PLANNING APPLICATION (REVISION 2.1)
|
|
- Justina Baldwin
- 5 years ago
- Views:
Transcription
1 (REVISION )
2 RT DF SCHEMATIC SITE GRADING PLAN SCHEMATIC SITE GRADING PLAN 1" = 10' 1 C1
3 RT DF SCHEMATIC SITE UTILITY PLAN SCHEMATIC SITE UTILITY PLAN 1" = 10' 1 C2
4 RT DF SCHEMATIC SITE STORM WATER QUALITY PLAN SCHEMATIC SITE STORM WATER QUALITY PLAN 1" = 10' 1 C
5 ± ± LOW-EMITTING / FUEL-EFFICIENT VEHICLE NO PARKING KEEP CLEAR DO NOT BLOCK FIRE STATION 1110 IRON POINT ROAD, SUITE 200 FOLSOM CALIFORNIA TEL: STOP KEEP CLEAR BOREL AVE ± ± SHAFTER ST L I CENSED ARCH BILL LOUIE I TECT STOP S T A T E 05/1/19 OF I CA L I A FORN BOREL AVE STOP KWC BL AS SHOWN SITE AREA: 17,854 S.F. (0.41 AC) TOTAL BUILDING AREA: 4,950 S.F. (,195 S.F. 1ST FLOOR + 1,755 S.F. 2ND FLOOR) PROPOSED SITE PLAN 1" = 10'-0" PROPOSED SITE PLAN A1
6 1110 IRON POINT ROAD, SUITE 200 FOLSOM CALIFORNIA TEL: BARNESON AVE LOW-EMITTING / FUEL-EFFICIENT VEHICLE NO PARKING SHAFTER ST STOP STOP L I CENSED ARCH BILL LOUIE I TECT BOREL AVE STOP S T A T E 05/1/19 OF I CA L I A FORN KWC BL AS SHOWN SITE AREA: 17,854 S.F. (0.41 AC) TOTAL BUILDING AREA: 4,950 S.F. (,195 S.F. 1ST FLOOR + 1,755 S.F. 2ND FLOOR) PROPOSED SITE PLAN - EXTENDED 1" = 0'-0" PROPOSED SITE PLAN - EXTENDED A1.1
7 1110 IRON POINT ROAD, SUITE 200 FOLSOM CALIFORNIA TEL: BO RE L AV E SED ARCH I T EN IA 05/1/19 T RN STA E BILL LOUIE T EC L IC SHAFTER ST OF CA L I FO BOREL AVE KWC BL AS SHOWN EXISTING SITE PLAN EXISTING SITE PLAN 1" = 10'-0" A1E
8 1110 IRON POINT ROAD, SUITE 200 FOLSOM CALIFORNIA TEL: L I CENSED ARCH BILL LOUIE I TECT S T A T E 05/1/19 OF I CA L I A FORN KWC BL N.T.S. EXISTING SITE PHOTOS EXISTING SITE PHOTOS N.T.S. A1P
9 SPACE USE AND OCCUPANT LOAD SCHEDULE (BASED ON 2016 CBC TABLE ) EXITING ANALYSIS (BASED ON 2016 CBC, SECTION ) LOBBY, 15 S.F./OCC. OFFICE, 100 S.F./OCC. STORAGE, 00 S.F./OCC. APPARATUS ROOM, 200 S.F./OCC. DORMITORY, 1 BED / OCC. TURN-OUT LOCKER ROOM, 50 S.F./OCC. BATHROOM, 100 S.F./OCC. EXERCISE ROOM, 50 S.F./OCC. ELECTRICAL/MECH. ROOM, 00 S.F./OCC. DINING ROOM, 15 S.F./OCC. KITCHEN, 100 S.F./OCC. DAY ROOM, 15 S.F./OCC. RESTROOM, 100 S.F./OCC. LAUNDRY ROOM, 100 S.F./OCC. AREA IDENTITY 100 SPACE USE - REFER TO SCHEDULE FLOOR AREA IN SQUARE FEET OCCUPANT LOAD NOTE: * (ASTERISK) INDICATES ACCESSORY USE AREA EXCLUDED FROM COMPUTING OCCUPANT LOAD OF BUILDING PATH OF EGRESS (NUMBER INDICATES OCCUPANT LOAD) EXIT SIGN (PER 2016 CBC, SECTION 101) 1-HR FIRE PARTITION PROPOSED TOTAL OCCUPANTS: 72 EGRESS WIDTH REQUIRED: 14.4 INCH (1) EGRESS WIDTH PROVIDED: 48 INCH MIN. WIDTH HALLWAYS / STAIRWAYS 6 INCH MIN. WIDTH DOORWAYS MAX. EGRESS TRAVEL DISTANCE: 90 FEET (CAPTAIN'S BATH TO 1ST FLOOR LOBBY) 1. EGRESS WIDTH: 0.2 INCH PER OCCUPANT (2016 CBC, SECTION ) CODE ANALYSIS NOTES 1. THE CODE ANALYSIS IS BASED ON A NONSEPARATED OCCUPANCIES PER 2016 CBC, SECTION NO SEPARATION IS REQUIRED BETWEEN OCCUPANCIES PER 2016 CBC, SECTION FIRE PARTITIONS ARE PROVIDED FOR THE WALLS SEPARATING SLEEPING UNITS IN THE SAME BUILDING AND WALLS SEPARATING DWELLING OR SLEEPING UNITS FROM OTHER OCCUPANCIES (B) AND (S-2) CONTIGUOUS TO THEM PER 2016 CBC, SECTION AND SECTION EXCEPTION 2.. 