suite of residential occupancy and where a bathroom within the suite is at the level of the suite entrance door, the doorway to such bathroom and to each bedroom at the same level as such bathroom shall have, when the door is in the open position, a clear width of not less than, (a) 760 mm where the door is served by a corridor or space not less than I 060 mm wide, and (b) 8 10 mm where the door is served by a corridor or space less than I 060 mm wide. ~ Section 9.6. Glass 9.6.1. General 9.6.1.1. Application (a) (b) This Section ap plies to, glass in, (i) interior windows and interior doors and their sidelights, (ii) clothes closets, (i ii) site-built exterior windows, doors and skylights, (iv) shower or bathtub enclosures, (v) glazed panels and partitions, and the protection of glass. 9.6.1.2. Material Standards for Glass (a) (b) (c) (d) (e) (g) (h) Glass shall conform to, CAN/CGSB-1 2. I-M, "Tempered or Laminated Safety Glass," CAN/CGSB-1 2.2-M, " Flat, Clear Sheet Glass", CAN/CGSB-1 2.3-M, "Flat, Clear Float Glass", CAN/CGSB-12.4-M, "Heat-Absorbing Glass," CAN/CGSB-12.8, "Insulating Glass Units", CAN/CGSB-1 2.1 O-M, "Glass, Light and Heat Reflecting", CAN/CGSB-1 2.II-M, "Wired Safety Glass", or ASTM E2190, " Insu lating Glass Unit Performance and Evaluation". (2) Mirrored glass doors are permitted to be used only at the entrance to clothes closets and shall conform to the requirements ofcan/cgsb-82.6-m, " Doors, Mirrored Glass, Sliding or Folding, Wardrobe". (See Appendix A.) (3) Mirrored glass doors reinforced with a film backing shall meet the impact resistance requirements specified in CAN/CGSB-1 2.5-M, " Mirrors, Silvered". 9.6.1.3. Structural Sufficiency of Glass Glass shall be designed in conformance with CAN/CGSB-1 2.20-M, "Structural Design of Glass for Bui ldings". (See Appendix A.) 20

POntario 2012 Building Code Compendium Div. B A 9.6.1.3.(1) (5) Swinton, M.C., Brown, W.C., and Chown, G.A. Controlling the Transfer of Heat, Air and Moisture through the Building Envelope. Small Buildings - Technology in Transition, Building Science Insight '90, Institute for Research in Construction, National Research Council Canada, Ottawa, 1990. A-9.4.4.6. and A-9.1S.1.1. Loads on Foundations. The prescriptive solutions provided in Part 9 relating to footings and foundation walls only account for the loads imposed by drained earth. Drained earth is assumed to exert a load equivalent to the load that would be exerted by a fluid with a density of 480 kg/m'. The prescriptive solutions do not account for surcharges from saturated soil or additional loads from heavy objects located adjacent to the building. Where such surcharges are expected, the footings and foundation walls must be designed and constructed according to Part 4. A-9.S.1.4. Combination Rooms. tf a room draws natural light and natural ventilation from another area, the opening between the two areas must be large enough to effectively provide sufficient light and air. This is why a minimum opening of3 m 2 is required, or the equivalent of the area of a set of double doors. The effectiveness of the transfer of light and air also depends on the size of the transfer opening in relation to the size of the dependent room; in measuring the area of the wall separating the two areas, the whole wall on the side of the dependent room should be considered, not taking into account offsets that may be in the surface of the wall. The opening does not necessarily have to be in the fonn of a doorway; it may be an opening at eye level However, if the dependent area is a bedroom, provision must be made for the escape window required by Article 9.7.1.3. to fulfill its safety function. This is why a direct passage is required between the bedroom and the other area; the equivalent of at least a doorway is therefore required for direct passage be tween the two areas. e'.1 A-9.S.2.3.(1) Stud Wall Reinforcement. ~ This provision for future attachment of grab bars in the main bathroom of a residential occupancy including houses requires the installation of suitable blocking in the stud wall. Senlence 9.31.2.3.( I) specifies the required load resistance. Also, see Appendix Note A-3.3.4.9.. A-9.6.1.2.(2) Mirrored Glass Doors. Standard CAN/CGS8-82.6 covers mirrored glass doors for use on reach-in closets. It specifies that such doors are not to be used for walk-in closets. A-9.6.1.3.(1) Maximum Glass Area. Tables A-9.6.1.3.A. to A-9.6.1.3.F. may be used to select glass thickness for windows subject to the following conditions: The building has an essentially unifonn distribution of paths for air leakage, including operable openings, but no large openings that would permit wind gusts to rapidly enter the building, e.g., loading or garage doors. The building has a height from grade to the uppermost roof of 12 m or less, and is located in a built-up area, no less than 120 In away from the boundary between this area and open terrain. (Where this criterion is not met, see Tables A-9.6.1.3.D, to A-9.6.1.3.F., which apply to buildings located on open terrain.) The building is not in an exceptionally exposed location such as a hilltop. These six Tables are based on CAN/CGS8-12.20-M and the wind load provisions in Article 4. 1.7.1. The maximum glass area values given in these Tables are intended to be equal to or smaller than those that would be determined using the standard and wind load provisions directly to design for each individual case. Appendix A Volume 2 Effective Date: January 1, 2015 Page 109 Issued January 1,2014