1/2 HOUR HORIZONTAL SEPARATIONS HAVE BEEN PROVIDED FOR THE PROPOSED FIRE STATION BUILDING. PER THE EXCEPTION LISTED UNDER 2016 CBC, SECTION 711.., HORIZONTAL ASSEMBLY SHALL BE NOT LESS THAN 1/2 HOUR FIRE-RESISTANCE-RATED CONSTRUCTION FOR TYPE VB CONSTRUCTION EQUIPPED THROUGHOUT WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION THE CONSTRUCTION SUPPORTING THE HORIZONTAL ASSEMBLY AT THE SEPARATIONS OF DWELLING UNITS AND SLEEPING UNITS IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED FOR BUILDINGS OF TYPE VB CONSTRUCTION PER 2016 CBC, SECTION EXCEPTION THERE WILL BE NO HAZARDOUS MATERIALS STORED OR USED WITHIN BUILDINGS THAT EXCEED 2016 CBC, TABLES 07.1(1) AND 07.1(2) 6. INTERIOR FINISH SHALL COMPLY WITH 2016 CBC, SECTION 80.1 FLAME SPREAD PROVISIONS. 7. RATED CORRIDOR IS NOT REQUIRED PER 2016 CBC, TABLE : CORRIDOR FIRE-RESISTANCE RATING FOR OCCUPANCY GROUPS B AND S WITH AUTOMATIC FIRE SPRINKLER SYSTEM IS 0 HOURS AND PER 2016 CBC, SECTION , EXCEPTION 2 - A FIRE RESISTANCE RATING IS NOT REQUIRED FOR CORRIDORS CONTAINED WITHIN A DWELLING UNIT OR SLEEPING UNIT IN AN OCCUPANCY IN GROUP R EXITING PLANS /2" = 1'-0" IRON POINT ROAD, SUITE 200 FOLSOM CALIFORNIA TEL: L I CENSED ARCH BILL LOUIE I TECT S T A T E 05/1/19 OF I CA L I A FORN KWC BL AS SHOWN PROPOSED FLOOR PLANS TOTAL BUILDING AREA: 4,950 S.F. (,195 S.F. 1ST FLOOR + 1,755 S.F. 2ND FLOOR) PROPOSED FLOOR PLANS 1/8" = 1'-0" A2
10 (REVISION )
11 1110 IRON POINT ROAD, SUITE 200 FOLSOM CALIFORNIA TEL: L I CENSED ARCH BILL LOUIE I TECT S T A T E 05/1/19 OF I CA L I A FORN KWC BL AS SHOWN PROPOSED BUILDING SECTIONS PROPOSED BUILDING SECTIONS 1/8" = 1'-0" A4
12 (REVISION )
13 SCHEMATIC PLANTING PLAN L1
14 LOW-EMITTING / FUEL-EFFICIENT VEHICLE /12/2018 (REVISION 1) CBF RES CBF E1.1P PHOTOMETRIC SITE PLAN PHOTOMETRIC SITE PLAN 1 1" = 10'-0" N
2012 IBC Mixed Occupancies
Accreditation 2012 IBC Mixed Occupancies Based on the 2012 International Building Code (IBC ) The International Code Council has been accredited as an Authorized Provider by the International Association
More informationPP Course # Instructor Information. Patrick Vandergriff 35 Cottonwood Canyon Road La Luz, NM
Instructor Information PP Course #15788 Patrick Vandergriff 35 Cottonwood Canyon Road La Luz, NM 88337 1-575-430-8752 pvandergriff@codeconsult.org 1 Detailing of Mixed Occupancy Structures within the 2018
More informationDiscuss the history of fires that resulted in much of the development of codes related to means of egress. Review mean of egress terminology
Discuss the history of fires that resulted in much of the development of codes related to means of egress Review mean of egress terminology Discuss 8 Elements to an Effective Means of Egress. Modern code
More informationSecondary Suites Changes between the 2006 ABC and the 2014 ABC Requirements
Secondary Suites Changes between the 2006 ABC and the 2014 ABC Requirements Alberta Building Code 2006 Alberta Building Code 2014 Change 9.37.2. Construction 9.37.2.1. Height of Rooms and Spaces 1) The
More informationThe New NYC Building Code Chapter 10 Means of Egress. New York City Department of Buildings. Technical Affairs. Fatma M. Amer, P.E.
The New NYC Building Code Chapter 10 Means of Egress New York City Department of Buildings Technical Affairs Fatma M. Amer, P.E. Copyright Materials This presentation is protected by US and International
More informationMIXED-USE RETAIL MIDWAY/SPORTS ARENA DISTRICT KEMPER STREET, SAN DIEGO. Across the street from:
MIXED-USE RETAIL MIDWAY/SPORTS ARENA DISTRICT -7 KEMPER STREET, SAN DIEGO Across the street from: PROPERTY HIGHLIGHTS ACROSS THE STREET FROM POINT LOMA PLAZA Mixed-use luxury apartment building with 81
More informationBUILDING CODE COMMISSION
Ruling No. 09-03-1215 Application No. B-2009-01 BUILDING CODE COMMISSION IN THE MATTER OF Subsection 24(1) of the Building Code Act, S.O. 1992, c. 23, as amended. AND IN THE MATTER OF with Sentences 3.3.1.3.(9)
More informationFAIRFIELD INN & SUITES
Developer New Age Properties Group, LLC 9 West th Street Washington, NC 889.90.00 Attn: Manfred Alligood Set # of Total Sets Contains: Civil Drawing Architectural Drawings See Set # for: Structural Drawings
More informationThe New NYC Building Code Chapter 11 Accessibility. New York City Department of Buildings. Technical Affairs. Keith Wen, R.A. Copyright Materials
The New NYC Building Code Chapter 11 Accessibility New York City Department of Buildings Technical Affairs Keith Wen, R.A. Copyright Materials This presentation is protected by US and International Copyright
More informationCalifornia Building Code
Height and Area Provisions in the California Building Code Dennis Richardson, P.E., C.B.O., CASp Western Coast Manager American Wood Council The Wood Products Council is a Registered Provider with The
More informationBUILDING CODE COMMISSION
Ruling No. 08-03-1177 Application No. 2007-26 BUILDING CODE COMMISSION IN THE MATTER OF Subsection 24(1) of the Building Code Act, S.O. 1992, c. 23, as amended. AND IN THE MATTER OF Articles 3.4.4.1.,
More informationE1-12: Final Decision AS
BCAC COMPILATION OF GROUP A E1-12: Final Decision AS 202, 1006 (New), 1007 (New), 1014.3, 1015, 1020.1, 1021 (IFC [B] 1006 (New), 1007 (New), 1014.3, 1015, 1020.1, 1021) Proponent: Charles S. Bajnai, Chesterfield
More information2018 CSBC / 2018 CSFSC Part III. Chapter #10. Means of Egress. Table of Contents. Based on the 2015 IBC and the 2015 IFC.
2018 CSBC / 2018 CSFSC Part III. Chapter #10. Means of Egress. Table of Contents. Based on the 2015 IBC and the 2015 IFC. October 23, 2018 Section 1001. Administration. See Section 107.2.3 for Egress Drawing
More informationCITY OF MOUNT PLEASANT ORDINANCE NO. 1017
CITY OF MOUNT PLEASANT ORDINANCE NO. 1017 AN ORDINANCE TO AMEND SECTIONS 152.004 AND 152.007 OF THE CODE OF ORDINANCES FOR THE CITY OF MOUNT PLEASANT TO ADOPT PROVISIONS OF THE 2012 INTERNATIONAL PROPERTY
More information12/18/2017. Objective. Accessibility Code MN 1341 Frequent Questions and Key Criteria. Agenda. Code Documents
Objective Accessibility Code MN 1341 Frequent Questions and Key Criteria Highlight frequently asked Accessibility Code Questions Review the intent of the requirements Clarify the why behind the what of
More information3. Miscellaneous Instructions and Definitions.
Last page revision- March 31st, 1999 TEXAS ACCESSIBILITY STANDARDS (TAS) TAS Table of Contents 3. Miscellaneous Instructions and Definitions. 3.1 Graphic Conventions. Graphic conventions are shown in Table
More informationPhone: (707) Fax: (707) Web:
City of Sonoma Planning Department. 1 The Plaza Sonoma, CA 95476 Accessory Requirements Revised 10/19/17 Phone: (707) 938-3681 Fax: (707) 938-8775 E-mail: cityhall@sonomacity.org Web: www.sonomacity.org
More informationSuite Permission. Suites complying with shall be permitted to be used to meet the corridor access requirements of
Categorical Waiver Available: 5. Suites Sections 18/19.2.5 of the 2000 LSC requires every habitable room to have an exit access door leading directly to an exit access corridor; allows for exit access
More informationCodes Checklist Document 3
Ohio University Interior Architecture Codes Check p1 of 7 atthew Ziff,.Arch, Associate Professor Codes Checklist Document 3 General Construction Code Requirements Construction type of Building (Table 601)
More informationPresentation By. Chris Poujol. Jeffery Rodriguez. James Rigley
Means of Egress Presentation By Chris Poujol Jeffery Rodriguez James Rigley Table of Contents I. Means of Egress Definition II. History III. NYC Building Code IV. General Requirements IX. Exit Signs X.
More information2014 OSSC CHAPTER 10 - MEANS OF EGRESS TABLE OF CONTENTS
2014 OSSC CHAPTER 10 - MEANS OF EGRESS TABLE OF CONTENTS Section 1001 ADMINISTRATIVE 1001.1 General 1001.2 Alterations to existing means of egress 1001.3 Maintenance 1001.4 Fire safety and evacuation plans
More informationTiny House on Wheels A Tiny House
TINY HOUSES November 2018 The term Tiny House means different things to different people. Some people use the term to refer to a Tiny House on Wheels while others refer to a smaller version of a detached
More information625 San Anselmo Ave. Planning Submittal A0.00
LIVE OAK DESIGN COMPANY 855 POLK STREET #0 SAN FRANCISCO, CA 9409 65 SAN ANSELMO AVE. LLC SHEET NUMBER INDEX OF DRAWINGS SHEET NAME 0/09/08 - Planning Submittal 0/5/08 - Planning Submittal Rev 0 A0.00
More information2015 IBC Allowable Heights and Areas
2015 IBC Allowable Heights and Based on the 2015 International Building Code (IBC ) Course Description This seminar addresses the key issues of the 2015 International Building Code (IBC ) Chapter 5 regarding
More informationSection 9.5. Design of Areas, Spaces and Doorways
f):.-"> ~Ontario 2012 Building Code Compendium 9.5.1.5. 9.4.4.5. Reserved 9.4.4.6. Walls Supporting Drained Earth (See Appendix A.) Except where constructed in accordance with Section 9.15., walls supporting
More information2012 IBC Means of Egress
12/11/2017 Introductions 2012 IBC Means of Egress Based on the 2012 International Building Code (IBC ) Instructor introduction Exits Cell phones & pagers Schedule & breaks Student introductions 2 Goal
More informationINFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS
INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS Prepared by: Community Development Standards Branch Town of Innisfil www.innisfil.ca June 2016 Contents 1. Introduction... 1 2. Ontario Building
More informationCHAPTER 10 ARTICLE II DIVISION 2: MINIMUM STANDARDS
CHAPTER 10 ARTICLE II DIVISION 2: MINIMUM STANDARDS Sec. 10-56. Fitness for dwelling, dwelling units. Every dwelling and dwelling unit intended for use as a human habitation, occupancy or use, or held
More informationDisclaimer for Review of Plans
Disclaimer for Review of Plans The San Francisco Planning Code requires that the plans of certain proposed projects be provided to members of the public prior to the Cityʹs approval action on the project.
More informationBackground: 5 th Edition (2014) Florida Building Code, Building
Issue DS 2017-019. The petitioner Robert C Shumake of Shumake Architecture is seeking a declaratory statement on whether FBC 1029.1 require an emergency escape and rescue opening from sleeping units located
More informationElement Z General Design Requirements Owner Standards and Other Requirements
Definitions of Building Areas PART 1 - GENERAL 1.01 OVERVIEW A. The A/E shall submit an estimate for the project s Gross Area and Assignable Area with the Schematic Design Phase submission and shall submit
More informationBuchanan Centre. 475 Rolling Ridge Drive, State College, PA 16801
Buchanan Centre 475 Rolling Ridge Drive, State College, PA 16801 Tommy Songer Gambone, Songer & Associates, LLC 341 Science Park Road,Suite 202, State College, PA 16803 t3songer@gsarealty.com (814) 237-5384
More information5/10/2018. Copyright 2018 American Wood Council COURSE DESCRI PTI ON. Design Tools to Simplify IBC Chapter 5 (BCD425)
CHOOSING CONSTRUCTION TYPE JUST GOT EASIER: Design Tools to Simplify IBC Chapter 5 (BCD425) Paul Coats, PE, CBO Southeast Regional Manager American Wood Council Ricky McLain, PE, SE Senior Technical Director
More informationSPRINGBANK SIX CORNERS, LLC
SITE ADDRESS: 305 NORTH SOUTHPORT 356 WEST WELLINGTON ZONING DISTRICT: B3-2 (CURRENT) B3-2 (CURRENT) PROPOSED ZONING DISTRICT: B2-3 B2-3 PROPOSED USE: RESIDENTIAL RETAIL / ASSEMBLY / RESIDENTIAL F.A.R.:
More informationONE SUITE 106-8,350 SF FOR ADDITION INFORMATION, PLEASE CONTACT: TOM RICH Associate
SUITE 106-8,350 SF LOADING DOCK MAIL ROOM 2018 All rights reserved. This information has been obtained from sources believed reliable, but has not been verified for accuracy or completeness. Any projections,
More informationA001 DEMOLITION SITE PLAN A001 1:300 ADDITION DICKINSON DRIVE INGLESIDE, ONTARIO CATHOLIC DISTRICT SCHOOL BOARD OF EASTERN ONTARIO
DEMOLITION SITE AS NOTED No J.V.D. A001 1:300 0 10.0 m 50 m J.J. 2016-04-25 A001 ACAD FILE/FICHIER: 1619-A001.DWG SITE 1:300 No J.V.D. J.J. A002 A002 1:300 0 10.0 m 50 m 2016-04-20 ACAD FILE/FICHIER: 1619-A002.DWG
More informationCHAPTER 4 LIGHT, VENTILATION & OCCUPANCY LIMITATIONS
CHAPTER 4 LIGHT, VENTILATION & OCCUPANCY LIMITATIONS Chapter 4 establishes the minimum criteria for light and ventilation and identifies occupancy limitations. * Indicates code is still under review for
More informationAppendix B-2 Architect s floor plan sketches & sample elevations, clubhouse
The Hills at Southampton PDD Application Submission Mixed Use Planned Development District (MUPDD) Appendix B-2 Architect s floor plan sketches & sample elevations, clubhouse the hills at southampton Club
More informationResidential Accessible, Type A, and Type B Dwelling Unit Requirements 2012 International Building Code and 2009 ICC/ANSI A117.1
Residential Accessible, Type A, and Type B Dwelling Unit Requirements 2012 International Building Code and 2009 ICC/ANSI A117.1 20 E Olive Street STE 208 PO Box 1230 Bozeman, MT 59771-1230 Phone: (406)
More informationGENERAL ZONING CODE DESIGN CRITERIA FOR MULTIPLE- DWELLING DEVELOPMENT
INFORMATION BULLETIN / PUBLIC - ZONING CODE REFERENCE NO.: L.A. Zoning Code Effective: 12-30-03 DOCUMENT NO. P/ZC 2002-010 Revised: Previously Issued As: None GENERAL ZONING CODE DESIGN CRITERIA FOR MULTIPLE-
More informationCALL US
FOR SALE Ref: SD 2017 Hotel For Sale - 499,000 Whitecourt Hotel, 2 North Parade, Llandudno The White Court Hotel is ideally situated for exploring the treasure of North Wales, within walking distance to
More informationWHEA Lunch & Learn Series JAN Lauzon Life Safety Consulting. Suites
WHEA Lunch & Learn Series JAN-2017 Lauzon Life Safety Consulting Suites WHEA Lunch & Learn Series JAN-2017 Presenter Member: WHEA Code Committee WHEA Education Committee Lauzon Life Safety Consulting,
More informationA GF FANJUL & ASSOCIATES, LLC architecture, planning & interior design AA26000725 E:\16-PROJECTS\15-1008-FD-South Miami\15-1008-FD-MS-FINAL-SITE.dwg, 5/24/2017 7:37:20 AM, AutoCAD PDF (General Documentation).pc3
More informationHUDSON COUNTY NEW CONSTRUCTION MULTI-FAMILY RESIDENTIAL: NEWARK AVE JERSEY CITY, NJ BLOCK:11010, LOT:4. Design:
BLOCK:00, LOT:4 ZONING TABULATION CHART ITEM REQUIRED EXISTING PROPOSED NOTE VARIANCE MIN. LOT SIZE*,500 SF,93.35 SF,93.35 SF CONFORMING NO MAX. STRUCTURE HEIGHT 5 STORIES 3 5 CONFORMING NO MIN. LOT WIDTH
More informationCommercial Building for Lease. For Lease at $10.00/SF Gross + Expenses
Commercial Building for Lease EXECUTIVE SUMMARY 232-242 Boston Post Road Milford, Connecticut 06460 For Lease at $10.00/SF Gross + Expenses 5,750 SF freestanding building with direct access from Plains
More informationVestibule Requirement Intent
[2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004] Vestibule Requirement Intent Page 1 of 14 The primary intent behind the requirement for a vestibule is to reduce infiltration into a space
More informationExisting Building Accessibility Quick Checklist (CBC 11B) Job Address Permit
Existing Building Accessibility Quick Checklist (CBC 11B) Job Address Permit DIVISON 5: GENERAL SITE AND BUILDING ELEMENTS ENTRY (Items 1.1 & 1.6) Y N Parking Spaces Path from street accessible throughout
More informationAccess Statement for The Breakers 27 Lusty Glaze Road, Newquay, TR7 3AE, CORNWALL
This access statement does not contain personal opinions as to our suitability for those with access needs, but aims to accurately describe the facilities and services that we offer all our guests/visitors.
More informationAccess Statement for New England - Tregrill Farm Cottages
Access Statement for New England - Tregrill Farm Cottages Introduction Tregrill Farm Cottages is a small group of individually styled self catering properties. It is easy to find, close to village of Menheniot
More informationDRS RWANDA STANDARD. Code of practice for fire safety. of building. Part 5: Exit requirements and personal hazard.
RWANDA STANDARD DRS 186-5 Seconde dition Code of practice for fire safety of building Part 5: Exit requirements and personal hazard Reference number DRS 186-5: 2018 RBS yyyy CD RS 186-5:2013 ii Error!
More informationFOR LEASE AK BUSINESS CENTER KENSINGTON COURT, BRIGHTON, MICHIGAN
FOR LEASE AK BUSINESS CENTER 7651-7735 KENSINGTON COURT, BRIGHTON, MICHIGAN PROPERTY FEATURES Located in Kensington Pines Industrial Park South of I-96 (Exit 151) via Kensington Road 28 SF Office 2,52
More informationADA/TAS Plan Review & Inspection Worksheet Texas Access
ADA/TAS Plan Review & Inspection Worksheet Texas Access www.texasaccess.com Client: Project No: Address: City/Town: State/ZIP: Project Type: PLAN REVIEW INSPECTION BY DATE Applicable to project scope Results:
More informationFOR LEASE SUMMERWOOD CENTER & E. GRAND RIVER, BRIGHTON, MICHIGAN
FOR LEASE SUMMERWOOD CENTER 10291 & 10299 E. GRAND RIVER, BRIGHTON, MICHIGAN PROPERTY FEATURES *Suite I: *Suite L: *Contiguous: 2,259 SF 2,068 SF 4,327 SF Can Lease All or by Separate Suites Easy I-96/US-23
More informationRT-11 and RT-11N Districts Schedules
Districts Schedules 1 Intent The intent of this schedule is to allow a variety of housing options by encouraging development of multiple small houses and duplexes on larger lots and assembled sites, while
More informationWashington State Energy Code TABLE C (2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
Washington State Energy Code TABLE C405.4.2(2) COMMON SPACE-BY-SPACE TYPES a LPD (w/ft 2 ) Atrium - First 40 feet in height Atrium - Above 40 feet in height Audience/seating area - Permanent 0.03 per ft.
More informationExecutive Park Executive Park Dr Cincinnati, OH 45241
FOR LEASE Executive Park 4000-4100 Executive Park Dr Cincinnati, OH 45241 Senior Property Highlights Total SF: 191,852 Available RSF: 72,203 Asking $12.75/SF Exterior signage available Plentiful free parking
More informationA Guide to Secondary Suites
A Guide to Secondary Suites Introduction Building on the Saanich Official Community Plan (OCP) that supported secondary suites as a form of affordable housing, studies were undertaken in 2009 and in 2014.
More informationFacilities. A Brief Overview: How to Secure a Facility for Your. Charter School
Charter School Facilities A Brief Overview: How to Secure a Facility for Your Charter School Contents 1. Forming a Facilities Team 2. Creating a Timeline 3. Identifying Your Need 4. Searching for the Ideal
More informationARTICLE IV: DEVELOPMENT STANDARDS
ARTICLE IV: DEVELOPMENT STANDARDS IV-53 409 PRIVATE STREETS A private street means any way that provides ingress to, or egress from, property by means of vehicles or other means, or that provides travel
More information11A Accessibility Standards Frequently Asked Questions for Residential Projects
11A Accessibility Standards Frequently Asked Questions for Residential Projects Faruk Sezer, PE, CASp-659 Revised 02.05.2019 1 Preface This document is intended to provide information and technical guidance
More informationIndustrial For Sale. 62 Parsippany Blvd Boonton The building is physically located in Parsippany
Industrial For Sale Total Building Size: 21,500 SF Office Space: 2,500 SF Ceiling Height: 12 ft. The building is physically located in Parsippany Features: The entire building is air conditioned (new units)
More informationVirginia Beach, Virginia. oceanfront resort dist r ic t FORM-BASED CODE APPENDIX 1 TO CITY ZONING ORDINANCE
oceanfront resort dist r ic t FORM-BASE COE APPENIX 1 TO CITY ZONING ORINANCE JULY 10, 2012 Sec. 2.3 Building Type Properties Sec. 2.3 Building Type Properties 2.3.1 Intent The building types establish
More informationFOR LEASE RETAIL SPACE Creative Space in a prime location in Sunset Park! by Industry City
FOR LEASE RETAIL SPACE Creative Space in a prime location in Sunset Park! by Industry City Tri State Commercial Realty Inc 482 Coney Island Ave Brooklyn, NY 11218 tristatecr.com Executive Summary OFFERING
More informationSPAR SUBMITTAL COMMENT RESPONSES - NOVEMBER 3, 2016
File Name & Location: Z:\230 - SNM - Essex San Mateo Study\Drawings\AutoCad\09 Sheet Files\A000.dwg Layout: A000 - COVER Printed: Wed, 02 Nov 206-8:09 COMMENT RESPONSES - NOVEMER 3, 206 CIVIL ENGINEER:
More informationSAFEWAY - OAKLAND, CALIFORNIA PLANNING REVISIONS 1 - JULY 26, 2010
60 COLLEGE AVENUE OAKLAND, CA 9468 STORE #80 CURRENT OWNER: STORE NUMBER: 80 598 STONERIDGE MALL ROAD PLEASANTON, CA 94588-9 P) 95.46.08 F) 95.46.86 ASSESSOR'S PARCEL NUMBER: 048A00000 NO. DATE ISSUES
More informationBUILDING ADDITIONAL UNITS ON YOUR PROPERTY
BUILDING ADDITIONAL UNITS ON YOUR PROPERTY SF Planning Department Department of Building Inspection EARTHQUAKE FAIR ADU/ LEGALIZATION WORKSHOP June 15, 2017 What is an accessory dwelling unit (ADU)? A
More informationc 211 Hotel Fire Safety Act
Ontario: Revised Statutes 1970 c 211 Hotel Fire Safety Act Ontario Queen's Printer for Ontario, 1970 Follow this and additional works at: http://digitalcommons.osgoode.yorku.ca/rso Bibliographic Citation
More informationMINIMUM PARKING STANDARDS DRIVEWAY WIDTH AND SLOPE TABLES LESS THAN 13 STALLS
MINIMUM PARKING STANDARDS DRIVEWAY AND TABLES LESS THAN STALLS SINGLE FAMILY RES. - - - - In 8* In 8 In 6 In 6 In 6 TO 99 STALLS - - - - 8-6 - In 8* In 8 In 6 In 6 STALLS OR MORE * Required for the first
More informationADAPTABLE DESIGN GUIDELINES
ADAPTABLE DESIGN GUIDELINES Adaptable design creates liveable residences for a wider range of persons than current building codes require. By considering design features that can be easily and inexpensively
More informationLast Action: APPLICATION PROCESSED - ENTIRE 04/01/2009 (D)
1 of 5 4/1/2009 4:11 PM NYC Department of Buildings Application Details Premises: 703 WASHINGTON STREET MANHATTAN Job No: 110427440 BIN: 1011870 Block: 633 Lot: 37 Document: 01 OF 1 Job Type: NB - NEW
More informationORDINANCE NO
AN ORDINANCE OF THE CITY OF SANTA CRUZ AMENDING TITLE 24, SECTION 24.12.200 OF THE MUNICIPAL CODE, THE ZONING ORDINANCE, TO EXEMPT MIXED USE DEVELOPMENT FROM COVERED PARKING REQUIREMENTS. The City Council
More informationFOR LEASE. HAGGERTY BUILDING 5918 Meridian Blvd. Brighton, Michigan (810) FOR DETAILS CONTACT PROPERTY FEATURES
FOR LEASE HAGGERTY BUILDING 5918 Meridian Blvd. Brighton, Michigan FOR DETAILS CONTACT J D john.dinsmore@lee-associates.com (810) 923-9106 www. -.com PROPERTY FEATURES Suite 2-1,350 SF Available Great
More informationBuilding Code Extracts from the National Building Code of Canada 2010
3.2.6. dditional Requirements for High Buildings (See ppendix B.) 3.2.6.1. pplication This Subsection applies to a building a) of Group, D, E or F major occupancy classification that is more than i) 36
More informationHOUSING CODE CHECKLIST FOR RENTAL INSPECTIONS
HOUSING CODE CHECKLIST FOR RENTAL INSPECTIONS GENERAL 410.200 Heating facilities must be fully operational and well maintained with facilities capable of heating every room (including bathroom and kitchen).
More informationExtracts from the National Building Code of Canada
3) The number of lamps connected to a single unit equipment shall not result in a load in excess of the watts output rating marked on the equipment for the emergency period required by the National Building
More informationLODGING HOUSE REGULATIONS - CITY OF FITCHBURG
LODGING HOUSE REGULATIONS - CITY OF FITCHBURG 1. Authority and Scope: The Board of Health for the City of Fitchburg enacts the following regulations which apply to all lodging houses required to be licensed
More informationIndustrial Property for Sale or Lease with Quick Access to Major Thoroughfares. For Sale at $2,800, or Lease at $5.00/SF NNN
EXECUTIVE SUMMARY Industrial Property for Sale or Lease with Quick Access to Major Thoroughfares Milford, Connecticut 06460 For Sale at $2,800,000.00 or Lease at $5.00/SF NNN u u u Approximately 50,254
More informationSPECIFIC GUIDANCE FOR A BEDSIT TYPE HOUSE IN MULTIPLE OCCUPATION (HMO)
Document A SPECIFIC GUIDANCE FOR A BEDSIT TYPE HOUSE IN MULTIPLE OCCUPATION (HMO) This document is intended as a specific guide for persons who own, manage or control Bedsit type - houses in multiple occupations
More informationDRAFT DESIGN REPORT. Kevin Trinastic. WHITEWATER, WI Project Number: 11 L 2 J
DRAFT DESIGN REPORT DIVISION OF FACILITIES DEVELOPMENT 0 East Wilson Street, 7th Floor Post Office Box 7866 Madison, WI 53707 MARCH, 203 WEST CAMPUS RESIDENCE RENOVATIONS PHASE UNIVERSITY OF WISCON SIN
More information1003 Pacific Street By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)
Zoning and Development By-law Planning and Development Services, 453 W. 12th Ave Vancouver, BC V5Y 1V4 F 604.873.7344 fax 604.873.7060 planning@vancouver.ca CD-1 (169) 1003 Pacific Street By-law No. 5852
More informationALABAMA AVENUE PORTFOLIO
19-27 Alabama Avenue Brooklyn, NY 11207 Qualified Opportunity Zone 1 N O N - E N D O R S E M E N T A N D D I S C L A I M E R N O T I C E Non-Endorsements Marcus & Millichap is not affiliated with, sponsored
More informationVACANT WEST VILLAGE TOWNHOUSE FOR SALE 146 WAVERLY PLACE
Alvin H. Glick Randy E. Glick Jason R. Glick John H. Mautner (1919-1990) Real Estate Management Sales - Mortgages Glen Fogel David C. Parks Esq. Kenneth Kandel VACANT WEST VILLAGE TOWNHOUSE FOR SALE 146
More information33 The Spinney, Cramlington
Price 249,950 *** FOUR BEDROOM DETACHED HOUSE *** EN-SUITE BATHROOM *** CONSERVATORY *** DOWNSTAIRS WC *** LOVELY REAR GARDEN *** GARAGE & PARKING FOR FOUR CARS *** CUL-D-SAC LOCATION *** FREEHOLD ***
More informationThis access statement does not contain personal opinions as to our suitability for
This access statement does not contain personal opinions as to our suitability for those with access needs, but aims to accurately describe the facilities and services that we offer all our guests/visitors.
More informationNational Trust Cottages Access Statement
National Trust Cottages Access Statement Longstone 001006 Isle of Wight Introduction Edwardian detached cottage at head of Longstone in beautiful surrounding countryside This cottage is isolated and a
More informationCampus Tornado Shelters. Weather Department Environmental Health & Safety Northern Illinois University
Campus Tornado Shelters Weather Department Environmental Health & Safety Northern Illinois University A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A Academic Advising Center: South/southwest end
More informationMuhlenberg College- Campus Accessibility
Muhlenberg College- Campus Accessibility Muhlenberg College continues to strive toward accessibility for all of its buildings. Academic Buildings: Anthropology/Sociology- Shared building- see Hillel for
More informationAccess Statement for Mabyn 19 The Village, Watergate Bay, TR8 4AA, CORNWALL
This access statement does not contain personal opinions as to our suitability for those with access needs, but aims to accurately describe the facilities and services that we offer all our guests/visitors.
More informationOld Town La Quinta Main St, La Quinta, CA Grant Higuchi Old Town La Quinta Main St,La Quinta, CA
Old Town La Quinta 78075 Main St, La Quinta, CA 92253 Grant Higuchi Old Town La Quinta 78100 Main St,La Quinta, CA 92253 grant@oldtownlaquinta.com Old Town La Quinta Rent Spectacular Setting with Great
More informationShasta Street, Redwood City SLIDESHOW
FOR LEASE ±16,717 SF OR R&D BLOCKS FROM DOWNTOWN PHOTO SLIDESHOW HIGHLIGHTS Date Available: Q3 2018 Available Space: ±16,717 SF Suite 725: ±9,086 SF Suite 735: ±7,587 SF Extensive Exterior/Interior Remodel
More informationEmergency Evacuation and Stairwell Signage
Orange County Fire Authority Community Risk Reduction 1 Fire Authority Road, Building A, Irvine, CA. 92602 www.ocfa.org 714-573-6100 Emergency Evacuation and Stairwell Signage Guideline E-02 Serving the
More informationWestwood Manor Homes FOR SALE & 2209 S 33rd St., 2210 S 34th St. Fort Pierce FL $499,000/each
FOR SALE $499,000/each Property Details PRICE BUILDING SIZE NO. OF ROOMS BUILDING TYPE $499,000/each 4,324 SF (all) 8 bed / 8 bath Residential Excellent large family homes available for purchase (all vacant)
More information(2) Determining Occupant Loads for the Operation of a Building (The Alberta Fire Code)
(d) (e) (f) (g) (h) if emergency lighting is required if exit signs are required if additional requirements apply for high buildings the type of hardware required on exit and access to exit doors the required
More informationThe application of the California Building Code
PART 2 Building Planning Chapters 3 through 6 Chapter 3 Use and Occupancy Classification Chapter 4 Special Detailed Requirements Based on Use and Occupancy Chapter 5 General Building Heights and Areas
More informationCOUNTY OF NEVADA PLANNING DEPARTMENT Eric Rood Administration Bldg. 950 Maidu Avenue Nevada City, California
COUNTY OF NEVADA PLANNING DEPARTMENT Eric Rood Administration Bldg. 950 Maidu Avenue Nevada City, California 95959-8617 SECOND DWELLING UNIT GUIDELINES Nevada County Zoning Regulations allow for the development
More informationArlington County. Smart Choice Homes. Arlington County. Homes for all of us. Homes for a lifetime. Home
Arlington County Smart Choice Homes Home Arlington County Homes for all of us. Homes for a lifetime Why Smart Choice Homes? Smart design equals smart living. This booklet provides the building blocks to
More informationAccess Statement for Agnes 16 The Village, Watergate Bay, TR8 4AA, CORNWALL
This access statement does not contain personal opinions as to our suitability for those with access needs, but aims to accurately describe the facilities and services that we offer all our guests/visitors.
More informationMILLENIA STUDIO FOR RENT
MILLENIA STUDIO FOR RENT FOR RENT: FULLY FURNISHED CONDO IN ORTIGAS CENTER Millenia Suite 2112 is a cozy 24.1 sq.m. studio unit at Millenia Tower which is located at Escriva Drive, near University of Asia
More informationTIME SQUARE TENANT. SPENCER WIXOM o: (801) c: (801) South 300 West Salt Lake City
TIME SQUARE 2300 South 300 West Salt Lake City TENANT Time Square is strategically located at the heart of Salt Lake City. At the intersection of I 15 and I 80, Time Square provides unmatched accessibility
More informationDEVELOPMENT REGULATIONS FOR THE R-1 ZONE (Single Family Residence) Density ( ) 7,260 sq. ft. of net lot area For the creation of new lots
Planning Division 425 S. Mission Drive, San Gabriel, CA 91776 City of San Gabriel Website: www.sangabrielcity.com FOUNDED 1771 Tel: (626) 308-2806 Fax: (626) 458-2830 DEVELOPMENT REGULATIONS FOR THE R-1
More information